145 resultados para FLUOROSCOPY


Relevância:

10.00% 10.00%

Publicador:

Resumo:

After the discovery of ionizing radiation, its applications in various fields of science began to take significant proportions. In the case of medicine, there are the application areas in radiotherapy, diagnostic radiology and nuclear medicine. It was then necessary to create the field of radiological protection to establish the conditions necessary for the safe use of such ionizing radiation. Apply knowledge obtained during the graduation stage and in the practice of radiological protection in the areas of nuclear medicine and diagnostic radiology. In the area of nuclear medicine, tests were made in the Geiger-Muller counters (GM) and the dose calibrator (curiometer), the monitoring tests of radiation, waste management, clean of the Therapeutic room and testing the quality control of gamma-chambers. In the area of radiology, were performed tests of quality control equipment for conventional X-ray equipment and x-ray fluoroscopy, all following the rules of the National Health Surveillance Agency (ANVISA), and reporting of tests. The routine developed in the fields of nuclear medicine in hospitals has proved very useful, since the quality control of GM counters contribute to the values of possible contamination are more reliable. The control of dose calibrator enables the patient not to receive different doses of the recommended amounts, which prevents the repetition of tests and unnecessary exposure to radiation. The management of waste following the rules and laws established and required for its management. Tests for quality control of gamma chambers help to evaluate its medical performance through image. In part of diagnostic radiology, tests for quality control are performed in order to verify that the equipment is acceptable for usage or if repairs are needed. The knowledge acquired at the internship consolidated the learning of graduation course

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper consists in the evaluation of the exposure rate to ionizing radiation to which professionals working in surgical procedures which require radiological examinations are subjected. Were initially performed real-time readings of exposure rate within four distinct operating rooms during the execution of four surgical procedures that made use of fluoroscopy equipment (including three orthopedic surgeries, one in the shoulder, one in the arm, another for deployment of metal pin in the leg region, and a fourth for vascular procedure); in these surgeries were used ionization chamber detector and an electrometer. In order to check the values achieved, was made a re-evaluation of the distribution of the rate of exposure to radiation, from the surgical procedures, now with thermoluminescent dosimeters (TLDs). For this, thirty TLDs were distributed in the operating rooms, arranged in points of interest as occupation by professionals. The TLDs were prepared for thirty consecutive days, after which they were removed and replaced with new dosimeters not exposed yet. The dosimeters were subjected to reading of the rate of exposure; this procedure was repeated for four months without interruption. The quantification of the results sought primarily to convert the rate of exposure for equivalent dose rate, both in measurements with ionization chamber as in measurements with TLDs, in order to highlight the presence of the biological effect of ionizing radiation for comparisons within scientific context. Then, the results were plotted to establish the relationship between the values of equivalent dose and the distance to the central axis of the x -ray source, confirming the inverse square law for distance. Finally, the values were associated with the maximum limit recommended by the legislation for occupationally exposed individuals. The methodology for the analysis and quantification of the data in this work aims at implementing a work plan that meets ...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Determinar a taxa de sucesso da broncoscopia flexível como primeira opção na remoção de corpos estranhos das vias aéreas em adultos. MÉTODOS: Estudo retrospectivo de todos os pacientes adultos (acima de 18 anos) com aspiração de corpo estranho submetidos a broncoscopia no Hospital das Clínicas, Faculdade de Medicina da Universidade de São Paulo, em São Paulo (SP). RESULTADOS: A amostra foi constituída por 40 pacientes adultos, com média de idade de 52 anos (variação: 18-88 anos). A mediana do tempo de permanência do corpo estranho na via aérea foi de 15 dias (variação: 12 h a 10 anos). Todos os pacientes foram submetidos primeiramente a broncoscopia flexível diagnóstica. A retirada do corpo estranho por meio de broncoscopia