728 resultados para Electrolytic corrosion


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This doctoral thesis describes the development work performed on the leachand purification sections in the electrolytic zinc plant in Kokkola to increase the efficiency in these two stages, and thus the competitiveness of the plant. Since metallic zinc is a typical bulk product, the improvement of the competitiveness of a plant was mostly an issue of decreasing unit costs. The problems in the leaching were low recovery of valuable metals from raw materials, and that the available technology offered complicated and expensive processes to overcome this problem. In the purification, the main problem was consumption of zinc powder - up to four to six times the stoichiometric demand. This reduced the capacity of the plant as this zinc is re-circulated through the electrolysis, which is the absolute bottleneck in a zinc plant. Low selectivity gave low-grade and low-value precipitates for further processing to metallic copper, cadmium, cobalt and nickel. Knowledge of the underlying chemistry was poor and process interruptions causing losses of zinc production were frequent. Studies on leaching comprised the kinetics of ferrite leaching and jarosite precipitation, as well as the stability of jarosite in acidic plant solutions. A breakthrough came with the finding that jarosite could precipitate under conditions where ferrite would leach satisfactorily. Based on this discovery, a one-step process for the treatment of ferrite was developed. In the plant, the new process almost doubled the recovery of zinc from ferrite in the same equipment as the two-step jarosite process was operated in at that time. In a later expansion of the plant, investment savings were substantial compared to other technologies available. In the solution purification, the key finding was that Co, Ni, and Cu formed specific arsenides in the “hot arsenic zinc dust” step. This was utilized for the development of a three-step purification stage based on fluidized bed technology in all three steps, i.e. removal of Cu, Co and Cd. Both precipitation rates and selectivity increased, which strongly decreased the zinc powder consumption through a substantially suppressed hydrogen gas evolution. Better selectivity improved the value of the precipitates: cadmium, which caused environmental problems in the copper smelter, was reduced from 1-3% reported normally down to 0.05 %, and a cobalt cake with 15 % Co was easily produced in laboratory experiments in the cobalt removal. The zinc powder consumption in the plant for a solution containing Cu, Co, Ni and Cd (1000, 25, 30 and 350 mg/l, respectively), was around 1.8 g/l; i.e. only 1.4 times the stoichiometric demand – or, about 60% saving in powder consumption. Two processes for direct leaching of the concentrate under atmospheric conditions were developed, one of which was implemented in the Kokkola zinc plant. Compared to the existing pressure leach technology, savings were obtained mostly in investment. The scientific basis for the most important processes and process improvements is given in the doctoral thesis. This includes mathematical modeling and thermodynamic evaluation of experimental results and hypotheses developed. Five of the processes developed in this research and development program were implemented in the plant and are still operated. Even though these processes were developed with the focus on the plant in Kokkola, they can also be implemented at low cost in most of the zinc plants globally, and have thus a great significance in the development of the electrolytic zinc process in general.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study determined the effect of an electrolytic lesion of the dorsal raphe nucleus (DRN) on water intake and sodium appetite. Male Wistar rats weighing 290-320 g with a lesion of the DRN (L-DRN), performed two days before experiments and confirmed by histology at the end of the experiments, presented increased sensitivity to the dehydration induced by fluid deprivation. The cumulative water intake of L-DRN rats reached 23.3 ± 1.9 ml (a 79% increase, N = 9) while sham-lesioned rats (SL-DRN) did not exceed 13.0 ± 1.0 ml (N = 11, P < 0.0001) after 5 h. The L-DRN rats treated with isoproterenol (300 µg kg-1 ml-1, sc) exhibited an increase in water intake that persisted throughout the experimental period (L-DRN, 15.7 ± 1.47 ml, N = 9 vs SL-DRN, 9.3 ± 1.8 ml, N = 11, P < 0.05). The L-DRN rats also showed an increased spontaneous sodium appetite during the entire period of assessment. The intake of 0.3 M NaCl after 12, 24, 36 and 72 h by the L-DRN rats was always higher than 20.2 ± 4.45 ml (N = 10), while the intake by SL-DRN was always lower than 2.45 ± 0.86 ml (N = 10, P < 0.00001). Sodium- and water-depleted L-DRN rats also exhibited an increased sodium appetite (13.9 ± 2.0 ml, N = 11) compared to SL-DRN (4.6 ± 0.64 ml, N = 11) after 120 min of observation (P < 0.02). The sodium preference of L-DRN rats in both conditions was always higher than that of SL-DRN rats. These results suggest that electrolytic lesion of the DRN overcomes a tonic inhibitory component of sodium appetite.