819 resultados para Donation after Cardiac Death
Resumo:
BACKGROUND Diabetes mellitus and angiographic coronary artery disease complexity are intertwined and unfavorably affect prognosis after percutaneous coronary interventions, but their relative impact on long-term outcomes after percutaneous coronary intervention with drug-eluting stents remains controversial. This study determined drug-eluting stents outcomes in relation to diabetic status and coronary artery disease complexity as assessed by the Synergy Between PCI With Taxus and Cardiac Surgery (SYNTAX) score. METHODS AND RESULTS In a patient-level pooled analysis from 4 all-comers trials, 6081 patients were stratified according to diabetic status and according to the median SYNTAX score ≤11 or >11. The primary end point was major adverse cardiac events, a composite of cardiac death, myocardial infarction, and clinically indicated target lesion revascularization within 2 years. Diabetes mellitus was present in 1310 patients (22%), and new-generation drug-eluting stents were used in 4554 patients (75%). Major adverse cardiac events occurred in 173 diabetics (14.5%) and 436 nondiabetic patients (9.9%; P<0.001). In adjusted Cox regression analyses, SYNTAX score and diabetes mellitus were both associated with the primary end point (P<0.001 and P=0.028, respectively; P for interaction, 0.07). In multivariable analyses, diabetic versus nondiabetic patients had higher risks of major adverse cardiac events (hazard ratio, 1.25; 95% confidence interval, 1.03-1.53; P=0.026) and target lesion revascularization (hazard ratio, 1.54; 95% confidence interval, 1.18-2.01; P=0.002) but similar risks of cardiac death (hazard ratio, 1.41; 95% confidence interval, 0.96-2.07; P=0.08) and myocardial infarction (hazard ratio, 0.89; 95% confidence interval, 0.64-1.22; P=0.45), without significant interaction with SYNTAX score ≤11 or >11 for any of the end points. CONCLUSIONS In this population treated with predominantly new-generation drug-eluting stents, diabetic patients were at increased risk for repeat target-lesion revascularization consistently across the spectrum of disease complexity. The SYNTAX score was an independent predictor of 2-year outcomes but did not modify the respective effect of diabetes mellitus. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifiers: NCT00297661, NCT00389220, NCT00617084, and NCT01443104.
Resumo:
THE AIM OF THE STUDY There are limited data on blood pressure targets and vasopressor use following cardiac arrest. We hypothesized that hypotension and high vasopressor load are associated with poor neurological outcome following out-of-hospital cardiac arrest (OHCA). METHODS We included 412 patients with OHCA included in FINNRESUSCI study conducted between 2010 and 2011. Hemodynamic data and vasopressor doses were collected electronically in one, two or five minute intervals. We evaluated thresholds for time-weighted (TW) mean arterial pressure (MAP) and outcome by receiver operating characteristic (ROC) curve analysis, and used multivariable analysis adjusting for co-morbidities, factors at resuscitation, an illness severity score, TW MAP and total vasopressor load (VL) to test associations with one-year neurologic outcome, dichotomized into either good (1-2) or poor (3-5) according to the cerebral performance category scale. RESULTS Of 412 patients, 169 patients had good and 243 patients had poor one-year outcomes. The lowest MAP during the first six hours was 58 (inter-quartile range [IQR] 56-61) mmHg in those with a poor outcome and 61 (59-63) mmHg in those with a good outcome (p<0.01), and lowest MAP was independently associated with poor outcome (OR 1.02 per mmHg, 95% CI 1.00-1.04, p=0.03). During the first 48h the median (IQR) of the TW mean MAP was 80 (78-82) mmHg in patients with poor, and 82 (81-83) mmHg in those with good outcomes (p=0.03) but in multivariable analysis TWA MAP was not associated with outcome. Vasopressor load did not predict one-year neurologic outcome. CONCLUSIONS Hypotension occurring during the first six hours after cardiac arrest is an independent predictor of poor one-year neurologic outcome. High vasopressor load was not associated with poor outcome and further randomized trials are needed to define optimal MAP targets in OHCA patients.