flexível foi bem-sucedida em 33 dos pacientes (82,5%). Em 1 paciente, um objeto metálico alojado na árvore brônquica distal requereu o uso de fluoroscopia. Seis pacientes (15%) foram submetidos a broncoscopia rígida devido a dispneia induzida por corpo estranho traqueal, em 2, e porque o corpo estranho era muito grande para as pinças flexíveis, em 4. A broncoscopia falhou em apenas 1 paciente, que portanto necessitou de broncotomia. CONCLUSÕES: Embora a broncoscopia rígida seja considerada o padrão ouro na remoção de corpos estranhos na via aérea, nossa experiência mostrou que a broncoscopia flexível pode ser utilizada segura e eficientemente no diagnóstico e tratamento de pacientes adultos estáveis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

CONTEXT: About 9% of the Brazilian population has gallstones and the incidence increases significantly with aging. The choledocholithiasis is found around 15% of these patients, and a third to half of these cases presented as asymptomatic. Once the lithiasis in the common bile duct is characterized through intraoperative cholangiography, the laparoscopic surgical exploration can be done through the transcystic way or directly through choledochotomy. OBJECTIVE: To evaluate the results and outcomes of the laparoscopic treatment of common bile duct lithiasis. METHODS: Seventy consecutive patients were evaluated. They prospectively underwent the treatment of the lithiasis in the common bile duct and the exploration ways were compared according to the following parameters: criteria on their indication, success in the clearance, surgical complications. It was verified that about ½ of the choledocholithiasis carriers did not show any expression of predictive factors (clinical antecedents of jaundice and/or acute pancreatitis, compatible sonographic data and the pertaining lab tests). The laparoscopic exploration through the transcystic way is favored when there are no criteria for the practice of primary choledochotomy, which are: lithiasis in the proximal bile duct, large (over 8 mm) or numerous calculi (multiple calculosis). RESULTS: The transcystic way was employed in about 50% of the casuistic and the choledochotomy in about 30%. A high success rate (around 80%) was achieved in the clearance of the common bile duct stones through laparoscopic exploration. The transcystic way, performed without fluoroscopy or choledochoscopy, attained a low rate of success (around 45%), being 10% of those by transpapilar pushing of calculi less than 3 mm. The exploration through choledochotomy, either primary or secondary, if the latter was performed after the transcystic route failure, showed high success rate (around 95%). When the indication to choledochotomy was primary, the necessity for choledochoscopy through choledochotomy to help in the removal of the calculi was 55%. However, when choledochotomy was performed secondarily, in situations where the common bile duct diameter was larger than 6 mm, the use of choledochoscopy with the same purpose involved about 20% of the cases. There was no mortality in this series. CONCLUSION: The laparoscopic exploration of the common bile duct was related to a low rate of morbidity. Therefore, the use of laparoscopy for the treatment of the lithiasis in the common bile duct depends on the criteria for the choice of the best access, making it a safe procedure with very good results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Analisar os componentes do sinal acústico da deglutição com o auxílio de software específico. MÉTODOS: Foram avaliados 14 indivíduos saudáveis com idades variando entre 20 e 50 anos (média de 31±10 anos). A coleta de dados consistiu da captura simultânea do áudio da deglutição, por meio de um microfone, associado ao registro da imagem videofluoroscópica da deglutição. A identificação dos componentes de som e a quantificação dos tempos foram analisados posteriormente com o auxílio de software específico que possibilitou a análise simultânea entre a onda acústica e a imagem videofluoroscópica. RESULTADOS: Foram identificados três componentes de som (burst) na maioria das deglutições avaliadas. O primeiro burst apresentou tempo médio de 87,3 milissegundos (ms) para água e 78,2 para substância pastosa. O segundo burst retornou um tempo médio de 112,9 ms para água e 85,5 para consistência pastosa. O intervalo médio entre o primeiro e segundo burst foi 82,1 ms (água) e 95,3 ms (consistência pastosa), e entre o segundo e terceiro foi 339,8 ms e 322,0 ms, respectivamente para água e consistência pastosa. CONCLUSÃO: O software permitiu a visualização de três componentes do som durante a deglutição de indivíduos saudáveis e mostrou que o sinal da deglutição em indivíduos normais é altamente variável.