922 resultados para Facial prosthesis
Resumo:
Background The benefits and safety transcutaneous bone anchored prosthesis relying on a screw fixation are well reported.[1-17] However, most of the studies on press-fit implants and joint replacement technology have focused on surgical techniques.[3, 18-23] One European centre using this technique has reported on health related quality of life (HRQOL) for a group of individuals with transfemoral amputation (TFA).[3] Data from other centres are needed to assess the effectiveness of the technique in different settings. Aim This study aimed at reporting HRQOL data at baseline and up to 2-year follow-up for a group of TFAs treated by Osseointegration Group of Australia who followed the Osseointegration Group of Australia Accelerated Protocol (OGAAP), in Sydney between 08/12/2011 and 09/04/2014. Method A total of 16 TFAs (7 females and 9 males, age 51 ± 12 y, height 1.73 ± 0.12 m, weight 83 ±18 kg) participated in this study. The cause of amputation was trauma or congenital limb deficiency for 11 (69%) and 5 (31%) participants, respectively. A total of 12 (75%) participants were prosthetic users while 4(25%) were wheelchair bound prior the surgery. The HRQOL were obtained from Questionnaire for Persons with Transfemoral Amputation (Q-TFA) using the four main scales (i.e., Prosthetic use, Mobility, Problem, Global) one year before and between 6.5 and 24 months after the Stage 1 of the surgeries for the baseline and follow-up, respectively. Results The lapse of time before and after Stage 1 was -6.19±3.54 and 10.83±3.58 months respectively. The raw score and percentage of improvement are presented in Figures 1 and 2, respectively. Discussion & Conclusion The average results demonstrated an improvement in each domain, particularly in the reduction of problems and an increase in global state. Furthermore, 56%, 75%, 94% and 69% of the participants reported an improvement in Prosthetic use, Mobility, Problem, Global scales, respectively. These results were comparable to previous studies relying of screwed fixation confirming that press-fit implantation is a viable alternative for bone-anchored prostheses.[1, 7, 8]
Resumo:
Background Over the last two decades, Transcutaneous Bone-Anchored Prosthesis (TCBAP) has proven to be an effective alternative for prosthetic attachment for amputees, particularly for individuals unable to wear a socket. [1-17] However, the load transmitted through a typical TCBAP to the residual tibia and knee joint can be unbearable for transtibial amputees with knee arthritis. Aim A. To describe the surgical procedure combining TKR with TCBAP for the first time; and B. To present preliminary data on potential risks and benefits with assessment of clinical and functional outcomes at follow up Method We used a TCBAP connected to the tibial base plate of a Total Knee Replacement (TKR) prosthesis enabling the tibial residuum and the knee joint to act as weight sharing structures by transferring the load directly to the femur. We performed a standard hinged TKR connected to a custom made TCBAP at the first stage followed by creating a skin implant interface as a second stage. We retrospectively reviewed four cases of trans-tibial amputations presenting with knee joint arthritis. Patients were assessed clinically and functionally including standard measures of health-related quality of life, amputee mobility predictor tool, ambulation tests and actual activity level. Progress was monitored for 6-24 months. Results Clinical outcomes including adverse events show no major complications but one case of superficial infection. Functional outcomes improved for all participants as early as 6 months follow up. Discussion & Conclusion TKR and TCBAP were combined for the first time in this proof-of-concept case series. The preliminary outcomes indicated that this procedure is potentially a safe and effective alternative for this patient group despite the theoretical increase in risk of ascending infection through the skin-implant interface to the external environment. We suggest larger comparative series to further validate these results.
