864 resultados para Drinking vessels.
Resumo:
People in many countries are affected by fluorosis owing to the high levels of fluoride in drinking water. An inexpensive method for estimating the concentration of the fluoride ion in drinking water would be helpful in identifying safe sources of water and also in monitoring the performance of defluoridation techniques. For this purpose, a simple, inexpensive, and portable colorimeter has been developed in the present work. It is used in conjunction with the SPADNS method, which shows a color change in the visible region on addition of water containing fluoride to a reagent solution. Groundwater samples were collected from different parts of the state of Karnataka, India and analysed for fluoride. The results obtained using the colorimeter and the double beam spectrophotometer agreed fairly well. The costs of the colorimeter and of the chemicals required per test were about Rs. 250 (US$ 5) and Rs. 2.5 (US$ 0.05), respectively. In addition, the cost of the chemicals required for constructing the calibration curve was about Rs. 15 (US$ 0.3). (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Existing models for dmax predict that, in the limit of μd → ∞, dmax increases with 3/4 power of μd. Further, at low values of interfacial tension, dmax becomes independent of σ even at moderate values of μd. However, experiments contradict both the predictions show that dmax dependence on μd is much weaker, and that, even at very low values of σ,dmax does not become independent of it. A model is proposed to explain these results. The model assumes that a drop circulates in a stirred vessel along with the bulk fluid and repeatedly passes through a deformation zone followed by a relaxation zone. In the deformation zone, the turbulent inertial stress tends to deform the drop, while the viscous stress generated in the drop and the interfacial stress resist deformation. The relaxation zone is characterized by absence of turbulent stress and hence the drop tends to relax back to undeformed state. It is shown that a circulating drop, starting with some initial deformation, either reaches a steady state or breaks in one or several cycles. dmax is defined as the maximum size of a drop which, starting with an undeformed initial state for the first cycle, passes through deformation zone infinite number of times without breaking. The model predictions reduce to that of Lagisetty. (1986) for moderate values of μd and σ. The model successfully predicts the reduced dependence of dmax on μd at high values of μd as well as the dependence of dmax on σ at low values of σ. The data available in literature on dmax could be predicted to a greater accuracy by the model in comparison with existing models and correlations.
Resumo:
Existing models for dmax predict that, in the limit of μd → ∞, dmax increases with 3/4 power of μd. Further, at low values of interfacial tension, dmax becomes independent of σ even at moderate values of μd. However, experiments contradict both the predictions show that dmax dependence on μd is much weaker, and that, even at very low values of σ,dmax does not become independent of it. A model is proposed to explain these results. The model assumes that a drop circulates in a stirred vessel along with the bulk fluid and repeatedly passes through a deformation zone followed by a relaxation zone. In the deformation zone, the turbulent inertial stress tends to deform the drop, while the viscous stress generated in the drop and the interfacial stress resist deformation. The relaxation zone is characterized by absence of turbulent stress and hence the drop tends to relax back to undeformed state. It is shown that a circulating drop, starting with some initial deformation, either reaches a steady state or breaks in one or several cycles. dmax is defined as the maximum size of a drop which, starting with an undeformed initial state for the first cycle, passes through deformation zone infinite number of times without breaking. The model predictions reduce to that of Lagisetty. (1986) for moderate values of μd and σ. The model successfully predicts the reduced dependence of dmax on μd at high values of μd as well as the dependence of dmax on σ at low values of σ. The data available in literature on dmax could be predicted to a greater accuracy by the model in comparison with existing models and correlations.
Resumo:
New metallurgical and ethnographic observations of the traditional manufacture of specular high-tin bronze mirrors in Kerala state of southern India are discussed, which is an exceptional example of a surviving craft practice of metal mirror-making in the world. The manufacturing process has been reconstructed from analytical investigations made by Srinivasan following a visit late in 1991 to a mirror making workshop and from her technical studies of equipment acquired by Glover in March 1992 from another group of mirror makers from Pathanamthita at an exhibition held at Crafts Museum, Delhi. Finished and unfinished mirror from two workshops were of a binary, copper-tin alloy of 33% tin which is close to the composition of pure delta phase, so that these mirrors are referred to here as ‘delta’ bronzes. For the first time, metallurgical and field observations were made by Srinivasan in 1991 of the manufacture of high-tin ‘beta’ bonze vessels from Palghat district, Kerala, i‥e of wrought and quenched 23% tin bronze. This has provided the first metallurgical record for a surviving craft of high-tin bronze bowl making which can be directly related to archaeological finds of high-tin bronze vessels from the Indian subcontinent and Southeast Asia. New analytical investigations are presented of high-tin beta bronzes from the Indian subcontinent which are some of the earliest reported worldwide. These coupled with the archaeometallurgical evidence suggests that these high-tin bronze techniques are part of a long, continuing, and probably indigenous tradition of the use of high-tin bronzes in the Indian subcontinent with finds reported even from Indus Valley sites. While the source of tin has been problematic, new evidence on bronze smelting slags and literary evidence suggests there may have been some sources of tin in South India.
