938 resultados para Comparison between methods of analysis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The high incidence of respiratory disorders is one of the main problems in perinatal medical care. With the increased use of intubation, the incidence of laryngeal injury causing stenosis has also increased. The principal constriction point in the infant`s larynx is the midcricoid area. We sought to provide detailed morphometric data on the anatomy of the cricoid cartilage and its relationship with growth and body characteristics of fetuses at 5 to 9 months of gestational age. Methods: Nineteen larynges obtained from 17 stillborn infants and 2 newborn infants ranging in gestational age from 5 to 9 months were studied. Measurements of the cricoid cartilage were made with a millimeter-graded caliper. Results: Weight was the variable most correlated with cricoid measurements. The cricoid lumen configuration showed an almost elliptic shape and did not change with gestational age. The mean inner subglottic cricoid area was 19.27 +/- 9.62 mm(2) and was related to weight and body surface area. Cricoid growth was more pronounced at the outer portion of the cartilage. Conclusions: The cricoid lumen configuration was elliptic, and its mean area was smaller than that of available endotracheal tubes. This lumen area was most influenced by weight and height.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction. Lung tranplantation, a consolidated treatment for end-stage lung disease, utilizes preservation solutions, such as low potassium dextran (LPD), to mitigate ischemia reperfusion injury. We sought the local development of LPD solutions in an attempt to facilitate access and enhance usage. We also sought to evaluate the effectiveness of a locally manufactured LPD solution in a rat model of ex vivo lung perfusion. Methods. We randomized the following groups \?\adult of male Wistar rats (n = 25 each): Perfadex (LPD; Vitro life, Sweden); locally manufactured LPD-glucose (LPDnac) (Farmoterapica, Brazil), and normal saline solution (SAL) with 3 ischemic times (6, 12, and 24 hours). The harvested heart lung blocks were flushed with solution at 4 C. After storage, the blocks were connected to an IL-2 Isolated Perfused Rat or Guinea Pig Lung System (Harvard Apparatus) and reperfused with homologous blood for 60 minutes. Respiratory mechanics, pulmonary artery pressure, perfusate blood gas analysis, and lung weight were measured at 10-minute intervals. Comparisons between groups and among ischemic times were performed using analysis of variance with a 5% level of significance. Results. Lungs preserved for 24 hours were nonviable and therefore excluded from the analysis. Those preserved for 6 hours showed better ventilatory mechanics when compared with 12 hours. The oxygenation capacity was not different between lungs flushed with LPD or LPDnac, regardless of the ischemic time. SAL lungs showed higher PCO(2) values than the other solutions. Lung weight increased over time during perfusion; however, there were no significant differences among the tested solutions (LPD, P = .23; LPDnac, P = .41; SAL, P = .26). We concluded that the LPDnac solution results in gas exchange were comparable to the original LPD (Perfadex); however ventilatory mechanics and edema formation were better with LPD, particularly among lungs undergoing 6 hours of cold ischemia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background-Coronary artery bypass graft surgery with cardiopulmonary bypass is a safe, routine procedure. Nevertheless, significant morbidity remains, mostly because of the body`s response to the nonphysiological nature of cardiopulmonary bypass. Few data are available on the effects of off-pump coronary artery bypass graft surgery (OPCAB) on cardiac events and long-term clinical outcomes. Methods and Results-In a single-center randomized trial, 308 patients undergoing coronary artery bypass graft surgery were randomly assigned: 155 to OPCAB and 153 to on-pump CAB (ONCAB). Primary composite end points were death, myocardial infarction, further revascularization (surgery or angioplasty), or stroke. After 5-year follow-up, the primary composite end point was not different between groups (hazard ratio 0.71, 95% CI 0.41 to 1.22; P=0.21). A statistical difference was found between OPCAB and ONCAB groups in the duration of surgery (240 +/- 65 versus 300 +/- 87.5 minutes; P<0.001), in the length of ICU stay (19.5 +/- 17.8 versus 43 +/- 17.0 hours; P<0.001), time to extubation (4.6 +/- 6.8 versus 9.3 +/- 5.7 hours; P<0.001), hospital stay (6 +/- 2 versus 9 +/- 2 days; P<0.001), higher incidence of atrial fibrillation (35 versus 4% of patients; P<0.001), and blood requirements (31 versus 61% of patients; P<0.001), respectively. The number of grafts per patient was higher in the ONCAB than the OPCAB group (2.97 versus 2.49 grafts/patient; P<0.001). Conclusions-No difference was found between groups in the primary composite