921 resultados para Cost and standard of living--New England--18th century
Resumo:
LiteSteel Beam (LSB) is a new cold-formed steel beam produced by OneSteel Australian Tube Mills. The new beam is effectively a channel section with two rectangular hollow flanges and a slender web, and is manufactured using a combined cold-forming and electric resistance welding process. OneSteel Australian Tube Mills is promoting the use of LSBs as flexural members in a range of applications, such as floor bearers. When LSBs are used as back to back built-up sections, they are likely to improve their moment capacity and thus extend their applications further. However, the structural behaviour of built-up beams is not well understood. Many steel design codes include guidelines for connecting two channels to form a built-up I-section including the required longitudinal spacing of connections. But these rules were found to be inadequate in some applications. Currently the safe spans of builtup beams are determined based on twice the moment capacity of a single section. Research has shown that these guidelines are conservative. Therefore large scale lateral buckling tests and advanced numerical analyses were undertaken to investigate the flexural behaviour of back to back LSBs connected by fasteners (bolts) at various longitudinal spacings under uniform moment conditions. In this research an experimental investigation was first undertaken to study the flexural behaviour of back to back LSBs including its buckling characteristics. This experimental study included tensile coupon tests, initial geometric imperfection measurements and lateral buckling tests. The initial geometric imperfection measurements taken on several back to back LSB specimens showed that the back to back bolting process is not likely to alter the imperfections, and the measured imperfections are well below the fabrication tolerance limits. Twelve large scale lateral buckling tests were conducted to investigate the behaviour of back to back built-up LSBs with various longitudinal fastener spacings under uniform moment conditions. Tests also included two single LSB specimens. Test results showed that the back to back LSBs gave higher moment capacities in comparison with single LSBs, and the fastener spacing influenced the ultimate moment capacities. As the fastener spacing was reduced the ultimate moment capacities of back to back LSBs increased. Finite element models of back to back LSBs with varying fastener spacings were then developed to conduct a detailed parametric study on the flexural behaviour of back to back built-up LSBs. Two finite element models were developed, namely experimental and ideal finite element models. The models included the complex contact behaviour between LSB web elements and intermittently fastened bolted connections along the web elements. They were validated by comparing their results with experimental results and numerical results obtained from an established buckling analysis program called THIN-WALL. These comparisons showed that the developed models could accurately predict both the elastic lateral distortional buckling moments and the non-linear ultimate moment capacities of back to back LSBs. Therefore the ideal finite element models incorporating ideal simply supported boundary conditions and uniform moment conditions were used in a detailed parametric study on the flexural behaviour of back to back LSB members. In the detailed parametric study, both elastic buckling and nonlinear analyses of back to back LSBs were conducted for 13 LSB sections with varying spans and fastener spacings. Finite element analysis results confirmed that the current design rules in AS/NZS 4600 (SA, 2005) are very conservative while the new design rules developed by Anapayan and Mahendran (2009a) for single LSB members were also found to be conservative. Thus new member capacity design rules were developed for back to back LSB members as a function of non-dimensional member slenderness. New empirical equations were also developed to aid in the calculation of elastic lateral distortional buckling moments of intermittently fastened back to back LSBs. Design guidelines were developed for the maximum fastener spacing of back to back LSBs in order to optimise the use of fasteners. A closer fastener spacing of span/6 was recommended for intermediate spans and some long spans where the influence of fastener spacing was found to be high. In the last phase of this research, a detailed investigation was conducted to investigate the potential use of different types of connections and stiffeners in improving the flexural strength of back to back LSB members. It was found that using transverse web stiffeners was the most cost-effective and simple strengthening method. It is recommended that web stiffeners are used at the supports and every third points within the span, and their thickness is in the range of 3 to 5 mm depending on the size of LSB section. The use of web stiffeners eliminated most of the lateral distortional buckling effects and hence improved the ultimate moment capacities. A suitable design equation was developed to calculate the elastic lateral buckling moments of back to back LSBs with the above recommended web stiffener configuration while the same design rules developed for unstiffened back to back LSBs were recommended to calculate the ultimate moment capacities.