Resumo:
Background Over the last two decades, Transcutaneous Bone-Anchored Prosthesis (TCBAP) has proven to be an effective alternative for prosthetic attachment for above knee amputees, particularly for individuals suffering from socket interface related complications. [1-17] Amputees with a very short femoral residuum (<15 cm) are at a considerable higher risk for these complications as well as high risk of implant failure, if they underwent a typical TCBAP due to the relatively small bony-implant contact leading to a need of a novel technique. Aim A. To describe the surgical procedure combining THR with TCBAP for the first time; and B. To present preliminary data on potential risks and benefits with assessment of clinical and functional outcomes at follow up Method We used a TCBAP connected to the stem of a Total Hip Replacement (THR) prosthesis enabling the femoral residuum and the hip joint to act as weight sharing structures by transferring the load directly to the pelvis. We performed a tri-polar THR connected to a custom made TCBAP at the first stage followed by creating a skin implant interface as a second stage. We retrospectively reviewed three cases of transfemoral amputations presenting with extremely short femoral residuum. Patients were assessed clinically and functionally including standard measures of health-related quality of life, amputee mobility predictor tool, ambulation tests and actual activity level. Progress was monitored for 6-24 months. Results Clinical outcomes including adverse events show no major complications. Functional outcomes improved for all participants as early as 6 months follow up. All cases were wheelchair bound preoperatively (K0 – AMPRO) improved to walking with One stick (K3 – AMPRO) at 3 months follow up. Discussion & Conclusion THR and TCBAP were combined for the first time in this proof-of-concept case series. The preliminary outcomes indicated that this procedure is potentially a safe and effective alternative despite the theoretical increase in risk of ascending infection through the skin-implant interface to the external environment for this patient group. We suggest larger comparative series to further validate these results.
Resumo:
Background Individuals with limb amputation fitted with conventional socket-suspended prostheses often experience socket related discomfort leading to a significant decrease in quality of life. Most of these concerns can be overcome by surgical techniques enabling bone-anchored prostheses. In this case, the prosthesis is attached directly to the residual skeleton through a percutaneous implant (e.g., screw type fixation, press-fit implant).[46, 48, 51, 52, 77, 78] The aim of this study is to present the current advances in these surgical techniques worldwide with a strong focus on the current challenges. Methods The current advances will be extracted from a systematic literature review including approximately 40 articles. The outcomes measured will include the estimation of the population worldwide as well as the complications (e.g., infection, loosening, fractures, and breakage) and the benefits (e.g., functional outcomes, health-related quality of life).[5-19, 51-53, 55, 57, 58, 62, 73, 79] Results The population of individuals fitted with a bone-anchored prosthesis is approximately 550 worldwide. Publications focusing on infection are sparse. However, the rate of superficial infection is estimated at 20%. Deep infection occurs rarely. Loosening and peri-prosthetic fractures are fairly uncommon. Breakage of implant parts occurs regularly mainly due to fall. All studies reported a significant improvement in functional level and overall quality of life. Conclusions Several commercial implants are in developments in Europe and US. The number of procedures is consistently growing worldwide. This technique might be primary way to fit a prosthesis to young and active amputees by 2025.
Resumo:
Background Individuals with limb amputation fitted with conventional socket-suspended prostheses often experience socket related discomfort leading to a significant decrease in quality of life. Most of these concerns can be overcome by surgical techniques enabling bone-anchored prostheses. In this case, the prosthesis is attached directly to the residual skeleton through a percutaneous implant (e.g., screw type fixation, press-fit implant).[46, 48, 51, 52, 77, 78] The aim of this study is to present the current advances in these surgical techniques worldwide with a strong focus on the current challenges. Methods The current advances will be extracted from a systematic literature review including approximately 40 articles. The outcomes measured will include the estimation of the population worldwide as well as the complications (e.g., infection, loosening, fractures, and breakage) and the benefits (e.g., functional outcomes, health-related quality of life).[5-19, 51-53, 55, 57, 58, 62, 73, 79] Results The population of individuals fitted with a bone-anchored prosthesis is approximately 550 worldwide. Publications focusing on infection are sparse. However, the rate of superficial infection is estimated at 20%. Deep infection occurs rarely. Loosening and peri-prosthetic fractures are fairly uncommon. Breakage of implant parts occurs regularly mainly due to fall. All studies reported a significant improvement in functional level and overall quality of life. Conclusions Several commercial implants are in developments in Europe and US. The number of procedures is consistently growing worldwide. This technique might be primary way to fit a prosthesis to young and active amputees by 2025.
