964 resultados para DISTRIBUTED BRAGG REFLECTORS


Relevância:

80.00% 80.00%

Publicador:

Resumo:

As human populations and resource consumption increase, it is increasingly important to monitor the quality of our environment. While laboratory instruments offer useful information, portable, easy to use sensors would allow environmental analysis to occur on-site, at lower cost, and with minimal operator training. We explore the synthesis, modification, and applications of modified polysiloxane in environmental sensing. Multiple methods of producing modified siloxanes were investigated. Oligomers were formed by using functionalized monomers, producing siloxane materials containing silicon hydride, methyl, and phenyl side chains. Silicon hydride-functionalized oligomers were further modified by hydrosilylation to incorporate methyl ester and naphthyl side chains. Modifications to the siloxane materials were also carried out using post-curing treatments. Methyl ester-functionalized siloxane was incorporated into the surface of a cured poly(dimethylsiloxane) film by siloxane equilibration. The materials containing methyl esters were hydrolyzed to reveal carboxylic acids, which could later be used for covalent protein immobilization. Finally, the siloxane surfaces were modified to incorporate antibodies by covalent, affinity, and adsorption-based attachment. These modifications were characterized by a variety of methods, including contact angle, attenuated total reflectance Fourier transform infrared spectroscopy, dye labels, and 1H nuclear magnetic resonance spectroscopy. The modified siloxane materials were employed in a variety of sensing schemes. Volatile organic compounds were detected using methyl, phenyl, and naphthyl-functionalized materials on a Fabry-Perot interferometer and a refractometer. The Fabry-Perot interferometer was found to detect the analytes upon siloxane extraction by deformation of the Bragg reflectors. The refractometer was used to determine that naphthyl-functionalized siloxanes had elevated refractive indices, rendering these materials more sensitive to some analytes. Antibody-modified siloxanes were used to detect biological analytes through a solid phase microextraction-mediated enzyme linked immunosorbent assay (SPME ELISA). The SPME ELISA was found to have higher analyte sensitivity compared to a conventional ELISA system. The detection scheme was used to detect Escherichia coli at 8500 CFU/mL. These results demonstrate the variety of methods that can be used to modify siloxanes and the wide range of applications of modified siloxanes has been demonstrated through chemical and biological sensing schemes.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A fully distributed temperature sensor consisting of a chirped fibre Bragg grating has been demonstrated. By fitting a numerical model of the grating response including temperature change, position and width of localized heating applied to the grating, we achieve measurements of these parameters to within 2.2 K, 149 µm and 306 µm of applied values, respectively. Assuming that deviation from linearity is accounted for in making measurement, much higher precision is achievable and the standard deviations for these measurements are 0.6 K, 28.5 µm and 56.0 µm, respectively.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A fully distributed temperature sensor consisting of a chirped fibre Bragg grating has been demonstrated. By fitting a numerical model of the grating response including temperature change, position and width of localized heating applied to the grating, we achieve measurements of these parameters to within 2.2 K, 149 μm and 306 μm of applied values, respectively. Assuming that deviation from linearity is accounted for in making measurement, much higher precision is achievable and the standard deviations for these measurements are 0.6 K, 28.5 μm and 56.0 μm, respectively. © 2004 IOP Publishing Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A chirped moiré fiber Bragg grating has been demonstrated to be capable of measuring the magnitude, position, and footprint of a transverse load. The device provides an average spatial resolution of 164 μm and has a load accuracy of 0.15 N/mm, or 50 με. © 2004 Optical Society of America.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A quasi-distributed strain sensor with an average spatial resolution of 164 µm over a length of 25 mm and a strain sensitivity of 0.8 ± 0.01 pm/µe has been experimentally demonstrated. The sensor was formed by a chirped Moiré fiber Bragg grating written into the core of single-mode optical fiber with a 244-nm continuous-wave laser. © 2005 IEEE.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A distributed temperature sensor is presented which uses a chirped Moiré fibre Bragg grating to give a thermal resolution of 0.2 °C with a spatial resolution of 164 μm. The wavelength sensitivity of the device is 0.01 ± 4 × 10−4 nm/°C. Such a sensor has biomedical and industrial applications where accurate measurement of location and intensity of temperature is essential. The sensor may be used as a one- or two-dimensional temperature monitor, depending on the configuration.