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Head dipping (HD) is a behavioral pattern considered to have a risk assessment or an exploratory role and is used as a complementary parameter to evaluate anxiety in experimental animals. Since rats with electrolytic lesion in the area of the median raphe nucleus displayed high frequencies of HD in a previous study, the present investigation was undertaken to confirm this observation and to determine its anxiety-related origin. HD episodes were counted in adult male Wistar rats (270-350 g) with electrolytic lesion (N = 11) and sham-lesioned controls (N = 12). When HD was measured for 60 min on an elevated open platform, lesioned rats emitted 13 times more HD than controls (264.7 ± 93.3 vs 20.3 ± 7.6 episodes), with the difference being statistically significant (P < 0.05). HD counts during 10-min sessions held 7, 14, 21, 27, and 63 days after lesion showed significantly higher means (range: 28.14 ± 5.38 to 62.85 ± 9.48) compared to sham-lesioned controls (range: 7.37 ± 1.13 to 8.5 ± 1.45). Normal rats stepped down into their home cages when the vertical distance between them and the cage was short (16 cm), and the step-down latencies increased with increasing depths (36.7 ± 7.92 to 185.87 ± 35.44 s). Lesioned rats showed a similar behavior when facing the shortest depth, but had a significantly increased number (23.28 ± 2.35 episodes) and latency (300 ± 0.00 s) of HD compared to normal rats (9.25 ± 1.37 episodes and 185.87 ± 35.44 s) when facing the greatest depth (30 cm). This suggests that HD may be a depth-measuring behavior related to risk assessment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Preventive maintenance of frequency converters has been based on pre-planned replace-ment of wearing or ageing components. Exchange intervals follow component life-time expectations which are based on empirical knowledge or schedules defined by manufac-turer. However, the lifetime of a component can vary significantly, because drives are used in very different operating environments and applications. The main objective of the research was to provide information on methods, i.e. how in-verter's operating condition can be measured reliably under field conditions. At first, the research focused on critical components such as current transducers, IGBTs and DC link capacitor bank, because these aging have already been identified. Of these, the DC link capacitor measurement method was selected for closer examination. With this method, the total capacitance and its total series resistance can be measured. The suitability of the measuring procedure was estimated on the basis of practical measurements. The research was made by using so called triangulation method, including a literature review, simulations and practical measurements. Based on the results, the new measu-rement method seems suitable with some reservations to practical measurements. How-ever, the measuring method should be further developed in order to improve its reliability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectif : il a été rapporté que l’utilisation d’agents prophylactiques fluorés pouvait favoriser la corrosion galvanique au sein des alliages de titane. L’objectif de la présente étude était d’évaluer l’effet d’un rince-bouche fluoré sur les propriétés mécaniques de fils en nickel-titane (NiTi) et de fils en cuivre-nickel-titane (CuNiTi) lorsque ces derniers sont couplés à des boîtiers de compositions différentes (boîtiers de marques Smartclip, Clarity, et Sprint). Matériels et Méthodes : 90 segments de fils en NiTi et 90 segments de fils en CuNiTi ont été chacun couplés à 2 boîtiers de chaque marque. Chaque assemblage fil-boîtiers a été par la suite incubé pendant 3 heures à 37°C, soit dans une solution de fluore neutre (Fluorinse™ 0,05% NaF), soit dans une solution de salive artificielle (solution contrôle). Suite à l’incubation, les échantillons étaient nettoyés avec de l’eau déshydrogénée, les fils séparés des boîtiers et montés sur un support pour subir un test de pliage en trois points en milieu humide (salive artificielle) à 37°C. Les modules d’élasticité ainsi que les limites conventionnelles d’élasticité en activation et en désactivation ont été mesurés et comparés. Des analyses de Variance (ANOVA) et des comparaisons post-hoc avec la correction de Bonferronni ont été utilisées pour comparer les groupes entre eux (α = 0,05). Résultats : L’utilisation d’un rince-bouche fluoré a produit une réduction du module d’élasticité et de la limite conventionnelle d’élasticité en activation et