932 resultados para GPS monitor aerospace
Resumo:
Exercise-based cardiac rehabilitation (CR) is efficacious in reducing mortality and hospital admissions; however it remains inaccessible to large proportions of the patient population. Removal of attendance barriers for hospital or centre-based CR has seen the promotion of home-based CR. Delivery of safe and appropriately prescribed exercise in the home was first documented 25 years ago, with the utilisation of fixed land-line telecommunications to monitor ECG. The advent of miniature ECG sensors, in conjunction with smartphones, now enables CR to be delivered with greater flexibility with regard to location, time and format, while retaining the capacity for real-time patient monitoring. A range of new systems allow other signals including speed, location, pulse oximetry, and respiration to be monitored and these may have application in CR. There is compelling evidence that telemonitored-based CR is an effective alternative to traditional CR practice. The long-standing barrier of access to centre-based CR, combined with new delivery platforms, raises the question of when telemonitored-based CR could replace conventional approaches as the standard practice.
Resumo:
In this paper, we present a monocular vision based autonomous navigation system for Micro Aerial Vehicles (MAVs) in GPS-denied environments. The major drawback of monocular systems is that the depth scale of the scene can not be determined without prior knowledge or other sensors. To address this problem, we minimize a cost function consisting of a drift-free altitude measurement and up-to-scale position estimate obtained using the visual sensor. We evaluate the scale estimator, state estimator and controller performance by comparing with ground truth data acquired using a motion capture system. All resources including source code, tutorial documentation and system models are available online.
Resumo:
This thesis establishes performance properties for approximate filters and controllers that are designed on the basis of approximate dynamic system representations. These performance properties provide a theoretical justification for the widespread application of approximate filters and controllers in the common situation where system models are not known with complete certainty. This research also provides useful tools for approximate filter designs, which are applied to hybrid filtering of uncertain nonlinear systems. As a contribution towards applications, this thesis also investigates air traffic separation control in the presence of measurement uncertainties.
Resumo:
With the projected increase in older adults, the older driver population is estimated to be the fastest growing cohort of drivers among many developed countries. The increased physical fragility associated with the aging process make older adults who drive private automobiles a vulnerable road user group. Much of the current research on older drivers’ behaviours and practices rely on self-report data. This paper explores the utility of in-vehicle devices (Global Positioning Systems and recording accelerometers) in assessing older drivers’ habitual driving behaviours. Seventy-eight older drivers (above 65 years of age), from the Australian Capital Territory, Australia, participated in the current study. The driving behaviours and practices of these participants were prospectively assessed over a two-week period. The use of combined GPS and recording accelerometers to improve understanding of older drivers’ driving behaviours show promise within the current study. The challenges of using multiple in-vehicle devices in assessing driving beahaviours and performances within this cohort will be discussed. Based on the current findings, recommendations for future research regarding the use of in-vehicle devices among the older driver cohort are proposed.
Resumo:
Private-sector organizations play a critical role in shaping the food environments of individuals and populations. However, there is currently very limited independent monitoring of private-sector actions related to food environments. This paper reviews previous efforts to monitor the private sector in this area, and outlines a proposed approach to monitor private-sector policies and practices related to food environments, and their influence on obesity and non-communicable disease (NCD) prevention. A step-wise approach to data collection is recommended, in which the first (‘minimal’) step is the collation of publicly available food and nutrition-related policies of selected private-sector organizations. The second (‘expanded’) step assesses the nutritional composition of each organization's products, their promotions to children, their labelling practices, and the accessibility, availability and affordability of their products. The third (‘optimal’) step includes data on other commercial activities that may influence food environments, such as political lobbying and corporate philanthropy. The proposed approach will be further developed and piloted in countries of varying size and income levels. There is potential for this approach to enable national and international benchmarking of private-sector policies and practices, and to inform efforts to hold the private sector to account for their role in obesity and NCD prevention.
