975 resultados para Evanescent wave fibre optic sensors


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cardiovascular health of the human population is a major concern for medical clinicians, with cardiovascular diseases responsible for 48% of all deaths worldwide, according to the World Health Organisation. Therefore the development of new practicable and economical diagnostic tools to scrutinise the cardiovascular health of humans is a major driver for clinicians. We offer a new technique to obtain seismocardiographic signals covering both ballistocardiography (below 20Hz) and audible heart sounds (20Hz upwards). The detection scheme is based upon an array of curvature/displacement sensors using fibre optic long period gratings interrogated using a variation of the derivative spectroscopy interrogation technique. © 2014 SPIE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We demonstrate an all-fiber passively Q-switched erbiumdoped fiber laser (EDFL) using a gold-nanosphere (GNS) based saturable absorber (SA) with evanescent field interaction. Using the interaction of evanescent field for fabricating SAs, long nonlinear interaction length of evanescent wave and GNSs can be achieved. The GNSs are synthesized from mixing solution of chloroauricacid (HAuCl4) and sodium citrate by the heating effects of the microfiber's evanescent field radiation. The proposed passively Q-switched EDFL could give output pulses at 1562 nm with pulse width of 1.78 μs, a repetition rate of 58.1 kHz, a pulse energy of 133 nJ and a output power of 7.7 mWwhen pumped by a 980 nm laser diode of 237 mW. © 2014 Optical Society of America.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report a distinctive polarisation mode coupling behaviour of tilted fibre Bragg gratings (TFBGs) with tilted angle exceeding 45°. The ex-45° TFBGs exhibit pronounced polarisation mode splitting resulted from grating structure asymmetry induced birefringence. We have studied and analysed the property of ex-45° TFBGs under transverse load applied to their equivalent fast- and slow-axis. The results show that the coupling between the orthogonally polarised modes takes place only when the load is applied to its fast-axis, giving a prominent directional loading response. This transverse load related polarisation property may be exploitable for implementation of optical fibre vector sensors capable of measuring the magnitude and orientation of the applied transverse load.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new type of fibre-optic biochemical concentration sensor based on a polymer optical fibre Bragg grating (POFBG) is proposed. The wavelength of the POFBG varies as a function of analyte concentration. The feasibility of this sensing concept is demonstrated by a saline concentration sensor. When polymer fibre is placed in a water based solution the process of osmosis takes place in this water-fibre system. An osmotic pressure which is proportional to the solution concentration, will apply to the fibre in addition to the hydraulic pressure. It tends to drive the water content out of the fibre and into the surrounding solution. When the surrounding solution concentration increases the osmotic pressure increases to drive the water content out of the fibre, consequently increasing the differential hydraulic pressure and reducing the POFBG wavelength. This process will stop once there is a balance between the osmotic pressure and the differential hydraulic pressure. Similarly when the solution concentration decreases the osmotic pressure decreases, leading to a dominant differential hydraulic pressure which drives the water into the fibre till a new pressure balance is established. Therefore the water content in the polymer fibre - and consequently the POFBG wavelength - depends directly on the solution concentration. A POFBG wavelength change of 0.9 nm was measured for saline concentration varying from 0 to 22%. For a wavelength interrogation system with a resolution of 1 pm, a measurement of solution concentration of 0.03% can be expected.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Graphene-based silica fiber-optic sensors, with high sensitivity, fast response, and low cost, have shown great promise for gas sensing applications. In this letter, by covering a monolayer of p-doped graphene on a D-shaped microstructured polymer fiber Bragg grating (FBG), we propose and demonstrate a novel biochemical probe sensor, the graphene-based D-shaped polymer FBG (GDPFBG). Due to the graphene-based surface evanescent field enhancement, this sensor shows high sensitivity to detect surrounding biochemical parameters. By monitoring the Bragg peak locations of the GDPFBG online, human erythrocyte (red blood cell) solutions with different cellular concentrations ranging from 0 to 104 ppm were detected