147 resultados para EMC


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effects of mimosine (MI), which is an amino acid that is derived from Leucaena leucocephala, were evaluated on the growth of ascitic Ehrlich tumors, and the effects of the combination treatment of MI and cyclophosphamide (CY) on tumor growth were also assessed. Mice were divided into groups that received the following treatments over the course of 20 days: phosphate buffer solution (CO), MI, Ehrlich cells (E), E plus CY (EC), E plus MI (EM) and E plus MI and CY (EMC). No signs of toxicity were detected in the mice from the MI group. The mice from the EMC group showed reductions in body weights when compared with those from the E group. The animals from the EC, EM and EMC groups showed reductions in ascitic volume compared with those from the E group. The mice from the EMC group showed reductions in total cell numbers of ascitic fluid compared with those from the E, EC and EM groups. The combination of MI and CY was the most effective treatment for Ehrlich tumor ascites.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, metamaterial patterns are applied to a GTEM – Gigahertz Transverse Electromagnetic Chamber to improve and give flexibility to its frequency response. The main goal is to achieve a better frequency resonance regardless the dimensions of the original chamber. Therefore, a comparison between the CLL – Capacitively Loaded Loop and Fractal metamaterial technology for these purposes, is done. Experimental results are compared to the simulated ones

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Topologies of motor drive systems are studied, aiming the reduction of common-mode (CM) currents. Initially, the aspects concerning the CM currents circulation are analysed. The reason of common-mode voltages generation, the circulating paths for the resulting CM currents and their effects are discussed. Then, a non-conventional drive system configuration is proposed in order to reduce the CM currents and their effects. This configuration comprehends a non-conventional inverter module wired to a motor with an unusual connection. The cables arrangement differs from the standard solution, too. The proposed topology is compared with other ones, like the active circuit for common-mode voltages compensation. The contribution of the configuration to the reduction of CM voltages and currents and their related interferences are evaluated, based on numerical simulations. Some results are presented and discussed regarding the suitability of the proposed configuration as a potential solution to reduce the CM currents effects, when the state of art and implementation cost of drives are taken into account.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBIETTIVO : Quantificare le CECs/ml nei pazienti affetti da ischemia critica (IC) degli arti inferiori, eventuali correlazioni tra i fattori di rischio, lo stadio clinico con l’ aumento delle CECs. Valutare i cambiamenti strutturali (calcificazione ed infiltratto infiammatorio) e l’ angiogenesi (numero di capillari /sezione) della parete arteriosa. MATERIALI E METODI: Da Maggio 2006 ad Aprile 2008 in modo prospettico abbiamo arruolato paziente affetti da IC da sottoporre ad intervento chirurgico. In un data base abbiamo raccolto : caratteristiche demografiche, fattori di rischio, stadiazione dell'IC secondo Leriche-Fontaine (L-F), il tipo di intervento chirurgico. Per ogni paziente abbiamo effettuato un prelievo ematico di 2 ml per la quantificazione immunomagnetica delle CECs e prelievo di parete arteriosa. RISULTATI: In modo consecutivo abbiamo arruolato 33 pazienti (75.8% maschi) con età media di 71 aa (range 34-91aa), affetti da arteriopatia ostruttiva cronica periferica al IV stadio di L-F nel 84.8%, da cardiopatia ischemica cronica nel 60.6%, da ipertensione arteriosa nel 72.7% e da diabete mellito di II tipo nel 66.6%. Il valore medio di CECs/ml è risultato significativamente più elevato (p= 0.001) nei soggetti affetti da IC (CECs/ml =531.24 range 107- 3330) rispetto ai casi controllo (CECs/ml = 125.8 range 19-346 ). Le CECs/ml nei pazienti diabetici sono maggiori rispetto alle CECs/ml nei pazienti non diabetici ( 726.7 /ml vs 325.5/ml ), p< 0.05 I pazienti diabetici hanno presentato maggior incidenza di lesioni arteriose complesse rispetto ai non diabetici (66% vs 47%) e minor densità capillare (65% vs 87%). Conclusioni : Le CECs sono un marker sierologico attendibile di danno vascolare parietale, la loro quantità è maggiore nei pazienti diabetici e ipertesi. La minor capacità angiogenetica della parete arteriosa in presenza di maggior calcificazioni ed infiltrato infiammatorio nei diabetici, dimostra un danno istopatologico di parete maggiore .

