864 resultados para Coronary angiography


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction. The apical ballooning syndrome (ABS) is a single reversible cardiomyopathy often triggered by a stressful event. We aimed to present a case report regarding this disorder. Case presentation. Here we present the case of a 77-year-old female hypertensive patient, sedentary and non-smoker, diagnosed with apical ballooning syndrome. We describe the clinical signs and symptoms, changes in markers of myocardial necrosis and changes in the electrocardiogram and coronary angiography. Conclusion: The course of events patient showed clinical improvement with treatment and support was not necessary to administer specific medications or interventions to reverse the situation. After hemodynamic stabilization coronary angiography showed no obstructive lesions and left ventricle with akinesia of the apex and the middle portion of the left ventricle. © 2013 do Nascimento et al.; licensee BioMed Central Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

FUNDAMENTO: A redução da frequência cardíaca (FC) na angiografia por tomografia das artérias coronarianas (ATCCor) é fundamental para a qualidade de imagem. A eficácia dos bloqueadores de cálcio como alternativas para pacientes com contraindicações aos betabloqueadores não foi definida. OBJETIVOS: Comparar a eficácia na redução da FC e variabilidade RR do metoprolol e diltiazem na ATCCor. MÉTODOS: Estudo prospectivo, randomizado, aberto, incluiu pacientes com indicação clínica de ATCCor, em ritmo sinusal, com FC>70bpm e sem uso de agentes que interferissem com a FC. Cinquenta pacientes foram randomizados para grupos: metoprolol IV 5-15 mg ou até FC≤60 bpm(M), e diltiazem IV 0,25-0,60mg/kg ou até FC≤60 bpm (D). Pressão arterial (PA) e FC foram aferidas na condição basal, 1min, 3min e 5min após agentes, na aquisição e após ATCCor. RESULTADOS: A redução da FC em valores absolutos foi maior no grupo M que no grupo D (1, 3, 5min, aquisição e pós-exame). A redução percentual da FC foi significativamente maior no grupo M apenas no 1 min e 3 min após início dos agentes. Não houve diferença no 5 min, durante a aquisição e após exame. A variabilidade RR percentual do grupo D foi estatisticamente menor do que a do grupo M durante a aquisição (variabilidade RR/ FC média da aquisição). Um único caso de BAV, 2:1 Mobitz I, revertido espontaneamente ocorreu (grupo D). CONCLUSÃO: Concluímos que o diltiazem é uma alternativa eficaz e segura aos betabloqueadores na redução da FC na realização de angiografia por tomografia computadorizada das artérias coronarianas. (Arq Bras Cardiol. 2012; [online].ahead print, PP.0-0)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: A recent study investigated the MYLIP region in the Mexican population in order to fine-map the actual susceptibility variants of this locus. The p.N342S polymorphism was identified as the underlying functional variant accounting for one of the previous signals of genome-wide association studies and the N342 allele was associated with higher cholesterol concentrations in Mexican dyslipidemic individuals. To date, there is no further evaluation on this genotype-phenotype association in the literature. In this scenario, and because of a possible pharmacotherapeutic target of dyslipidemia, the main aim of this study was to assess the influence of the MYLIP p.N342S polymorphism on lipid profile in Brazilian individuals. Methods: 1295 subjects of the general population and 1425 consecutive patients submitted to coronary angiography were selected. General characteristics, biochemical tests, blood pressures, pulse wave velocity, and coronary artery disease scores were analyzed. Genotypes for the MYLIP rs9370867 (p.N342S, c.G1025A) polymorphism were detected by high resolution melting analysis. Results: No association of the MYLIP rs9370867 genotypes with lipid profile, hemodynamic data, and coronary angiographic data was found. Analysis stratified by hyperlipidemia, gender, and ethnicity was also performed and the sub-groups presented similar results. In both general population and patient samples, the MYLIP rs9370867 polymorphism was differently distributed according to ethnicity. In the general population, subjects carrying GG genotypes had higher systolic blood pressure (BP), diastolic BP, and mean BP values (129.0 +/- 23.3; 84.9 +/- 14.6; 99.5 +/- 16.8 mmHg) compared with subjects carrying AA genotypes (123.7 +/- 19.5; 81.6 +/- 11.8; 95.6 +/- 13.6 mmHg) (p = 0.01; p = 0.02; p = 0.01, respectively), even after adjustment for covariates. However, in analysis stratified by ethnicity, this finding was not found and there is no evidence that the polymorphism influences BP. Conclusion: Our findings indicate that association studies involving this MYLIP variant can present distinct results according to the studied population. In this moment, further studies are needed to reaffirm if the MYLIP p.N342S polymorphism is functional or not, and to identify other functional markers within this gene.