914 resultados para ERROR BOUND


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In video communication systems, the video signals are typically compressed and sent to the decoder through an error-prone transmission channel that may corrupt the compressed signal, causing the degradation of the final decoded video quality. In this context, it is possible to enhance the error resilience of typical predictive video coding schemes using as inspiration principles and tools from an alternative video coding approach, the so-called Distributed Video Coding (DVC), based on the Distributed Source Coding (DSC) theory. Further improvements in the decoded video quality after error-prone transmission may also be obtained by considering the perceptual relevance of the video content, as distortions occurring in different regions of a picture have a different impact on the user's final experience. In this context, this paper proposes a Perceptually Driven Error Protection (PDEP) video coding solution that enhances the error resilience of a state-of-the-art H.264/AVC predictive video codec using DSC principles and perceptual considerations. To increase the H.264/AVC error resilience performance, the main technical novelties brought by the proposed video coding solution are: (i) design of an improved compressed domain perceptual classification mechanism; (ii) design of an improved transcoding tool for the DSC-based protection mechanism; and (iii) integration of a perceptual classification mechanism in an H.264/AVC compliant codec with a DSC-based error protection mechanism. The performance results obtained show that the proposed PDEP video codec provides a better performing alternative to traditional error protection video coding schemes, notably Forward Error Correction (FEC)-based schemes. (C) 2013 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Feature selection is a central problem in machine learning and pattern recognition. On large datasets (in terms of dimension and/or number of instances), using search-based or wrapper techniques can be cornputationally prohibitive. Moreover, many filter methods based on relevance/redundancy assessment also take a prohibitively long time on high-dimensional. datasets. In this paper, we propose efficient unsupervised and supervised feature selection/ranking filters for high-dimensional datasets. These methods use low-complexity relevance and redundancy criteria, applicable to supervised, semi-supervised, and unsupervised learning, being able to act as pre-processors for computationally intensive methods to focus their attention on smaller subsets of promising features. The experimental results, with up to 10(5) features, show the time efficiency of our methods, with lower generalization error than state-of-the-art techniques, while being dramatically simpler and faster.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we exploit the nonlinear property of the SiC multilayer devices to design an optical processor for error detection that enables reliable delivery of spectral data of four-wave mixing over unreliable communication channels. The SiC optical processor is realized by using double pin/pin a-SiC:H photodetector with front and back biased optical gating elements. Visible pulsed signals are transmitted together at different bit sequences. The combined optical signal is analyzed. Data show that the background acts as selector that picks one or more states by splitting portions of the input multi optical signals across the front and back photodiodes. Boolean operations such as EXOR and three bit addition are demonstrated optically, showing that when one or all of the inputs are present, the system will behave as an XOR gate representing the SUM. When two or three inputs are on, the system acts as AND gate indicating the present of the CARRY bit. Additional parity logic operations are performed using four incoming pulsed communication channels that are transmitted and checked for errors together. As a simple example of this approach, we describe an all-optical processor for error detection and then provide an experimental demonstration of this idea. (C) 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The SiC optical processor for error detection and correction is realized by using double pin/pin a-SiC:H photodetector with front and back biased optical gating elements. Data shows that the background act as selector that pick one or more states by splitting portions of the input multi optical signals across the front and back photodiodes. Boolean operations such as exclusive OR (EXOR) and three bit addition are demonstrated optically with a combination of such switching devices, showing that when one or all of the inputs are present the output will be amplified, the system will behave as an XOR gate representing the SUM. When two or three inputs are on, the system acts as AND gate indicating the present of the CARRY bit. Additional parity logic operations are performed by use of the four incoming pulsed communication channels that are transmitted and checked for errors together. As a simple example of this approach, we describe an all optical processor for error detection and correction and then, provide an experimental demonstration of this fault tolerant reversible system, in emerging nanotechnology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Considering tobacco smoke as one of the most health-relevant indoor sources, the aim of this work was to further understand its negative impacts on human health. The specific objectives of this work were to evaluate the levels of particulate-bound PAHs in smoking and non-smoking homes and to assess the risks associated with inhalation exposure to these compounds. The developed work concerned the application of the toxicity equivalency factors approach (including the estimation of the lifetime lung cancer risks, WHO) and the methodology established by USEPA (considering three different age categories) to 18 PAHs detected in inhalable (PM10) and fine (PM2.5) particles at two homes. The total concentrations of 18 PAHs (ΣPAHs) was 17.1 and 16.6 ng m−3 in PM10 and PM2.5 at smoking home and 7.60 and 7.16 ng m−3 in PM10 and PM2.5 at non-smoking one. Compounds with five and six rings composed the majority of the particulate PAHs content (i.e., 73 and 78 % of ΣPAHs at the smoking and non-smoking home, respectively). Target carcinogenic risks exceeded USEPA health-based guideline at smoking home for 2 different age categories. Estimated values of lifetime lung cancer risks largely exceeded (68–200 times) the health-based guideline levels at both homes thus demonstrating that long-term exposure to PAHs at the respective levels would eventually cause risk of developing cancer. The high determined values of cancer risks in the absence of smoking were probably caused by contribution of PAHs from outdoor sources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human chorionic gonadotropin (hCG) is a key diagnostic marker of pregnancy and an important biomarker for cancers in the prostate, ovaries and bladder and therefore of great importance in diagnosis. For this purpose, a new immunosensor of screen-printed electrodes (SPEs) is presented here. The device was fabricated by introducing a polyaniline (PANI) conductive layer, via in situ electropolymerization of aniline, onto a screen-printed graphene support. The PANI-coated graphene acts as the working electrode of a three terminal electrochemical sensor. The working electrode is functionalised with anti-hCG, by means of a simple process that enabled oriented antibody binding to the PANI layer. The antibody was attached to PANI following activation of the –COOH group at the Fc terminal. Functionalisation of the electrode was analysed and optimized using Electrochemical Impedance Spectroscopy (EIS). Chemical modification of the surface was characterised using Fourier transform infrared, and Raman spectroscopy with confocal microscopy. The graphene–SPE–PANI devices displayed linear responses to hCG in EIS assays from 0.001 to 50 ng mL−1 in real urine, with a detection limit of 0.286 pg mL−1. High selectivity was observed with respect to the presence of the constituent components of urine (urea, creatinine, magnesium chloride, calcium chloride, sodium dihydrogen phosphate, ammonium chloride, potassium sulphate and sodium chloride) at their normal levels, with a negligible sensor response to these chemicals. Successful detection of hCG was also achieved in spiked samples of real urine from a pregnant woman. The immunosensor developed is a promising tool for point-of-care detection of hCG, due to its excellent detection capability, simplicity of fabrication, low-cost, high sensitivity and selectivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

