925 resultados para EDGE FILTERS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND It is unknown if lack of polymer can provoke a different edge response in drug-eluting stents. The aim of this study was to compare edge vascular response between polymer-free paclitaxel-eluting stent (PF-PES) and polymer-based paclitaxel-eluting stents (PB-PES). METHODS AND RESULTS: A total of 165 eligible patients undergoing percutaneous coronary intervention were prospectively randomized 1:1 to receive either PF-PES or PB-PES. Those patients with paired intravascular ultrasound (IVUS) after procedure and at 9-month follow-up were included in this analysis.Seventy-six patients with 84 lesions, divided into PB-PES (38 patients, 41 lesions) and PF-PES groups (38 patients, 43 lesions) had paired post-procedure and 9-month follow-up IVUS and were therefore included in this substudy. There was a significant lumen decrease at the proximal edge of PF-PES (from 9.02±3.06 mm(2)to 8.47±3.05 mm(2); P=0.040), and a significant plaque increase at the distal edges of PF-PES (from 4.39±2.73 mm(2)to 4.78±2.63 mm(2); P=0.004). At the distal edge there was a significant plaque increase in the PF-PES compared to PB-PES (+8.0% vs. -0.6%, respectively; P=0.015) with subsequent lumen reduction (-5.2% vs. +6.0%, respectively; P=0.024). CONCLUSIONS PF-PES had significant plaque increase and lumen reduction at the distal edge as compared to PB-PES, probably due to difference in polymer-based drug-release kinetics between the 2 platforms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a novel filtering method for multispectral satellite image classification. The proposed method learns a set of spatial filters that maximize class separability of binary support vector machine (SVM) through a gradient descent approach. Regularization issues are discussed in detail and a Frobenius-norm regularization is proposed to efficiently exclude uninformative filters coefficients. Experiments carried out on multiclass one-against-all classification and target detection show the capabilities of the learned spatial filters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The advent of retrievable caval filters was a game changer in the sense, that the previously irreversible act of implanting a medical device into the main venous blood stream of the body requiring careful evaluation of the pros and cons prior to execution suddenly became a "reversible" procedure where potential hazards in the late future of the patient lost most of their weight at the time of decision making. This review was designed to assess the rate of success with late retrieval of so called retrievable caval filters in order to get some indication about reasonable implant duration with respect to relatively "easy" implant removal with conventional means, i.e., catheters, hooks and lassos. A PubMed search (www.pubmed.gov) was performed with the search term "cava filter retrieval after 30 days clinical", and 20 reports between 1994 and 2013 dealing with late retrieval of caval filters were identified, covering approximately 7,000 devices with 600 removed filters. The maximal duration of implant reported is 2,599 days and the maximal implant duration of removed filters is also 2,599 days. The maximal duration reported with standard retrieval techniques, i.e., catheter, hook and/or lasso, is 475 days, whereas for the retrievals after this period more sophisticated techniques including lasers, etc. were required. The maximal implant duration for series with 100% retrieval accounts for 84 days, which is equivalent to 12 weeks or almost 3 months. We conclude that retrievable caval filters often become permanent despite the initial decision of temporary use. However, such "forgotten" retrievable devices can still be removed with a great chance of success up to three months after implantation. Conventional percutaneous removal techniques may be sufficient up to sixteen months after implantation whereas more sophisticated catheter techniques have been shown to be successful up to 83 months or more than seven years of implant duration. Tilting, migrating, or misplaced devices should be removed early on, and replaced if indicated with a device which is both, efficient and retrievable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose an edge detector based on the selection of wellcontrasted pieces of level lines, following the proposal ofDesolneux-Moisan-Morel (DMM) [1]. The DMM edge detectorhas the problem of over-representation, that is, everyedge is detected several times in slightly different positions.In this paper we propose two modifications of the originalDMM edge detector in order to solve this problem. The firstmodification is a post-processing of the output using a generalmethod to select the best representative of a bundle of curves.The second modification is the use of Canny’s edge detectorinstead of the norm of the gradient to build the statistics. Thetwo modifications are independent and can be applied separately.Elementary reasoning and some experiments showthat the best results are obtained when both modifications areapplied together.