989 resultados para DIAGNOSTIC USES
Resumo:
Existem referências aos manuais de bem confessar que os Jesuitas utilizaram na Índia desde os inícios da sua actividade missionária, mas até agora não se tinha publicado nenhum para os séculos XVI-XVII. Encontrei alguns na British Library em Londres em 1994, e estão aqui analisados, dando a conhecer como a nova religião ajudava a criar cidadãos responsáveis do império colonial e a cumprir as suas leis. Para além de ajudar-nos a compreender o vocabulário e o estilo da língua vernácula destes tempos, alguém que evitasse pagar impostos ao Estado ou manipulasse os livros de contas da aldeia encorria em pecados a confessar.
Resumo:
This study aimed to determine and evaluate the diagnostic accuracy of visual screening tests for detecting vision loss in elderly. This study is defined as study of diagnostic performance. The diagnostic accuracy of 5 visual tests -near convergence point, near accommodation point, stereopsis, contrast sensibility and amsler grid—was evaluated by means of the ROC method (receiver operating characteristics curves), sensitivity, specificity, positive and negative likelihood ratios (LR+/LR−). Visual acuity was used as the reference standard. A sample of 44 elderly aged 76.7 years (±9.32), who were institutionalized, was collected. The curves of contrast sensitivity and stereopsis are the most accurate (area under the curves were 0.814−p = 0.001, C.I.95%[0.653;0.975]— and 0.713−p = 0.027, C.I.95%[0,540;0,887], respectively). The scores with the best diagnostic validity for the stereopsis test were 0.605 (sensitivity 0.87, specificity 0.54; LR+ 1.89, LR−0.24) and 0.610 (sensitivity 0.81, specificity 0.54; LR+1.75, LR−0.36). The scores with higher diagnostic validity for the contrast sensibility test were 0.530 (sensitivity 0.94, specificity 0.69; LR+ 3.04, LR−0.09). The contrast sensitivity and stereopsis test's proved to be clinically useful in detecting vision loss in the elderly.
Resumo:
The aging of Portuguese population is characterized by an increase of individuals aged older than 65 years. Preventable visual loss in older persons is an important public health problem. Tests used for vision screening should have a high degree of diagnostic validity confirmed by means of clinical trials. The primary aim of a screening program is the early detection of visual diseases. Between 20% and 50% of older people in the UK have undetected reduced vision and in most cases is correctable. Elderly patients do not receive a systematic eye examination unless a problem arises with their glasses or suspicion vision loss. This study aimed to determine and evaluate the diagnostic accuracy of visual screening tests for detecting vision loss in elderly. Furthermore, it pretends to define the ability to find the subjects affected with vision loss as positive and the subjects not affected with the same disease as negative. The ideal vision screening method should have high sensitivity and specificity for early detection of risk factors. It should be also low cost and easy to implement in all geographic and socioeconomic regions. Sensitivity is the ability of an examination to identify the presence of a given disease and specificity is the ability of the examination to identify the absence of a given disease. It was not an aim of this study to detect abnormalities that affect visual acuity. The aim of this study was to find out what´s the best test for the identification of any vision loss.
Resumo:
Esta tese pretende contribuir para o estudo e análise dos factores relacionados com as técnicas de aquisição de imagens radiológicas digitais, a qualidade diagnóstica e a gestão da dose de radiação em sistema de radiologia digital. A metodologia encontra-se organizada em duas componentes. A componente observacional, baseada num desenho do estudo de natureza retrospectiva e transversal. Os dados recolhidos a partir de sistemas CR e DR permitiram a avaliação dos parâmetros técnicos de exposição utilizados em radiologia digital, a avaliação da dose absorvida e o índice de exposição no detector. No contexto desta classificação metodológica (retrospectiva e transversal), também foi possível desenvolver estudos da qualidade diagnóstica em sistemas digitais: estudos de observadores a partir de imagens arquivadas no sistema PACS. A componente experimental da tese baseou-se na realização de experiências em fantomas para avaliar a relação entre dose e qualidade de imagem. As experiências efectuadas permitiram caracterizar as propriedades físicas dos sistemas de radiologia digital, através da manipulação das variáveis relacionadas com os parâmetros de exposição e a avaliação da influência destas na dose e na qualidade da imagem. Utilizando um fantoma contraste de detalhe, fantomas antropomórficos e um fantoma de osso animal, foi possível objectivar medidas de quantificação da qualidade diagnóstica e medidas de detectabilidade de objectos. Da investigação efectuada, foi possível salientar algumas conclusões. As medidas quantitativas referentes à performance dos detectores são a base do processo de optimização, permitindo a medição e a determinação dos parâmetros físicos dos sistemas de radiologia digital. Os parâmetros de exposição utilizados na prática clínica mostram que a prática não está em conformidade com o referencial Europeu. Verifica-se a necessidade de avaliar, melhorar e implementar um padrão de referência para o processo de optimização, através de novos referenciais de boa prática ajustados aos sistemas digitais. Os parâmetros de exposição influenciam a dose no paciente, mas a percepção da qualidade de imagem digital não parece afectada com a variação da exposição. Os estudos que se realizaram envolvendo tanto imagens de fantomas como imagens de pacientes mostram que a sobreexposição é um risco potencial em radiologia digital. A avaliação da qualidade diagnóstica das imagens mostrou que com a variação da exposição não se observou degradação substancial da qualidade das imagens quando a redução de dose é efectuada. Propõe-se o estudo e a implementação de novos níveis de referência de diagnóstico ajustados aos sistemas de radiologia digital. Como contributo da tese, é proposto um modelo (STDI) para a optimização de sistemas de radiologia digital.