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Abstract Background Decreased heart rate variability (HRV) is related to higher morbidity and mortality. In this study we evaluated the linear and nonlinear indices of the HRV in stable angina patients submitted to coronary angiography. Methods We studied 77 unselected patients for elective coronary angiography, which were divided into two groups: coronary artery disease (CAD) and non-CAD groups. For analysis of HRV indices, HRV was recorded beat by beat with the volunteers in the supine position for 40 minutes. We analyzed the linear indices in the time (SDNN [standard deviation of normal to normal], NN50 [total number of adjacent RR intervals with a difference of duration greater than 50ms] and RMSSD [root-mean square of differences]) and frequency domains ultra-low frequency (ULF) ≤ 0,003 Hz, very low frequency (VLF) 0,003 – 0,04 Hz, low frequency (LF) (0.04–0.15 Hz), and high frequency (HF) (0.15–0.40 Hz) as well as the ratio between LF and HF components (LF/HF). In relation to the nonlinear indices we evaluated SD1, SD2, SD1/SD2, approximate entropy (−ApEn), α1, α2, Lyapunov Exponent, Hurst Exponent, autocorrelation and dimension correlation. The definition of the cutoff point of the variables for predictive tests was obtained by the Receiver Operating Characteristic curve (ROC). The area under the ROC curve was calculated by the extended trapezoidal rule, assuming as relevant areas under the curve ≥ 0.650. Results Coronary arterial disease patients presented reduced values of SDNN, RMSSD, NN50, HF, SD1, SD2 and -ApEn. HF ≤ 66 ms2, RMSSD ≤ 23.9 ms, ApEn ≤−0.296 and NN50 ≤ 16 presented the best discriminatory power for the presence of significant coronary obstruction. Conclusion We suggest the use of Heart Rate Variability Analysis in linear and nonlinear domains, for prognostic purposes in patients with stable angina pectoris, in view of their overall impairment.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

FUNDAMENTO: A realização da angiografia coronariana na insuficiência cardíaca sem etiologia definida é frequentemente justificada para avaliação diagnóstica de cardiopatia isquêmica. Porém, o benefício clínico dessa estratégia não é conhecido. OBJETIVO: Avaliar a prevalência de cardiopatia isquêmica mediante critérios angiográficos em pacientes com insuficiência cardíaca e fração de ejeção reduzida sem etiologia, assim como o seu impacto na decisão terapêutica. MÉTODOS: Foram avaliados pacientes ambulatoriais consecutivos com insuficiência cardíaca e disfunção sistólica, que tiveram a angiografia coronariana indicada para esclarecimento etiológico da cardiopatia, no período de 1º de janeiro de 2009 a 31 de dezembro de 2010. Os pacientes com diagnóstico de doença arterial coronariana, sorologia positiva para doença de Chagas, cardiopatia congênita, valvopatia grave ou pacientes submetidos a transplante cardíaco foram excluídos da análise. A amostra foi dividida em dois grupos conforme a indicação do cateterismo. Grupo-1: Sintomáticos em razão de angina ou insuficiência cardíaca refratária. Grupo-2: Presença de > 2 fatores de risco para doença arterial coronariana RESULTADOS: Cento e sete pacientes foram incluídos para análise, sendo 51 (47,7%) pacientes pertencentes ao Grupo-1 e 56 (52,3%), ao Grupo-2. A prevalência de cardiopatia isquêmica foi de 9,3% (10 pacientes), e todos pertenciam ao Grupo-1 (p = 0,0001). Durante o seguimento, apenas 4 (3,7%) tiveram indicação de revascularização miocárdica; 3 (2,8%) pacientes apresentaram complicações relacionadas ao procedimento. CONCLUSÃO: Em nosso trabalho, a realização da angiografia coronariana em pacientes com insuficiência cardíaca e disfunção sistólica sem etiologia, apesar de embasada pelas atuais diretrizes, não evidenciou benefício quando indicada apenas pela presença de fatores de risco para doença arterial coronariana.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A doença cardiovascular representa a principal causa de mortalidade no mundo. A capacidade de identificar, dentre os indivíduos assintomáticos, o subgrupo que apresenta maior risco de desenvolver eventos cardiovasculares no futuro representa uma etapa fundamental em qualquer estratégia voltada para a diminuição da taxas de eventos cardiovasculares. O primeiro passo na estratificação do risco cardiovascular é a utilização dos "escores de risco global", dentre os quais o mais frequentemente utilizado é o escore de Framingham. Entretanto, estudos prévios demonstraram que embora muito úteis, os escores clínicos, quando utilizados isoladamente, apresentam capacidade limitada de estratificação do risco cardiovascular em uma parcela significativa da população. É nesse contexto que o escore de cálcio (EC) coronariano e a angiotomografia das artérias coronárias podem desempenhar papel importante como ferramentas complementares na estratificação de risco dos pacientes assintomáticos. O EC coronariano proporciona importantes informações prognósticas que são incrementais aos escores clínicos baseados nos fatores de risco tradicionais e a outras modalidades diagnósticas, como a dosagem da proteína C reativa, por exemplo. Além disso, o EC também tem o potencial de alterar a conduta e auxiliar no manejo clínico dos pacientes. Já a angiotomografia coronariana proporciona avaliação detalhada da anatomia das artérias coronárias, permitindo visualizar não apenas o lúmen, mas também as paredes arteriais coronarianas. Comparada à coronariografia invasiva convencional, a angiotomografia apresenta excelente acurácia para identificar e, principalmente, excluir a presença de lesões obstrutivas significativas. Adicionalmente, demonstrou-se capaz de proporcionar informações prognósticas incrementais aos fatores de risco tradicionais e ao EC coronariano.