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Toll-like receptors (TLRs) are key mediators of the innate immune response to microbial pathogens. We investigated the role of TLRs in the recognition of Mycobacterium leprae and the significance of TLR2Arg(677)Trp, a recently discovered human polymorphism that is associated with lepromatous leprosy. In mice, TNF-alpha production in response to M. leprae was essentially absent in TLR2-deficient macrophages. Similarly, human TLR2 mediated M. leprae-dependent activation of NF-kappaB in transfected Chinese hamster ovary and human embryonic kidney 293 cells, with enhancement of this signaling in the presence of CD14. In contrast, activation of NF-kappaB by human TLR2Arg(677)Trp was abolished in response to M. leprae and Mycobacterium tuberculosis. The impaired function of this TLR2 variant provides a molecular mechanism for the poor cellular immune response associated with lepromatous leprosy and may have important implications for understanding the pathogenesis of other mycobacterial infections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A vehicle may leave its travel lane for a number of reasons, such as driver error, poor surface conditions, or avoidance of a collision with another vehicle in the travel lane. When a vehicle leaves the travel lane, pavement edge drop-off poses a potential safety hazard because significant vertical differences between surfaces can affect vehicle stability and reduce a driver’s ability to handle the vehicle. Numerous controlled studies have tested driver response to encountering drop-offs under various conditions, including different speeds, vehicle types, drop-off height and shape, and tire scrubbing versus non-scrubbing conditions. The studies evaluated the drivers’ ability to return to and recover within their own travel lane after leaving the roadway and encountering a drop-off. Many of these studies, however, have used professional drivers as test subjects, so results may not always apply to the population of average drivers. Furthermore, test subjects are always briefed on what generally is to be expected and how to respond; thus, the sense of surprise that a truly naïve driver may experience upon realizing that one or two of his or her tires have just dropped off the edge of the pavement, is very likely diminished. Additionally, the studies were carried out under controlled conditions. The actual impact of pavement edge drop-off on drivers’ ability to recover safely once they leave the roadway, however, is not well understood under actual driving conditions. Additionally, little information is available that quantifies the number or severity of crashes that occur where pavement edge drop-off may have been a contributing factor. Without sufficient information about the frequency of edge drop-off-related crashes, agencies are not fully able to measure the economic benefits of investment decisions, evaluate the effectiveness of different treatments to mitigate edge drop-off, or focus maintenance resources. To address these issues, this report details research to quantify the contribution of pavement edge drop-off to crash frequency and severity. Additionally, the study evaluated federal and state guidance in sampling and addressing pavement edge drop-off and quantified the extent of pavement edge drop-off in two states. This study focused on rural two-lane paved roadways with unpaved shoulders, since they are often high speed facilities (55+ mph), have varying levels of maintenance, and are likely to be characterized by adverse roadway conditions such as narrow lanes or no shoulders.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although NK cells in the mouse are thought to develop in the bone marrow, a small population of NK cells in the thymus has been shown to derive from a GATA3-dependent pathway. Characteristically, thymic NK cells express CD127 and few Ly49 molecules and lack CD11b. Because these NK cells develop in the thymus, the question of their relationship to the T cell lineage has been raised. Using several different mouse models, we find that unlike T cells, thymic NK cells are not the progeny of Rorc-expressing progenitors and do not express Rag2 or rearrange the TCRγ locus. We further demonstrate that thymic NK cells develop independently of the Notch signaling pathway, supporting the idea that thymic NK cells represent bona fide NK cells that can develop independently of all T cell precursors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clinical use of antibiotics is based on their capacity to inhibit bacterial growth via bacteriostatic or bacteriocidal effects. In this article, we show that the aminoglycoside antibiotic neomycin, the cyclic lipopeptide antibiotic polymyxin B, and the cyclic peptide antibiotics gramicidin and tyrothricin can induce IL-1β secretion in bone marrow dendritic cells and macrophages. LPS priming was required to trigger the transcription and translation of pro-IL-1β but was independent of TNFR or IL-1R signaling. All four antibiotics required the NLRP3 inflammasome, the adaptor ASC, and caspase-1 activation to secrete IL-1β, a process that depended on potassium efflux but was independent of P2X7 receptor. All four antibiotics induced neutrophil influx into the peritoneal cavity of mice, which required NLRP3 only in the case of polymyxin B. Together, certain antibiotics have the potential to directly activate innate immunity of the host.