Resumo:
This chapter provides a theoretical background about image quality in diagnostic radiology. Digital image representation and also image quality evaluation methods are here discussed. An overview of methods for quality evaluation of diagnostic imaging procedures is provided. Digital image representation and primary physical image quality parameters are also discussed, including objective image quality measurements and observer performance methods.
Resumo:
OBJECTIVE: To evaluate the discriminative and diagnostic values of neuropsychological tests for identifying schizophrenia patients. METHODS: A cross-sectional study with 36 male schizophrenia outpatients and 72 healthy matched volunteers was carried out. Participants underwent the following neuropsychological tests: Wisconsin Card Sorting test, Verbal Fluency, Stroop test, Mini Mental State Examination, and Spatial Recognition Span. Sensitivity and specificity estimated the diagnostic value of tests with cutoffs obtained using Receiver Operating Characteristic curves. The latent class model (diagnosis of schizophrenia) was used as gold standard. RESULTS: Although patients presented lower scores in most tests, the highest canonical function for the discriminant analysis was 0.57 (Verbal Fluency M). The best sensitivity and specificity were obtained in the Verbal Fluency M test (75 and 65, respectively). CONCLUSIONS: The neuropsychological tests showed moderate diagnostic value for the identification of schizophrenia patients. These findings suggested that the cognitive impairment measured by these tests might not be homogeneous among schizophrenia patients.
Resumo:
Dissertação para obtenção do Grau de Mestre em Contabilidade e Finanças Orientadora: Professora Doutora Patrícia Ramos
Resumo:
PURPOSE: Fatty liver disease (FLD) is an increasing prevalent disease that can be reversed if detected early. Ultrasound is the safest and ubiquitous method for identifying FLD. Since expert sonographers are required to accurately interpret the liver ultrasound images, lack of the same will result in interobserver variability. For more objective interpretation, high accuracy, and quick second opinions, computer aided diagnostic (CAD) techniques may be exploited. The purpose of this work is to develop one such CAD technique for accurate classification of normal livers and abnormal livers affected by FLD. METHODS: In this paper, the authors present a CAD technique (called Symtosis) that uses a novel combination of significant features based on the texture, wavelet transform, and higher order spectra of the liver ultrasound images in various supervised learning-based classifiers in order to determine parameters that classify normal and FLD-affected abnormal livers. RESULTS: On evaluating the proposed technique on a database of 58 abnormal and 42 normal liver ultrasound images, the authors were able to achieve a high classification accuracy of 93.3% using the decision tree classifier. CONCLUSIONS: This high accuracy added to the completely automated classification procedure makes the authors' proposed technique highly suitable for clinical deployment and usage.
Resumo:
Objective: Summarize all relevant findings in published literature regarding the potential dose reduction related to image quality using Sinogram-Affirmed Iterative Reconstruction (SAFIRE) compared to Filtered Back Projection (FBP). Background: Computed Tomography (CT) is one of the most used radiographic modalities in clinical practice providing high spatial and contrast resolution. However it also delivers a relatively high radiation dose to the patient. Reconstructing raw-data using Iterative Reconstruction (IR) algorithms has the potential to iteratively reduce image noise while maintaining or improving image quality of low dose standard FBP reconstructions. Nevertheless, long reconstruction times made IR unpractical for clinical use until recently. Siemens Medical developed a new IR algorithm called SAFIRE, which uses up to 5 different strength levels, and poses an alternative to the conventional IR with a significant reconstruction time reduction. Methods: MEDLINE, ScienceDirect and CINAHL databases were used for gathering literature. Eleven articles were included in this review (from 2012 to July 2014). Discussion: This narrative review summarizes the results of eleven articles (using studies on both patients and phantoms) and describes SAFIRE strengths for noise reduction in low dose acquisitions while providing acceptable image quality. Conclusion: Even though the results differ slightly, the literature gathered for this review suggests that the dose in current CT protocols can be reduced at least 50% while maintaining or improving image quality. There is however a lack of literature concerning paediatric population (with increased radiation sensitivity). Further studies should also assess the impact of SAFIRE on diagnostic accuracy.