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Le tematiche relative alla compatibilità elettromagnetica (EMC) dei dispositivi elettronici (sia per il trasferimento dell'informazione che per trasmissione e conversione di potenza) sono di grande attualità a causa di molteplici fattori. Il primo è la larga diffusione di apparecchiature elettroniche e delle telecomunicazioni in svariati ambienti. Secondariamente tali dispositivi sono sempre più suscettibili al rumore per ragioni tecniche: -tensioni di alimentazione sempre più basse (alimentazione a batterie); -aumento della velocità dei dispositivi; -miniaturizzazione; -connettività wireless (spesso con diversi protocolli sullo stesso device). All'interno di questa tesi vengono trattate le interferenze elettromagnetiche (EMI) con riferimento ad una categoria specifica di prodotti (i caricabatterie)ed approfondendo in particolare le cause e le principali tecniche per limitarne l'effetto, al fine di ottenere la compatibilità dei dispositivi. Le tecniche per abbattere le EMI presentate sono poi applicate a dispositivi commerciali per valutarne gli effetti. Il lavoro è stato svolto presso la Deca di San Marino che ha messo a disposizione un laboratorio EMC (dotato di LISN PMM L3-64, Ricevitore PMM 9010/30P full-compliance e AbsorbingClamp TESEQ) ed alcuni propri prodotti.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The spectrum characteristic of the EMC ranges from eclogites (containing omphacite and/or jadeite, garnet, phengite, glaucophane, zoisite, chloritoid, rutile) to phengite schists, calcschists, and marbles, as well as a variety of orthogneisses. Despite the intense polyphase deformation and HP-metamorphic recrystallization, it is possible in some locations to recognize pre-Alpine characteristics in some of the protoliths. For instance, two types of felsic orthogneiss can be distinguished in the Aosta Valley, one derived from Permian granitoids (with local preservation of intrusive contacts, magmatic inclusions, leucocratic veins and other magmatic structures; Stop 3), the other derived from pre-Variscan leuco-monzogranite, such as the building stone mined at the “Argentera” quarry near Settimo Vittone / Montestrutto (Stop 2; so-called “Verde Argento” contains jadeite, phengite, K-feldspar, quartz). Polycyclic and more rarely monocyclic metasediments contain evidence of a complex Alpine PTDt-evolution, locally including relics of their prograde history from blueschist, one or more stages at eclogite facies. Recent petrochronological studies have dated this HP-evolution of the Sesia Zone in some detail. In the area visited, clear evidence of HP-cycling has been identified in one km-size tectonic slice (Stop 1), but not in adjacent parts of the EMC, indicating “yo-yo tectonics”. Partial retrogression and attendant ductile to brittle deformation of the HP-rocks is evident in one of the outcrops (Stop 4). Apart from the four localities in the Sesia Zone, a final outcrop introduces HP-rocks of the adjacent Piemonte oceanic unit, specifically calc-schists and ophiolite members of the “Zermatt-Saas” zone. The hilltop outcrop (Stop 5) displays foliated antigorite schist with peridotite relics (clinopyroxene, spinel) containing lenses derived from doleritic dykes. These fine-grained metarodingites and the folded veins containing Mg-chlorite and titanoclinohumite within serpentinite once again indicate equilibration under low-temperature eclogite facies conditions. However, these units reached that HP stage more than 20 Ma after the youngest eclogite facies imprint recognized in the Sesia Zone. Despite nearly half a century of intense study in the Sesia Zone, the complex assembly of its HP-terranes and their relation to more external parts of the Western Alps remains incompletely understood. This field guide merely introduces a few of the classic outcrops and discusses some of the critical evidence they contain, but it could not incorporate details on each stage of the evolution recognized so far.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El presente estudio recopila los diferentes bancos de pruebas de EMC, Radio, SAR y seguridad eléctrica que se utiliza en la vigilancia del mercado. Describe las pruebas realizadas por el Estado español para llevar a cabo el seguimiento y control de los equipos vendidos. En primer lugar se presenta una descripción cualitativa de los ambientes clasificados por requisitos que explica en qué consisten las pruebas que se hacen, cómo se configura el entorno de medida y cuáles son los equipos que se deben utilizar. Está ilustrado con fotografías de los bastidores, antenas, amplificadores, generadores y otros equipos que la SETSI tiene en su laboratorio en El Casar (Guadalajara). La vigilancia de los equipos se realiza periódicamente en los estados miembros de la Unión Europea. Los funcionarios responsables también se reúnen periódicamente a nivel europeo para sacar conclusiones y hacer proyecciones futuras. El equipo adquirido en centros comerciales de venta al público, después de poco más de un mes, en el que se pasan las pruebas, vuelve a la cadena de comercialización, por lo que los dispositivos no se puedan dañar. Las pruebas realizadas en el laboratorio no pueden ser perjudiciales para los dispositivos por lo que es necesario tomar precauciones en la ejecución de las pruebas. El centro del PFC es el área de la Seguridad Eléctrica. El capítulo 4 es una reproducción de la Norma internacional IEC 60950-1:2007/A11 sobre seguridad en equipos de tecnología de la información adaptada a los requisitos de la vigilancia de mercado. Las autoridades competentes se basan en este estándar para evaluar y garantizar la seguridad del usuario en los equipos de consumo. Diseñados los procedimientos de ensayo y montado un banco de acuerdo a estos ensayos, se ha preparado un manual de operador, capítulo 5, en el que se recogen cada una de las pruebas y controles visuales que deben realizarse para probar que el equipo es conforme. Para finalizar, en el capítulo 6, se ejecutan ensayos de ejemplo sobre tres dispositivos de prueba y se