920 resultados para Counter terrorism
Resumo:
A joint project between the Paul Scherrer Institut (PSI) and the Institute of Radiation Physics was initiated to characterise the PSI whole body counter in detail through measurements and Monte Carlo simulation. Accurate knowledge of the detector geometry is essential for reliable simulations of human body phantoms filled with known activity concentrations. Unfortunately, the technical drawings provided by the manufacturer are often not detailed enough and sometimes the specifications do not agree with the actual set-up. Therefore, the exact detector geometry and the position of the detector crystal inside the housing were determined through radiographic images. X-rays were used to analyse the structure of the detector, and (60)Co radiography was employed to measure the core of the germanium crystal. Moreover, the precise axial alignment of the detector within its housing was determined through a series of radiographic images with different incident angles. The hence obtained information enables us to optimise the Monte Carlo geometry model and to perform much more accurate and reliable simulations.
Resumo:
Cet article décrit, à l'intention des mdéecins de rpremier recours, les principes de base d'une action de secours lors d'un attentat (ou d'un accident) chimique impliquant de nombreuses victimes intoxiquées et/ou contaminées.
Resumo:
Työn tavoitteena oli selvittää, miten eri parametrit vaikuttavat monilankaisen verrannollisuuslaskurin laskennallisiin ominaisuuksiin sekä voidaanko suurikokoista monilankaverrannollisuuslaskuria käyttää tehokkaasti suurien pintojen ? - ja ?- kontaminaation mittaamiseen. Ensin selvitettiin EU:n nykyistä clearing-käytäntöä sekä hahmoteltiin tulevia materiaalivirtoja, esiteltiin verrannollisuuslaskurin ja sen monilankamallin toimintaperiaate sekä käytettävien materiaalien ominaisuudet. Kootun teorian pohjalta selvitettiin tärkeimpien parametrien vaikutus ilmaisimen laskennallisiin ominaisuuksiin. Lopuksi suoritettiin rakenteilla olevan monilankaverrannollisuuslaskurin alustava testaus. Tulevien vuosien aikana eri puolilla maailmaa suljettavat erityyppiset ydinlaitokset luovat suuren tarpeen tehokkaiden kontaminaatiomittauslaitteistojen kehittämiselle. Tällä hetkellä mittaukset suoritetaan lähinnä noin 1 dm2 käsi-instrumentein, joten suurikokoinen, automatisoitu mittauslaitteisto sekä tehostaisi mittausprosessia suuresti sekä säästäisi runsaasti miestyötunteja. Jatkotoimenpiteiksi ehdotetaan laitteiston jatkotestausta, liikkeen ja nopeuden testausta sekä lopulta paikkaherkkyystoiminnon toteuttamisperiaatteen valintaa ja testausta.
Resumo:
We present a dual-trap optical tweezers setup which directly measures forces using linear momentum conservation. The setup uses a counter-propagating geometry, which allows momentum measurement on each beam separately. The experimental advantages of this setup include low drift due to all-optical manipulation, and a robust calibration (independent of the features of the trapped object or buffer medium) due to the force measurement method. Although this design does not attain the high-resolution of some co-propagating setups, we show that it can be used to perform different single molecule measurements: fluctuation-based molecular stiffness characterization at different forces and hopping experiments on molecular hairpins. Remarkably, in our setup it is possible to manipulate very short tethers (such as molecular hairpins with short handles) down to the limit where beads are almost in contact. The setup is used to illustrate a novel method for measuring the stiffness of optical traps and tethers on the basis of equilibrium force fluctuations, i.e., without the need of measuring the force vs molecular extension curve. This method is of general interest for dual trap optical tweezers setups and can be extended to setups which do not directly measure forces.
Resumo:
This paper examines argumentative talk-in-interaction in the workplace. It focuses on counter-argumentative references, which consist of the various resources that the opponent uses to refer to the origin/source of his/her opposition, namely the confronted position and the person who expressed it. Particular attention is paid to the relationship - in terms of sequential positioning and referential extension - between reported speech, polyphony, pointing gestures and shifts in gaze direction. Data are taken from workplace management meetings that have been recorded in New Zealand by the Language in the Workplace Project.