end point at 5-years follow-up. Although OPCAB surgery was related to a lower number of grafts and higher episodes of atrial fibrillation, it had no significant implications related to long-term outcomes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Total knee arthroplasty (TKA) imposes many risks. TKA infection is not the most frequent complication, but is probably the most serious one. Two-step review is the procedure of choice in deep knee prosthesis infection. On the other hand, aseptic prosthesis detachment represents almost half of the primary arthroplasty review indications, Patient`s satisfaction level might diminish after reviews. Objective: The objective of this study was to compare the quality of life and final result of TKA review for septic and aseptic failures. Methods: The patients were assessed using the HSS and SF-36 scores. The patients were divided in two groups: one group submitted to two-step review (septic) and the other to one-step review (aseptic). The analysis of the data obtained shows better scores for the second group in HSS and in 06 of 08 domains of SF-36 classification. Conclusions: The on-step review of total knee arthroplasty leads to better functional outcomes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To compare videofluoroscopy swallowing study (VFSS) with the fiberoptic endoscopic evaluation of swallowing (FEES) in children and to determine the accuracy of FEES in the diagnosis of specific swallowing disorders. STUDY DESIGN: Cross-sectional study. SETTING: Hospital da Crianca Santo Antonio, affiliated with Santa Casa de Misericordia Hospital Complex, Porto Alegre, RS, Brazil. SUBJECTS AND METHODS: FEES findings were compared to those of VFSS in 30 children. Kappa coefficients for interobserver agreement were calculated. Thereafter, these coefficients were evaluated in terms of agreement between FEES and VFSS. In addition, the sensitivity, specificity, positive predictive value, and negative predictive value of FEES were calculated for four swallowing parameters (posterior spillover, pharyngeal residues, laryngeal penetration, and laryngotracheal aspiration). RESULTS: Interobserver agreement rates greater than 70 percent were obtained for all FEES parameters analyzed, except for pharyngeal residues with puree consistency (agreement = 66.7%, K = 0.296, P = 0.091). Laryngeal aspiration and penetration yielded the best level of agreement (100%, K = 1) for the laryngeal aspiration of puree residues. CONCLUSION: The diagnostic agreement between FEES (both observers) and VFSS was low. Regarding the analyzed parameters, laryngeal penetration and aspiration yielded the highest interobserver agreement in terms of FEES, and also showed the highest specificity and positive predictive value when compared to VFSS. (C) 2010 American Academy of Otolaryngology-Head and Neck Surgery Foundation. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is very little human disease associated with enterohaemorrhagic Escherichia coli O157 in Australia even though these organisms are present in the animal population. A group of Australian isolates of E. coli O157:H7 and O157:H- from human and animal sources were tested for the presence of virulence markers and compared by XbaI DNA macrorestriction analysis using pulsed-field gel electrophoresis (PFGE). Each of 102 isolates tested contained the gene eae which encodes the E. coli attaching and effacing factor and all but one carried the enterohaemolysin gene, ehxA, found on the EHEC plasmid. The most common Shiga toxin gene carried was stx(2c), either alone (16%) or in combination with stx(1) (74%) or stx(2) (3%) PFGE grouped the isolates based on H serotype and some clusters were source specific. Australian E. coli O157:H7 and H- isolates from human, animal and meat sources carry all the virulence markers associated with EHEC disease in humans therefore other factors must be responsible for the low rates of human infection in Australia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To obtain population estimates and profile risk factors for infant mortality in two birth cohorts and compare them among cities of different regions in Brazil. METHODS: In Ribeirão Preto, southeast Brazil, infant mortality was determined in a third of hospital live births (2,846 singleton deliveries) in 1994. In São Luís, northeast Brazil, data were obtained using systematic sampling of births stratified by maternity unit (2,443 singleton deliveries) in 1997-1998. Mothers answered standardized questionnaires shortly after delivery and information on infant deaths was retrieved from hospitals, registries and the States Health Secretarys' Office. The relative risk (RR) was estimated by Poisson regression. RESULTS: In São Luís, the infant mortality rate was 26.6/1,000 live births, the neonatal mortality rate was 18.4/1,000 and the post-neonatal mortality rate was 8.2/1,000, all higher than those observed in Ribeirão Preto (16.9, 10.9 and 6.0 