en désactivation pour les fils en NiTi ; cependant, cet effet a été modulé par le type de boîtier auquel le fil a été couplé. Les propriétés mécaniques de fils en CuNiTi n’ont pas été affectées par le fluor, ou par le type de boîtier utilisé. Conclusions : L’utilisation d’un rince-bouche fluoré modifie les propriétés mécaniques des fils en NiTi seulement. Cet effet est modulé par le boîtier auquel le fil en NiTi est couplé. A la différence des autres études publiées dans la littérature, nos résultats ne nous permettent pas de conclure que la modification des propriétés mécaniques des fils en NiTi entrainerait obligatoirement un allongement de la durée du traitement orthodontique. Mots clés : Fluor, fils nickel-titane, boîtiers orthodontiques, corrosion galvanique, propriétés mécaniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

All the exciting work on developing new and better alloys has led older alloys, such as AZ9l , being abandoned by researchers. lt is believed that the full potential of AZ9l in automotive design has not been realized. Whatever works have been carried out on AZ9lalloy to improve its mechanical properties are insufficient in terms of its potential usage in auto industries. Due to the fact that AZ91 offers high room temperature mechanical properties and good castability, still this alloy is a primary choice for the auto component manufactures. Small improvement in its creep properties will have a huge impact in the transportation industries. Hence, in the present work, “Influence of Si, Sb and Sr Additions on the Microstructure, Mechanical Properties and Corrosion Behavior of AZ91 Magnesium Alloy”, an attempt has been made to improve the creep properties of AZ9l alloy through minor alloying elemental additions and to understand its strengthening mechanisms. The effect of alloying additions on the ageing and tensile properties of AZ9l is also studied. In addition to that, role of various intermetallics formed due to the alloying additions on the corrosion properties of AZ9l alloy is investigated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Corrosion characteristics of brass panels were investigated in the Vembanad estuarine water (Cochin Harbor), India over a period of one year. The corrosion rate of brass samples during exposure was determined by gravimetric method and fouling on panels was assessed, exposure-wise, in terms of biomass. Corrosion products were identified by X-Ray diffraction. The results of the study were discussed in the light of the seawater characteristics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Corrosion represents one of the largest through life cost component of ships. Ship owners and operators recognize that combating corrosion significantly impacts the vessels’ reliability, availability and through life costs. Primary objective of this paper is to review various inspections, monitoring systems and life cycle management with respect to corrosion control of ships and to develop the concept of “Corrosion Health” (CH) which would quantify the extent of corrosion at any point of ships’ operational life. A system approach in which the ship structure is considered as a corrosion system and divided into several corrosion zones, with distinct characteristics, is presented. Various corrosion assessment criteria for assessment of corrosion condition are listed. A CH rating system for representation of complex corrosion condition with a numeric number along with recommendations for repair/maintenance action is also discussed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

16S rRNA gene sequencing was used to identify a sulfate-reducing bacterium (SRB) from a Danish North Sea oilfield water injection system. This species was cultivated, purified and subsequently identified as being >97% similar to Desulfovibrio gracilis. Like some other Desulfovibrio species this SRB, strain OP102, could reduce nitrate as an electron acceptor and produce ammonia in the absence of sulfate. In addition, in the presence of sulfate, when nitrate was dosed at 100 mg/l it was again reduced by the bacterium, with some ammonium production. Therefore, this mechanism could be important in oilfield systems where nitrate is applied to prevent sulfide generation by SRB which leads to reservoir souring. In static tests the influence of this Desulfovibrio on corrosion was assessed using carbon steel coupons, in the presence of sulfate and in the presence of sulfate with 100 mg/l nitrate. Corrosion rates were less than 1.5 mpy when coupons were incubated in the same water, with sulfate and with nitrate. Furthermore, the occurrence of pitting corrosion was fairly low under all circumstances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Water soluble anionic and cationic bis-triazine ligands are able to suppress (mask) the extraction of corrosion and fission products such as Ni(II) and Pd(II) that are found in PUREX raffinates. Thus it is possible to separate these elements from the minor actinide Am(III). Although some masking agents have previously been developed that retard the extraction of Pd(II), this is the first time a masking agent has been developed for Ni(II).