949 resultados para Color Doppler sonography


Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE Renal resistive index (RRI) varies directly with renal vascular stiffness and pulse pressure. RRI correlates positively with arteriolosclerosis in damaged kidneys and predicts progressive renal dysfunction. Matrix Gla-protein (MGP) is a vascular calcification inhibitor that needs vitamin K to be activated. Inactive MGP, known as desphospho-uncarboxylated MGP (dp-ucMGP), can be measured in plasma and has been associated with various cardiovascular (CV) markers, CV outcomes and mortality. In this study we hypothesize that increased RRI is associated with high levels of dp-ucMGP. DESIGN AND METHOD We recruited participants via a multi-center family-based cross-sectional study in Switzerland exploring the role of genes and kidney hemodynamics in blood pressure regulation. Dp-ucMGP was quantified in plasma samples by sandwich ELISA. Renal doppler sonography was performed using a standardized protocol to measure RRIs on 3 segmental arteries in each kidney. The mean of the 6 measures was reported. Multiple regression analysis was performed to estimate associations between RRI and dp-ucMGP adjusting for sex, age, pulse pressure, mean pressure, renal function and other CV risk factors. RESULTS We included 1035 participants in our analyses. Mean values were 0.64 ± 0.06 for RRI and 0.44 ± 0.21 (nmol/L) for dp-ucMGP. RRI was positively associated with dp-ucMGP both before and after adjustment for sex, age, body mass index, pulse pressure, mean pressure, heart rate, renal function, low and high density lipoprotein, smoking status, diabetes, blood pressure and cholesterol lowering drugs, and history of CV disease (P < 0.001). CONCLUSIONS RRI is independently and positively associated with high levels of dp-ucMGP after adjustment for pulse pressure and common CV risk factors. Further studies are needed to determine if vitamin K supplementation can have a positive effect on renal vascular stiffness and kidney function.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Ischemic complications during aneurysm surgery are a frequent cause of postoperative infarctions and new neurological deficits. In this article, we discuss imaging and neurophysiological tools that may help the surgeon to detect intraoperative ischemia. The strength of intraoperative digital subtraction angiography (DSA) is the full view of the arterial and venous vessel. DSA is the gold standard in complex and giant aneurysms, but due to certain disadvantages, it cannot be considered standard of care. Microvascular Doppler sonography is probably the fastest diagnostic tool and can quickly aid diagnosis of large vessel occlusions. Intraoperative indocyanine green videoangiography is the best tool to assess flow in perforating and larger arteries, as well as occlusion of the aneurysm sac. Intraoperative neurophysiological monitoring with somatosensory and motor evoked potentials indirectly measures blood flow by recording neuronal function. It covers all causes of intraoperative ischemia, provided that ischemia occurs in the brain areas under surveillance. However, every method has advantages and disadvantages. No single method is superior to the others in every aspect. Therefore, it is very important for the neurosurgeon to know the strengths and weaknesses of each tool in order to have them available, to know how to use them for each individual situation, and to be ready to apply them within the time window for reversible cerebral ischemia.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: False-negative interpretations of do-butamine stress echocardiography (DSE) may be associated with reduced wall stress. using measurements of contraction, we sought whether these segments were actually ischemic but unrecognized or showed normal contraction. Methods. We studied 48 patients (29 men; mean age 60 +/- 10 years) with normal regional function on the basis of standard qualitative interpretation of DSE. At coronary angiography within. 6 months of DSE, 32 were identified as having true-negative and 16 as having false-negative results of DSE. Three apical views were used to measure regional function with color Doppler tissue, integrated backscatter, and strain rate imaging. Cyclic variation of integrated backscatter was measured in 16 segments, and strain rate and peak systolic strain was calculated in 6 walls at rest and peak stress. Results. Segments with false-negative results of DSE were divided into 2 groups with and without low wall stress according to previously published cut-off values. Age, sex, left ventricular mass, left ventricular geometric pattern, and peak workload were not significantly different between patients with true and false-negative results of DSE. Importantly, no significant differences in cyclic variation and strain parameters at rest and peak stress were found among segments with true-and false-negative results of DSE with and without low wall stress. Stenosis severity had no influence on cyclic variation and strain parameters at peak stress. Conclusions: False-negative results of DSE reflect lack of ischemia rather than underinterpretation of regional left ventricular function. Quantitative markers are unlikely to increase the sensitivity of DSE.