Resumo:
Background: The Lescol Intervention Prevention Study (LIPS) was a multinational randomized controlled trial that showed a 47% reduction in the relative risk of cardiac death and a 22% reduction in major adverse cardiac events (MACEs) from the routine use of fluvastatin, compared with controls, in patients undergoing percutaneous coronary intervention (PCI, defined as angioplasty with or without stents). In this study, MACEs included cardiac death, nonfatal myocardial infarction, and subsequent PCI and coronary artery bypass graft. Diabetes was the greatest risk factor for MACEs. Objective: This study estimated the cost-effectiveness of fluvastatin when used for secondary prevention of MACEs after PCI in people with diabetes. Methods: A post hoc subgroup analysis of patients with diabetes from the LIPS was used to estimate the effectiveness of fluvastatin in reducing myocardial infarction, revascularization, and cardiac death. A probabilistic Markov model was developed using United Kingdom resource and cost data to estimate the additional costs and quality-adjusted life-years (QALYs) gained over 10 years from the perspective of the British National Health Service. The model contained 6 health states, and the transition probabilities were derived from the LIPS data. Crossover from fluvastatin to other lipid-lowering drugs, withdrawal from fluvastatin, and the use of lipid-lowering drugs in the control group were included. Results: In the subgroup of 202 patients with diabetes in the LIPS trial, 18 (15.0%) of 120 fluvastatin patients and 21 (25.6%) of 82 control participants were insulin dependent (P = NS). Compared with the control group, patients treated with fluvastatin can expect to gain an additional mean (SD) of 0.196 (0.139) QALY per patient over 10 years (P < 0.001) and will cost the health service an additional mean (SD) of 10 (E448) (P = NS) (mean [SD] US $16 [$689]). The additional cost per QALY gained was;(51 (US $78). The key determinants of cost-effectiveness included the probabilities of repeat interventions, cardiac death, the cost of fluvastatin, and the time horizon used for the evaluation. Conclusion: Fluvastatin was an economically efficient treatment to prevent MACEs in these patients with diabetes undergoing PCI.
Resumo:
Thesis (Ph.D.)--University of Washington, 2016-07
Resumo:
We explored common beliefs and preferences for posthumous and living organ donation in Australia where organ donation rates are low and little research exists. Content analysis of discussions revealed the advantage of prolonging/saving life whereas disadvantages differed according to donation context. A range of people/groups perceived to approve and disapprove of donation were identified. Barriers for posthumous donation included a family’s objection, with the type of organ needed important for living donation. Motivators included knowledge about potential organ recipients. Donation preferences favored loved ones, with weaker preferences for recipients who were perceived as morally questionable or responsible for their illness.