Resumo:
In this study the performance measurement, a part of the research and development of the RNC, was improved by implementing counter testing to the Nokia Automation System. The automation of counter testing is a feature the customer ordered, because performing counter testing manually is rather complex. The objective was to implement an automated counter testing system, which once configured correctly, would manage to run the testing and perform the analysis. The requirements for the counter testing were first studied. It was investigated if the auto-mation of the feature was feasible in the meetings with the customer. The basic functionality required for the automation was also drawn. The technologies used in the architecture of the Nokia Automation System were studied. Based on the results of the study, a new technology, wxWidgets, was introduced. The new technology was necessary to facilitate the implementing of the required feature. Finally the implementation of the counter testing was defined and implemented. The result of this study was the automation of the counter testing method developed as a new feature for the Nokia Automation System. The feature meets the specifications and requirements set by the customer. The performing of the counter testing feature is totally automated. Only configuration of the test cases is done by the user. The customer has presented new requests to further develop the feature and there are plans by the Nokia Automation System developers to implement those in the near future. The study describes the implementation of the counter testing feature introduced. The results of the study give guidelines for further developing the feature.
Resumo:
The main objective of this thesis was to compare the efficiency of counter-current and co-current filter cake washing techniques. Filter cake washing is a common unit operation which is used in the chemical process industry for improving the recovery of the liquid phase or for purifying the solid phase of the filter cake. Counter-current displacement washing is more difficult to arrange and it requires additional process equipment but the advantage of counter-current method is that the consumption of wash water that is required for achieving certain filter cake purity may be considerably decreased when compared to the co-current washing method. This is true especially for materials that are difficult to wash. The literature part of this thesis consists of a review of filter cake washing in general, including the basic principles of co-current and counter-current techniques, and a description of the structure and operation of a horizontal vacuum belt filter, which is the equipment considered in the experimental part of this thesis. Also the most common cake washing models are introduced. The experiments were performed by washing wheat apatite filter cakes in a laboratory scale vacuum filter by using both co-current and counter-current washing methods. The main results of these tests were the washing curves that relate the purity of the filter cake to the amount of wash liquid used. Comparison between the obtained washing curves showed that both washing methods could be efficiently applied for achieving good washing results. The differences between the wash liquid consumptions in the co-current and counter-current washing methods were found to be surprisingly small but this is most probably explained by the relatively good washing characteristics of the apatite cakes. The washing models introduced in the literature part were compared with the results obtained from the experiments and it was found out that the studied cake washing processes could be described
Resumo:
High-speed counter-current chromatography (HSCCC) is a major tool for the fast separation of natural products from plants. It was used for the preparative isolation of the flavonoid monoglucosides present in the aerial parts of the Davilla elliptica St. Hill. (Dilleniaceae). This species is used in Brazilian folk medicine for the treatment of gastric disorders. The optimum solvent system used was composed of a mixture of ethyl acetate-n-propanol-water (140:8:80, v/v/v) and led to a successful separation of quercetin-3-O-alpha-L-rhamnopyranoside and myricetin-3-O-alpha-L-rhamnopyranoside in approximately 3.0 hours with purity higher than 95%. Identification was performed by ¹H NMR, 13C NMR and HPLC-UV-DAD analyses.
Resumo:
Preparative high-speed counter-current chromatography (HSCCC) was successfully applied for separation and purification of sesquiterpenoids from an extract of Tussilago farfara L. with a two-phase solvent system composed of n-hexane-ethyl acetate- methanol-water (1:0.5:1.1:0.3, v/v/v/v). The separation produced a total of 32 mg of tussilagone, 18 mg of 14-acetoxy-7β-(3'-ethyl cis-crotonoyloxy)-lα-(2'-methyl butyryloxy)-notonipetranone and 21 mg of 7β-(3'-ethyl cis-crotonoyloxy)-lα-(2'- methyl butyryloxy)-3,14-dehydro-Z-notonipetranone from 500 mg of the crude extract in one step separation with the purity of 99.5, 99.4 and 99.1%, respectively, as determined by HPLC. The structures of these compounds were identified by ESI-MS, ¹H-NMR and 13C-NMR.