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background. To evaluate the haemodynamic features of young healthy myopes and emmetropes, in order to ascertain the perfusion profile of human myopia and its relationship with axial length prior to reaching a degenerative state. Methods The retrobulbar, microretinal and pulsatile ocular blood flow (POBF) of one eye of each of twenty-two high myopes (N=22, mean spherical equivalent (MSE) =-5.00D), low myopes (N=22, MSE-1.00 to-4.50D) and emmetropes (N=22, MSE±0.50D) was analyzed using color Doppler Imaging, Heidelberg retinal flowmetry and ocular blood flow analyser (OBF) respectively. Intraocular pressure, axial length (AL), systemic blood pressure, and body mass index were measured. Results. When compared to the emmetropes and low myopes, the AL was greater in high myopia (p<0.0001). High myopes showed higher central retinal artery resistance index (CRA RI) (p=0.004), higher peak systolic to end diastolic velocities ratio (CRA ratio) and lower end diastolic velocity (CRA EDv) compared to low myopes (p=0.014, p=0.037). Compared to emmetropes, high myopes showed lower OBFamplitude (OBFa) (p=0.016). The POBF correlated significantly with the systolic and diastolic blood velocities of the CRA (p=0.016, p=0.036). MSE and AL correlated negatively with OBFa (p=0.03, p=0.003), OBF volume (p=0.02, p<0.001), POBF (p=0.01, p<0.001) and positively with CRA RI (p=0.007, p=0.05). Conclusion. High myopes exhibited significantly reduced pulse amplitude and CRA blood velocity, the first of which may be due to an OBF measurement artefact or real decreased ocular blood flow pulsatility. Axial length and refractive error correlated moderately with the ocular pulse and with the resistance index of the CRA, which in turn correlated amongst themselves. It is hypothesized that the compromised pulsatile and CRA haemodynamics observed in young healthy myopes is an early feature of the decrease in ocular blood flow reported in pathological myopia. Such vascular features would increase the susceptibility for vascular and age-related eye diseases.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To evaluate the relationship between ocular perfusion pressure and color Doppler measurements in patients with glaucoma. MATERIALS AND METHODS: Twenty patients with primary open-angle glaucoma with visual field deterioration in spite of an intraocular pressure lowered below 21 mm Hg, 20 age-matched patients with glaucoma with stable visual fields, and 20 age-matched healthy controls were recruited. After a 20-minute rest in a supine position, intraocular pressure and color Doppler measurements parameters of the ophthalmic artery and the central retinal artery were obtained. Correlations between mean ocular perfusion pressure and color Doppler measurements parameters were determined. RESULTS: Patients with glaucoma showed a higher intraocular pressure (P <.0008) and a lower mean ocular perfusion pressure (P <.0045) compared with healthy subjects. Patients with deteriorating glaucoma showed a lower mean blood pressure (P =.033) and a lower end diastolic velocity in the central retinal artery (P =.0093) compared with normals. Mean ocular perfusion pressure correlated positively with end diastolic velocity in the ophthalmic artery (R = 0.66, P =.002) and central retinal artery (R = 0.74, P <.0001) and negatively with resistivity index in the ophthalmic artery (R = -0.70, P =.001) and central retinal artery (R = -0.62, P =.003) in patients with deteriorating glaucoma. Such correlations did not occur in patients with glaucoma with stable visual fields or in normal subjects. The correlations were statistically significantly different between the study groups (parallelism of regression lines in an analysis of covariance model) for end diastolic velocity (P =.001) and resistivity index (P =.0001) in the ophthalmic artery, as well as for end diastolic velocity (P =.0009) and resistivity index (P =. 001) in the central retinal artery. CONCLUSIONS: The present findings suggest that alterations in ocular blood flow regulation may contribute to the progression in glaucomatous damage.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Cyclic endometrial neoangiogenesis contributes to changes in local vascular patterns and is amenable to non-invasive assessment with Doppler sonography. We hypothesize that the uterine artery (UtA) impedance, measured by its pulsatility index (PI), exhibits a regular pattern during the normal menstrual cycle. Therefore, the main study objective was to derive normative new day-cycle-based reference ranges for the UtA-PI during the entire cycle from days 1 to 34 according to the isolated time effect and potential confounders such as age and parity.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a artéria subclávia direita durante a ecografia do primeiro trimestre, descrever a técnica para a sua avaliação e, em caso de identificação de artéria subclávia direita aberrante (ARSA), determinar sua associação com alterações cromossómicas e/ou malformações cardíacas e sua orientação.