930 resultados para Edge detectors


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The diffusion of mobile telephony began in 1971 in Finland, when the first car phones, called ARP1 were taken to use. Technologies changed from ARP to NMT and later to GSM. The main application of the technology, however, was voice transfer. The birth of the Internet created an open public data network and easy access to other types of computer-based services over networks. Telephones had been used as modems, but the development of the cellular technologies enabled automatic access from mobile phones to Internet. Also other wireless technologies, for instance Wireless LANs, were also introduced. Telephony had developed from analog to digital in fixed networks and allowed easy integration of fixed and mobile networks. This development opened a completely new functionality to computers and mobile phones. It also initiated the merger of the information technology (IT) and telecommunication (TC) industries. Despite the arising opportunity for firms' new competition the applications based on the new functionality were rare. Furthermore, technology development combined with innovation can be disruptive to industries. This research focuses on the new technology's impact on competition in the ICT industry through understanding the strategic needs and alternative futures of the industry's customers. The change speed inthe ICT industry is high and therefore it was valuable to integrate the DynamicCapability view of the firm in this research. Dynamic capabilities are an application of the Resource-Based View (RBV) of the firm. As is stated in the literature, strategic positioning complements RBV. This theoretical framework leads theresearch to focus on three areas: customer strategic innovation and business model development, external future analysis, and process development combining these two. The theoretical contribution of the research is in the development of methodology integrating theories of the RBV, dynamic capabilities and strategic positioning. The research approach has been constructive due to the actual managerial problems initiating the study. The requirement for iterative and innovative progress in the research supported the chosen research approach. The study applies known methods in product development, for instance, innovation process in theGroup Decision Support Systems (GDSS) laboratory and Quality Function Deployment (QFD), and combines them with known strategy analysis tools like industry analysis and scenario method. As the main result, the thesis presents the strategic innovation process, where new business concepts are used to describe the alternative resource configurations and scenarios as alternative competitive environments, which can be a new way for firms to achieve competitive advantage in high-velocity markets. In addition to the strategic innovation process as a result, thestudy has also resulted in approximately 250 new innovations for the participating firms, reduced technology uncertainty and helped strategic infrastructural decisions in the firms, and produced a knowledge-bank including data from 43 ICT and 19 paper industry firms between the years 1999 - 2004. The methods presentedin this research are also applicable to other industries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Position sensitive particle detectors are needed in high energy physics research. This thesis describes the development of fabrication processes and characterization techniques of silicon microstrip detectors used in the work for searching elementary particles in the European center for nuclear research, CERN. The detectors give an electrical signal along the particles trajectory after a collision in the particle accelerator. The trajectories give information about the nature of the particle in the struggle to reveal the structure of the matter and the universe. Detectors made of semiconductors have a better position resolution than conventional wire chamber detectors. Silicon semiconductor is overwhelmingly used as a detector material because of its cheapness and standard usage in integrated circuit industry. After a short spread sheet analysis of the basic building block of radiation detectors, the pn junction, the operation of a silicon radiation detector is discussed in general. The microstrip detector is then introduced and the detailed structure of a double-sided ac-coupled strip detector revealed. The fabrication aspects of strip detectors are discussedstarting from the process development and general principles ending up to the description of the double-sided ac-coupled strip detector process. Recombination and generation lifetime measurements in radiation detectors are discussed shortly. The results of electrical tests, ie. measuring the leakage currents and bias resistors, are displayed. The beam test setups and the results, the signal to noise ratio and the position accuracy, are then described. It was found out in earlier research that a heavy irradiation changes the properties of radiation detectors dramatically. A scanning electron microscope method was developed to measure the electric potential and field inside irradiated detectorsto see how a high radiation fluence changes them. The method and the most important results are discussed shortly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, edge matching puzzles, an NP-complete problem, have rececived, thanks to money-prized contests, considerable attention from wide audiences. We consider these competitions not only a challenge for SAT/CSP solving techniques but also as an opportunity to showcase the advances in the SAT/CSP community to a general audience. This