996 resultados para DAS-ELISA


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An ELISA Inhibition Method (EIM) was proposed for the serologic diagnosis of dengue, comparing its results with the Hemagglutination Inhibition (HI) and the IgM capture-ELISA (MAC-ELISA). Advantages and disadvantages of both methods are discussed according to sensitivity, specificity, performance and usefulness. As a conclusion we recommend the complementary inclusion of the EIM and MAC-ELISA substituting the HI for laboratories engaged in the diagnosis and surveillance of dengue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dacron (polyethylenetherephthalate) is proposed as a matrix for dot-ELISA procedures, as an alternative to nitrocellulose. Plates of dacron were partially hydrazinolyzed and hydrazide groups introduced were converted to azide groups. The derivative dacron-antigen was covalently linked on to the plates through these azide groups. The derivative dacron-antigen was exaustively washed according to CROOK and antigen was still fixed onto the plates. Protein F1A purified from Yersinia pestis was used as a model. Triration of sera from immunized and non immunized rabbits against this protein was carried out by employing the dot-ELISA method. No significant difference was observed using dacron-antigen and nitrocellulose-antigen preparations. However, both procedures showed to have a significant better performance in comparasion with the passive hemagglutination method. The specificity and reproductibility of the dot-ELISA assay using both preparations showed a similar behaviour. Nitrocellulose preparation was stable at 4ºC, 28ºC and -20ºC for 90 days, whereas the dacron-antigen derivative was stable only when stored at 4ºC. Dacron-antigen derivative could be re-used when the spot developing was proceeded using 4-chloro-1-naphtol as substrate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dot enzyme linked immunosorbent assay (dot-ELISA) was previously developed to detect specific antibodies in rabbits sera immunized against FIA protein obtained from Yersina pestis. This antigen was covalently linked onto the surface of dacron (polyethyleneterephthalate). Here, standard conditions are described for the optimization of this procedure: an amount of 20 ng of FIA protein was fixed onto dacron; anti-rabbit IgG peroxidase conjugate diluted 1:8,000 and 30% non-fat instant milk as blocking substance were used throughout the method. This procedure was compared with that employing nitrocellulose as solid-phase which showed to be more sensitive. However, the method based on dacron did not show false positive reactions against non-immunized rabbits sera at low antigen amount and diluted anti-IgG peroxidase conjugate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We herein present an improved assay for detecting the presence of Trypanosoma cruzi in infected cultures. Using chagasic human sera (CHS), we were able to detect T. cruzi infection in primary cultures of both peritoneal macrophages and heart muscle cells (MHC). To avoid elevated background levels - hitherto observed in all experiments especially in those using HMC - CHS were preincubated with uninfected cells in monolayers or suspensions prior to being used for detection of T. cruzi in infected monolayers. Preincubation with cell suspensions gave better results than with monolayers, reducing background by up to three times and increasing sensitivity by to twenty times. In addition, the continous fibroplastic cell line L929 was shown to be suitable for preadsorption of CHS. These results indicate that the high background levels observed in previous reports may be due to the presence of human autoantibodies that recognize surface and/or extracellular matrix components in cell monolayers. We therefore propose a modified procedure that increases the performance of the ELISA method, making it an useful tool even in cultures that would otherwise be expected to present low levels of infection or high levels of background

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An ELISA test for the serological diagnosisof amoebic liver abscess (ALA) was standardized and evaluated in sera from three groups of patients: (1) three patients with diagnosis confirmed by isolation of the parasite,(2) thirty seven patients with diagnosis established by clinical findings and ultrasound studies and (3) seven patients whose diagnosis were established by clinical findings and a positive double immunodifusion test. Ninety one serum samples from healthy subjects and 22 from patients with other liver or parasitic diseases were also included in the study. the optimum concentration of Entamoeba histolytica antigen was 1.25 µg/ml and optimum dilutions of serum and anti-human IgG-alkaline phosphatase conjugate were 1:400 and 1:4000 respectively. The cut-off point of the ELISA test in this study was an absorbance value of 0.34. The test parameters were: sensitivity = 95.7 per cent, specificty = 100 per cent, positive predictive value = 100 per cent and negative predictive value = 98.2 per cent.The ELISA test was found to be of great use as a diagnostic tool for the establishment of amoebic etiology in patients with clinical supposition of ALA. The test could also be used for seroepidemiological surveys of the prevalence of invasive amoebiasis in a given population, since it allows the processing of a greater number of samples at a lower cost tahn other serological tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive method for quantifying mouse plasma alpha-macroglobulins (AM) using an inhibition ELISA is described. AM are important plasmaproteinase inhibitors that possibly act also as immunomodulatory molecules. The standard protocol develope in our experiments involves coating well with 10 µg/ml A2M in carbonate buffer, followed by incubation with a 1:1 (v/v) mixture of the plasma to be tested (diluted 1/1000) and goat anti-AM (diluted 1/1250). This is followed by further incubation, first with the enzyme-conjugated antibody and with the substrate prior to the reading of absorbance levels of the reaction products. Standard curve samples