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The knee joint is a key structure of the human locomotor system. The knowledge of how each single anatomical structure of the knee contributes to determine the physiological function of the knee, is of fundamental importance for the development of new prostheses and novel clinical, surgical, and rehabilitative procedures. In this context, a modelling approach is necessary to estimate the biomechanic function of each anatomical structure during daily living activities. The main aim of this study was to obtain a subject-specific model of the knee joint of a selected healthy subject. In particular, 3D models of the cruciate ligaments and of the tibio-femoral articular contact were proposed and developed using accurate bony geometries and kinematics reliably recorded by means of nuclear magnetic resonance and 3D video-fluoroscopy from the selected subject. Regarding the model of the cruciate ligaments, each ligament was modelled with 25 linear-elastic elements paying particular attention to the anatomical twisting of the fibres. The devised model was as subject-specific as possible. The geometrical parameters were directly estimated from the experimental measurements, whereas the only mechanical parameter of the model, the elastic modulus, had to be considered from the literature because of the invasiveness of the needed measurements. Thus, the developed model was employed for simulations of stability tests and during living activities. Physiologically meaningful results were always obtained. Nevertheless, the lack of subject-specific mechanical characterization induced to design and partially develop a novel experimental method to characterize the mechanics of the human cruciate ligaments in living healthy subjects. Moreover, using the same subject-specific data, the tibio-femoral articular interaction was modelled investigating the location of the contact point during the execution of daily motor tasks and the contact area at the full extension with and without the whole body weight of the subject. Two different approaches were implemented and their efficiency was evaluated. Thus, pros and cons of each approach were discussed in order to suggest future improvements of this methodologies. The final results of this study will contribute to produce useful methodologies for the investigation of the in-vivo function and pathology of the knee joint during the execution of daily living activities. Thus, the developed methodologies will be useful tools for the development of new prostheses, tools and procedures both in research field and in diagnostic, surgical and rehabilitative fields.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The dramatic impact that vascular diseases have on human life quality and expectancy nowadays is the reason why both medical and scientific communities put great effort in discovering new and effective ways to fight vascular pathologies. Among the many different treatments, endovascular surgery is a minimally-invasive technique that makes use of X-ray fluoroscopy to obtain real-time images of the patient during interventions. In this context radiopaque biomaterials, i.e. materials able to absorb X-ray radiation, play a fundamental role as they are employed both to enhance visibility of devices during interventions and to protect medical staff and patients from X-ray radiations. Organic-inorganic hybrids are materials that combine characteristics of organic polymers with those of inorganic metal oxides. These materials can be synthesized via the sol-gel process and can be easily applied as thin coatings on different kinds of substrates. Good radiopacity of organic-inorganic hybrids has been recently reported suggesting that these materials might find applications in medical fields where X-ray absorption and visibility is required. The present PhD thesis aimed at developing and characterizing new radiopaque organic-inorganic hybrid materials that can find application in the vascular surgery field as coatings for the improvement of medical devices traceability as well as for the production of X-ray shielding objects and garments. Novel organic-inorganic hybrids based on different polyesters (poly-lactic acid and poly-ε-caprolactone) and polycarbonate (poly-trimethylene carbonate) as the polymeric phase and on titanium oxide as the inorganic phase were synthesized. Study of the phase interactions in these materials allowed to demonstrate that Class II hybrids (where covalent bonds exists between the two phases) can be obtained starting from any kind of polyester or polycarbonate, without the need of polymer pre-functionalization, thanks to the occurrence of transesterification reactions operated by inorganic molecules on