Resumo:
Objectives: We sought to characterise the demographics, length of admission, final diagnoses, long-term outcome and costs associated with the population who presented to an Australian emergency department (ED) with symptoms of possible acute coronary syndrome (ACS). Design, setting and participants: Prospectively collected data on ED patients presenting with suspected ACS between November 2008 and February 2011 was used, including data on presentation and at 30 days after presentation. Information on patient disposition, length of stay and costs incurred was extracted from hospital administration records. Main outcome measures: Primary outcomes were mean and median cost and length of hospital stay. Secondary outcomes were diagnosis of ACS, other cardiovascular conditions or non-cardiovascular conditions within 30 days of presentation. Results: An ACS was diagnosed in 103 (11.1%) of the 926 patients recruited. 193 patients (20.8%) were diagnosed with other cardiovascular-related conditions and 622 patients (67.2%) had non-cardiac-related chest pain. ACS events occurred in 0 and 11 (1.9%) of the low-risk and intermediate-risk groups, respectively. Ninety-two (28.0%) of the 329 high-risk patients had an ACS event. Patients with a proven ACS, high-grade atrioventricular block, pulmonary embolism and other respiratory conditions had the longest length of stay. The mean cost was highest in the ACS group ($13 509; 95% CI, $11 794–$15 223) followed by other cardiovascular conditions ($7283; 95% CI, $6152–$8415) and non-cardiovascular conditions ($3331; 95% CI, $2976–$3685). Conclusions: Most ED patients with symptoms of possible ACS do not have a cardiac cause for their presentation. The current guideline-based process of assessment is lengthy, costly and consumes significant resources. Investigation of strategies to shorten this process or reduce the need for objective cardiac testing in patients at intermediate risk according to the National Heart Foundation and Cardiac Society of Australia and New Zealand guideline is required.
Resumo:
The INFORMAS food prices module proposes a step-wise framework to measure the cost and affordability of population diets. The price differential and the tax component of healthy and less healthy foods, food groups, meals and diets will be benchmarked and monitored over time. Results can be used to model or assess the impact of fiscal policies, such as ‘fat taxes’ or subsidies. Key methodological challenges include: defining healthy and less healthy foods, meals, diets and commonly consumed items; including costs of alcohol, takeaways, convenience foods and time; selecting the price metric; sampling frameworks; and standardizing collection and analysis protocols. The minimal approach uses three complementary methods to measure the price differential between pairs of healthy and less healthy foods. Specific challenges include choosing policy relevant pairs and defining an anchor for the lists. The expanded approach measures the cost of a healthy diet compared to the current (less healthy) diet for a reference household. It requires dietary principles to guide the development of the healthy diet pricing instrument and sufficient information about the population’s current intake to inform the current (less healthy) diet tool. The optimal approach includes measures of affordability and requires a standardised measure of household income that can be used for different countries. The feasibility of implementing the protocol in different countries is being tested in New Zealand, Australia and Fiji. The impact of different decision points to address challenges will be investigated in a systematic manner. We will present early insights and results from this work.
Resumo:
We propose a new method for design of computationally efficient nonsubsampled multiscale multidirectional filter bank with perfect reconstruction (PR). This filter bank is composed of two nonsubsampled filter banks, for multiscale decomposition and for directional expansion. For multiscale decomposition, we transform the 1-D equivalent subband filters directly into 2-D equivalent subband filters. The computational cost is considerably reduced by avoiding the computation of 2-D convolutions. The multidirectional decomposition utilizes fan filters. A new method for design of 2-D zero phase FIR fan filter transformation function is developed. This method also aids the transformation of a 1-D filter bank to a 2-D multidirectional filter bank. The potential application of the proposed filter bank is illustrated by comparing the image denoising performance of the proposed filter bank with other design method that exist in available literature.