paper studies the NP-complete problem of edge matching puzzles focusing on providing generation models of problem instances of variable hardness and on its resolution through the application of SAT and CSP techniques. From the generation side, we also identify the phase transition phenomena for each model. As solving methods, we employ both; SAT solvers through the translation to a SAT formula, and two ad-hoc CSP solvers we have developed, with different levels of consistency, employing several generic and specialized heuristics. Finally, we conducted an extensive experimental investigation to identify the hardest generation models and the best performing solving techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis describes the development of advanced silicon radiation detectors and their characterization by simulations, used in the work for searching elementary particles in the European Organization for Nuclear Research, CERN. Silicon particle detectors will face extremely harsh radiation in the proposed upgrade of the Large Hadron Collider, the future high-energy physics experiment Super-LHC. The increase in the maximal fluence and the beam luminosity up to 1016 neq / cm2 and 1035 cm-2s-1 will require detectors with a dramatic improvement in radiation hardness, when such a fluence will be far beyond the operational limits of the present silicon detectors. The main goals of detector development concentrate on minimizing the radiation degradation. This study contributes mainly to the device engineering technology for developing more radiation hard particle detectors with better characteristics. Also the defect engineering technology is discussed. In the nearest region of the beam in Super-LHC, the only detector choice is 3D detectors, or alternatively replacing other types of detectors every two years. The interest in the 3D silicon detectors is continuously growing because of their many advantages as compared to conventional planar detectors: the devices can be fully depleted at low bias voltages, the speed of the charge collection is high, and the collection distances are about one order of magnitude less than those of planar technology strip and pixel detectors with electrodes limited to the detector surface. Also the 3D detectors exhibit high radiation tolerance, and thus the ability of the silicon detectors to operate after irradiation is increased. Two parameters, full depletion voltage and electric field distribution, is discussed in more detail in this study. The full depletion of the detector is important because the only depleted area in the detector is active for the particle tracking. Similarly, the high electric field in the detector makes the detector volume sensitive, while low-field areas are non-sensitive to particles. This study shows the simulation results of full depletion voltage and the electric field distribution for the various types of 3D detectors. First, the 3D detector with the n-type substrate and partial-penetrating p-type electrodes are researched. A detector of this type has a low electric field on the pixel side and it suffers from type inversion. Next, the substrate is changed to p-type and the detectors having electrodes with one doping type and the dual doping type are examined. The electric field profile in a dual-column 3D Si detector is more uniform than that in the single-type column 3D detector. The dual-column detectors are the best in radiation hardness because of their low depletion voltages and short drift distances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tämän diplomityön tavoitteena oli löytää prosessiparametrejä nestepakkauskartongin reuna-alueiden kuivatuskutistuman hallintaan ja saada tuotteen reuna-alueiden sileystaso paremmaksi. Tarkoituksena oli parantaa reuna-alueiden painettavuusominaisuuksia sekä saada koneen poikkisuunnassa laadultaan parempi tuote. Työn kirjallisuusosassa on tarkasteltu työn kannalta nestepakkauskartongin kriittisimpiä ominaisuuksia, sileyttä ja jäykkyyttä. Lisäksi kirjallisuusosassa on tarkasteltu kuitujen ominaisuuksia, sylinterikuivatusta ja kuivatuskutistumaa. Kokeellisessa osassa on etsitty esitutkimuksella prosessiparametrejä, jotka ovat aiheuttaneet poikkisuunnan sileyserojen kasvun kartonkikoneen investoinnin jälkeen. Suoria korrelaatioita prosessiparametrien ja kuivatuskutistuman välille ei löydetty. Kokeellisen osan tehdasmittakaavaisissa koeajoissa tutkittiin kahdeksan eri parametrin vaikutusta kuivatuskutistumaan, jotka perustuivat kirjallisuuteen. Tutkituista parametreistä huulisuihkun iskukulman muutoksella sekä konesuuntaisella kuivatusprofiililla ei ollut vaikutusta kuivatuskutistumaan. Runkokerroksen mäntysellun korvaaminen koivusellulla vähensi kuivatuskutistumaa ja lisäsi sileyttä, mutta tuotteen palstautumislujuus ei tällöin ollut riittävä. Retentiokemikaalien reseptimuutoksilla pinta- ja taustakerroksen välillä, kuivatusosan nollatason laskulla ja perälaatikkosakeuksien pienentämisellä oli vähän vaikutusta kuivatuskutistumaan. Vaikutus reuna-alueiden sileyteen oli kuitenkin vähemmän kuin 10 %. Diplomityön perusteella kuivatusosan nopeuseroilla ja kuivatusviirojen kireyksillä oli suurin vaikutusta kuivatuskutistumaan ja reuna-alueiden sileystasoon. Lisäämällä nopeuseroja ja kiristämällä kuivatusviiroja reuna-alueiden sileyttä pystyttiin parantamaan yli 20 %.