ester and carbonate moieties. Polyester based hybrids were successfully coated via dip coating on different kinds of textiles. Coated textiles showed improved radiopacity with respect to the plain fabric while remaining soft to the touch. The hybrid was able to coat single fibers of the yarn rather than coating the yarn as a whole. Openings between yarns were maintained and therefore fabric breathability was preserved. Such coatings are promising for the production of light-weight garments for X-ray protection of medical staff during interventional fluoroscopy, which will help preventing pathologies that stem from chronic X-ray exposure. A means to increase the protection capacity of hybrid-coated fabrics was also investigated and implemented in this thesis. By synthesizing the hybrid in the presence of a suspension of radiopaque tantalum nanoparticles, PDMS-titania hybrid materials with tunable radiopacity were developed and were successfully applied as coatings. A solution for enhancing medical device radiopacity was also successfully investigated. High metal radiopacity was associated with good mechanical and protective properties of organic-inorganic hybrids in the form of a double-layer coating. Tantalum was employed as the constituent of the first layer deposited on sample substrates by means of a sputtering technique. The second layer was composed of a hybrid whose constituents are well-known biocompatible organic and inorganic components, such as the two polymers PCL and PDMS, and titanium oxide, respectively. The metallic layer conferred to the substrate good X-ray visibility. A correlation between radiopacity and coating thickness derived during this study allows to tailor radiopacity simply by controlling the metal layer sputtering deposition time. The applied metal deposition technique also permits easy shaping of the radiopaque layer, allowing production of radiopaque markers for medical devices that can be unambiguously identified by surgeons during implantation and in subsequent radiological investigations. Synthesized PCL-titania and PDMS-titania hybrids strongly adhered to substrates and show good biocompatibility as highlighted by cytotoxicity tests. The PDMS-titania hybrid coating was also characterized by high flexibility that allows it to stand large substrate deformations without detaching nor cracking, thus being suitable for application on flexible medical devices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

3D video-fluoroscopy is an accurate but cumbersome technique to estimate natural or prosthetic human joint kinematics. This dissertation proposes innovative methodologies to improve the 3D fluoroscopic analysis reliability and usability. Being based on direct radiographic imaging of the joint, and avoiding soft tissue artefact that limits the accuracy of skin marker based techniques, the fluoroscopic analysis has a potential accuracy of the order of mm/deg or better. It can provide fundamental informations for clinical and methodological applications, but, notwithstanding the number of methodological protocols proposed in the literature, time consuming user interaction is exploited to obtain consistent results. The user-dependency prevented a reliable quantification of the actual accuracy and precision of the methods, and, consequently, slowed down the translation to the clinical practice. The objective of the present work was to speed up this process introducing methodological improvements in the analysis. In the thesis, the fluoroscopic analysis was characterized in depth, in order to evaluate its pros and cons, and to provide reliable solutions to overcome its limitations. To this aim, an analytical approach was followed. The major sources of error were isolated with in-silico preliminary studies as: (a) geometric distortion and calibration errors, (b) 2D images and 3D models resolutions, (c) incorrect contour extraction, (d) bone model symmetries, (e) optimization algorithm limitations, (f) user errors. The effect of each criticality was quantified, and verified with an in-vivo preliminary study on the elbow joint. The dominant source of error was identified in the limited extent of the convergence domain for the local optimization algorithms, which forced the user to manually specify the starting pose for the estimating process. To solve this problem, two different approaches were followed: to increase the optimal pose convergence basin, the local approach used sequential alignments of the 6 degrees of freedom in order of sensitivity, or a geometrical feature-based estimation of the initial conditions for the optimization; the global approach used an unsupervised memetic algorithm to optimally explore the search domain. The performances of the technique