Resumo:
The high morbidity and mortality associated with atherosclerotic coronary vascular disease (CVD) and its complications are being lessened by the increased knowledge of risk factors, effective preventative measures and proven therapeutic interventions. However, significant CVD morbidity remains and sudden cardiac death continues to be a presenting feature for some subsequently diagnosed with CVD. Coronary vascular disease is also the leading cause of anaesthesia related complications. Stress electrocardiography/exercise testing is predictive of 10 year risk of CVD events and the cardiovascular variables used to score this test are monitored peri-operatively. Similar physiological time-series datasets are being subjected to data mining methods for the prediction of medical diagnoses and outcomes. This study aims to find predictors of CVD using anaesthesia time-series data and patient risk factor data. Several pre-processing and predictive data mining methods are applied to this data. Physiological time-series data related to anaesthetic procedures are subjected to pre-processing methods for removal of outliers, calculation of moving averages as well as data summarisation and data abstraction methods. Feature selection methods of both wrapper and filter types are applied to derived physiological time-series variable sets alone and to the same variables combined with risk factor variables. The ability of these methods to identify subsets of highly correlated but non-redundant variables is assessed. The major dataset is derived from the entire anaesthesia population and subsets of this population are considered to be at increased anaesthesia risk based on their need for more intensive monitoring (invasive haemodynamic monitoring and additional ECG leads). Because of the unbalanced class distribution in the data, majority class under-sampling and Kappa statistic together with misclassification rate and area under the ROC curve (AUC) are used for evaluation of models generated using different prediction algorithms. The performance based on models derived from feature reduced datasets reveal the filter method, Cfs subset evaluation, to be most consistently effective although Consistency derived subsets tended to slightly increased accuracy but markedly increased complexity. The use of misclassification rate (MR) for model performance evaluation is influenced by class distribution. This could be eliminated by consideration of the AUC or Kappa statistic as well by evaluation of subsets with under-sampled majority class. The noise and outlier removal pre-processing methods produced models with MR ranging from 10.69 to 12.62 with the lowest value being for data from which both outliers and noise were removed (MR 10.69). For the raw time-series dataset, MR is 12.34. Feature selection results in reduction in MR to 9.8 to 10.16 with time segmented summary data (dataset F) MR being 9.8 and raw time-series summary data (dataset A) being 9.92. However, for all time-series only based datasets, the complexity is high. For most pre-processing methods, Cfs could identify a subset of correlated and non-redundant variables from the time-series alone datasets but models derived from these subsets are of one leaf only. MR values are consistent with class distribution in the subset folds evaluated in the n-cross validation method. For models based on Cfs selected time-series derived and risk factor (RF) variables, the MR ranges from 8.83 to 10.36 with dataset RF_A (raw time-series data and RF) being 8.85 and dataset RF_F (time segmented time-series variables and RF) being 9.09. The models based on counts of outliers and counts of data points outside normal range (Dataset RF_E) and derived variables based on time series transformed using Symbolic Aggregate Approximation (SAX) with associated time-series pattern cluster membership (Dataset RF_ G) perform the least well with MR of 10.25 and 10.36 respectively. For coronary vascular disease prediction, nearest neighbour (NNge) and the support vector machine based method, SMO, have the highest MR of 10.1 and 10.28 while logistic regression (LR) and the decision tree (DT) method, J48, have MR of 8.85 and 9.0 respectively. DT rules are most comprehensible and clinically relevant. The predictive accuracy increase achieved by addition of risk factor variables to time-series variable based models is significant. The addition of time-series derived variables to models based on risk factor variables alone is associated with a trend to improved performance. Data mining of feature reduced, anaesthesia time-series variables together with risk factor variables can produce compact and moderately accurate models able to predict coronary vascular disease. Decision tree analysis of time-series data combined with risk factor variables yields rules which are more accurate than models based on time-series data alone. The limited additional value provided by electrocardiographic variables when compared to use of risk factors alone is similar to recent suggestions that exercise electrocardiography (exECG) under standardised conditions has limited additional diagnostic value over risk factor analysis and symptom pattern. The effect of the pre-processing used in this study had limited effect when time-series variables and risk factor variables are used as model input. In the absence of risk factor input, the use of time-series variables after outlier removal and time series variables based on physiological variable values’ being outside the accepted normal range is associated with some improvement in model performance.
