958 resultados para DC system efficiency


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Starting on June 2011, NGCPV is the first project funded jointly between the European Commission (EC) and the New Energy and Industrial Technology Development Organization (NEDO) of Japan to research on new generation concentration photovoltaics (CPV). The Project, through a collaborative research between seven European and nine Japanese leading research centers in the field of CPV, aims at lowering the cost of the CPVproduced photovoltaic kWh down to 5 ?cents. The main objective of the project is to improve the present concentrator cell, module and system efficiency, as well as developing advanced characterization tools for CPV components and systems. As particular targets, the project aims at achieving a cell efficiency of at least 45% and a CPV module with an efficiency greater than 35%. This paper describes the R&D activities that are being carried out within the NGCPV project and summarizes some of the most relevant results that have already been attained, for instance: the manufacturing of a 44.4% world record efficiency triple junction solar cell (by Sharp Corp.) and the installation of a 50 kWp experimental CPV plant in Spain, which will be used to obtain accurate forecasts of the energy produced at system level.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

n this paper, we present a theoretical model based on the detailed balance theory of solar thermophotovoltaic systems comprising multijunction photovoltaic cells, a sunlight concentrator and spectrally selective surfaces. The full system has been defined by means of 2n + 8 variables (being n the number of sub-cells of the multijunction cell). These variables are as follows: the sunlight concentration factor, the absorber cut-off energy, the emitter-to-absorber area ratio, the emitter cut-off energy, the band-gap energy(ies) and voltage(s) of the sub-cells, the reflectivity of the cells' back-side reflector, the emitter-to-cell and cell-to-cell view factors and the emitter-to-cell area ratio. We have used this model for carrying out a multi-variable system optimization by means of a multidimensional direct-search algorithm. This analysis allows to find the set of system variables whose combined effects results in the maximum overall system efficiency. From this analysis, we have seen that multijunction cells are excellent candidates to enhance the system efficiency and the electrical power density. Particularly, multijunction cells report great benefits for systems with a notable presence of optical losses, which are unavoidable in practical systems. Also, we have seen that the use of spectrally selective absorbers, rather than black-body absorbers, allows to achieve higher system efficiencies for both lower concentration and lower emitter-to-absorber area ratio. Finally, we have seen that sun-to-electricity conversion efficiencies above 30% and electrical power densities above 50 W/cm2 are achievable for this kind of systems.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work is related to the output impedance improvement of a Multiphase Buck converter with Peak Current Mode Control (PCMC) by means of introducing an additional power path that virtually increases the output capacitance during transients. Various solutions that can be employed to improve the dynamic behavior of the converter system exist, but nearly all solutions are developed for a Single Phase Buck converter with Voltage Mode Control (VMC), while in the VRM applications, due to the high currents, the system is usually implemented as a Multiphase Buck Converter with Current Mode Control. The additional energy path, as presented here, is introduced with the Output Impedance Correction Circuit (OICC) based on the Controlled Current Source (CCS). The OICC is used to inject or extract a current n-1 times larger than the output capacitor current, thus virtually increasing n times the value of the output capacitance during the transients. Furthermore, this work extends the OICC concept to a Multiphase Buck Converter system while comparing proposed solution with the system that has n times bigger output capacitor. In addition, the OICC is implemented as a Synchronous Buck Converter with PCMC, thus reducing its influence on the system efficiency.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work is related to the output impedance improvement of a Multiphase Buck converter with Peak Current Mode Control (PCMC) by means of introducing an additional power path that virtually increases the output capacitance during transients. Various solutions that can be employed to improve the dynamic behavior of the converter system exist, but nearly all solutions are developed for a Single Phase Buck converter with Voltage Mode Control (VMC), while in the VRM applications, due to the high currents, the system is usually implemented as a Multiphase Buck Converter with Current Mode Control. The Output Impedance Correction Circuit (OICC) is used to inject or extract a current n-1 times larger than the output capacitor current, thus virtually increasing n times the value of the output capacitance during the transients. Furthermore, this work extends the OICC concept to a Multiphase Buck Converter system while comparing proposed solution with the system that has n times bigger output capacitor. In addition, the OICC is implemented as a Synchronous Buck Converter with PCMC, thus reducing its influence on the system efficiency

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This article presents an alternative approach to the decision-making process in transport strategy design. The study explores the possibility of integrating forecasting, assessment and optimization procedures in support of a decision-making process designed to reach the best achievable scenario through mobility policies. Long-term evaluation, as required by a dynamic system such as a city, is provided by a strategic Land-Use and Transport Interaction (LUTI) model. The social welfare achieved by implementing mobility LUTI model policies is measured through a cost-benefit analysis and maximized through an optimization process throughout the evaluation period. The method is tested by optimizing a pricing policy scheme in Madrid on a cordon toll in a context requiring system efficiency, social equity and environmental quality. The optimized scheme yields an appreciable increase in social surplus through a relatively low rate compared to other similar pricing toll schemes. The results highlight the different considerations regarding mobility impacts on the case study area, as well as the major contributors to social welfare surplus. This leads the authors to reconsider the cost-analysis approach, as defined in the study, as the best option for formulating sustainability measures.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