Resumo:
Supercritical fluid extraction was used to extract active compounds from the Chinese traditional medicinal D. dasycarpus under the pressure of 30 MPa and temperature of 45 ºC. Further separation and purification was established by high-speed counter-current chromatography (HSCCC) with a two-phase solvent system composed of n-hexane-ethyl acetate-methanol-water (1:0.8:1.3:0.9, volume ratio). The separation yielded a total of 47 mg of dictamnine, 24 mg of obacunone and 83 mg of fraxinellone from 1.0 g of the crude extract in one step separation with the purity of 99.2, 98.4 and 99.0%, respectively, as determined by HPLC. The chemical structures of these compounds were identified by ESI-MS, IR, ¹H-NMR and 13C-NMR.
Resumo:
Eight bufadienolides were successfully isolated and purified from ChanSu by high-speed counter-current chromatography (HSCCC) combined with preparative HPLC (prep-HPLC). First, a stepwise elution mode of HSCCC with the solvent system composed of petroleum ether - ethyl acetate - methanol - water (4:6:4:6, 4:6:5:5, v/v) was employed and four bufadienolides, two partially purified fractions were obtained from 200 mg of crude extract. The partially purified fractions III and VI were then further separated by prep-HPLC, respectively, and another four bufadienolides were recovered. Their structures were confirmed by ESI-MS and ¹H-NMR spectra.
Resumo:
An efficient method for the rapid separation and purification of polyphenols from artichoke by polyamide column chromatography in combination with high-speed counter-current chromatography (HSCCC) was successfully built. The crude ethanol extracts from dry artichoke were first pre-separated by polyamide column chromatography and divided in two parts as sample 1 and sample 2. Then, the samples were further separated by HSCCC and yielded 7.8 mg of chlorogenic acid (compound I), 24.5 mg of luteolin-7-O-β-D-rutinoside (compound II), 18.4 mg of luteolin-7-O-β-D-glucoside (compound III), and 33.4 mg of cynarin (compound IV) with purity levels of 92.0%, 98.2%, 98.5%, and 98.0%, respectively, as determined by high-performance liquid chromatography (HPLC) method. The chemical structures of these compounds were identified by electrospray ionization-mass spectrometry (ESI-MS) and nuclear magnetic resonance (NMR).
Resumo:
The technique of pH-zone-refining counter-current chromatography was successfully applied to preparatively separate three C19-diterpenoid alkaloids from the crude extracts of Aconitum carmichaelii for the first time using a two-phase solvent system of petroleum ether-ethyl acetate-methanol-water (5:5:1:9, v/v/v/v). Mesaconitine (I), hypaconitine (II), and deoxyaconitine (III) were obtained from 2.5 g of the crude alkaloids in a one-step separation; the yields were 4.16%, 16.96%, and 5.05%, respectively. The purities of compounds I, II, and III were 93.0%, 95%, and 96%, respectively, as determined by HPLC. The chemical structures of the three compounds were identified by electrospray ionization mass spectrometry (ESI-MS) and NMR.
Resumo:
An effective method for the rapid separation and purification of three stilbenes from the radix of Polygonum cillinerve (Nakai) Ohwl by macroporous resin column chromatography combined with high-speed counter-current chromatography (HSCCC) was successfully established. In the present study, a two-phase solvent system composed of chloroform-n-butanol-methanol-water (4:1:4:2, v/v/v/v) was used for HSCCC separation. A one-step separation in 4 h from 150 mg of crude extract produced 26.3 mg of trans-resveratrol-3-O-glucoside, 42.0 mg of pieceid-2"-O-gallate, and 17.9 mg of trans-resveratrol with purities of 99.1%, 97.8%, and 99.4%, respectively, as determined by high-performance liquid chromatography (HPLC). The chemical structures of these compounds were identified by nuclear magnetic resonance (NMR) spectroscopy.