Resumo:
The E&P sector can learn much about asset maintenance from the space and satellite industry. Practitioners from both the upstream oil and gas industry and the space and satellite sector have repeatedly noted several striking similarities between the two industries over the years, which have in turn resulted in many direct comparisons in the media and industry press. The similarities between the two industries have even resulted in a modest amount of cross-pollinating between the respective supply chains. Because the operating conditions of both industries are so extreme, some oil and gas equipment vendors have occasionally sourced motors and other parts from aerospace contractors. Also, satellites are now being used to assess oil fires, detect subsidence in oil fields, measure oil spills, collect and transmit operational data from oil and gas fields, and monitor the movement of icebergs that might potentially collide with offshore oil and gas installations.
Resumo:
BACKGROUND Inconsistencies in research findings on the impact of the built environment on walking across the life course may be methodologically driven. Commonly used methods to define 'neighbourhood', from which built environment variables are measured, may not accurately represent the spatial extent to which the behaviour in question occurs. This paper aims to provide new methods for spatially defining 'neighbourhood' based on how people use their surrounding environment. RESULTS Informed by Global Positioning Systems (GPS) tracking data, several alternative neighbourhood delineation techniques were examined (i.e., variable width, convex hull and standard deviation buffers). Compared with traditionally used buffers (i.e., circular and polygon network), differences were found in built environment characteristics within the newly created 'neighbourhoods'. Model fit statistics indicated that exposure measures derived from alternative buffering techniques provided a better fit when examining the relationship between land-use and walking for transport or leisure. CONCLUSIONS This research identifies how changes in the spatial extent from which built environment measures are derived may influence walking behaviour. Buffer size and orientation influences the relationship between built environment measures and walking for leisure in older adults. The use of GPS data proved suitable for re-examining operational definitions of neighbourhood.
Resumo:
This paper presents an approach to autonomously monitor the behavior of a robot endowed with several navigation and locomotion modes, adapted to the terrain to traverse. The mode selection process is done in two steps: the best suited mode is firstly selected on the basis of initial information or a qualitative map built on-line by the robot. Then, the motions of the robot are monitored by various processes that update mode transition probabilities in a Markov system. The paper focuses on this latter selection process: the overall approach is depicted, and preliminary experimental results are presented
Resumo:
Reliability of carrier phase ambiguity resolution (AR) of an integer least-squares (ILS) problem depends on ambiguity success rate (ASR), which in practice can be well approximated by the success probability of integer bootstrapping solutions. With the current GPS constellation, sufficiently high ASR of geometry-based model can only be achievable at certain percentage of time. As a result, high reliability of AR cannot be assured by the single constellation. In the event of dual constellations system (DCS), for example, GPS and Beidou, which provide more satellites in view, users can expect significant performance benefits such as AR reliability and high precision positioning solutions. Simply using all the satellites in view for AR and positioning is a straightforward solution, but does not necessarily lead to high reliability as it is hoped. The paper presents an alternative approach that selects a subset of the visible satellites to achieve a higher reliability performance of the AR solutions in a multi-GNSS environment, instead of using all the satellites. Traditionally, satellite selection algorithms are mostly based on the position dilution of precision (PDOP) in order to meet accuracy requirements. In this contribution, some reliability criteria are introduced for GNSS satellite selection, and a novel satellite selection algorithm for reliable ambiguity resolution (SARA) is developed. The SARA algorithm allows receivers to select a subset of satellites for achieving high ASR such as above 0.99. Numerical results from a simulated dual constellation cases show that with the SARA procedure, the percentages of ASR values in excess of 0.99 and the percentages of ratio-test values passing the threshold 3 are both higher than those directly using all satellites in view, particularly in the case of dual-constellation, the percentages of ASRs (>0.99) and ratio-test values (>3) could be as high as 98.0 and 98.5 % respectively, compared to 18.1 and 25.0 % without satellite selection process. It is also worth noting that the implementation of SARA is simple and the computation time is low, which can be applied in most real-time data processing applications.