El requerimiento de proveer alta frecuencia de datos en los modernos sistema de comunicación inalámbricos resulta en complejas señales moduladas de radio-frequencia (RF) con un gran ancho de banda y alto ratio pico-promedio (PAPR). Para garantizar la linealidad del comportamiento, los amplificadores lineales de potencia comunes funcionan típicamente entre 4 y 10 dB de back-o_ desde la máxima potencia de salida, ocasionando una baja eficiencia del sistema. La eliminación y restauración de la evolvente (EER) y el seguimiento de la evolvente (ET) son dos prometedoras técnicas para resolver el problema de la eficiencia. Tanto en EER como en ET, es complicado diseñar un amplificador de potencia que sea eficiente para señales de RF de alto ancho de banda y alto PAPR. Una propuesta común para los amplificadores de potencia es incluir un convertidor de potencia de muy alta eficiencia operando a frecuencias más altas que el ancho de banda de la señal RF. En este caso, la potencia perdida del convertidor ocasionado por la alta frecuencia desaconseja su práctica cuando el ancho de banda es muy alto. La solución a este problema es el enfoque de esta disertación que presenta dos arquitecturas de amplificador evolvente: convertidor híbrido-serie con una técnica de evolvente lenta y un convertidor multinivel basado en un convertidor reductor multifase con control de tiempo mínimo. En la primera arquitectura, una topología híbrida está compuesta de una convertidor reductor conmutado y un regulador lineal en serie que trabajan juntos para ajustar la tensión de salida para seguir a la evolvente con precisión. Un algoritmo de generación de una evolvente lenta crea una forma de onda con una pendiente limitada que es menor que la pendiente máxima de la evolvente original. La salida del convertidor reductor sigue esa forma de onda en vez de la evolvente original usando una menor frecuencia de conmutación, porque la forma de onda no sólo tiene una pendiente reducida sino también un menor ancho de banda. De esta forma, el regulador lineal se usa para filtrar la forma de onda tiene una pérdida de potencia adicional. Dependiendo de cuánto se puede reducir la pendiente de la evolvente para producir la forma de onda, existe un trade-off entre la pérdida de potencia del convertidor reductor relacionada con la frecuencia de conmutación y el regulador lineal. El punto óptimo referido a la menor pérdida de potencia total del amplificador de evolvente es capaz de identificarse con la ayuda de modelo preciso de pérdidas que es una combinación de modelos comportamentales y analíticos de pérdidas. Además, se analiza el efecto en la respuesta del filtro de salida del convertidor reductor. Un filtro de dampeo paralelo extra es necesario para eliminar la oscilación resonante del filtro de salida porque el convertidor reductor opera en lazo abierto. La segunda arquitectura es un amplificador de evolvente de seguimiento de tensión multinivel. Al contrario que los convertidores que usan multi-fuentes, un convertidor reductor multifase se emplea para generar la tensión multinivel. En régimen permanente, el convertidor reductor opera en puntos del ciclo de trabajo con cancelación completa del rizado. El número de niveles de tensión es igual al número de fases de acuerdo a las características del entrelazamiento del convertidor reductor. En la transición, un control de tiempo mínimo (MTC) para convertidores multifase es novedosamente propuesto y desarrollado para cambiar la tensión de salida del convertidor reductor entre diferentes niveles. A diferencia de controles convencionales de tiempo mínimo para convertidores multifase con inductancia equivalente, el propuesto MTC considera el rizado de corriente por cada fase basado en un desfase fijo que resulta en diferentes esquemas de control entre las fases. La ventaja de este control es que todas las corrientes vuelven a su fase en régimen permanente después de la transición para que la siguiente transición pueda empezar muy pronto, lo que es muy favorable para la aplicación de seguimiento de tensión multinivel. Además, el control es independiente de la carga y no es afectado por corrientes de fase desbalanceadas. Al igual que en la primera arquitectura, hay una etapa lineal con la misma función, conectada en serie con el convertidor reductor multifase. Dado que tanto el régimen permanente como el estado de transición del convertidor no están fuertemente relacionados con la frecuencia de conmutación, la frecuencia de conmutación puede ser reducida para el alto ancho de banda de la evolvente, la cual es la principal consideración de esta arquitectura. La optimización de la segunda arquitectura para más alto anchos de banda de la evolvente es presentada incluyendo el diseño del filtro de salida, la frecuencia de conmutación y el número de fases. El área de diseño del filtro está restringido por la transición rápida y el mínimo pulso del hardware. La rápida transición necesita un filtro pequeño pero la limitación del pulso mínimo del hardware lleva el diseño en el sentido contrario. La frecuencia de conmutación del convertidor afecta principalmente a la limitación del mínimo pulso y a las pérdidas de potencia. Con una menor frecuencia de conmutación, el ancho de pulso en la transición es más pequeño. El número de fases relativo a la aplicación específica puede ser optimizado en términos de la eficiencia global. Otro aspecto de la optimización es mejorar la estrategia de control. La transición permite seguir algunas partes de la evolvente que son más rápidas de lo que el hardware puede soportar al precio de complejidad. El nuevo método de sincronización de la transición incrementa la frecuencia de la transición, permitiendo que la tensión multinivel esté más cerca de la evolvente. Ambas estrategias permiten que el convertidor pueda seguir una evolvente con un ancho de banda más alto que la limitación de la etapa de potencia. El modelo de pérdidas del amplificador de evolvente se ha detallado y validado mediante medidas. El mecanismo de pérdidas de potencia del convertidor reductor tiene que incluir las transiciones en tiempo real, lo cual es diferente del clásico modelos de pérdidas de un