per 1,000, respectively). Adjusted analysis revealed that previous stillbirths (RR=3.67 vs 4.13) and maternal age <18 years (RR=2.62 vs 2.59) were risk factors for infant mortality in the two cities. Inadequate prenatal care (RR=2.00) and male sex (RR=1.79) were risk factors in São Luís only, and a dwelling with 5 or more residents was a protective factor (RR=0.53). In Ribeirão Preto, maternal smoking was associated with infant mortality (RR=2.64). CONCLUSIONS: In addition to socioeconomic inequalities, differences in access to and quality of medical care between cities had an impact on infant mortality rates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper proposes two meta-heuristics (Genetic Algorithm and Evolutionary Particle Swarm Optimization) for solving a 15 bid-based case of Ancillary Services Dispatch in an Electricity Market. A Linear Programming approach is also included for comparison purposes. A test case based on the dispatch of Regulation Down, Regulation Up, Spinning Reserve and Non-Spinning Reserve services is used to demonstrate that the use of meta-heuristics is suitable for solving this kind of optimization problem. Faster execution times and lower computational resources requirements are the most relevant advantages of the used meta-heuristics when compared with the Linear Programming approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electricity market players operating in a liberalized environment requires access to an adequate decision support tool, allowing them to consider all the business opportunities and take strategic decisions. Ancillary services represent a good negotiation opportunity that must be considered by market players. For this, decision support tool must include ancillary market simulation. This paper proposes two different methods (Linear Programming and Genetic Algorithm approaches) for ancillary services dispatch. The methodologies are implemented in MASCEM, a multi-agent based electricity market simulator. A test case based on California Independent System Operator (CAISO) data concerning the dispatch of Regulation Down, Regulation Up, Spinning Reserve and Non-Spinning Reserve services is included in this paper.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose - To compare the image quality and effective dose applying the 10 kVp rule with manual mode acquisition and AEC mode in PA chest X-ray. Method - 68 images (with and without lesions) were acquired using an anthropomorphic chest phantom using a Wolverson Arcoma X-ray unit. These images were compared against a reference image using the 2 alternative forced choice (2AFC) method. The effective dose (E) was calculated using PCXMC software using the exposure parameters and the DAP. The exposure index (lgM provided by Agfa systems) was recorded. Results - Exposure time decreases more when applying the 10 kVp rule with manual mode (50%–28%) when compared with automatic mode (36%–23%). Statistical differences for E between several ionization chambers' combinations for AEC mode were found (p = 0.002). E is lower when using only the right AEC ionization chamber. Considering the image quality there are no statistical differences (p = 0.348) between the different ionization chambers' combinations for AEC mode for images with no lesions. Considering lgM values, it was demonstrated that they were higher when the AEC mode was used compared to the manual mode. It was also observed that lgM values obtained with AEC mode increased as kVp value went up. The image quality scores did not demonstrate statistical significant differences (p = 0.343) for the images with lesions comparing manual with AEC mode. Conclusion - In general the E is lower when manual mode is used. By using the right AEC ionising chamber under the lung the E will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the visibility of the lesions or image quality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the present study, the performance of Immunomagnetic Separation technique, coupled with Immunofluorescence (IMS-IFA), was compared with the FAUST et al. and Lutz parasitological techniques for the detection of Giardia lamblia cysts in human feces. One hundred and twenty-seven samples were evaluated by the three techniques at the same time showing a rate of cyst detection of 27.5% by IMS-IFA and 15.7% by both Faust et al. and Lutz techniques. Data analysis showed a higher sensitivity of IMS-IFA for the detection of G. lamblia cysts in comparison with the techniques of FAUST et al. and Lutz. The use of this methodology as a routine procedure enables the processing of many samples simultaneously, in order to increase recovery rate of G. lamblia cysts and reduce the time of sample storage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thirty Candida albicans isolated from oral candidosis patients and 30 C. albicans isolated from control individuals were studied. In vitro susceptibility tests were performed for amphotericin B, fluconazole, 5-flucytosine and itraconazole through the Clinical and Laboratorial Standards Institute (CLSI) reference method and E test system. The results obtained were analyzed and compared. MIC values were similar for the strains isolated from oral candidosis patients and control individuals. The agreement rate for the two methods was 66.67% for amphotericin B, 53.33% for fluconazole, 65% for flucytosine and 45% for itraconazole. According to our data, E test method could be an alternative to trial routine susceptibility testing due to its simplicity. However, it can not be considered a substitute for the CLSI reference method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