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to determine whether the filters used in microirrigation systems can remove potentially emitter-clogging particles. The particle size and volume distributions of different effluents and their filtrates were established, and the efficiency of the removal of these particles and total suspended solids by screen, disc and sand filters determined. In most of the effluents and filtrates, the number of particles with a diameter > 20 μm was minimal. By analysing the particle volume distribution it was found that particles larger than the disc and screen filter pores appeared in the filtrates. However, the sand filter was able to retain particles larger than the pore size. The filtration efficiency depended more on the type of effluent than on the filter. It was also found that the particle size distribution followed a potential law. Analysis of the β exponents showed that the filters did not significantly modify the particle size distribution of the effluents

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: We describe the results of a preliminary prospective study using different recently developed temporary and retrievable inferior vena cava (IVC) filters. METHODS: Fifty temporary IVC filters (Gunther, Gunther Tulip, Antheor) were inserted in 47 patients when the required period of protection against pulmonary embolism (PE) was estimated to be less than 2 weeks. The indications were documented deep vein thrombosis (DVT) and temporary contraindications for anticoagulation, a high risk for PE, and PE despite DVT prophylaxis. RESULTS: Filters were removed 1-12 days after placement and nine (18%) had captured thrombi. Complications were one PE during and after removal of a filter, two minor filter migrations, and one IVC thrombosis. CONCLUSION: Temporary filters are effective in trapping clots and protecting against PE, and the complication rate does not exceed that of permanent filters. They are an alternative when protection from PE is required temporarily, and should be considered in patients with a normal life expectancy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interactions between Notch1 receptors on lymphoid progenitors and Delta-like 4 (DL4) ligands on cortical thymic epithelial cells (cTEC) are essential for T cell lineage commitment, expansion, and maturation in the thymus. Using a novel mAb against DL4, we show that DL4 levels on cTEC are very high in the fetal and neonatal thymus when thymocyte expansion is maximal but decrease dramatically in the adult when steady-state homeostasis is attained. Analysis of mutant mouse strains where thymocyte development is blocked at different stages indicates that lymphostromal interactions ("thymus crosstalk") are required for DL4 down-regulation on cTEC. Reconstitution of thymocyte development in these mutant mice further suggests that maturation of thymocytes to the CD4(+)CD8(+) stage and concomitant expansion are needed to promote DL4 down-regulation on cTEC. Collectively, our data support a model where thymic crosstalk quantitatively regulates the rate of Notch1-dependent thymopoiesis by controlling DL4 expression levels on cTEC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The UL144 open reading frame found in clinical isolates of human CMV (HCMV) encodes a structural homologue of the herpesvirus entry mediator, a member of the TNFR superfamily. UL144 is a type I transmembrane glycoprotein that is expressed early after infection of fibroblasts; however, it is retained intracellularly. A YXXZ motif in the highly conserved cytoplasmic tail contributes to UL144 subcellular distribution. The finding that no known ligand of the TNF family binds UL144 suggests that its mechanism of action is distinct from other known viral immune evasion genes. Specific Abs to UL144 can be detected in the serum of a subset of HCMV seropositive individuals infected with HIV. This work establishes a novel molecular link between the TNF superfamily and herpesvirus that may contribute to the ability of HCMV to escape immune clearance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Inductive-based devices integrated with Si technology for biodetection applications are characterized, using simple resonant differential filter configurations. This has allowed the corroboration of the viability of the proposed circuits, which are characterized by their very high simplicity, for microinductive signal conditioning in high-sensitivity sensor devices. The simulation of these simple circuits predicts sensitivities of the differential output voltage which can achieve values in the range of 0.1-1 V/nH, depending on the coil parameters. These very high-sensitivity values open the possibility for the experimental detection of extremely small inductance changes in the devices. For real microinductive devices, both series resistance and parasitic capacitive components contribute to the decrease of the differential circuit sensitivity. Nevertheless, measurements performed using micro-coils fabricated with relatively high series resistance and coupling parasitic effects have allowed detection of changes in the range of 2 nH. which are compatible with biodetection applications with estimated detection limits below the picomolarity range.

Relevância:

20.00% 20.00%

Publicador: