521 resultados para ERS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Yeast Sec22p participates in both anterograde and retrograde vesicular transport between the endoplasmic reticulum (ER) and the Golgi apparatus by functioning as a v-SNARE (soluble N-ethylmaleimide-sensitive factor [NSF] attachment protein receptor) of transport vesicles. Three mammalian proteins homologous to Sec22p have been identified and are referred to as Sec22a, Sec22b/ERS-24, and Sec22c, respectively. The existence of three homologous proteins in mammalian cells calls for detailed cell biological and functional examinations of each individual protein. The epitope-tagged forms of all three proteins have been shown to be primarily associated with the ER, although functional examination has not been carefully performed for any one of them. In this study, using antibodies specific for Sec22b/ERS-24, it is revealed that endogenous Sec22b/ERS-24 is associated with vesicular structures in both the perinuclear Golgi and peripheral regions. Colabeling experiments for Sec22b/ERS-24 with Golgi mannosidase II, the KDEL receptor, and the envelope glycoprotein G (VSVG) of vesicular stomatitis virus (VSV) en route from the ER to the Golgi under normal, brefeldin A, or nocodazole-treated cells suggest that Sec22b/ERS-24 is enriched in the pre-Golgi intermediate compartment (IC). In a well-established semi-intact cell system that reconstitutes transport from the ER to the Golgi, transport of VSVG is inhibited by antibodies against Sec22b/ERS-24. EGTA is known to inhibit ER–Golgi transport at a stage after vesicle/transport intermediate docking but before the actual fusion event. Antibodies against Sec22b/ERS-24 inhibit ER–Golgi transport only when they are added before the EGTA-sensitive stage. Transport of VSVG accumulated in pre-Golgi IC by incubation at 15°C is also inhibited by Sec22b/ERS-24 antibodies. Morphologically, VSVG is transported from the ER to the Golgi apparatus via vesicular intermediates that scatter in the peripheral as well as the Golgi regions. In the presence of antibodies against Sec22b/ERS-24, VSVG is seen to accumulate in these intermediates, suggesting that Sec22b/ERS-24 functions at the level of the IC in ER–Golgi transport.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Title from caption.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, we introduced a new 'GLM-beamformer' technique for MEG analysis that enables accurate localisation of both phase-locked and non-phase-locked neuromagnetic effects, and their representation as statistical parametric maps (SPMs). This provides a useful framework for comparison of the full range of MEG responses with fMRI BOLD results. This paper reports a 'proof of principle' study using a simple visual paradigm (static checkerboard). The five subjects each underwent both MEG and fMRI paradigms. We demonstrate, for the first time, the presence of a sustained (DC) field in the visual cortex, and its co-localisation with the visual BOLD response. The GLM-beamformer analysis method is also used to investigate the main non-phase-locked oscillatory effects: an event-related desynchronisation (ERD) in the alpha band (8-13 Hz) and an event-related synchronisation (ERS) in the gamma band (55-70 Hz). We show, using SPMs and virtual electrode traces, the spatio-temporal covariance of these effects with the visual BOLD response. Comparisons between MEG and fMRI data sets generally focus on the relationship between the BOLD response and the transient evoked response. Here, we show that the stationary field and changes in oscillatory power are also important contributors to the BOLD response, and should be included in future studies on the relationship between neuronal activation and the haemodynamic response. © 2005 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The satellite ERS-1 was launched in July 1991 in a period of high solar activity. Sparse laser tracking and the failure of the experimental microwave system (PRARE) compounded the orbital errors which resulted from mismodelling of atmospheric density and hence surface forces. Three attempts are presented here to try and refine the coarse laser orbits of ERS-1, made prior to the availability of the full altimetric dataset. The results of the first attempt indicate that by geometrically modelling the satellite shape some improvement in orbital precision may be made for any satellite; especially one where no area tables already exist. The second and third refinement attempts are based on the introduction of data from some second satellite; in these examples SPOT-2 and TOPEX/Poseidon are employed. With SPOT-2 the method makes use of the orbital similarities to produce along-track corrections for the more fully tracked SPOT-2. Transferring these corrections to ERS-1 produces improvements in the precise orbits thus determined. With TOPEX/Poseidon the greater altitude results in a more precise orbit (gravity field and atmospheric errors are of less importance). Thus, by computing height differences at crossover points of the TOPEX/Poseidon and ERS-1 ground tracks the poorer orbit of ERS-1 may be improved by the addition of derived radial corrections. In the positive light of all three results several potential modification are suggested and some further avenues of investigation indicated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In previous sea-surface variability studies, researchers have failed to utilise the full ERS-1 mission due to the varying orbital characteristics in each mission phase, and most have simply ignored the Ice and Geodetic phases. This project aims to introduce a technique which will allow the straightforward use of all orbital phases, regardless of orbit type. This technique is based upon single satellite crossovers. Unfortunately the ERS-1 orbital height is still poorly resolved (due to higher air drag and stronger gravitational effects) when compared with that of TOPEX/Poseidon (T/P), so to make best use of the ERS-1 crossover data corrections to the ERS-1 orbital heights are calculated by fitting a cubic-spline to dual-crossover residuals with T/P. This correction is validated by comparison of dual satellite crossovers with tide gauge data. The crossover processing technique is validated by comparing the extracted sea-surface variability information with that from T/P repeat pass data. The two data sets are then combined into a single consistent data set for analysis of sea-surface variability patterns. These patterns are simplified by the use of an empirical orthogonal function decomposition which breaks the signals into spatial modes which are then discussed separately. Further studies carried out on these data include an analysis of the characteristics of the annual signal, discussion of evidence for Rossby wave propagation on a global basis, and finally analysis of the evidence for global mean sea level rise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The work described in this thesis concerns the application of radar altimetry, collected from the ERS-1 and TOPEX/POSEIDON missions, to precise satellite orbits computed at Aston University. The data is analysed in a long arc fashion to determine range biases, time tag biases, sea surface topographies and to assess the radial accuracy of the generated orbits through crossover analysis. A sea surface variability study is carried out for the North Sea using repeat altimeter profiles from ERS-1 and TOPEX/POSEIDON in order to verify two local U.K. models for ocean tide and storm surge effects. An on-side technique over the English Channel is performed to compute the ERS-1, TOPEX and POSEIDON altimeter range biases by using a combination of altimetry, precise orbits determined by short arc methods, tide gauge data, GPS measurements, geoid, ocean tide and storm surge models. The remaining part of the thesis presents some techniques for the short arc correction of long arc orbits. Validation of this model is achieved by way of comparison with actual SEASAT short arcs. Simulations are performed for the ERS-1 microwave tracking system, PRARE, using the range data to determine time dependent orbit corrections. Finally, a brief chapter is devoted to the recovery of errors in station coordinates by the use of multiple short arcs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to the failure of PRARE the orbital accuracy of ERS-1 is typically 10-15 cm radially as compared to 3-4cm for TOPEX/Poseidon. To gain the most from these simultaneous datasets it is necessary to improve the orbital accuracy of ERS-1 so that it is commensurate with that of TOPEX/Poseidon. For the integration of these two datasets it is also necessary to determine the altimeter and sea state biases for each of the satellites. Several models for the sea state bias of ERS-1 are considered by analysis of the ERS-1 single satellite crossovers. The model adopted consists of the sea state bias as a percentage of the significant wave height, namely 5.95%. The removal of ERS-1 orbit error and recovery of an ERS-1 - TOPEX/Poseidon relative bias are both achieved by analysis of dual crossover residuals. The gravitational field based radial orbit error is modelled by a finite Fourier expansion series with the dominant frequencies