were evaluated with a series of in-silico studies and validated in-vitro with a phantom based comparison with a radiostereometric gold-standard. The accuracy of the method is joint-dependent, and for the intact knee joint, the new unsupervised algorithm guaranteed a maximum error lower than 0.5 mm for in-plane translations, 10 mm for out-of-plane translation, and of 3 deg for rotations in a mono-planar setup; and lower than 0.5 mm for translations and 1 deg for rotations in a bi-planar setups. The bi-planar setup is best suited when accurate results are needed, such as for methodological research studies. The mono-planar analysis may be enough for clinical application when the analysis time and cost may be an issue. A further reduction of the user interaction was obtained for prosthetic joints kinematics. A mixed region-growing and level-set segmentation method was proposed and halved the analysis time, delegating the computational burden to the machine. In-silico and in-vivo studies demonstrated that the reliability of the new semiautomatic method was comparable to a user defined manual gold-standard. The improved fluoroscopic analysis was finally applied to a first in-vivo methodological study on the foot kinematics. Preliminary evaluations showed that the presented methodology represents a feasible gold-standard for the validation of skin marker based foot kinematics protocols.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gleno-humeral joint (GHJ) is the most mobile joint of the human body. This is related to theincongr uence between the large humeral head articulating with the much smaller glenoid (ratio 3:1). The GHJ laxity is the ability of the humeral head to be passively translated on the glenoid fossa and, when physiological, it guarantees the normal range of motion of the joint. Three-dimensional GHJ linear displacements have been measured, both in vivo and in vitro by means of different instrumental techniques. In vivo gleno-humeral displacements have been assessed by means of stereophotogrammetry, electromagnetic tracking sensors, and bio-imaging techniques. Both stereophotogrammetric systems and electromagnetic tracking devices, due to the deformation of the soft tissues surrounding the bones, are not capable to accurately assess small displacements, such as gleno-humeral joint translations. The bio-imaging techniques can ensure for an accurate joint kinematic (linear and angular displacement) description, but, due to the radiation exposure, most of these techniques, such as computer tomography or fluoroscopy, are invasive for patients. Among the bioimaging techniques, an alternative which could provide an acceptable level of accuracy and that is innocuous for patients is represented by magnetic resonance imaging (MRI). Unfortunately, only few studies have been conducted for three-dimensional analysis and very limited data is available in situations where preset loads are being applied. The general aim of this doctoral thesis is to develop a non-invasive methodology based on open-MRI for in-vivo evaluation of the gleno-humeral translation components in healthy subjects under the application of external loads.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lo scopo di questa tesi è lo studio degli aspetti procedurali e dosimetrici in angiografie periferiche che utilizzano la CO2 come mezzo di contrasto. La tecnica angiografica consiste nell’imaging radiologico di vasi sanguigni tramite l’iniezione di un mezzo di contrasto, e il suo uso è in costante incremento a causa dell’aumento di pazienti con malattie vascolari. I mezzi di contrasto iodati sono i più comunemente utilizzati e permettono di ottenere immagini di ottima qualità, ma presentano il limite di una elevata nefrotossicità. La CO2 è considerata un’interessante alternativa al mezzo iodato, per la sua acclarata biocompatibilità, soprattutto per pazienti con elevati fattori di rischio (diabete e/o insufficienza renale). Il suo utilizzo presenta comunque alcuni aspetti problematici, dovuti allo stato gassoso e al basso contrasto intrinseco rispetto alla soluzione iodata. Per quest’ultimo motivo si ritiene generalmente che l’utilizzo della CO2 comporti un aumento di dose rispetto ai mezzi di contrasto tradizionali. Il nostro studio, effettuato su diversi apparati radiologici, ha dimostrato che i parametri di emissione radiologica sono gli stessi per i protocolli di angiografia tradizionale, con iodio, e quelli che utilizzano CO2. Questa evidenza suggerisce che i protocolli CO2 operino solo sul trattamento delle immagini ottenute e non sulla modalità di acquisizione, e dal punto di vista dosimetrico l’angiografia con CO2 è riconducibile all’angiografia tradizionale. L’unico fattore che potrebbe portare a un effettivo incremento di dose al paziente è un allungamento dei tempi di scopia e di procedura, che andrebbe verificato con una campagna di misure in ambito clinico. Sulla base della stessa evidenza, si ritiene che la visualizzazione della CO2 possa essere ulteriormente migliorata attraverso l’ottimizzazione dei parametri di emissione radiologica (kVp, frame rate e durata degli impulsi) attualmente predisposti per l’uso di mezzi di contrasto iodati.