Resumo:
The theory of nonlinear dyamic systems provides some new methods to handle complex systems. Chaos theory offers new concepts, algorithms and methods for processing, enhancing and analyzing the measured signals. In recent years, researchers are applying the concepts from this theory to bio-signal analysis. In this work, the complex dynamics of the bio-signals such as electrocardiogram (ECG) and electroencephalogram (EEG) are analyzed using the tools of nonlinear systems theory. In the modern industrialized countries every year several hundred thousands of people die due to sudden cardiac death. The Electrocardiogram (ECG) is an important biosignal representing the sum total of millions of cardiac cell depolarization potentials. It contains important insight into the state of health and nature of the disease afflicting the heart. Heart rate variability (HRV) refers to the regulation of the sinoatrial node, the natural pacemaker of the heart by the sympathetic and parasympathetic branches of the autonomic nervous system. Heart rate variability analysis is an important tool to observe the heart's ability to respond to normal regulatory impulses that affect its rhythm. A computerbased intelligent system for analysis of cardiac states is very useful in diagnostics and disease management. Like many bio-signals, HRV signals are non-linear in nature. Higher order spectral analysis (HOS) is known to be a good tool for the analysis of non-linear systems and provides good noise immunity. In this work, we studied the HOS of the HRV signals of normal heartbeat and four classes of arrhythmia. This thesis presents some general characteristics for each of these classes of HRV signals in the bispectrum and bicoherence plots. Several features were extracted from the HOS and subjected an Analysis of Variance (ANOVA) test. The results are very promising for cardiac arrhythmia classification with a number of features yielding a p-value < 0.02 in the ANOVA test. An automated intelligent system for the identification of cardiac health is very useful in healthcare technology. In this work, seven features were extracted from the heart rate signals using HOS and fed to a support vector machine (SVM) for classification. The performance evaluation protocol in this thesis uses 330 subjects consisting of five different kinds of cardiac disease conditions. The classifier achieved a sensitivity of 90% and a specificity of 89%. This system is ready to run on larger data sets. In EEG analysis, the search for hidden information for identification of seizures has a long history. Epilepsy is a pathological condition characterized by spontaneous and unforeseeable occurrence of seizures, during which the perception or behavior of patients is disturbed. An automatic early detection of the seizure onsets would help the patients and observers to take appropriate precautions. Various methods have been proposed to predict the onset of seizures based on EEG recordings. The use of nonlinear features motivated by the higher order spectra (HOS) has been reported to be a promising approach to differentiate between normal, background (pre-ictal) and epileptic EEG signals. In this work, these features are used to train both a Gaussian mixture model (GMM) classifier and a Support Vector Machine (SVM) classifier. Results show that the classifiers were able to achieve 93.11% and 92.67% classification accuracy, respectively, with selected HOS based features. About 2 hours of EEG recordings from 10 patients were used in this study. This thesis introduces unique bispectrum and bicoherence plots for various cardiac conditions and for normal, background and epileptic EEG signals. These plots reveal distinct patterns. The patterns are useful for visual interpretation by those without a deep understanding of spectral analysis such as medical practitioners. It includes original contributions in extracting features from HRV and EEG signals using HOS and entropy, in analyzing the statistical properties of such features on real data and in automated classification using these features with GMM and SVM classifiers.
Resumo:
Within the cardiac high dependency unit it is currently a member of the surgical team who makes the decision for a patient's chest drain to be removed after cardiac surgery. This has often resulted in delays in discharging one patient and therefore in admitting the next. A pilot study was carried out using a working standard that had been developed, incorporating an algorithmic model. The results have enabled nursing staff in a cardiac high dependency unit to undertake this responsibility independently.