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Diabetes mellitus type 1 is the most common endocrine metabolic disorder occurring in childhood and adolescence due to the autoimmune destruction of pancreatic beta cells as a result of various environmental factors interacting with an underlying genetic predisposition. Diabetes is a risk factor for early onset atherosclerosis, and the high mortality rate seen in these patients is partially related to cardiovascular diseases. Objectives: This study was conducted to compare mean platelet volume as a marker of early atherosclerosis with aortic intima-media thickness in children with type 1 diabetes and to identify its correlation with known cardiovascular risk factors. Patients and Methods: The study included 27 patients between age range of 6 and 17 years that were diagnosed with type 1 diabetes and 30 healthy children of the same age range who did not have any chronic disease. In both groups, we used the color Doppler ultrasound to measure children’s aortic intima-media thickness and identify their mean platelet volumes. Results: There was no significant difference between the groups regarding gender distribution, age, High-Density Lipoprotein (HDL) and Low-Density Lipoprotein (LDL) cholesterol levels (P > 0.05). Also no significant difference could be documented between the patient and control groups regarding the aortic intima-media thickness and mean platelet volume (P > 0.05). However, there was a significant correlation between aortic intima-media thickness and mean platelet volume (r = 0.351; P < 0.05). Conclusions: In the present study, there was no evidence of early atherosclerosis in children with type 1 diabetes. However, mean platelet volume having a significant correlation with aortic intima-media thickness may be useful as an early marker of atherosclerosis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Testicular torsion (TT), or twisting of the testicle resulting in a strangulation of the blood supply, occurs in men whose tissue surrounding the testicle is not well attached to the scrotum. It is important to emphasize that testicular torsion is a medical emergency. Objectives: The aim of this study is to evaluate the second look exploration and outcomes in TT. Patients and Methods: Seventy boys out of 124 patients underwent early exploration and 48 hours later second look exploration due to TT. All patients were checked with preoperative color-doppler ultrasonography (CDU) and intraoperative bleeding test. Data included age at admission, side of pathology, relation of TT with season of year, duration of preoperative history, degree of testicular torsion, CDU findings, and degree of bleeding; results of second look exploration, follow-up, and outcomes were analyzed. Results: Totally 70 patients were included in this study within five years, of which mean age was 28.6 ± 32.9 months (range 1 to 144), 48% of our patients had nausea and vomiting. Preoperative CDU showed absent/weak flow in 50 (71%) cases. Winter showed most frequently (44%) referred cases of testicular torsion. Orchidopexy was performed in 44 (63%) and orchidectomy in 26 (37%) cases after second look exploration. Mean follow-up duration was 3.1 ± 1.4 years. 4 (9%) cases in orchidopexy group developed testicular atrophy during follow-up, all four cases had a history of longer than 12 hours and grade II testicular bleeding test intra-operatively. Other orchidopexy patients salvaged. 26 patients, who were in grade III, underwent orchidectomy in second look exploration. Conclusions: TT requires emergency attention. The ischemia time of the testis is traditionally after 6 hours, and imaging or other diagnostic modality should not be a cause of delay. Early surgical exploration is modality of choice, and second look exploration after 48 hours can be more effective and salvageable in these patients.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Renal diseases are common in older cats. Decreased renal blood flow may be the first sign of dysfunction and can be evaluated by Doppler ultrasound. But previous studies suggest that the resistive index (RI) has a low sensitivity for detecting renal disease. Doppler waveforms of renal and intrarenal arteries demonstrate decreased blood flow before there are any changes in the RI. The purpose of this study was to evaluate the normal Doppler flowmetrics parameters of renal arteries (RAs), interlobar arteries (IAs) and abdominal aorta (AO) in adult healthy, Persian cats. Twenty-five Persian cats (13 females and 12 males with mean age of 30 months and an age range 12-60 months) with normal clinical examinations and biochemical tests and normal systemic blood pressure were given B-mode ultrasonographies in order to exclude all nephropathies, including polycystic kidney disease. All measurements were performed on both kidneys. Both kidneys (n = 50) were examined by color mapping of the renal vasculature. Pulsed Doppler was used to