Resumo:
By definition, the two faces of a pi bond are equivalent.1 However, they are rendered nonequivalent in most molecules because of the absence of a plane of symmetry encompassing the double bond and the adjacent substituents. As a result, additions to trigonal centers from the two faces need not be equally facile. Exploiting this stereodifferentiation in a controlled manner represents one of the core problems in organic synthesis. Evidently, the factors which determine such diastereoselection need to be delineated in as much detail as possible.
Resumo:
Developments of surgical attachments for bone-anchored prostheses are slowly but surely winning over the initial disbelief in the orthopedic community. Clearly, this option is becoming accessible to a wide range of individuals with limb loss. Seminal studies have demonstrated that the pioneering procedure relying on screw-type fixation engenders major clinical benefits and acceptable safety. The surgical procedure for press-fit implants, such as the Integral-Leg-Prosthesis (ILP) has been described Dr Aschoff and his team. Some clinical benefits of press-fit implants have been also established. Here, his team is once again taking a leading role by sharing the progression over 15 years of the rate of deep infections for 69 individuals with transfemoral amputation fitted with three successive refined versions of the ILP. By definition, a double-blind randomized clinical trial to test the effect of different fixation’s design is difficult. Alternatively, Juhnke and colleagues are reporting the outcomes of action-research study for a cohort of participants. The first and foremost important outcome of this study is the confirmation that the current design of the IPL and rehabilitation program are altogether leading to an acceptable rate of deep infection and other adverse events (e.g., structural failure of implant, periprosthetic factures). This study is also providing a strong insight onto the effect of major phases in redesign of an implant on the risk of infection. This is an important reminder that the development of a successful osseointegrated implant is unlikely to be immediate but the results of a learning curve made of empirical and sequential changes led by a reflective clinical practice. Clearly, this study provided better understanding of the safety of the ILP surgical and rehabilitation procedure while establishing standards and benchmark data for future studies focusing on design and infection of press-fit implants. Complementary observations of relationship between infection and cofounders such as loading of the prosthesis and prosthetic components used would be beneficial.Further definitive evidences of the clinical benefits with the latest design would be valuable, although an increase in health related quality of life and functional outcomes are likely to be confirmed. Altogether, the authors are providing compelling evidence that bone-anchored attachments particularly those relying on press-fit implants are an established alternative to socket prostheses.
Resumo:
Humans are a social species with the internal capability to process social information from other humans. To understand others behavior and to react accordingly, it is necessary to infer their internal states, emotions and aims, which are conveyed by subtle nonverbal bodily cues such as postures, gestures, and facial expressions. This thesis investigates the brain functions underlying the processing of such social information. Studies I and II of this thesis explore the neural basis of perceiving pain from another person s facial expressions by means of functional magnetic resonance imaging (fMRI) and magnetoencephalography (MEG). In Study I, observing another s facial expression of pain activated the affective pain system (previously associated with self-experienced pain) in accordance with the intensity of the observed expression. The strength of the response in anterior insula was also linked to the observer s empathic abilities. The cortical processing of facial pain expressions advanced from the visual to temporal-lobe areas at similar latencies (around 300 500 ms) to those previously shown for emotional expressions such as fear or disgust. Study III shows that perceiving a yawning face is associated with middle and posterior STS activity, and the contagiousness of a yawn correlates negatively with amygdalar activity. Study IV explored the brain correlates of interpreting social interaction between two members of the same species, in this case human and canine. Observing interaction engaged brain activity in very similar manner for both species. Moreover, the body and object sensitive brain areas of dog experts differentiated interaction from noninteraction in both humans and dogs whereas in the control subjects, similar differentiation occurred only for humans. Finally, Study V shows the engagement of the brain area associated with biological motion when exposed to the sounds produced by a single human being walking. However, more complex pattern of activation, with the walking sounds of several persons, suggests that as the social situation becomes more complex so does the brain response. Taken together, these studies demonstrate the roles of distinct cortical and subcortical brain regions in the perception and sharing of others internal states via facial and bodily gestures, and the connection of brain responses to behavioral attributes.