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The biocompatibility of commercially pure (cp) titanium stems from its chemical stability within an organism, due to a fine film of impermeable titanium oxide covering the metal surface, which guarantees its resistance to corrosion. Despite its biocompatible characteristic, this material does not promote the formation of a hydroxyapatite layer, therefore, many research groups have sought to alter the material`s surface, introducing modifications that might influence corrosion resistance. The electrochemical behavior of cp Ti, with hydroxyapatite coating and without hydroxyapatite coating, commonly used in implant materials, was investigated using an artificial saliva solution at 25 degrees C and pH=7.4. In the conditions of the study it was observed that the hydroxyapatite layer influences the properties of corrosion resistance. This study of the behavior of cp Ti with and without hydroxyapatite coating, in naturally aerated artificial saliva solution at 25 degrees C, was based on open circuit potential measurements and potentiodynamic polarization curves. At approximately 1x10(-6) A/cm(2) the potential for cp Ti with and without hydroxyapatite coating begins to increase at a faster rate, but at -74mV (SCE) for coated cp Ti and at 180mV (SCE) for uncoated cp Ti the increase in potential begins to slow. This behavior, characterized by a partial stabilization of current density, indicates that in those potential ranges a protective passive film is formed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The analysis of the electrical impedance of an electrolytic cell in the shape of a slab is performed. We have solved, numerically, the differential equations governing the phenomenon of the redistribution of the ions in the presence of an external electric field, and compared the results with the ones obtained by solving the linear approximation of these equations. The control parameters in our study are the amplitude and the frequency of the applied voltage, assumed a simple harmonic function of the time. We show that for the large amplitudes of the applied voltage, the actual current is no longer harmonic at low frequencies. From this result it follows that the concept of electrical impedance of a cell is a useful quantity only in the case where the linear approximation of the fundamental equations of problem work well.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyze the influence of a surface dielectric layer on the transient phenomena related to the ionic redistribution in an electrolytic cell submitted to a step-like external voltage. The adsorption-desorption phenomenon is taken into account in the famework of the Gouy-Chapman approximation, where the ions are assumed dimensionless. In the limit of small amplitude of the applied voltage, where the equations of the problem can be linearized, we obtain an analytical solution for the surface densities of ions, for the electrical potential and for the relaxation time for the transient phenomena. In the general case, when the linearized analysis is no longer valid, the solution of the problem is obtained numerically. The role of the thickness of the dielectric layer on the relaxation time is also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The corrosion resistance of Ti and Ti-6Al-4V was investigated through electrochemical impedance spectroscopy, EIS, potentiodynamic polarisation curves and UV-Vis spectrophotometry. The tests were done in Hank solution at 25 degrees C and 37 degrees C. The EIS measurements were done at the open circuit potential at specific immersion times. An increase of the resistance as a function of the immersion time was observed, for Ti (at 25 degrees C and 37 degrees C), and for Ti-6Al-4V (at 25 degrees C), which was interpreted as the formation and growth of a passive film on the metallic surfaces. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a study of AISI 1040 steel corrosion in aqueous electrolyte of acetic acid buffer containing 3.1 and 31 x 10(-3) mol dm(-3) of Na(2)S in both the presence and absence of 3.5 wt.% NaCl. This investigation of steel corrosion was carried out using potential polarization, and open-circuit and in situ optical microscopy. The morphological analysis and classification of types of surface corrosion damage by digital image processing reveals grain boundary corrosion and shows a non-uniform sulfide film growth, which occurs preferentially over pearlitic grains through successive formation and dissolution of the film. (C) 2011 Elsevier Ltd. All rights reserved.