precisely, with the maximum resolution of sub-ppm. Such a sensor is structurally compact, is clinically acceptable, and provides good recoverability, offering a state-of-the-art polymer-fiber-based sensing platform for highly sensitive in situ and in vivo cell detection applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Distortion is one type of defect in the weld, which is troublesome for some reasons, especially in thin plate welding. Distortion was found in fibre laser welding processing for 0.7mm thickness Ti6Al4V plate. The purpose of this paper is to understand and evaluate the effect of distortion on stress level by FEA and tensile test. A group of 0.7mm Ti6Al4V plates welded using continuous wave fibre laser. FEA models were established for fibre laser welded Ti6Al4V in abaqus 6.7. © (2011) Trans Tech Publications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Within the context of the overall ecological working programme Dynamics of Antarctic Marine Shelf Ecosystems (DynAMo) of the PS96 (ANT-XXXI/2) cruise of RV "Polarstern" to the Weddell Sea (Dec 2015 to Feb 2016), seabed imaging surveys were carried out along drift profiles by means of the Ocean Floor Observation System (OFOS) of the Alfred Wegener Institute, Helmholtz Centre for Polar and Marine Research (AWI) Bremerhaven. The setup and mode of deployment of the OFOS was similar to that described by Bergmann and Klages (2012, doi:10.1016/j.marpolbul.2012.09.018). OFOS is a surface-powered gear equipped with two downward-looking cameras installed side-by-side: one high-resolution, wide-angle still camera (CANON® EOS 5D Mark III; lens: Canon EF 24 f/1.4L II, f stop: 13, exposure time: 1/125 sec; in-air view angles: 74° (horizontal), 53° (vertical), 84° (diagonal); image size: 5760 x 3840 px = 21 MPix; front of pressure resistant camera housing consisting of plexiglass dome port) and one high-definition color video camera (SONY® FCB-H11). The system was vertically lowered over the stern of the ship with a broadband fibre-optic cable, until it hovers approximately 1.5 m above the seabed. It was then towed after the slowly sailing ship at a speed of approximately 0.5 kn (0.25 m/s). The ship's Global Acoustic Positioning System (GAPS), combining Ultra Short Base Line (USBL), Inertial Navigation System (INS) and satellite-based Global Positioning System (GPS) technologies, was used to gain highly precise underwater position data of the OFOS. During the profile, OFOS was kept hanging at the preferred height above the seafloor by means of the live video feed and occasional minor cable-length adjustments with the winch to compensate small-scale bathymetric variations in seabed morphology. Information on water depth and height above the seafloor were continuously recorded by means of OFOS-mounted sensors (GAPS transponder, Tritech altimeter). Three lasers, which are placed beside the still camera, emit parallel beams and project red light points, arranged as an equilateral triangle with a side length of 50 cm, in each photo, thus providing a scale that can be used to calculate the seabed area depicted in each image and/or measure the size of organisms or seabed features visible in the image. In addition, the seabed area depicted was estimated using altimeter-derived height above seafloor and optical characteristics of the OFOS still camera. In automatic mode, a seabed photo, depicting an area of approximately 3.45 m**2 (= 2.3 m x 1.5 m; with variations depending on the actual height above ground), was taken every 30 seconds to obtain series of "TIMER" stills distributed at regular distances along the profiles that vary in length depending on duration of the cast. At a ship speed of 0.5 kn, the average distance between seabed images was approximately 5 m. Additional "HOTKEY" photos were taken from interesting objects (organisms, seabed features, such as putative iceberg scours) when they appeared in the live video feed (which was also recorded, in addition to the stills, for documentation and possible later analysis). If any image from this collection is used, please cite the reference as given above.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ageing and deterioration of infrastructure is a challenge facing transport authorities. In
particular, there is a need for increased bridge monitoring in order to provide adequate
maintenance and to guarantee acceptable levels of transport safety. The Intelligent
Infrastructure group at Queens University Belfast (QUB) are working on a number of aspects
of infrastructure monitoring and this paper presents summarised results from three distinct
monitoring projects carried out by this group. Firstly the findings from a project on next
generation Bridge Weight in Motion (B-WIM) are reported, this includes full scale field testing