Resumo:
Purpose The purpose of this study was to evaluate the validity of the CSA activity monitor as a measure of children's physical activity using energy expenditure (EE) as a criterion measure. Methods Thirty subjects aged 10 to 14 performed three 5-min treadmill bouts at 3, 4, and 6 mph, respectively. While on the treadmill, subjects wore CSA (WAM 7164) activity monitors on the right and left hips. (V) over dot O-2 was monitored continuously by an automated system. EE was determined by multiplying the average (V) over dot O-2 by the caloric equivalent of the mean respiratory exchange ratio. Results Repeated measures ANOVA indicated that both CSA monitors were sensitive to changes in treadmill speed. Mean activity counts from each CSA unit were not significantly different and the intraclass reliability coefficient for the two CSA units across all speeds was 0.87. Activity counts from both CSA units were strongly correlated with EE (r = 0.86 and 0.87, P < 0.001). An EE prediction equation was developed from 20 randomly selected subjects and cross-validated on the remaining 10. The equation predicted mean EE within 0.01 kcal.min(-1). The correlation between actual and predicted values was 0.93 (P < 0.01) and the SEE was 0.93 kcal.min(-1). Conclusion These data indicate that the CSA monitor is a valid and reliable tool for quantifying treadmill walking and running in children.
Resumo:
This paper presents a practical recursive fault detection and diagnosis (FDD) scheme for online identification of actuator faults for unmanned aerial systems (UASs) based on the unscented Kalman filtering (UKF) method. The proposed FDD algorithm aims to monitor health status of actuators and provide indication of actuator faults with reliability, offering necessary information for the design of fault-tolerant flight control systems to compensate for side-effects and improve fail-safe capability when actuator faults occur. The fault detection is conducted by designing separate UKFs to detect aileron and elevator faults using a nonlinear six degree-of-freedom (DOF) UAS model. The fault diagnosis is achieved by isolating true faults by using the Bayesian Classifier (BC) method together with a decision criterion to avoid false alarms. High-fidelity simulations with and without measurement noise are conducted with practical constraints considered for typical actuator fault scenarios, and the proposed FDD exhibits consistent effectiveness in identifying occurrence of actuator faults, verifying its suitability for integration into the design of fault-tolerant flight control systems for emergency landing of UASs.
Resumo:
The unique physical and movement characteristics of children necessitate the development of accelerometer equations and cut points that are population specific. The purpose of this study is to develop an ecologically valid cut point for the Biotrainer Pro monitor that reflects a threshold for moderate-intensity physical activity in elementary school children. A sample of 30 children (ages 8-12) wore a Biotrainer monitor while completing a series of 7 movement tasks (calibration phase) and while participating in an organized group activity (cross-validation phase). Videotapes from each session were processed using a computerized direct-observation technique to provide a criterion measure of physical activity. Analyses involved the use of mixed-model regression and receiver operator characteristic (ROC) curves. The results indicated that a cut point of 4 counts/min provides the optimal balance between the related needs for sensitivity (accurately detecting activity) and specificity (limiting misclassification of activity as inactivity). Results with the cross-validation data demonstrated that this value yielded the best overall kappa (.58) and a high classification agreement (84%) for activity determination. The specificity of 93% demonstrates that the proposed cut point can accurately detect activity; however, the lower sensitivity value of 61% suggests that some minutes of activity might be incorrectly classified as inactivity. The cut point of 4 counts/min provides an ecologically valid cut point to capture physical activity in children using the Biotrainer Pro activity monitor.
Resumo:
Multi-touch interfaces across a wide range of hardware platforms are becoming pervasive. This is due to the adoption of smart phones and tablets in both the consumer and corporate market place. This paper proposes a human-machine interface to interact with unmanned aerial systems based on the philosophy of multi-touch hardware-independent high-level interaction with multiple systems simultaneously. Our approach incorporates emerging development methods for multi-touch interfaces on mobile platforms. A framework is defined for supporting multiple protocols. An open source solution is presented that demonstrates: architecture supporting different communications hardware; an extensible approach for supporting multiple protocols; and the ability to monitor and interact with multiple UAVs from multiple clients simultaneously. Validation tests were conducted to assess the performance, scalability and impact on packet latency under different client configurations.