Resumo:
Background: Patients may need massive volume-replacement therapy after cardiac surgery because of large fluid transfer perioperatively, and the use of cardiopulmonary bypass. Hemodynamic stability is better maintained with colloids than crystalloids but colloids have more adverse effects such as coagulation disturbances and impairment of renal function than do crystalloids. The present study examined the effects of modern hydroxyethyl starch (HES) and gelatin solutions on blood coagulation and hemodynamics. The mechanism by which colloids disturb blood coagulation was investigated by thromboelastometry (TEM) after cardiac surgery and in vitro by use of experimental hemodilution. Materials and methods: Ninety patients scheduled for elective primary cardiac surgery (Studies I, II, IV, V), and twelve healthy volunteers (Study III) were included in this study. After admission to the cardiac surgical intensive care unit (ICU), patients were randomized to receive different doses of HES 130/0.4, HES 200/0.5, or 4% albumin solutions. Ringer’s acetate or albumin solutions served as controls. Coagulation was assessed by TEM, and hemodynamic measurements were based on thermodilutionally measured cardiac index (CI). Results: HES and gelatin solutions impaired whole blood coagulation similarly as measured by TEM even at a small dose of 7 mL/kg. These solutions reduced clot strength and prolonged clot formation time. These effects were more pronounced with increasing doses of colloids. Neither albumin nor Ringer’s acetate solution disturbed blood coagulation significantly. Coagulation disturbances after infusion of HES or gelatin solutions were clinically slight, and postoperative blood loss was comparable with that of Ringer’s acetate or albumin solutions. Both single and multiple doses of all the colloids increased CI postoperatively, and this effect was dose-dependent. Ringer’s acetate had no effect on CI. At a small dose (7 mL/kg), the effect of gelatin on CI was comparable with that of Ringer’s acetate and significantly less than that of HES 130/0.4 (Study V). However, when the dose was increased to 14 and 21 mL/kg, the hemodynamic effect of gelatin rose and became comparable with that of HES 130/0.4. Conclusions: After cardiac surgery, HES and gelatin solutions impaired clot strength in a dose-dependent manner. The potential mechanisms were interaction with fibrinogen and fibrin formation, resulting in decreased clot strength, and hemodilution. Although the use of HES and gelatin inhibited coagulation, postoperative bleeding on the first postoperative morning in all the study groups was similar. A single dose of HES solutions improved CI postoperatively more than did gelatin, albumin, or Ringer’s acetate. However, when administered in a repeated fashion, (cumulative dose of 14 mL/kg or more), no differences were evident between HES 130/0.4 and gelatin.
Resumo:
The adequacy of anesthesia has been studied since the introduction of balanced general anesthesia. Commercial monitors based on electroencephalographic (EEG) signal analysis have been available for monitoring the hypnotic component of anesthesia from the beginning of the 1990s. Monitors measuring the depth of anesthesia assess the cortical function of the brain, and have gained acceptance during surgical anesthesia with most of the anesthetic agents used. However, due to frequent artifacts, they are considered unsuitable for monitoring consciousness in intensive care patients. The assessment of analgesia is one of the cornerstones of general anesthesia. Prolonged surgical stress may lead to increased morbidity and delayed postoperative recovery. However, no validated monitoring method is currently available for evaluating analgesia during general anesthesia. Awareness during anesthesia is caused by an inadequate level of hypnosis. This rare but severe complication of general anesthesia may lead to marked emotional stress and possibly posttraumatic stress disorder. In the present series of studies, the incidence of awareness and recall during outpatient anesthesia was evaluated and compared with that of in inpatient anesthesia. A total of 1500 outpatients and 2343 inpatients underwent a structured interview. Clear intraoperative recollections were rare the incidence being 0.07% in outpatients and 0.13% in inpatients. No significant differences emerged between outpatients and inpatients. However, significantly smaller doses of sevoflurane were administered to outpatients with awareness than those without recollections (p<0.05). EEG artifacts in 16 brain-dead organ donors were evaluated during organ harvest surgery in a prospective, open, nonselective study. The source of the frontotemporal biosignals in brain-dead subjects was studied, and the resistance of bispectral