Resumo:
A decline in the abundance of blackback flounders, together with the withdrawal of vessels from this fishery, has resulted in a lowered catch in recent years compared to the peak period 1928 through 1931. Data obtained from U. S. Fish and Wildlife Service Hatchery catch records and from fishermen's log book records show a drop in abundance of 63 per cent from the early 1930's to the present in the Boothbay Harbor region and of 31 to 40 per cent in the area south of Cape Cod. Information on the early life history and distribution of young blackback flounders and the size and age composition and distribution of fish subject to the commercial and sport fisheries indicates that the young are the product of local spawning and that the sport and commercial fisheries draw on a resident stock of primarily adult fish.
Resumo:
A new method for measuring the coefficient of friction between nonwoven materials and the curved surface of the volar forearm has been developed and validated. The method was used to measure the coefficient of static friction for three different nonwoven materials on the normal (dry) and over-hydrated volar forearms of five female volunteers (ages 18-44). The method proved simple to run and had good repeatability: the coefficient of variation (standard deviation expressed as a percentage of the mean) for triplets of repeat measurements was usually (80 per cent of the time) less than 10 per cent. Measurements involving the geometrically simpler configuration of pulling a weighted fabric sample horizontally across a quasi-planar area of volar forearm skin proved experimentally more difficult and had poorer repeatability. However, correlations between values of coefficient of static friction derived using the two methods were good (R = 0.81 for normal (dry) skin, and 0.91 for over-hydrated skin). Measurements of the coefficient of static friction for the three nonwovens for normal (dry) and for over-hydrated skin varied in the ranges of about 0.3-0.5 and 0.9-1.3, respectively. In agreement with Amontons' law, coefficients of friction were invariant with normal pressure over the entire experimental range (0.1-8.2 kPa).
Resumo:
Methods for determining cost-effectiveness of different treatments are well established, unlike appraisal of non-drug interventions, including novel diagnostics and biomarkers.
Resumo:
The Basic Income has been defined as a relatively small income that the public Administration unconditionally provides to all its members as a citizenship right. Its principal objective consists on guaranteeing the entire population with an income enough to satisfy living basic needs, but it could have other positive effects such as a more equally income redistribution or tax fraud fighting, as well as some drawbacks, like the labor supply disincentives. In this essay we present the argument in favor and against this policy and ultimately define how it could be financed according to the actual tax and social benefits’ system in Navarra. The research also approaches the main economic implications of the proposal, both in terms of static income redistribution and discusses other relevant dynamic uncertainties.
Resumo:
Medieval 'new towns' seem to echo Roman towns in having a grid of streets associated with a fortress, and have often been credited with a standard plan applied by the hand of authority. Here the authors analyse the new towns founded by Edward I in Wales and find some highly significant variations. Rediscovering the original layouts by high precision survey and GIS mapping, they show that some towns, founded at the same time and on similar topography, had quite different layouts, while others, founded at long intervals, had plans that were almost identical. Documentation hints at the explanation: it was the architects, masons and ditch-diggers, not the king and aristocracy, who established and developed these blueprints of urban life.