Resumo:
Background and purpose — Osseointegrated implants are an alternative for prosthetic attachment in individuals with amputation who are unable to wear a socket. However, the load transmitted through the osseointegrated fixation to the residual tibia and knee joint can be unbearable for those with transtibial amputation and knee arthritis. We report on the feasibility of combining total knee replacement (TKR) with an osseointegrated implant for prosthetic attachment. Patients and methods — We retrospectively reviewed all 4 cases (aged 38–77 years) of transtibial amputations managed with osseointegration and TKR in 2012–2014. The below-the-knee prosthesis was connected to the tibial base plate of a TKR, enabling the tibial residuum and knee joint to act as weight-sharing structures. A 2-stage procedure involved connecting a standard hinged TKR to custom-made implants and creation of a skin-implant interface. Clinical outcomes were assessed at baseline and after 1–3 years of follow-up using standard measures of health-related quality of life, ambulation, and activity level including the questionnaire for transfemoral amputees (Q-TFA) and the 6-minute walk test. Results — There were no major complications, and there was 1 case of superficial infection. All patients showed improved clinical outcomes, with a Q-TFA improvement range of 29–52 and a 6-minute walk test improvement range of 37–84 meters. Interpretation — It is possible to combine TKR with osseointegrated implants.
Resumo:
To strive to improve the rehabilitation program of individuals with transfemoral amputation fitted with bone-anchored prosthesis based on data from direct measurements of the load applied on the residuum we first of all need to understand the load applied on the fixation. Therefore the load applied on the residuum was first directly measured during standardized activities of daily living such as straight line level walking, ascending and descending stairs and a ramp and walking around a circle. From measuring the load in standardized activities of daily living the load was also measured during different phases of the rehabilitation program such as during walking with walking aids and during load bearing exercises.[1-15] The rehabilitation program for individuals with a transfemoral amputation fitted with an OPRA implant relies on a combination of dynamic and static load bearing exercises.[16-20] This presentation will focus on the study of a set of experimental static load bearing exercises. [1] A group of eleven individuals with unilateral transfemoral amputation fitted with an OPRA implant participated in this study. The load on the implant during the static load bearing exercises was measured using a portable system including a commercial transducer embedded in a short pylon, a laptop and a customized software package. This apparatus was previously shown effective in a proof-of-concept study published by Prof. Frossard. [1-9] The analysis of the static load bearing exercises included an analysis of the reliability as well as the loading compliance. The analysis of the loading reliability showed a high reliability between the loading sessions indicating a correct repetition of the LBE by the participants. [1, 5] The analysis of the loading compliance showed a significant lack of axial compliance leading to a systematic underloading of the long axis of the implant during the proposed experimental static LBE.
Resumo:
Background The purpose of this presentation is to outline the relevance of the categorization of the load regime data to assess the functional output and usage of the prosthesis of lower limb amputees. The objectives are • To highlight the need for categorisation of activities of daily living • To present a categorization of load regime applied on residuum, • To present some descriptors of the four types of activity that could be detected, • To provide an example the results for a case. Methods The load applied on the osseointegrated fixation of one transfemoral amputee was recorded using a portable kinetic system for 5 hours. The load applied on the residuum was divided in four types of activities corresponding to inactivity, stationary loading, localized locomotion and directional locomotion as detailed in previously publications. Results The periods of directional locomotion, localized locomotion, and stationary loading occurred 44%, 34%, and 22% of recording time and each accounted for 51%, 38%, and 12% of the duration of the periods of activity, respectively. The absolute maximum force during directional locomotion, localized locomotion, and stationary loading was 19%, 15%, and 8% of the body weight on the anteroposterior axis, 20%, 19%, and 12% on the mediolateral axis, and 121%, 106%, and 99% on the long axis. A total of 2,783 gait cycles were recorded. Discussion Approximately 10% more gait cycles and 50% more of the total impulse than conventional analyses were identified. The proposed categorization and apparatus have the potential to complement conventional instruments, particularly for difficult cases.