index (BIS) and Entropy to the signal artifacts was compared. The hypothesis was that in brain-dead subjects, most of the biosignals recorded from the forehead would consist of artifacts. The original EEG was recorded and State Entropy (SE), Response Entropy (RE), and BIS were calculated and monitored during solid organ harvest. SE differed from zero (inactive EEG) in 28%, RE in 29%, and BIS in 68% of the total recording time (p<0.0001 for all). The median values during the operation were SE 0.0, RE 0.0, and BIS 3.0. In four of the 16 organ donors, EEG was not inactive, and unphysiologically distributed, nonreactive rhythmic theta activity was present in the original EEG signal. After the results from subjects with persistent residual EEG activity were excluded, SE, RE, and BIS differed from zero in 17%, 18%, and 62% of the recorded time, respectively (p<0.0001 for all). Due to various artifacts, the highest readings in all indices were recorded without neuromuscular blockade. The main sources of artifacts were electrocauterization, electromyography (EMG), 50-Hz artifact, handling of the donor, ballistocardiography, and electrocardiography. In a prospective, randomized study of 26 patients, the ability of Surgical Stress Index (SSI) to differentiate patients with two clinically different analgesic levels during shoulder surgery was evaluated. SSI values were lower in patients with an interscalene brachial plexus block than in patients without an additional plexus block. In all patients, anesthesia was maintained with desflurane, the concentration of which was targeted to maintain SE at 50. Increased blood pressure or heart rate (HR), movement, and coughing were considered signs of intraoperative nociception and treated with alfentanil. Photoplethysmographic waveforms were collected from the contralateral arm to the operated side, and SSI was calculated offline. Two minutes after skin incision, SSI was not increased in the brachial plexus block group and was lower (38 ± 13) than in the control group (58 ± 13, p<0.005). Among the controls, one minute prior to alfentanil administration, SSI value was higher than during periods of adequate antinociception, 59 ± 11 vs. 39 ± 12 (p<0.01). The total cumulative need for alfentanil was higher in controls (2.7 ± 1.2 mg) than in the brachial plexus block group (1.6 ± 0.5 mg, p=0.008). Tetanic stimulation to the ulnar region of the hand increased SSI significantly only among patients with a brachial plexus block not covering the site of stimulation. Prognostic value of EEG-derived indices was evaluated and compared with Transcranial Doppler Ultrasonography (TCD), serum neuron-specific enolase (NSE) and S-100B after cardiac arrest. Thirty patients resuscitated from out-of-hospital arrest and treated with induced mild hypothermia for 24 h were included. Original EEG signal was recorded, and burst suppression ratio (BSR), RE, SE, and wavelet subband entropy (WSE) were calculated. Neurological outcome during the six-month period after arrest was assessed with the Glasgow-Pittsburgh Cerebral Performance Categories (CPC). Twenty patients had a CPC of 1-2, one patient had a CPC of 3, and nine patients died (CPC 5). BSR, RE, and SE differed between good (CPC 1-2) and poor (CPC 3-5) outcome groups (p=0.011, p=0.011, p=0.008, respectively) during the first 24 h after arrest. WSE was borderline higher in the good outcome group between 24 and 48 h after arrest (p=0.050). All patients with status epilepticus died, and their WSE values were lower (p=0.022). S-100B was lower in the good outcome group upon arrival at the intensive care unit (p=0.010). After hypothermia treatment, NSE and S-100B values were lower (p=0.002 for both) in the good outcome group. The pulsatile index was also lower in the good outcome group (p=0.004). In conclusion, the incidence of awareness in outpatient anesthesia did not differ from that in inpatient anesthesia. Outpatients are not at increased risk for intraoperative awareness relative to inpatients undergoing general anesthesia. SE, RE, and BIS showed non-zero values that normally indicate cortical neuronal function, but were in these subjects mostly due to artifacts after clinical brain death diagnosis. Entropy was more resistant to artifacts than BIS. During general anesthesia and surgery, SSI values were lower in patients with interscalene brachial plexus block covering the sites of nociceptive stimuli. In detecting nociceptive stimuli, SSI performed better than HR, blood pressure, or RE. BSR, RE, and SE differed between the good and poor neurological outcome groups during the first 24 h after cardiac arrest, and they may be an aid in differentiating patients with good neurological outcomes from those with poor outcomes after out-of-hospital cardiac arrest.