convertidor reductor síncrono. Este modelo estima la eficiencia del sistema y juega un papel muy importante en el proceso de optimización. Finalmente, la segunda arquitectura del amplificador de evolvente se integra con el amplificador de clase F. La medida del sistema EER prueba el ahorro de energía con el amplificador de evolvente propuesto sin perjudicar la linealidad del sistema. ABSTRACT The requirement of delivering high data rates in modern wireless communication systems results in complex modulated RF signals with wide bandwidth and high peak-to-average ratio (PAPR). In order to guarantee the linearity performance, the conventional linear power amplifiers typically work at 4 to 10 dB back-off from the maximum output power, leading to low system efficiency. The envelope elimination and restoration (EER) and envelope tracking (ET) are two promising techniques to overcome the efficiency problem. In both EER and ET, it is challenging to design efficient envelope amplifier for wide bandwidth and high PAPR RF signals. An usual approach for envelope amplifier includes a high-efficiency switching power converter operating at a frequency higher than the RF signal's bandwidth. In this case, the power loss of converter caused by high switching operation becomes unbearable for system efficiency when signal bandwidth is very wide. The solution of this problem is the focus of this dissertation that presents two architectures of envelope amplifier: a hybrid series converter with slow-envelope technique and a multilevel converter based on a multiphase buck converter with the minimum time control. In the first architecture, a hybrid topology is composed of a switched buck converter and a linear regulator in series that work together to adjust the output voltage to track the envelope with accuracy. A slow envelope generation algorithm yields a waveform with limited slew rate that is lower than the maximum slew rate of the original envelope. The buck converter's output follows this waveform instead of the original envelope using lower switching frequency, because the waveform has not only reduced slew rate but also reduced bandwidth. In this way, the linear regulator used to filter the waveform has additional power loss. Depending on how much reduction of the slew rate of envelope in order to obtain that waveform, there is a trade-off between the power loss of buck converter related to the switching frequency and the power loss of linear regulator. The optimal point referring to the lowest total power loss of this envelope amplifier is identified with the help of a precise power loss model that is a combination of behavioral and analytic loss model. In addition, the output filter's effect on the response is analyzed. An extra parallel damping filter is needed to eliminate the resonant oscillation of output filter L and C, because the buck converter operates in open loop. The second architecture is a multilevel voltage tracking envelope amplifier. Unlike the converters using multi-sources, a multiphase buck converter is employed to generate the multilevel voltage. In the steady state, the buck converter operates at complete ripple cancellation points of duty cycle. The number of the voltage levels is equal to the number of phases according the characteristics of interleaved buck converter. In the transition, a minimum time control (MTC) for multiphase converter is originally proposed and developed for changing the output voltage of buck converter between different levels. As opposed to conventional minimum time control for multiphase converter with equivalent inductance, the proposed MTC considers the current ripple of each phase based on the fixed phase shift resulting in different control schemes among the phases. The advantage of this control is that all the phase current return to the steady state after the transition so that the next transition can be triggered very soon, which is very favorable for the application of multilevel voltage tracking. Besides, the control is independent on the load condition and not affected by the unbalance of phase current. Like the first architecture, there is also a linear stage with the same function, connected in series with the multiphase buck converter. Since both steady state and transition state of the converter are not strongly related to the switching frequency, it can be reduced for wide bandwidth envelope which is the main consideration of this architecture. The optimization of the second architecture for wider bandwidth envelope is presented including the output filter design, switching frequency and the number of phases. The filter design area is restrained by fast transition and the minimum pulse of hardware. The fast transition needs small filter but the minimum pulse of hardware limitation pushes the filter in opposite way. The converter switching frequency mainly affects the minimum pulse limitation and the power loss. With lower switching frequency, the pulse width in the transition is smaller. The number of phases related to specific application can be optimized in terms of overall efficiency. Another aspect of optimization is improving control strategy. Transition shift allows tracking some parts of envelope that are faster than the hardware can support at the price of complexity. The new transition synchronization method increases the frequency of transition, allowing the multilevel voltage to be closer to the envelope. Both control strategies push the converter to track wider bandwidth envelope than the limitation of power stage. The power loss model of envelope amplifier is detailed and validated by measurements. The power loss mechanism of buck converter has to include the transitions in real time operation, which is different from classical power loss model of synchronous buck converter. This model estimates the system efficiency and play a very important role in optimization process. Finally, the second envelope amplifier architecture is integrated with a Class F amplifier. EER system measurement proves the power saving with the proposed envelope amplifier without disrupting the linearity performance.