21th Annual Conference of the International Group for Lean Construction (IGLC 21), July 2013, Fortaleza, Brazil

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Abdominal palpation and ultrasound findings among patients from an endemic area for schistosomiasis in Brazil who had been followed up for 27 years were compared. METHODS: In 2004, 411 patients from Brejo do Espírito Santo, in the State of Bahia, were selected for the present investigation after giving their written informed consent. Based on clinical data, they were divided into three groups: 41 patients with evidence of liver fibrosis in 2004 (Group 1); 102 patients with evidence of liver fibrosis in the past (1976-1989) but not in 2004 (Group 2); and 268 patients without evidence of liver fibrosis at any time during the 27-year follow-up (Group 3). All of the patients underwent abdominal ultrasound in which the examiner did not know the result from the clinical examination. The data were stored in a database. RESULTS: The prevalence of periportal fibrosis on ultrasound was 82.9%, 56.9% and 13.4% in Groups 1, 2 and 3, respectively. In the presence of hard, nodular liver or prominent left lobe and a hard palpable spleen, ultrasound revealed periportal fibrosis in 70.9%. However, periportal fibrosis was diagnosed using ultrasound in 25.4% of the patients in the absence of clinical evidence of liver involvement. Thus, ultrasound diagnosed periportal fibrosis 3.1 times more frequently than clinical examination did. CONCLUSIONS: Although clinical examination is important in evaluating morbidity due to Manson's schistosomiasis in endemic areas, ultrasound is more accurate in diagnosing liver involvement and periportal fibrosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

New emerging contaminants could represent a danger to the environment and Humanity with repercussions not yet known. One of the major worldwide pharmaceutical and personal care productions are antimicrobials products, triclosan, is an antimicrobial agent present in most products. Despite the high removal rate of triclosan present in wastewater treatments, triclosan levels are on the rise in the environment through disposal of wastewater effluent and use of sewage sludge in land application. Regulated in the EC/1272/2008 (annex VI, table 3.1), this compound is considered very toxic to aquatic life and it has been reported that photochemical transformation of triclosan produces dioxins. In the current work it was defined three objectives; determination of the most efficient process in triclosan degradation, recurring to photochemical degradation methods comparing different sources of light; identification of the main by-products formed during the degradation and the study of the influence of the Fenton and photo-Fenton reaction. Photochemical degradation methods such as: photocatalysis under florescent light (UV), photocatalysis under visible light (sunlight), photocatalysis under LEDs, photo-Fenton and Fenton reaction have been compared in this work. The degradation of triclosan was visualized through gas chromatography/mass spectrometry (GC/MS). In this study photo-Fenton reaction has successfully oxidized triclosan to H2O and CO2 without any by-products within 2 hours. Photocatalysis by titanium dioxide (TiO2) under LEDs was possible, having a degradation rate of 53% in an 8 hours essay. The degradation rate of the Fenton reaction, UV light and sunlight showed degradation between 90% and 95%. The results are reported to the data observed without statistic support, since this was not possible during the work period. Hydroquinone specie and 2,4-dichlorophenol by-products were identified in the first hour of photocatalysis by UV. A common compound, possibly identified has C7O4H , was present at the degradation by UV, sunlight and LEDs and was concluded to be a contaminant. In the future more studies in the use of LEDs should be undertaken given the advantages of long durability and low consumption of energy of these lamps and that due to their negative impact on the environment fluorescent lamps are being progressively made unavailable by governments, requiring new solutions to be found. Fenton and photo-Fenton reactions can also be costly processes given the expensive reagents used.