determined by analysis of the JGM-2 co-variance matrix. Periodic and secular terms to model the errors due to atmospheric density, solar radiation pressure and initial state vector mis-modelling are also solved for. Validation of the dataset unification consists of comparing the mean sea surface topographies and annual variabilities derived from both the corrected and uncorrected ERS-1 orbits with those derived from TOPEX/Poseidon. The global and regional geographically fixed/variable orbit errors are also analysed pre and post correction, and a significant reduction is noted. Finally the use of dual/single satellite crossovers and repeat pass data, for the calibration of ERS-2 with respect to ERS-1 and TOPEX/Poseidon is shown by calculating the ERS-1/2 sea state and relative biases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

I sistemi BCI EEG-based sono un mezzo di comunicazione diretto tra il cervello e un dispositivo esterno il quale riceve comandi direttamente da segnali derivanti dall'attività elettrica cerebrale. Le features più utilizzate per controllare questi dispositivi sono i ritmi sensorimotori, ossia i ritmi mu e beta (8-30 Hz). Questi ritmi hanno la particolare proprietà di essere modulati durante l'immaginazione di un movimento generando così delle desincronizzazioni e delle sincronizzazioni evento correlate, ERD e ERS rispettavamente. Tuttavia i destinatari di tali sistemi BCI sono pazienti con delle compromissioni corticali e non sono sempre in grado di generare dei pattern ERD/ERS stabili. Per questo motivo, negli ultimi anni, è stato proposto l'uso di tecniche di stimolazione cerebrale non invasiva, come la tDCS, da abbinare al training BCI. In questo lavoro ci si è focalizzati sugli effetti della tDCS sugli ERD ed ERS neuronali indotti da immaginazione motoria attraverso un'analisi dei contributi presenti in letteratura. In particolare, sono stati analizzati due aspetti, ossia: i) lo studio delle modificazioni di ERD ed ERS durante (online) o in seguito (offline) a tDCS e ii) eventuali cambiamenti in termini di performance/controllo del sistema BCI da parte del soggetto sottoposto alla seduta di training e tDCS. Le ricerche effettuate tramite studi offline o online o con entrambe le modalità, hanno portato a risultati contrastanti e nuovi studi sarebbero necessari per chiarire meglio i meccanismi cerebrali che sottendono alla modulazione di ERD ed ERS indotta dalla tDCS. Si è infine provato ad ipotizzare un protocollo sperimentale per chiarire alcuni di questi aspetti.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lung cancer is the most frequently fatal cancer, with poor survival once the disease is advanced. Annual low-dose computed tomography has shown a survival benefit in screening individuals at high risk for lung cancer. Based on the available evidence, the European Society of Radiology and the European Respiratory Society recommend lung cancer screening in comprehensive, quality-assured, longitudinal programmes within a clinical trial or in routine clinical practice at certified multidisciplinary medical centres. Minimum requirements include: standardised operating procedures for low-dose image acquisition, computer-assisted nodule evaluation, and positive screening results and their management; inclusion/exclusion criteria; expectation management; and smoking cessation programmes. Further refinements are recommended to increase quality, outcome and cost-effectiveness of lung cancer screening: inclusion of risk models, reduction of effective radiation dose, computer-assisted volumetric measurements and assessment of comorbidities (chronic obstructive pulmonary disease and vascular calcification). All these requirements should be adjusted to the regional infrastructure and healthcare system, in order to exactly define eligibility using a risk model, nodule management and a quality assurance plan. The establishment of a central registry, including a biobank and an image bank, and preferably on a European level, is strongly encouraged. Key points: • Lung cancer screening using low dose computed tomography reduces mortality. • Leading US medical societies recommend large scale screening for high-risk individuals. • There are no lung cancer screening recommendations or reimbursed screening programmes in Europe as of yet. • The European Society of Radiology and the European Respiratory Society recommend lung cancer screening within a clinical trial or in routine clinical practice at certified multidisciplinary medical centres. • High risk, eligible individuals should be enrolled in comprehensive, quality-controlled longitudinal programmes.