843 resultados para FAILURE
Resumo:
Heart failure (HF) incidence in diabetes in both the presence and absence of CHD is rising. Prospective population-based studies can help describe the relationship between HbA(1c), a measure of glycaemia control, and HF risk. We studied the incidence of HF hospitalisation or death among 1,827 participants in the Atherosclerosis Risk in Communities (ARIC) study with diabetes and no evidence of HF at baseline. Cox proportional hazard models included age, sex, race, education, health insurance status, alcohol consumption, BMI and WHR, and major CHD risk factors (BP level and medications, LDL- and HDL-cholesterol levels, and smoking). In this population of persons with diabetes, crude HF incidence rates per 1,000 person-years were lower in the absence of CHD (incidence rate 15.5 for CHD-negative vs 56.4 for CHD-positive, p < 0.001). The adjusted HR of HF for each 1% higher HbA(1c) was 1.17 (95% CI 1.11-1.25) for the non-CHD group and 1.20 (95% CI 1.04-1.40) for the CHD group. When the analysis was limited to HF cases which occurred in the absence of prevalent or incident CHD (during follow-up) the adjusted HR remained 1.20 (95% CI 1.11-1.29). These data suggest HbA(1c) is an independent risk factor for incident HF in persons with diabetes with and without CHD. Long-term clinical trials of tight glycaemic control should quantify the impact of different treatment regimens on HF risk reduction.
Resumo:
OBJECTIVE-This study sought to investigate an association of HbA1c (A1C) with incident heart failure among individuals without diabetes and compare it to fasting glucose. RESEARCH DESIGN AND METHODS-We studied 11,057 participants of the Atherosclerosis Risk in Communities (ARIC) Study without heart failure or diabetes at baseline and estimated hazard ratios of incident heart failure by categories of A1C (<5.0, 5.0-5.4 [reference], 5 5-59, and 6.0-6.4%) and fasting glucose (<90, 90-99 [reference], 100-109, and 110-125 mg/dl) using Cox proportional hazards models. RESULTS-A total of 841 cases of incident heart failure hospitalization or deaths (International Classification of Disease, 9th/10th Revision, 428/150) occurred during a median follow-up of 14.1 years (incidence rate 5.7 per 1,000 person-years). After the adjustment for covariates including fasting glucose, the hazard ratio of incident heart failure was higher in individuals with A1C 6.0-6.4% (1.40 [95% CI, 1 09-1.79]) and 5.5-6.0% (1.16 [0.98-1 37]) as compared with the reference group. Similar results were observed when adjusting for insulin level or limiting to heart failure cases without preceding coronary events or developed diabetes during follow-up. In contrast, elevated fasting glucose was not associated with heart failure after adjustment for covariates and A1C. Similar findings were observed when the top quartile (A1C, 5.7-6.4%, and fasting glucose, 108-125 mg/dl) was compared with the lowest quartile (<5 2% and <95 mg/dl, respectively). CONCLUSIONS-Elevated A1C (>= 5.5-6 0%) was associated with incident heart failure in a middle-aged population without diabetes, suggesting that chronic hyperglycemia prior to the development of diabetes contributes to development of heart failure. Diabetes 59:2020-2026, 2010
Resumo:
Emotions play a significant role in the workplace, and considerable attention has been given to the study of employee emotions. Customers also play a central function in organizations, but much less is known about customer emotions. This chapter reviews the growing literature on customer emotions in employee–customer interfaces with a focus on service failure and recovery encounters, where emotions are heightened. It highlights emerging themes and key findings, addresses the measurement, modeling, and management of customer emotions, and identifies future research streams. Attention is given to emotional contagion, relationships between affective and cognitive processes, customer anger, customer rage, and individual differences.