Resumo:
Drop breakup inviscous liquids in agitated vessels occurs in elongational flow around impeller blade edges. The drop size distributions measured over extended periods for impellers of different sizes show that breakup process continues up to 15-20 h, before a steady state is reached. The size distributions evolve in a self-similar way till the steady state is reached. The scaled size distributions vary with impeller size and impeller speed, in contrast with the near universal scaling known for drop breakup in turbulent flows. The steady state size of the largest drop follows inverse scaling with impeller tip velocity. The breadth of the scaled size distributions also shows a monotonic relationship with impeller tip velocity only. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
The quality of tap water from water supplies from 14 districts of Kerala state, India was studied. Parameters like pH, water temperature, total dissolved solids, salinity, nitrates, chloride, hardness, magnesium, calcium, sodium, potassium, fluoride, sulphate, phosphates, and coliform bacteria were enumerated. The results showed that all water samples were contaminated by coliform bacteria. About 20% of the tap water samples from Alappuzha and 15% samples from Palakkad district are above desirable limits prescribed by Bureau of Indian Standards. The contamination of the source water (due to lack of community hygiene) and insufficient treatment are the major cause for the coliform contamination in the state. Water samples from Alappuzha and Palakkad have high ionic and fluoride content which could be attributed to the geology of the region. Water supplied for drinking in rural areas are relatively free of any contamination than the water supplied in urban area by municipalities, which may be attributed higher chances of contamination in urban area due to mismanagement of solid and liquid wastes. The study highlights the need for regular bacteriological enumeration along with water quality in addition to setting up decentralised region specific improved treatment system.
Resumo:
When people drink water having a fluoride (F-) concentration >1-1.5 mg/L for a long period of time, various ailments that are collectively referred to as fluorosis occur. Based on the design of Thomas (http://www.planetkerala.org), an inclined basin-type solar still containing sand and water has been used at Bangalore for defluoridation. For water samples having a fluoride concentration in the range 5-20 mg/L, the fluoride concentration in the distillate was usually <1.5 mg/L. During the periods October 2006 May 2007 and October 2007 May 2008, the volume of distillate showed a significant diurnal variation, ranging from 0.3 to 4.0 L/m(2).day. Based on the figures for 2006, the cost of the still was about Rs. 850 (US$16) for collector areas in the range 0.50-0.57 m(2). The occurrence of F- in the distillate merits further investigation. Overall, the still effectively removes F-, but a large area of the collector, in the range 2.5-25 m(2), is needed to produce about 10 L of distilled water for cooking and drinking. Rainwater falling on the upper surface of the still was collected, and its fluoride concentration was found to be below the desirable limit of 1 mg/L. Hence it can also be used for cooking and drinking.
Resumo:
Riboflavin tetraacetate-catalyzed aerobic photooxidation of 1-(4-methoxyphenyl)ethanol was investigated as a model reaction under blue visible light in different soft gel materials, aiming to establish their potential as reaction vessels for photochemical transformations. Three strategies involving different degrees of organization of the catalyst within the gel network were explored, and the results compared to those obtained in homogeneous and micellar solutions. In general, physical entrapment of both the catalyst and the substrate under optimized concentrations into several hydrogel matrices (including low-molecular-weight and biopolymer-based gels) allowed the photooxidation with conversions between 55 and 100% within 120 min (TOF similar to 0.045-0.08 min(-1); k(obs) similar to 0.011-0.028 min(-1)), albeit with first-order rates ca. 1-3-fold lower than in solution under comparable non-stirred conditions. Remarkably, the organogel made of a cyclohexane-based bisamide gelator in CH3CN not only prevented the photodegradation of the catalyst but also afforded full conversion in less than 60 min (TOF similar to 0.167 min(-1); k(obs) similar to 0.073 min(-1)) without the need of additional proton transfer mediators (e. g., thiourea) as it occurs in CH3CN solutions. In general, the gelators could be recycled without detriment to their gelation ability and reaction rates. Moreover, kinetics could be fine-tuned according to the characteristics of the gel media. For instance, entangled fibrillar networks with relatively high mechanical strength were usually associated with lower reaction rates, whereas wrinkled laminated morphologies seemed to favor the reaction. In addition, the kinetics results showed in most cases a good correlation with the aeration efficiency of the gel media.
Resumo:
A network of ship-mounted real-time Automatic Weather Stations integrated with Indian geosynchronous satellites Indian National Satellites (INSATs)] 3A and 3C, named Indian National Centre for Ocean Information Services Real-Time Automatic Weather Stations (I-RAWS), is established. The purpose of I-RAWS is to measure the surface meteorological-ocean parameters and transmit the data in real time in order to validate and refine the forcing parameters (obtained from different meteorological agencies) of the Indian Ocean Forecasting System (INDOFOS). Preliminary validation and intercomparison of analyzed products obtained from the National Centre for Medium Range Weather Forecasting and the European Centre for Medium-Range Weather Forecasts using the data collected from I-RAWS were carried out. This I-RAWS was mounted on board oceanographic research vessel Sagar Nidhi during a cruise across three oceanic regimes, namely, the tropical Indian Ocean, the extratropical Indian Ocean, and the Southern Ocean. The results obtained from such a validation and intercomparison, and its implications with special reference to the usage of atmospheric model data for forcing ocean model, are discussed in detail. It is noticed that the performance of analysis products from both atmospheric models is similar and good; however, European Centre for Medium-Range Weather Forecasts air temperature over the extratropical Indian Ocean and wind speed in the Southern Ocean are marginally better.
Resumo:
A porous carbon foam (CF) electrode modified with a reduced graphene oxide-Ag (rGO-Ag) nanocomposite has been fabricated to purify water. It can perform as an antibacterial device by killing pathogenic microbes with the aid of a 1.5 V battery, with very little power consumption. The device is recycled ten times with good performance for long term usage. It is shown that the device may be implemented as a fast water purifier to deactivate the pathogens in drinking water.