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A distributed temperature sensor is presented which uses a chirped Moiré fibre Bragg grating to give a thermal resolution of 0.2°C with a spatial resolution of 164 μm. The wavelength sensitivity of the device is 0.01 ± 4 × 10-4 nm/°C. Such a sensor has biomedical and industrial applications where accurate measurement of location and intensity of temperature is essential. The sensor may be used as a one- or two-dimensional temperature monitor, depending on the configuration. © 2004 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We experimentally demonstrate a Raman fiber laser based on multiple point-action fiber Bragg grating reflectors and distributed feedback via Rayleigh scattering in an ∼22-km-long optical fiber. Twenty-two lasing lines with spacing of ∼100 GHz (close to International Telecommunication Union grid) in the C band are generated at the watt level. In contrast to the normal cavity with competition between laser lines, the random distributed feedback cavity exhibits highly stable multiwavelength generation with a power-equalized uniform distribution, which is almost independent on power. © 2011 Optical Society of America.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We experimentally demonstrate a Raman fiber laser based on multiple point-action fiber Bragg grating (FBG) reflectors and distributed feedback via Rayleigh scattering in a ∼22 km long optical fiber. Twenty two lasing lines with spacing of ∼100 GHz (close to ITU grid) in C-band are generated at Watts power level. In contrast to the normal cavity with competition between laser lines, the random distributed feedback cavity exhibits highly stable multiwavelength generation with a power-equalized uniform distribution which is almost independent on power. The current set up showing the capability of generating Raman gain of about 100-nm wide giving the possibility of multiwavelength generation at different bands. © 2011 SPIE.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A novel interrogation technique for fully distributed linearly chirped fiber Bragg grating (LCFBG) strain sensors with simultaneous high temporal and spatial resolution based on optical time-stretch frequency-domain reflectometry (OTS-FDR) is proposed and experimentally demonstrated. LCFBGs is a promising candidate for fully distributed sensors thanks to its longer grating length and broader reflection bandwidth compared to normal uniform FBGs. In the proposed system, two identical LCFBGs are employed in a Michelson interferometer setup with one grating serving as the reference grating whereas the other serving as the sensing element. Broadband spectral interferogram is formed and the strain information is encoded into the wavelength-dependent free spectral range (FSR). Ultrafast interrogation is achieved based on dispersion-induced time stretch such that the target spectral interferogram is mapped to a temporal interference waveform that can be captured in real-Time using a single-pixel photodector. The distributed strain along the sensing grating can be reconstructed from the instantaneous RF frequency of the captured waveform. High-spatial resolution is also obtained due to high-speed data acquisition. In a proof-of-concept experiment, ultrafast real-Time interrogation of fully-distributed grating sensors with various strain distributions is experimentally demonstrated. An ultrarapid measurement speed of 50 MHz with a high spatial resolution of 31.5 μm over a gauge length of 25 mm and a strain resolution of 9.1 μϵ have been achieved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As a novel sensitive element and due to its advantages of immunity to electrical interference, distributed measurement, etc., fiber Bragg grating (FBG) has been researched widely. To realize the substitution of high accurate electronic temperature sensors, high sensitive FBG temperature sensors can be made by taking advantage of its characters of being sensitive to both temperature and strain. Although there are reports about high sensitive FBG temperature sensors, however, few about their stability have been done. We manufactured a high sensitive FBG temperature sensor, and put it together with an average FBG temperature sensor and an electronic crystal temperature sensor into a stainless steel container filled by water to observe the room temperature change. By comparing their results in two weeks, we have found out that: although the high sensitive FBG temperature sensor is in much better agreement with the electronic crystal sensor than the average FBG sensor is, it has occurred some small drifts. Because the drifts appeared in the process of further pulling the FBG, it might be a result of the slip of the FBG fixing points. This contributes some good experiences to the application of FBG in high accuracy temperature measurement.