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Myocardial perfusion quantification by means of Contrast-Enhanced Cardiac Magnetic Resonance images relies on time consuming frame-by-frame manual tracing of regions of interest. In this Thesis, a novel automated technique for myocardial segmentation and non-rigid registration as a basis for perfusion quantification is presented. The proposed technique is based on three steps: reference frame selection, myocardial segmentation and non-rigid registration. In the first step, the reference frame in which both endo- and epicardial segmentation will be performed is chosen. Endocardial segmentation is achieved by means of a statistical region-based level-set technique followed by a curvature-based regularization motion. Epicardial segmentation is achieved by means of an edge-based level-set technique followed again by a regularization motion. To take into account the changes in position, size and shape of myocardium throughout the sequence due to out of plane respiratory motion, a non-rigid registration algorithm is required. The proposed non-rigid registration scheme consists in a novel multiscale extension of the normalized cross-correlation algorithm in combination with level-set methods. The myocardium is then divided into standard segments. Contrast enhancement curves are computed measuring the mean pixel intensity of each segment over time, and perfusion indices are extracted from each curve. The overall approach has been tested on synthetic and real datasets. For validation purposes, the sequences have been manually traced by an experienced interpreter, and contrast enhancement curves as well as perfusion indices have been computed. Comparisons between automatically extracted and manually obtained contours and enhancement curves showed high inter-technique agreement. Comparisons of perfusion indices computed using both approaches against quantitative coronary angiography and visual interpretation demonstrated that the two technique have similar diagnostic accuracy. In conclusion, the proposed technique allows fast, automated and accurate measurement of intra-myocardial contrast dynamics, and may thus address the strong clinical need for quantitative evaluation of myocardial perfusion.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of the Research of this Ph D Project is to improve the medical management after surgery for advanced heart failure, both after left ventricular assist devices (LVAD) implantation, and after heart transplantation in the long-term. Regarding heart transplantation (HTx), the Research Project is focused on diagnostics, classification, prevention and treatment of cardiac allograft vasculopathy (CAV), and on treatment of post-HTx cancers; the results are presented in the first part of this Thesis. In particular, the main aspect investigated are the prognostic role of information derived from coronary angiography, coronary tomography and intravascular ultrasound, and the different sensitivity of these techniques in predicting outcomes and in diagnosing CAV. Moreover, the role of mTOR inhibitors on CAV prevention or treatment is investigated, both alone and in combination with different anti-CMV prevention strategies, as well as the impact of mTOR inhibitors on clinical outcomes in the long term. Regarding LVAD, the main focus is on the role of transthoracic echocardiography in the management of patients with a continuous-flow, centrifugal, intrapericardial pump (HVAD, Heartware); this section is reported in the second part of this Thesis. The main aspects investigated are the use of echocardiography in patients with HVAD device and its interaction with the information derived from pump curves' analysis in predicting aortic valve opening status, a surrogate of the condition of support provided by the LVAD.