Resumo:
This paper analyses the provision of auxiliary clinical services that are typically carried out within the hospital. We estimate a exible cost function for the three most important (cost- wise) diagnostic techniques and therapeutic services in Portuguese hospitals: Clinical Pathology, Medical Imaging and Physical Medicine and Rehabilitation. Our objective in carrying out this estimation is the evaluation of economies of scale and scope in the provision of these services. For all services, we nd evidence of ray economies of scale and some evidence of economies of scope. These results have important policy implications and can be related to the ongoing discussion of where and how should hospitals provide these services.
Resumo:
XX Symposium of Brazilian Medicinal Plants & X International Congress of Ethnopharmacology. S. Paulo, Brasil.
Resumo:
Introduction: Anxiety is a common problem in primary care and specialty medical settings. Treating an anxious patient takes more time and adds stress to staff. Unrecognized anxiety may lead to exam repetition, and impedance of exam performance. Objective: The aim of the study was to examine the anxiety levels of patients who are to undergo diagnostic exams related to cancer diagnostic: PET/CT and mammography. Methods: Two hundred and thirty two patients who undergo PET/CT and one hundred thirteen women who undergo mammography filled out one questionnaire after the procedure to determine their concerns, expectations and perceptions of anxiety. Results: Our results show that the main causes of anxiety in patients who are having a PET/CT is the fear of the procedure itself and fear of the results. Patients who suffered from greater anxiety were those who were scanned during the initial stage of an oncological disease. On the other hand, the diagnostic is the main cause of anxiety in women who are requiring a mammography. 28% of the women reported having experienced pain or intense pain. Conclusions: The performance of diagnostic exams related to cancer diagnostic like a PET/CT and a mammography are important and statistically generators of anxiety. Patients are often poorly informed and present with a range of anxieties that may ultimately affect examination quality. These results provide expertise that can be used in the development of future training programs to integrate post-graduate courses of health professionals.
Resumo:
A survey of the prevalence of Trypanosoma cruzi infection was carried out in Oitis, a small community in the State of Piaui, Brazil. Two hundred and sixty five individuals were screened by microscopic examination, hémoculture, indirect immunofluorescence (IFA), enzyme-linked immunosorbent assay (ELISA), and competitive enzyme-linked immunosorbent assay (C-ELISA) using the monoclonal antibody TCF87 against to a 25kd T. cruzi antigen. Seropositivity was 14.3% by the IFA test, 14.7% by ELISA, and 13.2% by C-ELISA. The C-ELISA using the TCF87 monoclonal antibody seems to be applicable in serodiagnosis of Chagas' disease.
Resumo:
The specificity and sensitivity of the enzyme immunoassay (EIA), presently used in South America areas where hydatidosis caused by Echinococcus granulosus is endemic, was compared to two alternative EIA. One of these uses an hydatid antigen of different prepraration and the other vesicular fluid of Taenia crassiceps cisticerci (VFCC). The effect of previous neutralization in the serum sample of antibodies anti-normal ovine or murine sera and anti-phosphorylcholine on the diagnostic efficiency of these EIA was studied. The frequency of distribution of the titers obtained with normal sera, hydatid sera positive to DD5 test and hydatid sera negative to DD5 test in three EIA systems was analyzed. Results showed a significant decrease of sensitivity of the EIA using VFCC when compared to these EIA using hydatid antigens. This makes inconvenient the use of VFCC for the immunodiagnosis of hydatid disease. No significant differences between the two EIA using hydatid antigens were observed. SDS-PAGE analysis showed remarkable differences between the VFCC and the hydatid antigens composition and some differences among these latters probably due to manufacturing procedures.
Resumo:
Three distinct syndromes caused by schistosomiasis have been described: cercarial dermatitis or swimmer's itch, acute schistosomiasis or Katayama fever, and chronic schistosomiasis. Complications of acute schistosomiasis have also been reported. The absence of a serological marker for the acute stage has hindered early diagnosis and treatment. Recently, an ELISA test using KLH (keyhole limpet haemocyanin) as antigen, has proved useful in differentiating acute from chronic schistosomiasis mansoni. Clinical and experimental evidence indicate that steroids act synergistically with schistosomicides in the treatment of Katayama syndrome. In this paper, clinical, diagnostic and therapeutic features of acute schistosomiasis are updated.