953 resultados para CsI(Tl)-detector


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we consider robust joint designs of relay precoder and destination receive filters in a nonregenerative multiple-input multiple-output (MIMO) relay network. The network consists of multiple source-destination node pairs assisted by a MIMO-relay node. The channel state information (CSI) available at the relay node is assumed to be imperfect. We consider robust designs for two models of CSI error. The first model is a stochastic error (SE) model, where the probability distribution of the CSI error is Gaussian. This model is applicable when the imperfect CSI is mainly due to errors in channel estimation. For this model, we propose robust minimum sum mean square error (SMSE), MSE-balancing, and relay transmit power minimizing precoder designs. The next model for the CSI error is a norm-bounded error (NBE) model, where the CSI error can be specified by an uncertainty set. This model is applicable when the CSI error is dominated by quantization errors. In this case, we adopt a worst-case design approach. For this model, we propose a robust precoder design that minimizes total relay transmit power under constraints on MSEs at the destination nodes. We show that the proposed robust design problems can be reformulated as convex optimization problems that can be solved efficiently using interior-point methods. We demonstrate the robust performance of the proposed design through simulations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Till date load-commutated inverter (LCI)-fed synchronous motor drive configuration is popular in high power applications (>10 MW). The leading power factor operation of synchronous motor by excitation control offers this simple and rugged drive structure. On the contrary, LCI-fed induction motor drive is absent as it always draws lagging power factor current. Therefore, complicated commutation circuit is required to switch off thyristors for a current source inverter (CSI)-driven induction motor. It poses the major hindrance to scale up the power rating of CSI-fed induction motor drive. Anew power topology for LCI-fed induction motor drive for medium-voltage drive application is proposed. A new induction machine (active-reactive induction machine) with two sets of three-phase winding is introduced as a drive motor. The proposed power configuration ensures sinusoidal voltage and current at the motor terminals. The total drive power is shared among a thyristor-based LCI, an insulated gate bipolar transistor (IGBT)-based two-level voltage source inverter (VSI), and a three-level VSI. The benefits of SCRs and IGBTs are explored in the proposed drive. Experimental results from a prototype drive verify the basic concepts of the drive.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the method of field orientation of the stator current vector with respect to the stator, mutual, and rotor flux vectors, for the control of an induction motor fed from a current source inverter (CSI). A control scheme using this principle is described for orienting the stator current with respect to the rotor flux, as this gives natural decoupling between the current coordinates. A dedicated micro-computer system developed for implementing this scheme has been described. The experimental results are also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the design and performance analysis of a detector based on suprathreshold stochastic resonance (SSR) for the detection of deterministic signals in heavy-tailed non-Gaussian noise. The detector consists of a matched filter preceded by an SSR system which acts as a preprocessor. The SSR system is composed of an array of 2-level quantizers with independent and identically distributed (i.i.d) noise added to the input of each quantizer. The standard deviation sigma of quantizer noise is chosen to maximize the detection probability for a given false alarm probability. In the case of a weak signal, the optimum sigma also minimizes the mean-square difference between the output of the quantizer array and the output of the nonlinear transformation of the locally optimum detector. The optimum sigma depends only on the probability density functions (pdfs) of input noise and quantizer noise for weak signals, and also on the signal amplitude and the false alarm probability for non-weak signals. Improvement in detector performance stems primarily from quantization and to a lesser extent from the optimization of quantizer noise. For most input noise pdfs, the performance of the SSR detector is very close to that of the optimum detector. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Photo-thermal Deflection (PTD) technique is used to investigate the thermal diffusivity (alpha) of Ge17Te83 - xTlx (0 <= x <= 13) glasses as a function of composition. The thermal diffusivity of these glasses is found to lie in the range 0.020 to 0.048 cm(2)/s, which is consistent with the memory type of electrical switching exhibited by these samples. Further, it is found that alpha shows an initial increase with Tl addition, followed by a decrease. The observed composition dependence of thermal diffusivity has been understood on the basis that the thallium atoms are incorporated as a covalent species for lower values of x, increasing the network rigidity; however, they enter as ionic species for higher x values, fragmenting the network. The initial increase in a is due to the increasing network rigidity and the subsequent decrease is because of the fragmentation of the network. Also, there is a strong correlation between the composition dependence of switching voltages observed earlier and the variation with composition of electrical resistivity and thermal diffusivity of Ge17Te83 - xTlx glasses obtained in the present study. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we evaluate secrecy rates in cooperative relay beamforming in the presence of imperfect channel state information (CSI) and multiple eavesdroppers. A source-destination pair aided by.. out of.. relays, 1 <= k <= M, using decode-and-forward relay beamforming is considered. We compute the worst case secrecy rate with imperfect CSI in the presence of multiple eavesdroppers, where the number of eavesdroppers can be more than the number of relays. We solve the optimization problem for all possible relay combinations to find the secrecy rate and optimum source and relay weights subject to a total power constraint. We relax the rank-1 constraint on the complex semi-definite relay weight matrix and use S-procedure to reformulate the optimization problem that can be solved using convex semi-definite programming.