947 resultados para Echocardiography, Doppler, Color


Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: To assess the cardiovascular features of Ullrich-Turner's syndrome using echocardiography and magnetic resonance imaging, and to correlate them with the phenotype and karyotype of the patients. The diagnostic concordance between the 2 methods was also assessed. METHODS: Fifteen patients with the syndrome were assessed by echocardiography and magnetic resonance imaging (cardiac chambers, valves, and aorta). Their ages ranged from 10 to 28 (mean of 16.7) years. The karyotype was analyzed in 11 or 25 metaphases of peripheral blood lymphocytes, or both. RESULTS: The most common phenotypic changes were short stature and spontaneous absence of puberal development (100%); 1 patient had a cardiac murmur. The karyotypes detected were as follows: 45,X (n=7), mosaics (n=5), and deletions (n=3). No echocardiographic changes were observed. In regard to magnetic resonance imaging, coarctation and dilation of the aorta were found in 1 patient, and isolated dilation of the aorta was found in 4 patients. CONCLUSION: The frequencies of coarctation and dilation of the aorta detected on magnetic resonance imaging were similar to those reported in the literature (5.5% to 20%, and 6.3% to 29%, respectively). This confirmed the adjuvant role of magnetic resonance imaging to Doppler echocardiography for diagnosing cardiovascular alterations in patients with Ullrich-Turner's syndrome.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Pós-graduação em Ginecologia, Obstetrícia e Mastologia - FMB

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Abstract Background Hand-carried ultrasound (HCU) devices have been demonstrated to improve the diagnosis of cardiac diseases over physical examination, and have the potential to broaden the versatility in ultrasound application. The role of these devices in the assessment of hospitalized patients is not completely established. In this study we sought to perform a direct comparison between bedside evaluation using HCU and comprehensive echocardiography (CE), in cardiology inpatient setting. Methods We studied 44 consecutive patients (mean age 54 ± 18 years, 25 men) who underwent bedside echocardiography using HCU and CE. HCU was performed by a cardiologist with level-2 training in the performance and interpretation of echocardiography, using two-dimensional imaging, color Doppler, and simple calliper measurements. CE was performed by an experienced echocardiographer (level-3 training) and considered as the gold standard. Results There were no significant differences in cardiac chamber dimensions and left ventricular ejection fraction determined by the two techniques. The agreement between HCU and CE for the detection of segmental wall motion abnormalities was 83% (Kappa = 0.58). There was good agreement for detecting significant mitral valve regurgitation (Kappa = 0.85), aortic regurgitation (kappa = 0.89), and tricuspid regurgitation (Kappa = 0.74). A complete evaluation of patients with stenotic and prosthetic dysfunctional valves, as well as pulmonary hypertension, was not possible using HCU due to its technical limitations in determining hemodynamic parameters. Conclusion Bedside evaluation using HCU is helpful for assessing cardiac chamber dimensions, left ventricular global and segmental function, and significant valvular regurgitation. However, it has limitations regarding hemodynamic assessment, an important issue in the cardiology inpatient setting.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduzione: Negli ultimi anni, il color-power Doppler si è dimostrato un utile strumento per valutare le alterazioni della vascolarizzazione della parete intestinale nelle patologie del tratto gastro-enterico. Più di recente, i mezzi di contrasto ecografici di II generazione associati all’ecografia real-time con basso indice meccanico (CEUS) hanno permesso di valutare ecograficamente il microcircolo, consentendo la valutazione della vascolarizzazione di parete nelle patologie associate a flogosi e neoangiogenesi. Studi recenti hanno documentato i pattern Doppler e CEUS nella malattia infiammatoria intestinale. Le alterazioni della vascolarizzazione di parete nella patologia neoplastica, invece, sono state finora valutate con sola tecnica Doppler. Recenti studi basati sull’impiego di tale metodica hanno in effetti dimostrato che l’intensità del segnale vascolare di parete correla con la variante istologica della neoplasia e con il suo grado di invasione vascolare costituendo così un parametro di neoangiogenesi tumorale. Pertanto, ottenere mediante CEUS una più accurata definizione del microcircolo di parete potrebbe aiutare nella diagnosi differenziale tra patologia infiammatoria e neoplastica dello stomaco e fornire utili informazioni per valutare l’ aggressività del cancro gastrico.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background. Abdominal porto-systemic collaterals (APSC) on Color-Doppler ultrasound are a frequent finding in portal hypertensive cirrhotic patients. In patients with cirrhosis, an HVPG ≥ 16mmHg has been shown to be associated with increased mortality in two studies. Non-invasive indicators of HVPG ≥ 16 mmHg might define a subgroup of high-risk patients, but data on this aspect are lacking. Aims. We aimed to investigate whether HVPG predicts mortality in patients with clinically significant portal hypertension, and if APSC may predict a severe portal hypertensive state (i.e. HVPG≥16mmHg) in patients with cirrhosis and untreated portal hypertension. Methods. We analysed paired HVPG and ultrasonographic data of 86 untreated portal hypertensive cirrhotic patients. On abdominal echo-color-Doppler data on presence, type and number of APSC were prospectively collected. HVPG was measured following published guidelines. Clinical, laboratory and endoscopic data were available in all cases. First decompensation of cirrhosis and liver-disease related mortality on follow-up (mean 28±20 months) were recorded. Results. 73% of patients had compensated cirrhosis, while 27% were decompensated. All patients had an HVPG≥10 mmHg (mean 17.8±5.1 mmHg). 