5th Brazilian Symposium on Computing Systems Engineering, SBESC 2015 (SBESC 2015). 3 to 6, Nov, 2015. Foz do Iguaçu, Brasil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

J Biol Inorg Chem (2008) 13:1321–1333 DOI 10.1007/s00775-008-0416-1

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Sistemas de Bioengenharia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation for obtaining the Master degree in Membrane Engineering

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is mainly concerned with the tracking accuracy of Exchange Traded Funds (ETFs) listed on the London Stock Exchange (LSE) but also evaluates their performance and pricing efficiency. The findings show that ETFs offer virtually the same return but exhibit higher volatility than their benchmark. It seems that the pricing efficiency, which should come from the creation and redemption process, does not fully hold as equity ETFs show consistent price premiums. The tracking error of the funds is generally small and is decreasing over time. The risk of the ETF, daily price volatility and the total expense ratio explain a large part of the tracking error. Trading volume, fund size, bid-ask spread and average price premium or discount did not have an impact on the tracking error. Finally, it is concluded that market volatility and the tracking error are positively correlated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluated the efficacy of the Old Way/New Way methodology (Lyndon, 1989/2000) with regard to the permanent correction of a consolidated and automated technical error experienced by a tennis athlete (who is 18 years old and has been engaged in practice mode for about 6 years) in the execution of serves. Additionally, the study assessed the impact of intervention on the athlete’s psychological skills. An individualized intervention was designed using strategies that aimed to produce a) a detailed analysis of the error using video images; b) an increased kinaesthetic awareness; c) a reactivation of memory error; d) the discrimination and generalization of the correct motor action. The athlete’s psychological skills were measured with a Portuguese version of the Psychological Skills Inventory for Sports (Cruz & Viana, 1993). After the intervention, the technical error was corrected with great efficacy and an increase in the athlete’s psychological skills was verified. This study demonstrates the methodology’s efficacy, which is consistent with the effects of this type of intervention in different contexts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El objetivo que persigue un proceso de auditoría de estados contables es la comunicación por parte del auditor de una conclusión en relación al grado de razonabilidad con que tales estados reflejan la situación patrimonial, económica y financiera del ente de acuerdo a los criterios plasmados en las normas contables de referencia a ser utilizadas. El hecho que un auditor emita una conclusión errónea como consecuencia de su labor puede implicar la asunción de responsabilidades profesionales, civiles y penales como consecuencia de reclamos de usuarios de los estados contables que pudieran haberse visto perjudicados como consecuencia de la emisión de la conclusión errónea. Las normas contables a nivel nacional e internacional admiten la existencia de errores u omisiones en la información contenida en los estados contables, en la medida que tales desvíos no provoquen en los usuarios interesados en tales estados una decisión distinta a la que tomarían en caso de no existir los errores u omisiones aludidos. De lo expuesto en el párrafo anterior surge la cabal importancia que la determinación del nivel de significación total (nivel de desvíos admitidos por los usuarios de los estados contables en la información por ellos contenida) adquiere en los procesos de auditoría, como así también la asignación de tal nivel entre los distintos componentes de los estados contables (asignación del error tolerable) a los efectos de que los auditores eviten asumir responsabilidades de índole profesional, civil y/o penal. Hasta el momento no se conoce la existencia de modelos matemáticos que respalden de modo objetivo y verificable el cálculo del nivel de significación total y la asignación del error tolerable entre los distintos elementos conformantes de los estados contables. Entendemos que el desarrollo e integración de un modelo de cuantificación del nivel de significación total y de asignación del error tolerable tiene las siguientes repercusiones: 1 – Representaría para el auditor un elemento que respalde el modo de cuantificación del nivel de significación y la asignación del error tolerable entre los componentes de los estados contables. 2 – Permitiría que los auditores reduzcan las posibilidades de asumir responsabilidades de carácter profesional, civil y/o penales como consecuencia de su labor. 3 – Representaría un principio de avance a los efectos de que los organismos emisores de normas de auditoría a nivel nacional e internacional recepten elementos a los efectos de fijar directrices en relación al cálculo del nivel de significación y de asignación del error tolerable. 4 - Eliminaría al cálculo del nivel de significación como una barrera que afecte la comparabilidad de los estados contables.