Resumo:
L’athérosclérose est une maladie qui cause, par l’accumulation de plaques lipidiques, le durcissement de la paroi des artères et le rétrécissement de la lumière. Ces lésions sont généralement localisées sur les segments artériels coronariens, carotidiens, aortiques, rénaux, digestifs et périphériques. En ce qui concerne l’atteinte périphérique, celle des membres inférieurs est particulièrement fréquente. En effet, la sévérité de ces lésions artérielles est souvent évaluée par le degré d’une sténose (réduction >50 % du diamètre de la lumière) en angiographie, imagerie par résonnance magnétique (IRM), tomodensitométrie ou échographie. Cependant, pour planifier une intervention chirurgicale, une représentation géométrique artérielle 3D est notamment préférable. Les méthodes d’imagerie par coupe (IRM et tomodensitométrie) sont très performantes pour générer une imagerie tridimensionnelle de bonne qualité mais leurs utilisations sont dispendieuses et invasives pour les patients. L’échographie 3D peut constituer une avenue très prometteuse en imagerie pour la localisation et la quantification des sténoses. Cette modalité d’imagerie offre des avantages distincts tels la commodité, des coûts peu élevés pour un diagnostic non invasif (sans irradiation ni agent de contraste néphrotoxique) et aussi l’option d’analyse en Doppler pour quantifier le flux sanguin. Étant donné que les robots médicaux ont déjà été utilisés avec succès en chirurgie et en orthopédie, notre équipe a conçu un nouveau système robotique d’échographie 3D pour détecter et quantifier les sténoses des membres inférieurs. Avec cette nouvelle technologie, un radiologue fait l’apprentissage manuel au robot d’un balayage échographique du vaisseau concerné. Par la suite, le robot répète à très haute précision la trajectoire apprise, contrôle simultanément le processus d’acquisition d’images échographiques à un pas d’échantillonnage constant et conserve de façon sécuritaire la force appliquée par la sonde sur la peau du patient. Par conséquent, la reconstruction d’une géométrie artérielle 3D des membres inférieurs à partir de ce système pourrait permettre une localisation et une quantification des sténoses à très grande fiabilité. L’objectif de ce projet de recherche consistait donc à valider et optimiser ce système robotisé d’imagerie échographique 3D. La fiabilité d’une géométrie reconstruite en 3D à partir d’un système référentiel robotique dépend beaucoup de la précision du positionnement et de la procédure de calibration. De ce fait, la précision pour le positionnement du bras robotique fut évaluée à travers son espace de travail avec un fantôme spécialement conçu pour simuler la configuration des artères des membres inférieurs (article 1 - chapitre 3). De plus, un fantôme de fils croisés en forme de Z a été conçu pour assurer une calibration précise du système robotique (article 2 - chapitre 4). Ces méthodes optimales ont été utilisées pour valider le système pour l’application clinique et trouver la transformation qui convertit les coordonnées de l’image échographique 2D dans le référentiel cartésien du bras robotisé. À partir de ces résultats, tout objet balayé par le système robotique peut être caractérisé pour une reconstruction 3D adéquate. Des fantômes vasculaires compatibles avec plusieurs modalités d’imagerie ont été utilisés pour simuler différentes représentations artérielles des membres inférieurs (article 2 - chapitre 4, article 3 - chapitre 5). La validation des géométries reconstruites a été effectuée à l`aide d`analyses comparatives. La précision pour localiser et quantifier les sténoses avec ce système robotisé d’imagerie échographique 3D a aussi été déterminée. Ces évaluations ont été réalisées in vivo pour percevoir le potentiel de l’utilisation d’un tel système en clinique (article 3- chapitre 5).
Body mass index as a standard of living measure: a different interpretation for the case of Colombia
Resumo:
We analyze the Body Mass Index (BMI) in a distinct way of its traditional use and it lets us use it as a proxy of standard of living for the case of Colombia. Our approach is focused on studying how far the people are from the normal range and not on the score of each one and this lets us to treat equally extreme cases as severe thinness and obesity. We use a probabilistic model (Ordered Probit) that evaluates the probability of being within the normal range or another level. We found that socioeconomic variables have a significant effect on the dependent variable and that there are no linear effects. Besides, people with difficulties for walking and adults have less probability of having a normal BMI.
Resumo:
The position of 125 countries is studied on the basis of a collection of 26 basic, health, economic and educational indicators. Multivariate statistical methods were used, including Cluster Analysis, Principal Component Analysis and Multivariate Analysis of Variance. The most discriminating variables were life expectancy the child mortality rate, the mortality rate of children of less than five years of age, the birth and fertility rates and the high-school female matriculation rate. The first principal component was interpreted as a measure of the living standard which made it possible to place the countries in order. Five clusters of countries are suggested.