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statistical properties of binary complex networks are well understood and recently many attempts have been made to extend this knowledge to weighted ones. There are, however, subtle yet important considerations to be made regarding the nature of the weights used in this generalization. Weights can be either continuous or discrete magnitudes, and in the latter case, they can additionally have undistinguishable or distinguishable nature. This fact has not been addressed in the literature insofar and has deep implications on the network statistics. In this work we face this problem introducing multiedge networks as graphs where multiple (distinguishable) connections between nodes are considered. We develop a statistical mechanics framework where it is possible to get information about the most relevant observables given a large spectrum of linear and nonlinear constraints including those depending both on the number of multiedges per link and their binary projection. The latter case is particularly interesting as we show that binary projections can be understood from multiedge processes. The implications of these results are important as many real-agent-based problems mapped onto graphs require this treatment for a proper characterization of their collective behavior.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The silicon photomultiplier (SiPM) is a novel detector technology that has undergone a fast development in the last few years, owing to its single-photon resolution and ultra-fast response time. However, the typical high dark count rates of the sensor may prevent the detection of low intensity radiation fluxes. In this article, the time-gated operation with short active periods in the nanosecond range is proposed as a solution to reduce the number of cells fired due to noise and thus increase the dynamic range. The technique is aimed at application fields that function under a trigger command, such as gated fluorescence lifetime imaging microscopy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The semiconductor particle detectors used at CERN experiments are exposed to radiation. Under radiation, the formation of lattice defects is unavoidable. The defects affect the depletion voltage and leakage current of the detectors, and hence affect on the signal-to-noise ratio of the detectors. This shortens the operational lifetime of the detectors. For this reason, the understanding of the formation and the effects of radiation induced defects is crucial for the development of radiation hard detectors. In this work, I have studied the effects of radiation induced defects-mostly vacancy related defects-with a simulation package, Silvaco. Thus, this work essentially concerns the effects of radiation induced defects, and native defects, on leakage currents in particle detectors. Impurity donor atom-vacancy complexes have been proved to cause insignificant increase of leakage current compared with the trivacancy and divacancy-oxygen centres. Native defects and divacancies have proven to cause some of the leakage current, which is relatively small compared with trivacancy and divacancy-oxygen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We quickly form first impressions about newly encountered people guiding our subsequent behaviour (approach, avoidance). Such instant judgments might be innate and automatic, being performed unconsciously and independently to other cognitive processes. Lying detection might be subject to such a modular process. Unfortunately, numerous studies highlighted problems with lying detection paradigms such as high error rates and learning effects. Additionally, humans should be motivated doing both detecting others' lies and dis- guising own lies. Disguising own lies might even be more challenging than detecting other people's lies. Thus, when trying to disguise cheating behaviour, liars might display a mixture of disguising (fake) trust cues and uncontrolled lying cues making the interpretation of the expression difficult (perceivers are guessing). In two consecutive online studies, we tested whether seeing an increasing amount (range 0-4) of lying cues (LC) and non-lying cues (NLC) on a standard face results in enhanced guessing behaviour (studies 1 and 2) and that enhanced guessing is accompanied by slower responding (study 2). Results showed that pronounced guessing and slowest responding occurred for faces with an intermediate number and not with the highest number of LC and NLC. In particular, LC were more impor- tant than NLC to uncertain lying decisions. Thus, only a few LC may interfere with automatic processing of lying detection (irrespective of NLC), probably because too little lying cue information is yet available.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

NlmCategory="UNASSIGNED">A version of cascaded systems analysis was developed specifically with the aim of studying quantum noise propagation in x-ray detectors. Signal and quantum noise propagation was then modelled in four types of x-ray detectors used for digital mammography: four flat panel systems, one computed radiography and one slot-scan silicon wafer based photon counting device. As required inputs to the model, the two dimensional (2D) modulation transfer function (MTF), noise power spectra (NPS) and detective quantum efficiency (DQE) were measured for six mammography systems that utilized these different detectors. A new method to reconstruct anisotropic 2D presampling MTF matrices from 1D radial MTFs measured along different angular directions across the detector is described; an image of a sharp, circular disc was used for this purpose. The effective pixel fill factor for the FP systems was determined from the axial 1D presampling MTFs measured with a square sharp edge along the two orthogonal directions of the pixel lattice. Expectation MTFs were then calculated by averaging the radial MTFs over all possible phases and the 2D EMTF formed with the same reconstruction technique used for the 2D presampling