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Electrical power systems are changing their traditional structure, which was based on a little number of large generating power plants placed at great distances from loads by new models that tend to split the big production nodes in many smaller ones. The set of small groups which are located close to consumers and provide safe and quality energy is called distributed generation (DG). The proximity of the sources to the loads reduces losses associated with transportation and increases overall system efficiency. DG also favors the inclusion of renewable energy sources in isolated electrical systems or remote microgrids, because they can be installed where the natural resource is located. In both cases, as weak grids unable to get help from other nearby networks, it is essential to ensure appropriate behavior of DG sources to guarantee power system safety and stability. The grid codes sets out the technical requirements to be fulfilled for the sources connected in these electrical networks. In technical literature it is rather easy to find and compare grid codes for interconnected electrical systems. However, the existing literature is incomplete and sparse regarding isolated electrical systems and this happens due to the difficulties inherent in the pursuit of codes. Some countries have developed their own legislation only for their island territory (as Spain or France), others apply the same set of rules as in mainland, another group of island countries have elaborated a complete grid code for all generating sources and some others lack specific regulation. This paper aims to make a complete review of the state of the art in grid codes applicable to isolated systems, setting the comparison between them and defining the guidelines predictably followed by the upcoming regulations in these particular systems.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Esta tesis pretende contribuir al fomento y utilización de la energía solar como alternativa para la producción de agua caliente en el sector agroindustrial. La demanda de agua caliente es un aspecto clave en un gran número de agroindustrias y explotaciones agrarias. Esta demanda presenta una gran variabilidad, tanto en los horarios en que se solicita como en la temperatura del agua del depósito requerida (TADr), difiriendo del perfil de demanda habitual para uso doméstico. Existe una necesidad de profundizar en la influencia que tiene la variación de la TADr en la eficiencia y viabilidad de estos sistemas. El objetivo principal de esta tesis es caracterizar el funcionamiento de un sistema solar térmico (SST) con captador de tubos de vacío (CTV) para producir agua a temperaturas superiores a las habituales en estos sistemas. Se pretende determinar la influencia que la TADr tiene sobre la eficiencia energética del sistema, cuantificar el volumen de agua caliente que es capaz de suministrar en función de la TADr y determinar la rentabilidad del SST como sistema complementario de suministro. Para ello, se ha diseñado, instalado y puesto a punto un sistema experimental de calentamiento de agua, monitorizando su funcionamiento a diferentes TADr bajo condiciones ambientales reales. Los resultados cuantifican cómo el aumento de la TADr provoca una disminución de la energía suministrada al depósito, pudiendo superar diferencias de 1000 Wh m-2 d-1 entre 40 ºC y 80 ºC, para valores de irradiación solar próximos a 8000 Wh m-2 d-1 (la eficiencia del sistema oscila entre 73% y 56%). Esta reducción es consecuencia de la disminución de la eficiencia del captador y del aumento de las pérdidas de calor en las tuberías del circuito. En cuanto al agua suministrada, cuanto mayor es la TADr, mayor es la irradiación solar requerida para que tenga lugar la primera descarga de agua, aumentando el tiempo entre descargas y disminuyendo el número de éstas a lo largo del día. A medida que se incrementa la TADr, se produce una reducción del volumen de agua suministrado a la TADr, por factores como la pérdida de eficiencia del captador, las pérdidas en las tuberías, la energía acumulada en el agua que no alcanza la TADr y la mayor energía extraída del sistema en el agua producida. Para una TADr de 80 ºC, una parte importante de la energía permanece acumulada en el depósito sin alcanzar la TADr al final del día. Para aprovechar esta energía sería necesario disponer de un sistema complementario de suministro, ya que las pérdidas de calor nocturnas en el depósito pueden reducir considerablemente la energía útil disponible al día siguiente. La utilización del sistema solar como sistema único de suministro es inviable en la mayoría de los casos, especialmente a TADr elevadas, al no ajustarse la demanda de agua caliente a la estacionalidad de la producción del sistema solar, y al existir muchos días sin producción de agua caliente por la ausencia de irradiación mínima. Por el contrario, la inversión del sistema solar como sistema complementario para suministrar parte de la demanda térmica de una instalación es altamente recomendable. La energía útil anual del sistema solar estimada oscila entre 1322 kWh m-2 y 1084 kWh m-2. La mayor rentabilidad se obtendría suponiendo la existencia de una caldera eléctrica, donde la inversión se recuperaría en pocos años -entre 5.7 años a 40 ºC y 7.2 años a 80 ºC -. La rentabilidad también es elevada suponiendo la existencia de una caldera de gasóleo, con periodos de recuperación inferiores a 10 años. En una industria ficticia con demanda de 100 kWh d-1 y caldera de gasóleo existente, la inversión en una instalación solar optimizada sería rentable a cualquier TADr, con valores de VAN cercanos a la inversión realizada -12000 € a 80 ºC y 15000€ a 40 ºC- y un plazo de recuperación de la inversión entre 8 y 10 años. Los resultados de este estudio pueden ser de gran utilidad a la hora de determinar la viabilidad de utilización de sistemas similares para suministrar la demanda de agua caliente de agroindustrias y explotaciones agropecuarias, o para otras aplicaciones en las que se demande agua a temperaturas distintas de la habitual en uso doméstico (60 ºC). En cada caso, los rendimientos y la rentabilidad vendrán determinados por la irradiación de la zona, la temperatura del agua requerida y la curva de demanda de los procesos específicos. ABSTRACT The aim of this thesis is to contribute to the development and use of solar energy as an alternative for producing hot water in the agribusiness sector. Hot water supply is a key issue for a great many agribusinesses and agricultural holdings. Both hot water demand times and required tank water temperature (rTWT) are highly variable, where the demand profile tends to differ from domestic use. Further research is needed on how differences in rTWT influence the performance and feasibility of these systems. The main objective of this thesis is to characterize the performance and test the feasibility of an evacuated