Resumo:
Introduction: Among patients with congestive heart failure (CHF) both obstructive and central sleep apnea (SA) are associated with increased sympathetic activity. However, the day-night pattern of cardiac autonomic nervous system modulation in CHF patients with and without sleep apnea is unknown. Material and methods: Twenty-five CHF patients underwent polysomnography with simultaneous beat-to-beat blood pressure (Portapres), respiration and electrocardiogram monitoring. Patients were divided according to the presence (SA, n=17) and absence of SA (NoSA, n=8). Power spectral analyses of heart rate variability (HRV) and spontaneous baroreflex sensitivity (BRS) were determined in periods with stable breathing while awake at 6 AM, 10 AM, 10 PM, as well as during stage 2 sleep. In addition, muscle sympathetic nerve activity (MSNA) was evaluated at 10 AM. Results: RR variance, low-frequency (LF), high-frequency (HF) powers of HRV, and BRS were significantly lower in patients with SA compared with NoSA in all periods. HF power, a marker of vagal activity, increased during sleep in patients with NoSA but in contrast did not change across the 24-hour period in patients with SA. MSNA was significantly higher in patients with SA compared with NoSA. RR variance, LF and HF powers correlated inversely with simultaneous MSNA (r=-0.64, -0.61, and -0.61 respectively; P < 0.01). Conclusions: Patients with CHF and SA present a reduced and blunted cardiac autonomic modulation across the 24-hour period. These findings may help to explain the increased cardiovascular risk in patients with CHF and SA. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
Resumo:
The following are notes that have been distributed by me over the last few years to students in Environmental Economics at The University of Queensland. They give particular attention to whether externalities are Pareto or Kaldor-Hicks relevant from a policy point of view. Externalities are Kaldor-Hicks or Pareto irrelevant if no change is possible for which gainers could compensate losers. Both absolute and marginal externalities may be Kaldor-Hicks relevant. Infra-marginal negative externalities are often, but not always, Kaldor-Hicks irrelevant. There are at least two cases where such externalities can be relevant. First, the absolute impact of the negative externality may be so great that the source of the externality should be eliminated. Secondly, if the externality arises from production, its nature may depend on the type of production technique adopted. Although for the technique adopted, an infra-marginal negative externality occurs. That is Paretian irrelevant given that choice of this technique is the only available possibility, alternative techniques may actually be available in practice. Some of these may generate even smaller total external effects and be socially preferable. Both cases are outlined and illustrated in these notes. The analysis reveals the dangers of relying on marginalism for deciding on environmental policy. Total (external) effects are often of great social and economic importance and appropriate social choices cannot be made on the basis of marginalism alone.
Resumo:
Purpose: Chipping within veneering porcelain has resulted in high clinical failure rates for implant-supported zirconia (yttria-tetragonal zirconia polycrystals [Y-TZP]) bridges. This study evaluated the reliability and failure modes of mouth-motion step-stress fatigued implant-supported Y-TZP versus palladium-silver alloy (PdAg) three-unit bridges. Materials and Methods: Implant-abutment replicas were embedded in polymethylmethacrylate resin. Y-TZP and PdAg frameworks, of similar design (n = 21 each), were fabricated, veneered, cemented (n = 3 each), and Hertzian contact-tested to obtain ultimate failure load. In each framework group, 18 specimens were distributed across three step-stress profiles and mouth-motion cyclically loaded according to the profile on the lingual slope of the buccal cusp of the pontic. Results: PdAg failures included competing flexural cracking at abutment and/or connector area and chipping, whereas Y-TZP presented predominantly cohesive failure within veneering porcelain. Including all failure modes, the reliability (two-sided at 90% confidence intervals) for a ""mission"" of 50,000 and 100,000 cycles at 300 N load was determined (Alta Pro, Reliasoft, Tucson, AZ, USA). No difference in reliability was observed between groups for a mission of 50,000. Reliability remained unchanged for a mission of 100,000 for PdAg, but significantly decreased for Y-TZP. Conclusions: Higher reliability was found for PdAg for a mission of 100,000 cycles at 300 N. Failure modes differed between materials.