MTF. The quantum NPS was then established by noise decomposition from homogenous images acquired as a function of detector air kerma. This was further decomposed into the correlated and uncorrelated quantum components by fitting the radially averaged quantum NPS with the radially averaged EMTF(2). This whole procedure allowed a detailed analysis of the influence of aliasing, signal and noise decorrelation, x-ray capture efficiency and global secondary gain on NPS and detector DQE. The influence of noise statistics, pixel fill factor and additional electronic and fixed pattern noises on the DQE was also studied. The 2D cascaded model and decompositions performed on the acquired images also enlightened the observed quantum NPS and DQE anisotropy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Large Hadron Collider (LHC) is the main particle accelerator at CERN. LHC is created with main goal to search elementary particles and help science investigate our universe. Radiation in LHC is caused by charged particles circular acceleration, therefore detectors tracing particles in existed severe conditions during the experiments must be radiation tolerant. Moreover, further upgrade of luminosity (up to 1035 cm-2s-1) requires development of particle detector’s structure. This work is dedicated to show the new type 3D stripixel detector with serious structural improvement. The new type of radiation-hard detector has a three-dimensional (3D) array of the p+ and n+ electrodes that penetrate into the detector bulk. The electrons and holes are then collected at oppositely biased electrodes. Proposed 3D stripixel detector demonstrates that full depletion voltage is lower that that for planar detectors. Low depletion voltage is one of the main advantages because only depleted part of the device is active are. Because of small spacing between electrodes, charge collection distances are smaller which results in high speed of the detector’s response. In this work is also briefly discussed dual-column type detectors, meaning consisting both n+ and p+ type columnar electrodes in its structure, and was declared that dual-column detectors show better electric filed distribution then single sided radiation detectors. The dead space or in other words low electric field region in significantly suppressed. Simulations were carried out by using Atlas device simulation software. As a simulation results in this work are represented the electric field distribution under different bias voltages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Efficient problem solving in cellular networks is important when enhancing the network performance and liability. Analysis of calls and packet switched sessions in protocol level between the network elements is an important part of this process. They can provide very detailed information about error situations which otherwise would be difficult to recognise. In this thesis we seek solutions for monitoring GPRS/EDGE sessions in two specific interfaces simultaneously in such manner that all information important to the users will be provided in easily understandable form. This thesis focuses on Abis and AGPRS interfaces of GSM radio network and introduces a solution for managing the correlation between these interfaces by using signalling messages and common parameters as linking elements. ~: Finally this thesis presents an implementation of GPRS/EDGE session monitoring application for Abis and AGPRS interfaces and evaluates its benefits to the end users. Application is implemented as a part of Windows based 3G/GSM network analyser.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The high sensitivity and excellent timing accuracy of Geiger mode avalanche photodiodes makes them ideal sensors as pixel detectors for particle tracking in high energy physics experiments to be performed in future linear colliders. Nevertheless, it is well known that these sensors suffer from dark counts and afterpulsing noise, which induce false hits (indistinguishable from event detection) as well as an increase of the necessary area of the readout system. In this work, we present a comparison between APDs fabricated in a high voltage 0.35 µm and a high integration 0.13 µm commercially available CMOS technologies that has been performed to determine which of them best fits the particle collider requirements. In addition, a readout circuit that allows low noise operation is introduced. Experimental characterization of the proposed pixel is also presented in this work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The quantitative structure property relationship (QSPR) for the boiling point (Tb) of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) was investigated. The molecular distance-edge vector (MDEV) index was used as the structural descriptor. The quantitative relationship between the MDEV index and Tb was modeled by using multivariate linear regression (MLR) and artificial neural network (ANN), respectively. Leave-one-out cross validation and external validation were carried out to assess the prediction performance of the models developed. For the MLR method, the prediction root mean square relative error (RMSRE) of leave-one-out cross validation and external validation was 1.77 and 1.23, respectively. For the ANN method, the prediction RMSRE of leave-one-out cross validation and external validation was 1.65 and 1.16, respectively. A quantitative relationship between the MDEV index and Tb of PCDD/Fs was demonstrated. Both MLR and ANN are practicable for modeling this relationship. The MLR model and ANN model developed can be used to predict the Tb of PCDD/Fs. Thus, the Tb of each PCDD/F was predicted by the developed models.