tube collector (ETC) solar water heating (SWH) system providing water at a higher temperature than is usual for such systems. The aim is to determine what influence the rTWT has on the system’s energy efficiency, quantify the volume of hot water that the system is capable of supplying at the respective rTWT and establish whether SWH is feasible as a booster supply system for the different analysed rTWTs. To do this, a prototype water heating system has been designed, installed and commissioned and its performance monitored at different rTWTs under real operating conditions. The quantitative results show that a higher rTWT results in a lower energy supply to the tank, where the differences may be greater than 1000 Wh m-2 d-1 from 40 ºC to 80 ºC for insolation values of around 8000 Wh m-2 d-1 (system efficiency ranges from 73% to 56%). The drop in supply is due to lower collector efficiency and greater heat losses from the pipe system. As regards water supplied at the rTWT, the insolation required for the first withdrawal of water to take place is greater at higher rTWTs, where the time between withdrawals increases and the number of withdrawals decreases throughout the day. As rTWT increases, the volume of water supplied at the rTWT decreases due to factors such as lower collector efficiency, pipe system heat losses, energy stored in the water at below the rTWT and more energy being extracted from the system by water heating. For a rTWT of 80 ºC, much of the energy is stored in the tank at below the rTWT at the end of the day. A booster supply system would be required to take advantage of this energy, as overnight tank heat losses may significantly reduce the usable energy available on the following day. It is often not feasible to use the solar system as a single supply system, especially at high rTWTs, as, unlike the supply from the solar heating system which does not produce hot water on many days of the year because insolation is below the required minimum, hot water demand is not seasonal. On the other hand, investment in a solar system as a booster system to meet part of a plant’s heat energy demand is highly recommended. The solar system’s estimated annual usable energy ranges from 1322 kWh m-2 to 1084 kWh m-2. Cost efficiency would be greatest if there were an existing electric boiler, where the payback period would be just a few years —from 5.7 years at 40 ºC to 7.2 years at 80 ºC—. Cost efficiency is also high if there is an existing diesel boiler with payback periods of under 10 years. In a fictitious industry with a demand of 100 kWh day-1 and an existing diesel boiler, the investment in the solar plant would be highly recommended at any rTWT, with a net present value similar to investment costs —12000 € at 80 ºC and 15000 € at 40 ºC— and a payback period of 10 years. The results of this study are potentially very useful for determining the feasibility of using similar systems for meeting the hot water demand of agribusinesses and arable and livestock farms or for other applications demanding water at temperatures not typical of domestic demand (60ºC). Performance and cost efficiency will be determined by the regional insolation, the required water temperature and the demand curve of the specific processes in each case.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

El trabajo presentado en este documento se centra en la temática de la transferencia inalámbrica de energía, concretamente en aplicaciones de campo lejano, para llevar a cabo dicho trabajo nos centraremos en el diseño, implementación y medición de una rectenna operando en la banda ISM concretamente a una frecuencia de 2.45GHz, el objetivo primordial de este trabajo será analizar que parámetros intervienen en la eficiencia de conversión en la etapa de RF-DC a fin de lograr la máxima eficiencia de conversión posible. Para llevar a cabo dicho análisis se emplearán herramientas informáticas, concretamente se hará uso del software AWR Microwave Office, a través del cual se realizarán simulaciones SourcePull a fin de determinar la impedancia óptima de entrada que se le debe presentar a la etapa rectificadora RF-DC para conseguir la máxima eficiencia de conversión, una vez realizadas dichas pruebas se implementará físicamente un circuito rectenna a través del cual realizar medidas de SourcePull mediante un Wide Matching Range Slide Screw Tuner de MAURY MICROWAVE para cotejar las posibles diferencias con los resultados obtenidos en las simulaciones. Tras la fase de pruebas SourcePull se extrapolará una red de entrada en base a los datos obtenidos en las mediciones anteriores y se diseñará y fabricará un circuito rectenna con máxima eficiencia de conversión para un conjunto de valores de potencia de entrada de RF y carga de DC, tras lo cual se analizará la eficiencia del circuito diseñado para diferentes valores de potencia de RF de entrada y carga de DC. Como elemento rectificador emplearemos en nuestro trabajo el diodo Schottky HSMS-2820, los diodos Schottky se caracterizan por tener tiempos de conmutación relativamente bajos y pérdidas en directa reducidas los cual será fundamental a la hora de trabajar con niveles reducidos de potencia de RF de entrada, para implementar el circuito se empleará un substrato FR4 con espesor de 0.8mm para disminuir en la mayor medida posible las pérdidas introducidas por el dieléctrico, se analizarán diferentes posibilidades a la hora de implementar el filtro de RF a la salida del diodo rectificador y finalmente se optará por el empleo de un stub radial ya que será este el que mejor ancho de banda nos proporcione. Los resultados simulados se compararán con los resultados medidos sobre el circuito rectenna para determinar la similitud entre ambos. ABSTRACT. The work presented in this paper focuses on the issue of wireless transfer of energy, particularly applied to far-field applications, to carry out this work we focus on the design, implementation and measurement of a rectenna operating in the ISM band specifically at a frequency of 2.45GHz, the primary objective of this study is to analyze any parameter involved in the RF-DC conversion efficiency in order to achieve the maximum conversion efficiency as possible. Computer analysis tools will be used, particularly AWR Microwave Office software, in order to carry out SourcePull simulations to determine the optimal input impedance which must be presented to the rectifier stage for maximum conversion efficiency, once obtained, a rectenna circuit will be implemented to compute SourcePull measurements, and