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Herein we report the first applications of TCNQ as a rapid and highly sensitive off-the-shelf cyanide detector. As a proof-of-concept, we have applied a kinetically selective single-electron transfer (SET) from cyanide to deep-lying LUMO orbitals of TCNQ to generate a persistently stable radical anion (TCNQ(center dot-)), under ambient condition. In contrast to the known cyanide sensors that operate with limited signal outputs, TCNQ(center dot-) offers a unique multiple signaling platform. The signal readability is facilitated through multichannel absorption in the UV-vis-NIR region and scattering-based spectroscopic methods like Raman spectroscopy and hyper Rayleigh scattering techniques. Particularly notable is the application of the intense 840 nm NIR absorption band to detect cyanide. This can be useful for avoiding background interference in the UV-vis region predominant in biological samples. We also demonstrate the fabrication of a practical electronic device with TCNQ as a detector. The device generates multiorder enhancement in current with cyanide because of the formation of the conductive TCNQ(center dot-).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider a two user fading Multiple Access Channel with a wire-tapper (MAC-WT) where the transmitter has the channel state information (CSI) to the intended receiver but not to the eavesdropper (eve). We provide an achievable secrecy sum-rate with optimal power control. We next provide a secrecy sum-rate with optimal power control and cooperative jamming (CJ). We then study an achievable secrecy sum rate by employing an ON/OFF power control scheme which is more easily computable. We also employ CJ over this power control scheme. Results show that CJ boosts the secrecy sum-rate significantly even if we do not know the CSI of the eve's channel. At high SNR, the secrecy sum-rate (with CJ) without CSI of the eve exceeds the secrecy sum-rate (without CJ) with full CSI of the eve.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The variation of electrical resistivity in the system of glasses Ge17Te83-xTlx, with (1 <= x <= 13), has been studied as a function of high pressure for pressures up to 10 GPa. It is found that the normalized electrical resistivity decreases continuously with the increase in pressure and shows a sudden drop at a particular pressure (transition pressure), indicating the presence of a transition from semiconductor to near-metallic at these pressures which are in the range 3.0-5.0 GPa. This transition pressure is seen to decrease with the increase in the percentage content of thallium due to increasing metallicity of the thallium. The transition is reversible under application of pressure and X-ray diffraction of samples recovered after pressurization show that they remain amorphous after undergoing a pressurization decompression cycle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The detection efficiency of a gaseous photomultiplier depends on the photocathode quantum efficiency and the extraction efficiency of photoelectrons into the gas. In this paper we have studied the performance of an UV photon detector with P10 gas in which the extraction efficiency can reach values near to those in vacuum operated devices. Simulations have been done to compare the percentage of photoelectrons backscattered in P10 gas as well as in the widely used neon-based gas mixture. The performance study has been carried out using a single stage thick gas electron multiplier (THGEM). The electron pulses and electron spectrum are recorded under various operating conditions. Secondary effects prevailing in UV photon detectors like photon feedback are discussed and its effect on the electron spectrum under different operating conditions is analyzed. (C) 2014 Chinese Laser Press

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we consider the problem of power allocation in MIMO wiretap channel for secrecy in the presence of multiple eavesdroppers. Perfect knowledge of the destination channel state information (CSI) and only the statistical knowledge of the eavesdroppers CSI are assumed. We first consider the MIMO wiretap channel with Gaussian input. Using Jensen's inequality, we transform the secrecy rate max-min optimization problem to a single maximization problem. We use generalized singular value decomposition and transform the problem to a concave maximization problem which maximizes the sum secrecy rate of scalar wiretap channels subject to linear constraints on the transmit covariance matrix. We then consider the MIMO wiretap channel with finite-alphabet input. We show that the transmit covariance matrix obtained for the case of Gaussian input, when used in the MIMO wiretap channel with finite-alphabet input, can lead to zero secrecy rate at high transmit powers. We then propose a power allocation scheme with an additional power constraint which alleviates this secrecy rate loss problem, and gives non-zero secrecy rates at high transmit powers.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new dual simultaneous detector was developed for capillary electrophoresis microchip. Confocal laser-induced fluorescence (LIF) and moveable contactless conductivity detection (MCCD) were combined together for the first time. The two detection systems shared a common detection cell and could respond simultaneously. They were mutually independent and advantageous in analyses of mixtures containing organic and inorganic ions. The confocal LIF had high sensitivity and the MCCD could move along the separation channel and detect in different positions of the channel. The detection conditions of the dual detector were optimized. Rhodamine B was used to evaluate the performance of the dual detector. The limit of detection of the confocal LIF was < 5 nM, and that of the MCCD was 0.1 mu M. The dual detector had highly sensitivity and could offer response easily, rapidly and simultaneously.