Resumo:
Age estimation from facial images is increasingly receiving attention to solve age-based access control, age-adaptive targeted marketing, amongst other applications. Since even humans can be induced in error due to the complex biological processes involved, finding a robust method remains a research challenge today. In this paper, we propose a new framework for the integration of Active Appearance Models (AAM), Local Binary Patterns (LBP), Gabor wavelets (GW) and Local Phase Quantization (LPQ) in order to obtain a highly discriminative feature representation which is able to model shape, appearance, wrinkles and skin spots. In addition, this paper proposes a novel flexible hierarchical age estimation approach consisting of a multi-class Support Vector Machine (SVM) to classify a subject into an age group followed by a Support Vector Regression (SVR) to estimate a specific age. The errors that may happen in the classification step, caused by the hard boundaries between age classes, are compensated in the specific age estimation by a flexible overlapping of the age ranges. The performance of the proposed approach was evaluated on FG-NET Aging and MORPH Album 2 datasets and a mean absolute error (MAE) of 4.50 and 5.86 years was achieved respectively. The robustness of the proposed approach was also evaluated on a merge of both datasets and a MAE of 5.20 years was achieved. Furthermore, we have also compared the age estimation made by humans with the proposed approach and it has shown that the machine outperforms humans. The proposed approach is competitive with current state-of-the-art and it provides an additional robustness to blur, lighting and expression variance brought about by the local phase features.
Resumo:
Microneurovascular free muscle transfer with cross-over nerve grafts in facial reanimation Loss of facial symmetry and mimetic function as seen in facial paralysis has an enormous impact on the psychosocial conditions of the patients. Patients with severe long-term facial paralysis are often reanimated with a two-stage procedure combining cross-facial nerve grafting, and 6 to 8 months later with microneurovascular (MNV) muscle transfer. In this thesis, we recorded the long-term results of MNV surgery in facial paralysis and observed the possible contributing factors to final functional and aesthetic outcome after this procedure. Twenty-seven out of forty patients operated on were interviewed, and the functional outcome was graded. Magnetic resonance imaging (MRI) of MNV muscle flaps was done, and nerve graft samples (n=37) were obtained in second stage of the operation and muscle biopsies (n=18) were taken during secondary operations.. The structure of MNV muscles and nerve grafts was evaluated using histological and immunohistochemical methods ( Ki-67, anti-myosin fast, S-100, NF-200, CD-31, p75NGFR, VEGF, Flt-1, Flk-1). Statistical analysis was performed. In our studies, we found that almost two-thirds of the patients achieved good result in facial reanimation. The longer the follow-up time after muscle transfer the weaker was the muscle function. A majority of the patients (78%) defined their quality of life improved after surgery. In MRI study, the free MNV flaps were significantly smaller than originally. A correlation was found between good functional outcome and normal muscle structure in MRI. In muscle biopsies, the mean muscle fiber diameter was diminished to 40% compared to control values. Proliferative activity of satellite cells was seen in 60% of the samples and it tended to decline with an increase of follow-up time. All samples showed intramuscular innervation. Severe muscle atrophy correlated with prolonged intraoperative ischaemia. The good long-term functional outcome correlated with dominance of fast fibers in muscle grafts. In nerve grafts, the mean number of viable axons amounted to 38% of that in control samples. The grafted nerves characterized by fibrosis and regenerated axons were thinner than in control samples although they were well vascularized. A longer time between cross facial nerve grafting and biopsy sampling correlated with a higher number of viable axons. P75Nerve Growth Factor Receptor (p75NGFR) was expressed in every nerve graft sample. The expression of p75NGFR was lower in older than in younger patients. A high expression of p75NGFR was often seen with better function of the transplanted muscle. In grafted nerve Vascular Endothelial Growth Factor (VEGF) and its receptors were expressed in nervous tissue. In conclusion, most of the patients achieved good result in facial reanimation and were satisfied with the functional outcome. The mimic function was poorer in patients with longer follow-up time. MRI can be used to evaluate the structure of the microneurovascular muscle flaps. Regeneration of the muscle flaps was still going on many years after the transplantation and reinnervation was seen in all muscle samples. Grafted nerves were characterized by fibrosis and fewer, thinner axons compared to control nerves although they were well vascularized. P75NGFR and VEGF were expressed in human nerve grafts with higher intensity than in control nerves which is described for the first time.