Resumo:
EUMETSAT (www.eumetsat.int) e’ l’agenzia europea per operazioni su satelliti per monitorare clima, meteo e ambiente terrestre. Dal centro operativo situato a Darmstadt (Germania), si controllano satelliti meteorologici su orbite geostazionarie e polari che raccolgono dati per l’osservazione dell’atmosfera, degli oceani e della superficie terrestre per un servizio continuo di 24/7. Un sistema di monitoraggio centralizzato per programmi diversi all’interno dell’ambiente operazionale di EUMETSAT, e’ dato da GEMS (Generic Event Monitoring System). Il software garantisce il controllo di diverse piattaforme, cross-monitoring di diverse sezioni operative, ed ha le caratteristiche per potere essere esteso a future missioni. L’attuale versione della GEMS MMI (Multi Media Interface), v. 3.6, utilizza standard Java Server Pages (JSP) e fa uso pesante di codici Java; utilizza inoltre files ASCII per filtri e display dei dati. Conseguenza diretta e’ ad esempio, il fatto che le informazioni non sono automaticamente aggiornate, ma hanno bisogno di ricaricare la pagina. Ulteriori inputs per una nuova versione della GEMS MMI vengono da diversi comportamenti anomali riportati durante l’uso quotidiano del software. La tesi si concentra sulla definizione di nuovi requisiti per una nuova versione della GEMS MMI (v. 4.4) da parte della divisione ingegneristica e di manutenzione di operazioni di EUMETSAT. Per le attivita’ di supporto, i test sono stati condotti presso Solenix. Il nuovo software permettera’ una migliore applicazione web, con tempi di risposta piu’ rapidi, aggiornamento delle informazioni automatico, utilizzo totale del database di GEMS e le capacita’ di filtri, insieme ad applicazioni per telefoni cellulari per il supporto delle attivita’ di reperibilita’. La nuova versione di GEMS avra’ una nuova Graphical User Interface (GUI) che utilizza tecnologie moderne. Per un ambiente di operazioni come e’ quello di EUMETSAT, dove l’affidabilita’ delle tecnologie e la longevita’ dell’approccio scelto sono di vitale importanza, non tutti gli attuali strumenti a disposizione sono adatti e hanno bisogno di essere migliorati. Allo stesso tempo, un’ interfaccia moderna, in termini di visual design, interattivita’ e funzionalita’, e’ importante per la nuova GEMS MMI.
Resumo:
At the research reactor Forschungs-Neutronenquelle Heinz Maier-Leibnitz (FRM II) a new Prompt Gamma-ray Activation Analysis (PGAA) facility was installed. The instrument was originally built and operating at the spallation source at the Paul Scherrer Institute in Switzerland. After a careful re-design in 2004–2006, the new PGAA instrument was ready for operation at FRM II. In this paper the main characteristics and the current operation conditions of the facility are described. The neutron flux at the sample position can reach up 6.07×1010 [cm−2 s−1], thus the optimisation of some parameters, e.g. the beam background, was necessary in order to achieve a satisfactory analytical sensitivity for routine measurements. Once the optimal conditions were reached, detection limits and sensitivities for some elements, like for example H, B, C, Si, or Pb, were calculated and compared with other PGAA facilities. A standard reference material was also measured in order to show the reliability of the analysis under different conditions at this instrument.
Resumo:
Effective visual exploration is required for many activities of daily living and instruments to assess visual exploration are important for the evaluation of the visual and the oculomotor system. In this article, the development of a new instrument to measure central and peripheral target recognition is described. The measurement setup consists of a hemispherical projection which allows presenting images over a large area of ±90° horizontal and vertical angle. In a feasibility study with 14 younger (21–49 years) and 12 older (50–78 years) test persons, 132 targets and 24 distractors were presented within naturalistic color photographs of everyday scenes at 10°, 30°, and 50° eccentricity. After the experiment, both younger and older participants reported in a questionnaire that the task is easy to understand, fun and that it measures a competence that is relevant for activities of daily living. A main result of the pilot study was that younger participants recognized more targets with smaller reaction times than older participants. The group differences were most pronounced for peripheral target detection. This test is feasible and appropriate to assess the functional field of view in younger and older adults.