finally simulated results will be compared to measured results. Once obtained the result, an input network impedance is extrapolated based on data from previous measurements to design and implement a rectenna circuit with high conversion efficiency for a set of RF input power and DC load values , after that, the designed circuit efficiency will be analyzed for different values of RF input power and DC load. In this work a HSMS-2820 Schottky diode will be used as the rectifier , Schottky diodes are characterized by relatively low switching times and reduced direct losses, that properties will be essential when working with low RF input power levels , to implement the circuit a FR4 substrate with 0.8mm thickness is used to reduce as much as possible the dielectric losses, different possibilities to implement the RF filter to the output of the rectifier diode will be analyzed, finally we will opt for the use of a radial stub as this will provide the best bandwidth possible. The simulated results are compared with the results measured on the rectenna circuit to determine the similarity between them.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Various micro-radial compressor configurations were investigated using one-dimensional meanline and computational fluid dynamics (CFD) techniques for use in a micro gas turbine (MGT) domestic combined heat and power (DCHP) application. Blade backsweep, shaft speed, and blade height were varied at a constant pressure ratio. Shaft speeds were limited to 220 000 r/min, to enable the use of a turbocharger bearing platform. Off-design compressor performance was established and used to determine the MGT performance envelope; this in turn was used to assess potential cost and environmental savings in a heat-led DCHP operating scenario within the target market of a detached family home. A low target-stage pressure ratio provided an opportunity to reduce diffusion within the impeller. Critically for DCHP, this produced very regular flow, which improved impeller performance for a wider operating envelope. The best performing impeller was a low-speed, 170 000 r/min, low-backsweep, 15° configuration producing 71.76 per cent stage efficiency at a pressure ratio of 2.20. This produced an MGT design point system efficiency of 14.85 per cent at 993 W, matching prime movers in the latest commercial DCHP units. Cost and CO2 savings were 10.7 per cent and 6.3 per cent, respectively, for annual power demands of 17.4 MWht and 6.1 MWhe compared to a standard condensing boiler (with grid) installation. The maximum cost saving (on design point) was 14.2 per cent for annual power demands of 22.62 MWht and 6.1 MWhe corresponding to an 8.1 per cent CO2 saving. When sizing, maximum savings were found with larger heat demands. When sized, maximum savings could be made by encouraging more electricity export either by reducing household electricity consumption or by increasing machine efficiency.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The advent of the harmonic neutralised shunt Converter Compensator as a practical means of reactive power compensation in power transmission systems has cleared ground for wider application of this type of equipment. An experimental 24-pulse voltage sourced convector has been successfully applied in controlling the terminal power factor of a 1.5kW, 240V three phase cage rotor induction motor, whose winding has been used in place of the usual phase shifting transformers. To achieve this, modifications have been made to the conventional stator winding of the induction machine. These include an unconventional phase spread and facilitation of compensator connections to selected tapping points between stator coils to give a three phase winding with a twelve phase connection to the twenty four pulse converter. Theoretical and experimental assessments of the impact of these modifications and attachment of the compensator have shown that there is a slight reduction in the torque developed at a given slip and in the combined system efficiency. There is also an increase in the noise level, also a consequence of the harmonics. The stator leakage inductance gave inadequate coupling reactance between the converter and the effective voltage source, necessitating the use of external inductors in each of the twelve phases. The terminal power factor is fully controllable when the induction machine is used either as a motor or as a generator.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents an assessment of the technical and economic performance of thermal processes to generate electricity from a wood chip feedstock by combustion, gasification and fast pyrolysis. The scope of the work begins with the delivery of a wood chip feedstock at a conversion plant and ends with the supply of electricity to the grid, incorporating wood chip preparation, thermal conversion, and electricity generation in dual fuel diesel engines. Net generating capacities of 1–20 MWe are evaluated. The techno-economic assessment is achieved through the development of a suite of models that are combined to give cost and performance data for the integrated system. The models include feed pretreatment, combustion, atmospheric and pressure gasification, fast pyrolysis with pyrolysis liquid storage and transport (an optional step in de-coupled systems) and diesel engine or turbine power generation. The models calculate system efficiencies, capital costs and production costs. An identical methodology is applied in the development of all the models so that all of the results are directly comparable. The electricity production costs have been calculated for 10th plant systems, indicating the costs that are achievable in the medium term after the high initial costs associated with novel technologies have reduced. The costs converge at the larger scale with the mean electricity price paid in the EU by a large consumer, and there is therefore potential for fast pyrolysis and diesel engine systems to sell electricity directly to large consumers or for on-site generation. However, competition will be fierce at all capacities since electricity production costs vary only slightly between the four biomass to electricity systems that are evaluated. Systems de-coupling is one way that the fast pyrolysis and diesel engine system can distinguish itself from the other conversion technologies. Evaluations in this work show that situations requiring several remote generators are much better served by a large fast pyrolysis plant that supplies fuel to