using fibre optic strain sensors. Secondly, results from early phase testing of a computer
vision system for bridge deflection monitoring are reported on. This research seeks to exploit
recent advances in image processing technology with a view to developing contactless
bridge monitoring approaches. Considering the logistical difficulty of installing sensors on a
‘live’ bridge, contactless monitoring has some inherent advantages over conventional
contact based sensing systems. Finally the last section of the paper presents some recent
findings on drive by bridge monitoring. In practice a drive-by monitoring system will likely
require GPS to allow the response of a given bridge to be identified; this study looks at the
feasibility of using low-cost GPS sensors for this purpose, via field trials. The three topics
outlined above cover a spectrum of SHM approaches namely, wired monitoring, contactless
monitoring and drive by monitoring

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fibre-optic components and systems are used in a wide variety of industrial, medical and communication applications and can be found in use everywhere in the modern world, from the bottom of the ocean to satellites in orbit. The field of fibre optics has seen rapid growth in the past few decades to become an essential enabling technology. However, much more work is needed to develop components and systems that can work at wavelengths in the short-wavelength infrared (SWIR) / mid-IR part of the spectrum (defined in this work as 1.5 – 4.5.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

I shall discuss the quantum and classical dynamics of a class of nonlinear Hamiltonian systems. The discussion will be restricted to systems with one degree of freedom. Such systems cannot exhibit chaos, unless the Hamiltonians are time dependent. Thus we shall consider systems with a potential function that has a higher than quadratic dependence on the position and, furthermore, we shall allow the potential function to be a periodic function of time. This is the simplest class of Hamiltonian system that can exhibit chaotic dynamics. I shall show how such systems can be realized in atom optics, where very cord atoms interact with optical dipole potentials of a far-off resonance laser. Such systems are ideal for quantum chaos studies as (i) the energy of the atom is small and action scales are of the order of Planck's constant, (ii) the systems are almost perfectly isolated from the decohering effects of the environment and (iii) optical methods enable exquisite time dependent control of the mechanical potentials seen by the atoms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report quantum chaos phenomena in the atomic gravitational cavity. We consider the reflection of cold atoms from a temporally modulated evanescent wave. In the globally chaotic regime, for small modulation, the squared energy distribution as a function of time demonstrates dynamical localization. However, for larger modulation delocalization occurs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The microwave and thermal cure processes for the epoxy-amine systems (epoxy resin diglycidyl ether of bisphenol A, DGEBA) with 4,4'-diaminodiphenyl sulphone (DDS) and 4,4'-diaminodiphenyl methane (DDM) have been investigated for 1:1 stoichiometries by using fiber-optic FT-NIR spectroscopy. The DGEBA used was in the form of Ciba-Geigy GY260 resin. The DDM system was studied at a single cure temperature of 373 K and a single stoichiometry of 20.94 wt% and the DDS system was studied at a stoichiometry of 24.9 wt% and a range of temperatures between 393 and 443 K. The best values of the kinetic rate parameters for the consumption of amines have been determined by a least squares curve fit to a model for epoxy/amine cure. The activation energies for the polymerization of the DGEBA/DDS system were determined for both cure processes and found to be 66 and 69 kJ mol(-1) for the microwave and thermal cure processes, respectively. No evidence was found for any specific effect of the microwave radiation on the rate parameters, and the systems were both found to be characterized by a negative substitution effect. Copyright (C) 2002 John Wiley Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Male kids (110) from six goat genotypes, i.e. Boer x Angora (BA), Boer x Feral (1317), Boer x Saanen (BS), Feral x Feral (FF), Saanen x Angora (SA) and Saanen x Feral (SF) and two slaughter weight groups, i.e. Capretto and Chevon (liveweight at slaughter 14-22 and 30-35 kg, respectively) were compared for growth, carcass and meat quality characteristics. Due to their better growth rate, kids from BS and SF genotypes reached the required liveweight for slaughter earlier than kids from other Genotypes used in the study. Chevon kids had a significantly (P < 0.05) lower average daily gain (119 g per day) compared