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The authors describe a modification of the medial branch kryorhizotomy technique for the treatment of lumbar facet joint syndrome using a fluoroscopy-based laser-guided method. A total of 32 patients suffering from lumbar facet joint syndrome confirmed by positive medial nerve block underwent conventional or laser-guided kryorhizotomy. The procedural time (20.6 +/- 1.0 vs 16.3 +/- 0.9 minutes, p < 0.01), fluoroscopy time (54.1 +/- 3.5 vs 28.2 +/- 2.4 seconds, p < 0.01), radiation dose (407.5 +/- 32.0 vs 224.1 +/- 20.3 cGy/cm(2), p < 0.01), and patient discomfort during the procedure (7.1 +/- 0.4 vs 5.2 +/- 0.4 on the visual analog scale, p < 0.01) were significantly reduced in the laser-guided group. There was a tendency for a better positioning accuracy when the laser guidance method was used (3.0 +/- 0.3 vs 2.2 +/- 0.3 mm of deviation from the target points, p > 0.05). No difference in the outcome was observed between the 2 groups of patients (visual analog scale score 3.5 +/- 0.2 vs 3.3 +/- 0.3, p > 0.05). This improved minimally invasive surgical technique offers advantages to conventional fluoroscopy-based kryorhizotomy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nerve blocks and radiofrequency neurotomy of the nerves supplying the cervical zygapophyseal joints are validated tools for diagnosis and treatment of chronic neck pain, respectively. Unlike fluoroscopy, ultrasound may allow visualization of the target nerves, thereby potentially improving diagnostic accuracy and therapeutic efficacy of the procedures. The aims of this exploratory study were to determine the ultrasound visibility of the target nerves in chronic neck pain patients and to describe the variability of their course in relation to the fluoroscopically used bony landmarks.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

When conservative treatment modalities provide inadequate relief, interventional techniques play an important role in the management of chronic pain patients. They are performed in diagnostic or therapeutic intention (or both) and either directly target the pain generating anatomic structure (e.g. intraarticular joint injections) or the neural structures which are thought to mediate the experience of pain (e.g. facet joint nerve blocks, spinal cord stimulation). In order to enhance precision and patient safety, these interventions are performed with image guidance; of which fluoroscopy is the most commonly used technique. CT- or Ultrasound-guided techniques are also performed. This article is an overview of the indications and results of the most commonly performed interventional techniques used in chronic pain treatment with focus on spinal interventional procedures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background The evaluation of the hepatic parenchyma in patients with chronic liver disease is important to assess the extension, localization and relationship with adjacent anatomical structures of possible lesions. This is usually performed with conventional abdominal ultrasound, CT-scan or magnetic resonance imaging. In this context, the feasibility and the safety of intravascular ultrasound in the liver have not been assessed yet. Methods We tested the safety and performance of an intracardiac echography (ICE) catheter applied by a transjugular approach into the hepatic veins in patients with chronic liver disease undergoing hepatic hemodynamic measurements. Results Five patients were enrolled in this pilot study. The insertion of the ICE catheter was possible into the right and middle, but not into the left hepatic vein. The position of the ICE was followed using fluoroscopy and external conventional ultrasound. Accurate imaging of focal hepatic parenchymal lesions, Doppler ultrasound of surrounding blood vessels and assessment of liver surface and ascites were achieved without complications. Conclusions This study demonstrated that a diagnostic approach using an ICE device inserted in the hepatic veins is feasible, safe and well tolerated. However, it remains for the moment only an experimental investigative tool. Whether ICE adds further information regarding parenchymal lesions and associated vascular alterations as compared to other techniques, needs additional investigation.