must be included in each plate, employing known amounts of the purified Murine Alpha-2-Macroglobulin (MuA2M) used for coating, with concentrations ranging from 0.001 to 10 µg/ml. Using test samples in triplicates and a 6-point standard curve in a single ELISA plate, 25 plasma samples can be tested accurately. The method offers an useful tool for establishing AM levelsin small samples of mouse plasma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Discs of polyvinyl alcohol cross-linked with glutaraldehyde were synthesized under acid catalysis (H2SO4). Then, the antigen F1 purified from Yersinia pestis was covalently linked to this modified polymer. Afterwards, an enzyme-linked immunosorbent assay (ELISA) was established for the diagnosis of plague in rabbit and human. The best conditions for the method were achieved by using 1.3 ¼g of F1 prepared in 0.067 M phosphate buffer, pH 7.2, containing 1 M NaCl (PBS); anti-IgG peroxidase conjugate diluted 6,000 times and as a blocking agent 3% w/v skim milk in PBS. The titration of positive rabbit serum according to this procedure detected antibody concentrations up to 1:12,800 times. The present method, the conventional ELISA and passive haemagglutination assay are compared.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The high sensitivity and the possibility of automation of the enzyme-linked-immunosorbent-assay (ELISA) has indicated this technique as one of the most useful serological test for epidemiological studies. In the present study, an ELISA for detection of IgG antibodies against adult worm antigens (IgG-ELISA) was investigated for epidemiological purposes, in a rural area of the municipality of Itariri (São Paulo, Brazil). Blood on filter paper (1,180 samples) from about 650 schoolchildren were submitted to ELISA and the data compared to the results of the parasitological method of Kato-Katz and also to the IgM-IFT (immunofluorescence test for IgM antibodies to gut associated antigens). The prevalence rates respectively of 8.5%, 43.0%, and 56.2% by the Kato-Katz, IgG-ELISA, and IgM-IFT methods suggest the poor sensitivity of the parasitological method for detection of Schistosoma mansoni eggs in individuals with low worm burden, situation commonly observed in low endemic areas. These results can partially explain the poor degree of agreement between the IgG-ELISA and the Kato-Katz, as suggested by the Kappa index of 0.170. Otherwise, the Kappa index of 0.675 showed substantial agreement between the two serological tests. Some discrepancy of results between the two serological techniques must be better investigated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Antigen from Yersinia pestis was adsorbed on cellulose acetate discs (0.5 cm of diameter) which were obtained from dialysis membrane by using a paper punch. ELISA for human plague diagnosis was carried out employing this matrix and was capable to detect amount of 1.3 µg of antigen, 3,200 times diluted positive serum using human anti-IgG conjugate diluted 1:4,000. No relevant antigen lixiviation from the cellulose acetate was observed even after washing the discs 15 times. The discs were impregnated by the coloured products from the ELISA development allowing its use in dot-ELISA. Furthermore, cellulose acetate showed a better performance than the conventional PVC plates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The identification of arthropod bloodmeals is important in many epidemiological studies, as, the understanding of the life cycle of vectors and the patogens they transmit, as well as helping to define arthropods' control strategies. The precipitin test has been used for decades, but ELISA is slowly becoming more popular. To compare the two tests for sensitivity, specificity and accuracy to detect small insect bloodmeals, Aedes aegypti or Ae. fluviatilis mosquitoes were fed either on feline, canine or human hosts. Mosquitoes were frozen at 6, 12, 24, 48 or 72 h after feeding. Precipitin test showed better specificity and accuracy and ELISA test showed higher sensitivity. Better results with both tests were achieved when mosquitoes were frozen within 48 h from feeding.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to improve the specificity and sensitivity of the techniques for the human anisakidosis diagnosis, a method of affinity chromatography for the purification of species-specific antigens from Anisakis simplex third-stage larvae (L3) has been developed. New Zealand rabbits were immunized with A. simplex or Ascaris suum antigens or inoculated with Toxocara canis embryonated eggs. The IgG specific antibodies were isolated by means of protein A-Sepharose CL-4B beads columns. IgG anti-A. simplex and -A. suum were coupled to CNBr-activated Sepharose 4B. For the purification of the larval A. simplex antigens, these were loaded into the anti-A. simplex column and bound antigens eluted. For the elimination of the epitopes responsible for the cross-reactions, the A. simplex specific proteins were loaded into the anti-A. suum column. To prove the specificity of the isolated proteins, immunochemical analyses by polyacrylamide gel electrophoresis were carried out. Further, we studied the different responses by ELISA to the different antigenic preparations of A. simplex used, observing their capability of discriminating among the different antisera raised in rabbits (anti-A. simplex, anti-A. suum, anti-T. canis). The discriminatory capability with the anti-T. canis antisera was good using the larval A. simplex crude extract (CE) antigen. When larval A. simplex CE antigen was loaded into a CNBr-activated Sepharose 4B coupled to IgG from rabbits immunized with A. simplex CE antigen, its capability for discriminate between A. simplex and A. suum was improved, increasing in the case of T. canis. The best results were obtained using larval A. simplex CE antigen loaded into a CNBr-activated Sepharose 4B coupled to IgG from rabbits immunized with adult A. suum CE antigen. When we compared the different serum dilution and antigenic concentration, we selected the working serum dilution of 1/400 and 1 µg/ml of antigenic concentration.