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Recently, several cases of symptomatic and/or electrically detectable intracardiac inside-out abrasions in silicon-coated Riata® and Riata® ST leads have been described. However, the prevalence in asymptomatic patients with unremarkable implantable cardioverter defibrillator (ICD) interrogation is unknown. The aim of this study was to determine the prevalence of asymptomatic and electrically undetectable intracardiac inside-out abrasion in silicon-coated Riata® and Riata® ST leads. METHODS: All 52 patients with an active silicone-coated Riata® and Riata® ST lead followed up in our outpatient clinic were scheduled for a premature ICD interrogation and a biplane chest radiograph. When an intracardiac inside-out abrasion was suspected, this finding was confirmed by fluoroscopy. RESULTS: Mean time since implantation was 71±18months. An intracardiac inside-out abrasion was confirmed by fluoroscopy in 6 patients (11.5%). Mean time from lead implantation to detection of intracardiac inside-out abrasion was 79±14months. In all patients with an intracardiac inside-out abrasion, ICD interrogation showed normal and stable electrical parameters. Retrospectively, in 4 of these 6 patients, a coronary angiography performed 25±18months before diagnosis of intracardiac inside-out abrasion already showed the defect. Despite undetected intracardiac inside-out abrasion, 2 of these 4 patients experienced adequate antitachycardia pacing and ICD-shocks. ICD leads were replaced in all 6 patients. CONCLUSIONS: The prevalence of asymptomatic intracardiac inside-out abrasion in silicon-coated Riata® and Riata® ST leads is higher than 10% when assessed by fluoroscopy, and most intracardiac inside-out abrasions are not detectable by ICD interrogation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES:: This study was designed to apply the rapid Elecsys(R) S100 immunoassay for real-time measurement of S100 protein serum levels indicating acute brain damage in patients undergoing carotid artery stenting (CAS) or endarterectomy (CEA). DESIGN AND METHODS:: Data of 14 CAS patients were compared to those of 43 CEA and 14 control patients undergoing coronary angiography (CA). S100 serum levels were measured by the full-automatic Elecsys(R) S100 immunoassay and compared to those obtained by the well-established LIA-mat(R) S100 system. RESULTS:: In contrast to CAS and CA patients, median S100 serum levels of CEA patients significantly increased to 0.24 ng/mL before declamping, but subsequently returned to baseline. Three CEA patients with neurological deficits showed sustained elevated S100 levels 6 h after extubation. Absolute S100 values were not significantly different between the two methods. Bland-Altman plot analyses displayed a good agreement, mostly indicating slightly smaller values applying the Elecsys(R) S100 system. CONCLUSIONS:: The Elecsys(R) S100 system appears to be suitable for rapid real-time detection of neurological deficits in patients undergoing CAS and CEA. Persistent elevations of Elecsys(R) S100 levels during CEA were associated with prolonged neurological disorders, whereas transient increases seem to represent impaired blood-brain barrier integrity without neurological deficits.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: The tradition of yearly reports on cardiac catheter interventions in Europe has been initiated in 1992. This 11th report presents aggregated data on cardiac catheter procedures in 30 European countries in the year 2002. DESIGN AND SETTING: A detailed questionnaire addressing summary data of all cardiac interventions was mailed to presidents or delegates of the national societies of cardiology in Europe. The questionnaire was distributed to all institutions with cardiac catheterisation programs. All questionnaires were compiled in a national summary data sheet, then entered into a central database and subsequently analysed. MAIN OUTCOME MEASURES: Coronary angiography, PTCA, and stenting in absolute numbers and per million inhabitants in the participating countries and the whole of Europe. RESULTS: Overall, 1,901,932 coronary angiograms were reported. The population-adjusted rate of coronary angiograms amounted to an absolute mean of 3358 per 10(6) inhabitants, an increase of 7% compared with 2001. A total of 686,869 PTCA procedures were reported. The mean European number of PTCAs per 10(6) inhabitants increased by 10% from 1103 in 2001 to 1213 in 2002. Procedures with stenting increased by 17% from 508,999 to 593,906. The stenting rate was 86% compared with 82% in 2001. CONCLUSIONS: In pace with epidemiological demand and the need to catch-up from underuse in certain countries, a continuous and considerable growth of coronary interventions can be observed. It will take years to find out whether the announced change of paradigm in the treatment of multivessel disease in the wake of drug-eluting stents will come true.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We report of a 71-year-old woman with a history of chronic analgesic nephropathy, who underwent coronary angiography. Because of anterior ventricular aneurysm, anticoagulation with nadroparine was installed. Continued ACE-inhibitor and ASA with additional intravenous contrast substance lead to acute tubular necrosis with rapid decline of the renal function. Due to accumulation of the low molecular weight heparin, the patient developed an extensive retroperitoneal haematoma with circulatory shock and temporary anuric kidney failure. Low molecular weight heparins are commonly used during percutaneous coronary interventions. They are as safe and efficient compared to unfractioned heparin. But due to their renal elimination, they have to be monitored by measuring anti-factor Xa-activity if creatinine-clearance is <30 ml/min.