examine both RAs, the IAs at cranial, middle and caudal sites, and the AO. The RI was calculated for all of the vessels. Early systolic acceleration (ESA) of RA and IA was obtained with Doppler spectral analysis. Furthermore, the ratio indices between RA/AO, and IA/RA velocities were calculated. The mean values of peak systolic velocity (PSV) and the diameter for AO were 53.17 +/- 13.46 cm/s and 0.38 +/- 0.08 cm, respectively. The mean RA diameter for all 50 kidneys was 0.15 +/- 0.02 cm. Considering the velocimetric values in both RAs, the mean PSV and RI that were obtained were 41.17 +/- 9.40 cm/s and 0.54 +/- 0.07. The RA had a mean ESA of 1.12 +/- 1.14 m/s(2) and the calculated upper limit of the reference value was 3.40 m/s(2). The mean renal-aortic ratio was 0.828 +/- 0.296. The IA showed PSV and RI values of 32.16 +/- 9.33 cm/s and 0.52 +/- 0.06, respectively. The mean ESA of all IAs was 0.73 +/- 0.61 m/s(2). The calculated upper limit of the reference value was 2.0 m/s(2). The mean renal-interlobar artery ratio was 1.45 +/- 0.57. The RI values obtained in this study were similar to values reported in the literature. Some conditions that lead to a decrease in compliance and to an increase in vascular resistance can affect the Doppler spectral waveforms without changes in RI. To our knowledge, there are no studies that were directed toward to the normal ESA values of the renal vasculature in Persian cats. This study introduced a new ratio between the PSV of the RA and the IA. This index was developed based on the well-known effects of Doppler on the detection of stenosis, regardless of the cause. Further studies are necessary to verify the hemodynamic behavior of this index under pathological conditions in cats as well as the effect of aging, nephropathies and systemic pressure on Doppler velocimetric parameters. (C) 2010 ISFM and AAFP. Published by Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objectives To evaluate the presence of false flow three-dimensional (3D) power Doppler signals in `flow-free` models. Methods 3D power Doppler datasets were acquired from three different flow-free phantoms (muscle, air and water) with two different transducers and Virtual Organ Computer-aided AnaLysis was used to generate a sphere that was serially applied through the 3D dataset. The vascularization flow index was used to compare artifactual signals at different depths (from 0 to 6 cm) within the different phantoms and at different gain and pulse repetition frequency (PR F) settings. Results Artifactual Doppler signals were seen in all phantoms despite these being flow-free. The pattern was very similar and the degree of artifact appeared to be dependent on the gain and distance from the transducer. False signals were more evident in the far field and increased as the gain was increased, with false signals first appearing with a gain of 1 dB in the air and muscle phantoms. False signals were seen at a lower gain with the water phantom (-15 dB) and these were associated with vertical lines of Doppler artifact that were related to PRF, and disappeared when reflections were attenuated. Conclusions Artifactual Doppler signals are seen in flow-free phantoms and are related to the gain settings and the distance from the transducer. In the in-vivo situation, the lowest gain settings that allow the detection of blood flow and adequate definition of vessel architecture should be used, which invariably means using a setting near or below the middle of the range available. Additionally, observers should be aware of vertical lines when evaluating cystic or liquid-containing structures. Copyright (C) 2010 ISUOC. Published by John Wiley & Sons, Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduzione: Negli ultimi anni, il color-power Doppler si è dimostrato un utile strumento per valutare le alterazioni della vascolarizzazione della parete intestinale nelle patologie del tratto gastro-enterico. Più di recente, i mezzi di contrasto ecografici di II generazione associati all’ecografia real-time con basso indice meccanico (CEUS) hanno permesso di valutare ecograficamente il microcircolo, consentendo la valutazione della vascolarizzazione di parete nelle patologie associate a flogosi e neoangiogenesi. Studi recenti hanno documentato i pattern Doppler e CEUS nella malattia infiammatoria intestinale. Le alterazioni della vascolarizzazione di parete nella patologia neoplastica, invece, sono state finora valutate con sola tecnica Doppler. Recenti studi basati sull’impiego di tale metodica hanno in effetti dimostrato che l’intensità del segnale vascolare di parete correla con la variante istologica della neoplasia e con il suo grado di invasione vascolare costituendo così un parametro di neoangiogenesi tumorale. Pertanto, ottenere mediante CEUS una più accurata definizione del microcircolo di parete potrebbe aiutare nella diagnosi differenziale tra patologia infiammatoria e neoplastica dello stomaco e fornire utili informazioni per valutare l’ aggressività del cancro gastrico.