de-coupled diesel engines than by constructing an entire close-coupled system at each generating site. Another advantage of de-coupling is that the fast pyrolysis conversion step and the diesel engine generation step can operate independently, with intermediate storage of the fast pyrolysis liquid fuel, increasing overall reliability. Peak load or seasonal power requirements would also benefit from de-coupling since a small fast pyrolysis plant could operate continuously to produce fuel that is stored for use in the engine on demand. Current electricity production costs for a fast pyrolysis and diesel engine system are 0.091/kWh at 1 MWe when learning effects are included. These systems are handicapped by the typical characteristics of a novel technology: high capital cost, high labour, and low reliability. As such the more established combustion and steam cycle produces lower cost electricity under current conditions. The fast pyrolysis and diesel engine system is a low capital cost option but it also suffers from relatively low system efficiency particularly at high capacities. This low efficiency is the result of a low conversion efficiency of feed energy into the pyrolysis liquid, because of the energy in the char by-product. A sensitivity analysis has highlighted the high impact on electricity production costs of the fast pyrolysis liquids yield. The liquids yield should be set realistically during design, and it should be maintained in practice by careful attention to plant operation and feed quality. Another problem is the high power consumption during feedstock grinding. Efficiencies may be enhanced in ablative fast pyrolysis which can tolerate a chipped feedstock. This has yet to be demonstrated at commercial scale. In summary, the fast pyrolysis and diesel engine system has great potential to generate electricity at a profit in the long term, and at a lower cost than any other biomass to electricity system at small scale. This future viability can only be achieved through the construction of early plant that could, in the short term, be more expensive than the combustion alternative. Profitability in the short term can best be achieved by exploiting niches in the market place and specific features of fast pyrolysis. These include: •countries or regions with fiscal incentives for renewable energy such as premium electricity prices or capital grants; •locations with high electricity prices so that electricity can be sold direct to large consumers or generated on-site by companies who wish to reduce their consumption from the grid; •waste disposal opportunities where feedstocks can attract a gate fee rather than incur a cost; •the ability to store fast pyrolysis liquids as a buffer against shutdowns or as a fuel for peak-load generating plant; •de-coupling opportunities where a large, single pyrolysis plant supplies fuel to several small and remote generators; •small-scale combined heat and power opportunities; •sales of the excess char, although a market has yet to be established for this by-product; and •potential co-production of speciality chemicals and fuel for power generation in fast pyrolysis systems.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This research is focused on the optimisation of resource utilisation in wireless mobile networks with the consideration of the users’ experienced quality of video streaming services. The study specifically considers the new generation of mobile communication networks, i.e. 4G-LTE, as the main research context. The background study provides an overview of the main properties of the relevant technologies investigated. These include video streaming protocols and networks, video service quality assessment methods, the infrastructure and related functionalities of LTE, and resource allocation algorithms in mobile communication systems. A mathematical model based on an objective and no-reference quality assessment metric for video streaming, namely Pause Intensity, is developed in this work for the evaluation of the continuity of streaming services. The analytical model is verified by extensive simulation and subjective testing on the joint impairment effects of the pause duration and pause frequency. Various types of the video contents and different levels of the impairments have been used in the process of validation tests. It has been shown that Pause Intensity is closely correlated with the subjective quality measurement in terms of the Mean Opinion Score and this correlation property is content independent. Based on the Pause Intensity metric, an optimised resource allocation approach is proposed for the given user requirements, communication system specifications and network performances. This approach concerns both system efficiency and fairness when establishing appropriate resource allocation algorithms, together with the consideration of the correlation between the required and allocated data rates per user. Pause Intensity plays a key role here, representing the required level of Quality of Experience (QoE) to ensure the best balance between system efficiency and fairness. The 3GPP Long Term Evolution (LTE) system is used as the main application environment where the proposed research framework is examined and the results are compared with existing scheduling methods on the achievable fairness, efficiency and correlation. Adaptive video streaming technologies are also investigated and combined with our initiatives on determining the distribution of QoE performance across the network. The resulting scheduling process is controlled through the prioritization of users by considering their perceived quality for the services received. Meanwhile, a trade-off between fairness and efficiency is maintained through an online adjustment of the scheduler’s parameters. Furthermore, Pause Intensity is applied to act as a regulator to realise the rate adaptation function during the end user’s playback of the adaptive streaming service. The adaptive rates under various channel conditions and the shape of the QoE distribution amongst the users for different scheduling policies have been demonstrated in the context of LTE. Finally, the work for interworking between mobile communication system at the macro-cell level and the different deployments of WiFi technologies throughout the macro-cell is presented. A QoEdriven approach is proposed to analyse the offloading mechanism of the user’s data (e.g. video traffic) while the new rate distribution algorithm reshapes the network capacity across the macrocell. The scheduling policy derived is used to regulate the performance of the resource allocation across the fair-efficient spectrum. The associated offloading mechanism can properly control the number of the users within the coverages of the macro-cell base station and each of the WiFi access points involved. The performance of the non-seamless and user-controlled mobile traffic offloading (through the mobile WiFi devices) has been evaluated and compared with that of the standard operator-controlled WiFi hotspots.