Resumo:
Objectives: To evaluate the effect of framework design on the fatigue life and failure modes of metal ceramic (MC, Ni-Cr alloy core, VMK 95 porcelain veneer), glass-infiltrated alumina (ICA, In-Ceram Alumina/VM7), and veneered yttria-stabilized tetragonal zirconia polycrystals (Y-TZP, IPSe.max ZirCAD/IPS e.max,) crowns. Methods: Sixty composite resin tooth replicas of a prepared maxillary first molar were produced to receive crowns systems of a standard (MCs, ICAs, and Y-TZPs, n = 10 each) or a modified framework design (MCm, ICAm, and Y-TZPm, n = 10 each). Fatigue loading was delivered with a spherical steel indenter (3.18 mm radius) on the center of the occlusal surface using r-ratio fatigue (30-300 N) until completion of 10(6) cycles or failure. Fatigue was interrupted every 125,000 cycles for damage evaluation. Weibull distribution fits and contour plots were used for examining differences between groups. Failure mode was evaluated by light polarized and SEM microscopy. Results: Weibull analysis showed the highest fatigue life for MC crowns regardless of framework design. No significant difference (confidence bound overlaps) was observed between ICA and Y-TZP with or without framework design modification. Y-TZPm crowns presented fatigue life in the range of MC crowns. No porcelain veneer fracture was observed in the MC groups, whereas ICAs presented bulk fracture and ICAm failed mainly through the veneer. Y-TZP crowns failed through chipping within the veneer, without core fractures. Conclusions: Framework design modification did not improve the fatigue life of the crown systems investigated. Y-TZPm crowns showed comparable fatigue life to MC groups. Failure mode varied according to crown system. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Objectives To compare the reliability of the disto-facial (DF) and mesio-lingual (ML) cusps of an anatomically correct zirconia (Y-TZP) crown system The research hypotheses tested were (1) fatigue reliability and failure mode are similar for the ML and DF cusps, (2) failure mode of one cusp does not affect the failure of the other Methods The average dimensions of a mandibular first molar crown were imported into CAD software, a tooth preparation was modelled by 1 5 mm marginal high reduction of proximal walls and occlusal surface by 2 0 mm The CAD-based tooth preparation was milled and used as a die to fabricate crowns (n = 14) with porcelain veneer on a 0 5 mm Y-TZP core. Crowns were cemented on composite reproductions of the tooth preparation The crowns were step-stress mouth motion fatigued with sliding (0 7 mm) a tungsten-carbide indenter of 6 25 mm diameter down on the inclines of either the DF or ML cusps Use level probability Weibull curve with use stress of 200 N and the reliability for completion of a mission of 50,000 cycles at 200 N load were calculated Results Reliability for a 200 N at 50,000 cycles mission was not different between tested cusps SEM imaging showed large cohesive failures within the veneer for the ML and smaller for the DF Fractures originated from the contact area regardless of the cusp loaded Conclusion No significant difference on fatigue reliability was observed between the DF compared to the ML cusp Fracture of one cusp did not affect the other (c) 2010 Elsevier Ltd All rights reserved
Resumo:
Purpose: The aim of this research was to evaluate the fatigue behavior and reliability of monolithic computer-aided design/computer-assisted manufacture (CAD/CAM) lithium disilicate and hand-layer-veneered zirconia all-ceramic crowns. Materials and Methods: A CAD-based mandibular molar crown preparation, fabricated using rapid prototyping, served as the master die. Fully anatomically shaped monolithic lithium disilicate crowns (IPS e.max CAD, n = 19) and hand-layer-veneered zirconia-based crowns (IPS e.max ZirCAD/Ceram, n = 21) were designed and milled using a CAD/CAM system. Crowns were cemented on aged dentinlike composite dies with resin cement. Crowns were exposed to mouth-motion fatigue by sliding a WC-indenter (r = 3.18 mm) 0.7 mm lingually down the distobuccal cusp using three different step-stress profiles until failure occurred. Failure was designated as a large chip or fracture through the crown. If no failures occurred at high loads (> 900 N), the test method was changed to staircase r ratio fatigue. Stress level probability curves and reliability were calculated. Results: Hand-layer-veneered zirconia crowns revealed veneer chipping and had a reliability of < 0.01 (0.03 to 0.00, two-sided 90% confidence bounds) for a mission of 100,000 cycles and a 200-N load. None of the fully anatomically shaped CAD/CAM-fabricated monolithic lithium disilicate crowns failed during step-stress mouth-motion fatigue (180,000 cycles, 900 N). CAD/CAM lithium disilicate crowns also survived r ratio fatigue (1,000,000 cycles, 100 to 1,000 N). There appears to be a threshold for damage/bulk fracture for the lithium disilicate ceramic in the range of 1,100 to 1,200 N. Conclusion: Based on present fatigue findings, the application of CAD/CAM lithium disilicate ceramic in a monolithic/fully anatomical configuration resulted in fatigue-resistant crowns, whereas hand-layer-veneered zirconia crowns revealed a high susceptibility to mouth-motion cyclic loading with early veneer failures. Int J Prosthodont 2010; 23: 434-442.