58% of compensated patients and 82% of decompensated patients had an HVPG over 16 mmHg. 25% had no varices, 28% had small varices, and 47% had medium/large varices. HVPG was higher in patients with esophageal varices vs. patients without varices (19.0±4.8 vs. 14.1±4.2mmHg, p<0.0001), and correlated with Child-Pugh score (R=0.494,p=0.019). 36 (42%) patients had APSC were more frequent in decompensated patients (60% vs. 35%, p=0.03) and in patients with esophageal varices (52% vs. 9%,p=0.001). HVPG was higher in patients with APSC compared with those without PSC (19.9± 4.6 vs. 16.2± 4.9mmHg, p=0.001). The prevalence of APSC was higher in patients with HVPG≥16mmHg vs. those with HVPG<16mmHg (57% vs. 13%,p<0.0001). Decompensation was significantly more frequent in patients with HVPG≥16mmHg vs. HVPG<16mmHg (35.1% vs. 11.5%, p=0.02). On multivariate analysis only HVPG and bilirubin were independent predictors of first decompensation. 10 patients died during follow-up. All had an HVPG≥16 mmHg (26% vs. 0% in patients with HVPG <16mmHg,p=0.04). On multivariate analysis only MELD score and HVPG ≥16mmHg were independent predictors of mortality. In compensated patients the detection of APSC predicted an HVPG≥16mmHg with 92% specificity, 54% sensitivity, positive and negative likelihood ratio 7.03 and 0.50, which implies that the demonstration of APSC on ultrasound increased the probability of HVPG≥16mmHg from 58% to 91%. Conclusions. HVPG maintains an independent prognostic value in the subset of patients with cirrhosis and clinically significant portal hypertension. The presence of APSC is a specific indicator of severe portal hypertension in patients with cirrhosis. Detection of APSC on ultrasound allows the non-invasive identification of a subgroup of compensated patients with bad prognosis, avoiding the invasive measurement of HVPG.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Rhythm analysis of the fetal heart is hampered by the inability to routinely obtain electrocardiographic recordings of the fetus. Doppler studies of fetal cardiac tissue movements, assessing cardiac movements both qualitatively and quantitatively, have recently been described. We used a conventional high-resolution ultrasound system to obtain rhythm data from pulsed-wave tissue Doppler signals of the fetal heart in normal cardiac rhythm and in a variety of fetal cardiac arrhythmias.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: False-negative interpretations of do-butamine stress echocardiography (DSE) may be associated with reduced wall stress. using measurements of contraction, we sought whether these segments were actually ischemic but unrecognized or showed normal contraction. Methods. We studied 48 patients (29 men; mean age 60 +/- 10 years) with normal regional function on the basis of standard qualitative interpretation of DSE. At coronary angiography within. 6 months of DSE, 32 were identified as having true-negative and 16 as having false-negative results of DSE. Three apical views were used to measure regional function with color Doppler tissue, integrated backscatter, and strain rate imaging. Cyclic variation of integrated backscatter was measured in 16 segments, and strain rate and peak systolic strain was calculated in 6 walls at rest and peak stress. Results. Segments with false-negative results of DSE were divided into 2 groups with and without low wall stress according to previously published cut-off values. Age, sex, left ventricular mass, left ventricular geometric pattern, and peak workload were not significantly different between patients with true and false-negative results of DSE. Importantly, no significant differences in cyclic variation and strain parameters at rest and peak stress were found among segments with true-and false-negative results of DSE with and without low wall stress. Stenosis severity had no influence on cyclic variation and strain parameters at peak stress. Conclusions: False-negative results of DSE reflect lack of ischemia rather than underinterpretation of regional left ventricular function. Quantitative markers are unlikely to increase the sensitivity of DSE.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Tissue Doppler (TD) assessment of dysynchrony (DYS) is established in evaluation for bi-ventricular pacing. Time to regional minimal volume by real-time 3D echo (3D) has been applied to DYS. 3D offers simultaneous assessment of all segments and may limit errors in localization of maximum delay due to off-axis images.We compared TD and 3D for assessment of DYS. 27 patients with ischaemic cardiomyopathy (aged 60±11 years, 85% male) underwent TD with generation of regional velocity curves. The interval between QRS onset and maximal systolic velocity (TTV) was measured in 6 basal and 6 mid-cavity segments. Onthe same day,3Dwas performed and data analysed offline with Q-Lab software (Philips, Andover, MA). Using 12 analogous regional time-volume curves time to minimal volume (T3D)was calculated. The standard deviation (S.D.) between segments in TTV and T3D was calculated as a measure ofDYS. In 7 patients itwas not possible to measureT3D due to poor images. In the remaining 20, LV diastolic volume, systolic volume and EF were 128±35 ml, 68±23 ml and 46±13%, respectively. Mean TTV was less than mean T3D (150±33ms versus 348±54 ms; p < 0.01). The intrapatient range was 20–210ms for TTV and 0–410ms for T3D. Of 9 patients (45%) with significantDYS (S.D. TTV > 32 ms), S.D. T3D was 69±37ms compared to 48±34ms in those without DYS (p = ns). In DYS patients there was concordance of the most delayed segment in 4 (44%) cases.Therefore, different techniques for assessing DYS are not directly comparable. Specific cut-offs for DYS are needed for each technique.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study aimed to evaluate the Color Doppler ultrasound as a substitute for laparoscopy for couting of corpora lutea (CL) in superovulated sheep. In conclusion, the Color Doppler ultrasonography is highly efficient to estimate the number of CLs in superovulated ewes. This represents an important advance because it replaces invasive laparoscopic procedure, avoids fasting, drugs use and unnecessary handling in animals that did not respond to the treatment. Therefore, the Color Doppler ultrasound can replace the laparoscopy for the assessment of superovulated sheep.