to Capretto kids (171 g per day). SA, SF and FF kids deposited more internal fat in comparison to kids from other genotypes. The dressing percentage of kids ranged from 51 to 54%, with significant differences between genotypes. BS and SF kids had longer carcasses. while BF kids had larger eye muscle area compared to other genotypes. Goat carcasses had a thin subcutaneous fat cover (1.6-2.2 mm). Genotype had a significant (P < 0.05) influence on cooking loss, pigment concentration and muscle colour parameters (CIE L*, a* and b* values). As denoted by the higher V and fibre optic probe values and lower subjective muscle score, the longissimus muscle colour was lighter for BS kids than other genotypes. Cooked meat from the BF kids had lower shear force values and better sensory scores compared to other genotypes. A significant (P < 0.05) decrease in muscle tenderness was observed from Capretto to Chevon carcasses, whereas cooked meat from these two slaughter weight groups was equally accepted (P > 0.05) by the panellists. (C) 2003 Elsevier Science B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A hyphenated instrumental approach has been used to obtain reliable values for the propagation rate coefficients as a function of conversion for polymerizations of methyl methacrylate (MMA) and a mixture of MMA and ethyleneglycol dimethacrylate (EGDMA) with a 1:1 concentration of double bonds, from near the onset of the Trommsdorf region into the glass region. ESR spectroscopy was used to measure the radical concentration while FT-NIR fibre-optic spectroscopy was employed to measure instantaneously the double-bond concentration within the temperature-controlled cavity of the ESR instrument during polymerization. The advantage of this approach to the measurement of the rate coefficient is that it is equally applicable to branching and linear polymerizations. For the polymerization of methyl methacrylate, the values of the rate coefficient at the lowest conversions at which reliable values could be obtained were in agreement with recently reported values obtained by the PLP-SEC method. For the lowest conversions, the values obtained were 403 1 mol(-1) s(-1) at 306 K for MMA and 5201 mol(-1) s(-1) at 310 K for a 1:1 mixture of MMA and EGDMA. (C) 2003 Society of Chemical Industry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The global dynamics of alliances are strongly determined by the level of cooperation among states. This cooperation can be embodied in various aspects, but the level of defense and security cooperation becomes usually more doctrinal and lasting. By the nature of sovereignty that instills in the bilateral relationship, cooperation at defense and security level can leverages other forms of cooperation. The circumstances and relational balance between Brazil and Portugal seem to evolve towards distancing opportunities, despite they are culturally and institutionally untainted. The economic dynamics, the strategic projection in global sustainability terms, the scale and ambition of Brazilian regional leadership, contrasts with the actual context of Portugal, distancing himself both on the stage where they operate. On the other hand, the historical and cultural roots, the language, the affinity of the peoples of CPLP and some opportunities for economic niches, trend to attract both countries. The condition of Portugal in NATO and Europe, coupled with the ability to export technical and human resources to value-added for Brazil, seems also to become approaching factors. On the balance of these dynamics, there is a set of exogenous factors (economic, external global relations matrix, regional stability, among others), which are not always controlled by any of both countries. These factors call for strong capacity for foresight analysis and decision making, with the inherent risk. There is cooperation vectors that are not apparently penalized by geographic distance, or by the difference of realities. Among these vectors we shall highlight synergies in technological niches, highly tradable goods and, mostly, using the domain of dual technologies. The thirteen niches herein identified are: Monitoring, Navigation, Command and Control, Electronics, Optoelectronics, Communication and remote sensing, Information Technologies, Flight Simulation, Specialized Training, Fiber Optic Sensors, Materials Engineering, Nanotechnology and Communications. Cumulating with identified opportunities in traditional relational framework, both countries are growing (in geography and economic terms) into the Atlantic, making it a central element in the bilateral approach. By being at the same time a growing stage of disputes and which stability tends to be threatened, it will be done an analysis of these synergistic vectors, superimposed on the impact on Atlantic securitization process.