elaboran las correspondientes hojas de ensayo. El propósito es proporcionar al operador un manual completo del banco de seguridad eléctrica, es por ello que en el manual de operador se han repetido muchos fragmentos de la norma para facilitar al operador el objetivo concreto de las pruebas y el acceso fácil a la información. This dissertation presents the different test benches of EMC, Radio, SAR and Electrical Safety that are used in market surveillance. Describes the tests performed by the Spanish State to carry out the monitoring and control of equipment sold. First a qualitative description of the environments classified by requisites that explains in that consist the tests that are make it, how it configures the measure environment and which are the equipment that it should use. It is illustrated with photographs of the racks, antennas, amplifiers, generators and other equipment that the S.E.T.S.I has in its laboratory on El Casar (Guadalajara). The surveillance of equipment is performed periodically in the member states of the European Union. Responsible officials also periodically meet at European level to draw conclusions and make future projections. The equipment purchased in malls public sale, after little more than a month, in which the tests are passed, returned to the trade chain, which is why the devices cannot be damaged. The tests done in the laboratory may not be harmful for devices are thus necessary to take precautions in the execution of the tests. The center of this dissertation is the area of Electrical Safety. Chapter 4 is a reproduction of the International Standard IEC 60950-1:2007/A11 safety in teams of information technology, adapted to the requirements of market surveillance. The competent authorities are based on this standard to assess and ensure the user's safety in the consumption equipment. Designed test procedures and mounted on a bench according to these tests, it has prepared a manual operator, in Chapter 5, with each of the tests and visual inspections in order to prove that the equipment complies. Finally, in Chapter 6, such tests run on three devices are developed test and test some leaves. The purpose of this book is to provide an operator manual of the bench of electrical safety, which is why the operator manual have been repeated fragments of the standard, in chapter 5, to facilitate the operator to test execution and access to information.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The goal of this study was to identify the circulating cell that is the immediate precursor of tissue macrophages. ROSA 26 marrow mononuclear cells (containing the β-geo transgene that encodes β-galactosidase and neomycin resistance activities) were cultured in the presence of macrophage colony-stimulating factor and flt3 Ligand for 6 days to generate monocytic cells at all stages of maturation. Expanded monocyte cells (EMC), the immature (ER-MP12+) and more mature (ER-MP20+) subpopulations, were transplanted into irradiated B6/129 F2 mice. β-gal staining of tissue sections from animals 15 min after transplantation demonstrated that the donor cells landed randomly. By 3 h, donor cells in lung and liver were more frequent in animals transplanted with ER-MP20+ (more mature) EMC than in animals transplanted with unseparated EMC or fresh marrow mononuclear cells, a pattern that persisted at 3 and 7 days. At 3 days, donor cells were found in spleen, liver, lung, and brain (rarely) as clusters as well as individual cells. By 7 and 14 days, the clusters had increased in size, and the cells expressed the macrophage antigen F4/80, suggesting that further replication and differentiation had occurred. PCR for the neogene was used to quantitate the amount of donor DNA in tissues from transplanted animals and confirmed that ER-MP20+ EMC preferentially engrafted. These data demonstrate that a mature monocytic cell gives rise to tissue macrophages. Because these cells can be expanded and manipulated in vitro, they may be a suitable target population for gene therapy of lysosomal storage diseases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Irregular facets (If) is a dominant mutation of Drosophila that results in small eyes with fused ommatidia. Previous results showed that the gene Krüppel (Kr), which is best known for its early segmentation function, is expressed ectopically in If mutant eye discs. However, it was not known whether ectopic Kr activity is either the cause or the result of the If mutation. Here, we show that If is a gain-of-function allele of Kr. We then used the If mutation in a genetic screen to identify dominant enhancers and suppressors of Kr activity on the third chromosome. Of 30 identified Kr-interacting loci, two were cloned, and we examined whether they also represent components of a natural Kr-dependent developmental pathway of the embryo. We show that the two genes, eyelid (eld) and extramacrochaetae (emc), which encode a Bright family-type DNA binding protein and a helix-loop-helix factor, respectively, are necessary to achieve the singling-out of a unique Kr-expressing cell during the development of the Malpighian tubules, the excretory organs of the fly. The results indicate that the Kr gain-of-function mutation If provides a tool to identify genes that are active during eye development and that a number of them function also in the control of Kr-dependent developmental processes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Relatório de Trabalho de Projeto apresentado para cumprimento dos requisitos necessários à obtenção do grau de Mestre em Enfermagem Médico-Cirúrgica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Federal Highway Administration, Washington, D.C.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

National Highway Traffic Safety Administration, Washington, D.C.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Federal Highway Administration, Office of Research and Development, Washington, D.C.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Federal Highway Administration, Office of Safety and Traffic Operations, Washington, D.C.