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Evaluate the distribution and variation of placental vascular indices according to gestational age and placental volume. From March to November 2007, three-dimensional (3D)-power Doppler ultrasound was performed in 295 normal pregnancies from 12 to 40 weeks of gestation. Using the same preestablished settings for all patients, power Doppler was applied to the placenta and placental Volume was obtained by the rotational technique (VOCAL(TM)). The 3D-power histogram was used to determine the placental vascular indices: vascularization index (VI), flow index (FI) and vascularization-flow index (VFI). The placental vascular indices were then plotted against gestational age and placental volume. All placental vascular indices showed constant distribution throughout gestation. A tendency for a reduction in placental vascular indices with increased placental volume was observed, but was only statistically significant when placental FI was considered (p < 0.05). All placental vascular indices estimated by 3D-power Doppler ultrasonography presented constant distribution throughout gestation, despite the increase in placental volume according to gestational age. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The subjective interpretation of dobutamine echocardiography (DBE) makes the accuracy of this technique dependent on the experience of the observer, and also poses problems of concordance between observers. Myocardial tissue Doppler velocity (MDV) may offer a quantitative technique for identification of coronary artery disease, but it is unclear whether this parameter could improve the results of less expert readers and in segments with low interobserver concordance. The aim of this study was to find whether MDV improved the accuracy of wall motion scoring in novice readers, experienced echocardiographers, and experts in stress echocardiography, and to identify the optimal means of integrating these tissue Doppler data in 77 patients who underwent DBE and angiography. New or worsening abnormalities were identified as ischemia and abnormalities seen at rest as scarring. Segmental MDV was measured independently and previously derived cutoffs were applied to categorize segments as normal or ab normal. Five strategies were used to combine MDV and wall motion score, and the results of each reader using each strategy were compared with quantitative coronary angiography. The accuracy of wall motion scoring by novice (68 +/- 3%) and experienced echocardiographers (71 +/- 3%) was less than experts in stress echocardiography (88 +/- 3%, p < 0.001). Various strategies for integration with MDV significantly improved the accuracy of wall motion scoring by novices from 75 +/- 2% to 77 +/- 5% (p < 0.01). Among the experienced group, accuracy improved from 74 +/- 2% to 77 +/- 5% (p < 0.05), but in the experts, no improvement was seen from their baseline accuracy. Integration with MDV also improved discordance related to the basal segments. Thus, use of MDV in all segments or MDV in all segments with wall motion scoring in the apex offers an improvement in sensitivity and accuracy with minimal compromise in specificity. (C) 2001 by Excerpta Medica, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Diastolic dysfunction induced by ischemia may alter transmitral blood flow, but this reflects global ventricular function, and pseudonormalization may occur with increased preload. Tissue Doppler may assess regional diastolic function and is relatively load-independent, but limited data exist regarding its application to stress testing. We sought to examine the stress response of regional diastolic parameters to dobutomine echocardiography (DbE). Methods Sixty-three patients underwent study with DbE: 20 with low probability of coronary artery disease (CAD) and 43 with CAD who underwent angiography. A standard DbE protocol was used, and segments were categorized as ischemic, scar, or normal. Color tissue Doppler was acquired at baseline and peak stress, and waveforms in the basal and mid segments were used to measure early filling (Em), late filling (Am), and E deceleration time. Significant CAD was defined by stenoses >50% vessel diameter. Results Diastolic parameters had limited feasibility because of merging of Em and Am waves at high heart rates and limited reproducibility. Nonetheless, compared with normal segments, segments subtended with significant stenoses showed a lower Em velocity at rest (6.2 +/- 2.6 cm/s vs 4.8 +/- 2.2 cm/s, P < .0001) and peak (7.5 +/- 4.2 cm/s vs 5.1 +/- 3.6 cm/s, P < .0001), Abnormal segments also showed a shorter E deceleration time (51 +/- 27 ms vs 41 +/- 27 ms, P = .0001) at base and peak. No changes were documented in Am. The same pattern was seen with segments identified as ischemic with wall motion score. However, in the absence of ischemia, segments of patients with left ventricular hypertrophy showed a lower Em velocity, with blunted Em responses to stress. Conclusion Regional diastolic function is sensitive to ischemia. However, a number of practical limitations limit the applicability of diastolic parameters for the quantification of stress echocardiography.