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Virtual machines (VMs) are powerful platforms for building agile datacenters and emerging cloud systems. However, resource management for a VM-based system is still a challenging task. First, the complexity of application workloads as well as the interference among competing workloads makes it difficult to understand their VMs’ resource demands for meeting their Quality of Service (QoS) targets; Second, the dynamics in the applications and system makes it also difficult to maintain the desired QoS target while the environment changes; Third, the transparency of virtualization presents a hurdle for guest-layer application and host-layer VM scheduler to cooperate and improve application QoS and system efficiency. This dissertation proposes to address the above challenges through fuzzy modeling and control theory based VM resource management. First, a fuzzy-logic-based nonlinear modeling approach is proposed to accurately capture a VM’s complex demands of multiple types of resources automatically online based on the observed workload and resource usages. Second, to enable fast adaption for resource management, the fuzzy modeling approach is integrated with a predictive-control-based controller to form a new Fuzzy Modeling Predictive Control (FMPC) approach which can quickly track the applications’ QoS targets and optimize the resource allocations under dynamic changes in the system. Finally, to address the limitations of black-box-based resource management solutions, a cross-layer optimization approach is proposed to enable cooperation between a VM’s host and guest layers and further improve the application QoS and resource usage efficiency. The above proposed approaches are prototyped and evaluated on a Xen-based virtualized system and evaluated with representative benchmarks including TPC-H, RUBiS, and TerraFly. The results demonstrate that the fuzzy-modeling-based approach improves the accuracy in resource prediction by up to 31.4% compared to conventional regression approaches. The FMPC approach substantially outperforms the traditional linear-model-based predictive control approach in meeting application QoS targets for an oversubscribed system. It is able to manage dynamic VM resource allocations and migrations for over 100 concurrent VMs across multiple hosts with good efficiency. Finally, the cross-layer optimization approach further improves the performance of a virtualized application by up to 40% when the resources are contended by dynamic workloads.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Das Verfahren der Lebensmitteltrocknung wird häufig angewendet, um ein Produkt für längere Zeit haltbar zu machen. Obst und Gemüse sind aufgrund ihres hohen Wassergehalts leicht verderblich durch biochemische Vorgänge innerhalb des Produktes, nicht sachgemäße Lagerung und unzureichende Transportmöglichkeiten. Um solche Verluste zu vermeiden wird die direkte Trocknung eingesetzt, welche die älteste Methode zum langfristigen haltbarmachen ist. Diese Methode ist jedoch veraltet und kann den heutigen Herausforderungen nicht gerecht werden. In der vorliegenden Arbeit wurde ein neuer Chargentrockner, mit diagonalem Luftstömungskanal entlang der Länge des Trocknungsraumes und ohne Leitbleche entwickelt. Neben dem unbestreitbaren Nutzen der Verwendung von Leitblechen, erhöhen diese jedoch die Konstruktionskosten und führen auch zu einer Erhöhung des Druckverlustes. Dadurch wird im Trocknungsprozess mehr Energie verbraucht. Um eine räumlich gleichmäßige Trocknung ohne Leitbleche zu erreichen, wurden die Lebensmittelbehälter diagonal entlang der Länge des Trockners platziert. Das vorrangige Ziel des diagonalen Kanals war, die einströmende, warme Luft gleichmäßig auf das gesamte Produkt auszurichten. Die Simulation des Luftstroms wurde mit ANSYS-Fluent in der ANSYS Workbench Plattform durchgeführt. Zwei verschiedene Geometrien der Trocknungskammer, diagonal und nicht diagonal, wurden modelliert und die Ergebnisse für eine gleichmäßige Luftverteilung aus dem diagonalen Luftströmungsdesign erhalten. Es wurde eine Reihe von Experimenten durchgeführt, um das Design zu bewerten. Kartoffelscheiben dienten als Trocknungsgut. Die statistischen Ergebnisse zeigen einen guten Korrelationskoeffizienten für die Luftstromverteilung (87,09%) zwischen dem durchschnittlich vorhergesagten und der durchschnittlichen gemessenen Strömungsgeschwindigkeit. Um den Effekt der gleichmäßigen Luftverteilung auf die Veränderung der Qualität zu bewerten, wurde die Farbe des Produktes, entlang der gesamten Länge der Trocknungskammer kontaktfrei im on-line-Verfahren bestimmt. Zu diesem Zweck wurde eine Imaging-Box, bestehend aus Kamera und Beleuchtung entwickelt. Räumliche Unterschiede dieses Qualitätsparameters wurden als Kriterium gewählt, um die gleichmäßige Trocknungsqualität in der Trocknungskammer zu bewerten. Entscheidend beim Lebensmittel-Chargentrockner ist sein Energieverbrauch. Dafür wurden thermodynamische Analysen des Trockners durchgeführt. Die Energieeffizienz des Systems wurde unter den gewählten Trocknungsbedingungen mit 50,16% kalkuliert. Die durchschnittlich genutzten Energie in Form von Elektrizität zur Herstellung von 1kg getrockneter Kartoffeln wurde mit weniger als 16,24 MJ/kg und weniger als 4,78 MJ/kg Wasser zum verdampfen bei einer sehr hohen Temperatur von jeweils 65°C und Scheibendicken von 5mm kalkuliert. Die Energie- und Exergieanalysen für diagonale Chargentrockner wurden zudem mit denen anderer Chargentrockner verglichen. Die Auswahl von Trocknungstemperatur, Massenflussrate der Trocknungsluft, Trocknerkapazität und Heiztyp sind die wichtigen Parameter zur Bewertung der genutzten Energie von Chargentrocknern. Die Entwicklung des diagonalen Chargentrockners ist eine nützliche und effektive Möglichkeit um dei Trocknungshomogenität zu erhöhen. Das Design erlaubt es, das gesamte Produkt in der Trocknungskammer gleichmäßigen Luftverhältnissen auszusetzen, statt die Luft von einer Horde zur nächsten zu leiten.