Resumo:
The objective of this study was to assess the utility of two subjective facial grading systems, to evaluate the etiologic role of human herpesviruses in peripheral facial palsy (FP), and to explore characteristics of Melkersson-Rosenthal syndrome (MRS). Intrarater repeatability and interrater agreement were assessed for Sunnybrook (SFGS) and House-Brackmann facial grading systems (H-B FGS). Eight video-recorded FP patients were graded in two sittings by 26 doctors. Repeatability for SFGS was from good to excellent and agreement between doctors from moderate to excellent by intraclass correlation coefficient and coefficient of repeatability. For H-B FGS, repeatability was from fair to good and agreement from poor to fair by agreement percentage and kappa coefficients. Because SFGS was at least as good in repeatability as H-B FGS and showed more reliable results in agreement between doctors, we encourage the use of SFGS over H-B FGS. Etiologic role of human herpesviruses in peripheral FP was studied by searching DNA of herpes simplex virus (HSV) -1 and -2, varicella-zoster virus (VZV), human herpesvirus (HHV) -6A, -6B, and -7, Epstein-Barr virus (EBV), and cytomegalovirus (CMV) by PCR/microarray methods in cerebrospinal fluid (CSF) of 33 peripheral FP patients and 36 controls. Three patients and five controls had HHV-6 or -7 DNA in CSF. No DNA of HSV-1 or -2, VZV, EBV, or CMV was found. Detecting HHV-7 and dual HHV-6A and -6B DNA in CSF of FP patients is intriguing, but does not allow etiologic conclusions as such. These DNA findings in association with FP and the other diseases that they accompanied require further exploration. MRS is classically defined as a triad of recurrent labial or oro-facial edema, recurrent peripheral FP, and plicated tongue. All three signs are present in the minority of patients. Edema-dominated forms are more common in the literature, while MRS with FP has received little attention. The etiology and true incidence of MRS are unknown. Characteristics of MRS were evaluated at the Departments of Otorhinolaryngology and Dermatology focusing on patients with FP. There were 35 MRS patients, 20 with FP and they were mailed a questionnaire (17 answered) and were clinically examined (14 patients). At the Department of Otorhinolaryngology, every MRS patient had FP and half had the triad form of MRS. Two patients, whose tissue biopsies were taken during an acute edema episode, revealed nonnecrotizing granulomatous findings typical for MRS, the other without persisting edema and with symptoms for less than a year. A peripheral blood DNA was searched for gene mutations leading to UNC-93B protein deficiency predisposing to HSV-1 infections; no gene mutations were found. Edema in most MRS FP patients did not dominate the clinical picture, and no progression of the disease was observed, contrary to existing knowledge. At the Department of Dermatology, two patients had triad MRS and 15 had monosymptomatic granulomatous cheilitis with frequent or persistent edema and typical MRS tissue histology. The clinical picture of MRS varied according to the department where the patient was treated. More studies from otorhinolaryngology departments and on patients with FP would clarify the actual incidence and clinical picture of the syndrome.
Resumo:
Understanding of the shape and size of different features of the human body from scanned data is necessary for automated design and evaluation of product ergonomics. In this paper, a computational framework is presented for automatic detection and recognition of important facial feature regions, from scanned head and shoulder polyhedral models. A noise tolerant methodology is proposed using discrete curvature computations, band-pass filtering, and morphological operations for isolation of the primary feature regions of the face, namely, the eyes, nose, and mouth. Spatial disposition of the critical points of these isolated feature regions is analyzed for the recognition of these critical points as the standard landmarks associated with the primary facial features. A number of clinically identified landmarks lie on the facial midline. An efficient algorithm for detection and processing of the midline, using a point sampling technique, is also presented. The results obtained using data of more than 20 subjects are verified through visualization and physical measurements. A color based and triangle skewness based schemes for isolation of geometrically nonprominent features and ear region are also presented. [DOI: 10.1115/1.3330420]