Resumo:
Background. the skin neurogenic inflammation is mainly related to Substance P (SP) and Calcitonin Gene-related Peptide (CGRP). There is no data on their availability in the dynamics of skin nerve endings, concerning their release and replenishment after a nociceptive stimulus, so this was investigated. Materials and methods. 25 rats were randomly distributed in 5 groups. the animals of the control group (CG) determined the baseline levels of neuropeptides in the skin. the groups S0 and S30 did not receive any cutaneous stimulus at 30 and 60 minutes, respectively. in the group S1, an incision stimulus was made at 30 minutes. in the group S31, a nociceptive stimulus was performed by subdermal scratching at 30 minutes and, at 60 minutes, the incision stimulus was carried out in the same location (nociceptive hyperstimulation). the skin samples of the other animals were harvested from the back 1 minute after their death. SP, pro-CGRP and CGRP were quantified by Western Blotting. Results. the incision stimulus released SP, S1 compared to S0 (p < 0.05) detected in the first minute, and the replenishment time was more than 30 minutes. Also, it cleaved pro-CGRP, S1 compared to S31 (p < 0.05) in the first minute, and its replenishment time less than 30 minutes. Release of CGRP was not detected. Conclusion. the incision released SP already detected in the first minute; its replenishment time is more than 30 minutes. the incision decreased pro-CGRP, also detected in the first minute; and its replenishment time is less than 30 minutes.
Resumo:
Printed pamphlet of sermons presented by ministers and pastors after the death of President James A. Garfield.
Resumo:
We study the exact entanglement dynamics of two qubits in a common structured reservoir. We demonstrate that for certain classes of entangled states, entanglement sudden death occurs, while for certain initially factorized states, entanglement sudden birth takes place. The backaction of the non-Markovian reservoir is responsible for revivals of entanglement after sudden death has occurred, and also for periods of disentanglement following entanglement sudden birth.
Resumo:
Objectives. We compared the mental health risk to unpaid caregivers bereaved of a care recipient with the risk to persons otherwise bereaved and to nonbereaved caregivers.
Methods. We linked prescription records for antidepressant and anxiolytic drugs to characteristics and life-event data of members of the Northern Ireland Longitudinal Study (n = 317 264). Using a case-control design, we fitted logistic regression models, stratified by age, to model relative likelihood of mental health problems, using the proxy measures of mental health–related prescription.
Results. Both caregivers and bereaved individuals were estimated to be at between 20% and 50% greater risk for mental health problems than noncaregivers in similar circumstances (for bereaved working-age caregivers, odds ratio = 1.41; 95% confidence interval = 1.27, 1.56). For older people, there was no evidence of additional risk to bereaved caregivers, though there was for working-age people. Older people appeared to recover more quickly from caregiver bereavement.
Conclusions. Caregivers were at risk for mental ill health while providing care and after the death of the care recipient. Targeted caregiver support needs to extend beyond the life of the care recipient.
Resumo:
INTRODUCTION: Hypoplastic left heart syndrome (HLHS) is a major cause of cardiac death during the first week of life. The hybrid approach is a reliable, reproducible treatment option for patients with HLHS. Herein we report our results using this approach, focusing on its efficacy, safety and late outcome. METHODS: We reviewed prospectively collected data on patients treated for HLHS using a hybrid approach between July 2007 and September 2014. RESULTS: Nine patients had a stage 1 hybrid procedure, with seven undergoing a comprehensive stage 2 procedure. One patient completed the Fontan procedure. Five patients underwent balloon atrial septostomy after the hybrid procedure; in three patients, a stent was placed across the atrial septum. There were three deaths: two early after the hybrid procedure and one early after stage two palliation. Overall survival was 66%. CONCLUSIONS: In our single-center series, the hybrid approach for HLHS yields intermediate results comparable to those of the Norwood strategy. The existence of dedicated teams for the diagnosis and management of these patients, preferably in high-volume centers, is of major importance in this condition.