The exchange interaction of Gd adjacent to Fe has been characterized by transport measurements on a double spin valve with a Fe/Gd/Fe trilayer as the middle layer. Our measurements show that the ferromagnetism of the Gd is enhanced by the presence of the Fe, and it remains ferromagnetic over its Curie temperature up to a thickness no smaller than 1 nm adjacent to the Fe. This thickness is more than double what has been reported before. Additionally, the saturation magnetization of the thin Gd layer sandwiched in Fe was found to be half of its bulk value. This reduced magnetization does not seem to be related to the proximity of Fe but rather to the incomplete saturation of Gd even for very high fields

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Quais propriedades magnéticas são modificadas quando se agrupam átomos de Fe/Co para formar estruturas quasi-2D, se comparadas aos nanofios (quasi-1D) de FexCo1-x? E como estas propriedades reagem com a variação da proporção de Fe/Co nos aglomerados? A fim de responder a estas questões, trímeros de FexCo1-x depositados em Pt(111) são investigados utilizando o método de primeiros princípios Real Space-Linear Muffin-Tin Orbital-Atomic Sphere Approximation (RS-LMTO-ASA) no âmbito da Teoria do Funcional da Densidade (DFT). Diferentes configurações de trímeros triangulares são consideradas, variando-se as posições e a concentração dos átomos de Fe/Co. Neste trabalho, demonstra-se a ocorrência de uma tendência não-linear estritamente decrescente dos momentos orbitais médios como função da concentração de Fe, distinta do encontrado tanto para os nanofios de FexCo1-x (dependência linear) quanto para a monocamada correspondente (dependência não-linear). Os resultados obtidos mostram ainda que os momentos orbitais variam com o ambiente local e com a direção de magnetização, especialmente quando associados aos átomos de Co, em concordância com publicações anteriores. A mudança de dimensionalidade quasi-1D (nanofios) para quasi-2D (trímeros compactos) não afeta o comportamento dos momentos de spin, que permanecem descritos por uma função linear com respeito à proporção de Fe/Co. Ambos o formato e a concentração de Fe nos sistemas apresentam um papel importante nos valores de energia de anisotropia magnética. Em adição, observou-se que o subtrato de Pt opera ativamente na definição das propriedades magnéticas dos aglomerados. Embora todas as configurações lineares e compactas dos aglomerados de FexCo1-x sejam estáveis e exibam interações fortemente ferromagnéticas entre os primeiros vizinhos, nem todas revelaram o ordenamento colinear como estado fundamental, apresentando uma interação de Dzyaloshinskii-Moriya não-desprezível induzida pelo acoplamento spin-órbita. Estes casos específicos são: o trímero triangular de Co puro e o trímero linear (nanofio) de Fe puro, para o qual foi verificado o acoplamento do tipo Ruderman-Kittel-Kasuya-Yosida entre os átomos de Fe constituintes. Os resultados obtidos contribuem para o entendimento de quais mecanismos definem o magnetismo nos trímeros de FexCo1-x/Pt(111), e discutem as questões presentes atualmente na literatura no contexto destes sistemas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The magnetization reversal of two-dimensional arrays of parallel ferromagnetic Fe nanowires embedded in nanoporous alumina templates has been studied. By combining bulk magnetization measurements (superconducting quantum interference device magnetometry) with field-dependent magnetic force microscopy (MFM), we have been able to decompose the macroscopic hysteresis loop in terms of the irreversible magnetic responses of individual nanowires. The latter are found to behave as monodomain ferromagnetic needles, with hysteresis loops displaced (asymmetric) as a consequence of the strong dipolar interactions between them. The application of field-dependent MFM provides a microscopic method to obtain the hysteresis curve of the array, by simply registering the fraction of up and down magnetized wires as a function of applied field. The observed deviations from the rectangular shape of the macroscopic hysteresis loop of the array can be ascribed to the spatial variation of the dipolar field through the inhomogeneously filled membrane. The system studied proves to be an excellent example of the two-dimensional classical Preisach model, well known from the field of hysteresis modeling and micromagnetism.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Atomic contacts made of ferromagnetic metals present zero-bias anomalies in the differential conductance due to the Kondo effect. These systems provide a unique opportunity to perform a statistical analysis of the Kondo parameters in nanostructures since a large number of contacts can be easily fabricated using break-junction techniques. The details of the atomic structure differ from one contact to another so a large number of different configurations can be statistically analyzed. Here we present such a statistical analysis of the Kondo effect in atomic contacts made from the ferromagnetic transition metals Ni, Co, and Fe. Our analysis shows clear differences between materials that can be understood by fundamental theoretical considerations. This combination of experiments and theory allows us to extract information about the origin and nature of the Kondo effect in these systems and to explore the influence of geometry and valence in the Kondo screening of atomic-sized nanostructures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Magnetism and magnetic materials have been playing a lead role in the day to day life of human beings. The human kind owes its gratitude to the ‘lodestone’ meaning ‘leading stone’ which lead to the discovery of nations and the onset of modern civilizations. If it was William Gilbert, who first stated that ‘earth was a giant magnet’, then it was the turn of Faraday who correlated electricity and magnetism. Magnetic materials find innumerable applications in the form of inductors, read and write heads, motors, storage devices, magnetic resonance imaging and fusion reactors. Now the industry of magnetic materials has almost surpassed the semiconductor industry and this speaks volumes about its importance. Extensive research is being carried out by scientists and engineers to remove obsolescence and invent new devices. Though magnetism can be categorized based on the response of an applied magnetic field in to diamagnetic, paramagnetic, ferromagnetic, ferrimagnetic and antiferromagnetic; it is ferrimagnetic, ferromagnetic and antiferromagnetic materials which have potential applications. The present thesis focusses on these materials, their composite structures and different ways and means to modify their properties for useful applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introducción La ventilación mecánica es fundamental en el manejo de la falla respiratoria aguda, actualmente no existe consenso sobre el momento exacto de extubación. Este estudio describe el comportamiento de la escala OMAHA+ en nuestra institución. Objetivo Principal Describir los desenlaces clínicos relacionados con la escala OMAHA+ durante la extubación de los pacientes de las unidades de cuidado intensivo del hospital universitario. Métodos Estudio descriptivo, retrospectivo, basado en el registro de la escala OMAHA+ de 68 pacientes durante el proceso de extubación en las Unidades de cuidado intensivo adulto de la Fundación Santa Fe de Bogotá durante Agosto de 2014 a Mayo de 2015. Resultados Se encontraron valores gasométricos cercanos a la normalidad, con una PaO2/FiO2 media de 261 (DS 60,6), SaO2 media de 96% (DS 2%), media de lactato sérico de 1.5 mmol/L (DS 1,2 mmol/L), con signos vitales normales. La causa más común de ingreso a UCI fue Neumonía, seguida por cirugía cardiaca y abdominal. Las medias de parámetros ventilatorios al momento de extubación fueron; PEEP de 6 (DS 0,8), volumen corriente de 8ml/Kg (DS 1,4 ml/Kg), índice de Tobín de 34 (DS 11,9), test de fuga positivo 94%, y sólo una extubación fallida. Conclusiones La escala OMAHA+ puede ser una herramienta útil, aplicable y fácilmente reproducible en los pacientes con soporte ventilatorio mecánico invasivo previo al proceso de extubación, con baja proporción de fallo. Estos resultados deben ser evaluados en estudios prospectivos.