946 resultados para Chemical Oxygen-Iodine Laser (Coil)
Resumo:
The organic matter. (OM) removal efficiency in the biochemical oxygen demand (BOD) and chemical oxygen demand (COD) forms for domestic wastewater and semi-intensive fish culture effluents by using three phase aerobic fluidized bed reactors with circulation in concentric tubes was studied. Three different ratios between external and internal areas by different internal diameter configurations (100, 125 and 150mm) to the same external diameter of 250mm were used; sand for filters and granulated activated carbon were used as supporting media. The reactors were tested for three hydraulic retention times: 11.5min to the R100, and 3h for the R125 and R150 reactors. The results demonstrated that this kind of reactors had good performance in the BOD and COD removal for different concentrations of waste waters. BOD mean removal efficiencies obtained were: 47% at the R100 reactor, 57% and 93% of raw and filtered BOD respectively at R125, 48 and 89% of raw and filtered BOD at R150. The COD mean calculated removal efficiencies were: 75% at the R100 reactor, 56 and 86% of raw and filtered COD at R125, and 54 and 86% of raw and filtered COD at R150. In the case of domestic wastewater it is necessary to provide a solids removal system at the reactor outflow in order to increase the removal of suspended OM from the final effluent.
Resumo:
In this work, electrochemical technology was used to treat synthetic wastewater containing Methyl Red (MR) and Blue Novacron (BN) by anodic oxidation using anodes platinum (Pt) and real samples of textile effluents using DDB anodes and platinum (Pt). The removal of color from the galvanostatic electrolysis of synthetic wastewater MR and BN, and the actual sample has been observed under different conditions (different current densities and temperature variation). The investigation of these parameters was performed in order to establish the best conditions for removal of color and chemical oxygen demand (BOD). According to the results obtained in this study, the electrochemical oxidation processes suitable for the degradation process of color and COD in wastewater containing such textile dyes, because the electrocatalytic properties of Pt and BDD anodes consumption energy during the electrochemical oxidation of synthetic solutions AN and MR and real sample, mainly depend on the operating parameters of operation, for example, the synthetic sample of MR, energy consumption rose from 42,00kWhm-3 in 40 mAcm-2 and 25 C to 17,50 kWhm-3 in 40mAcm-2 and 40 C, from the BN went 17,83 kWhm-3 in 40mAcm and 40°C to 14,04 kWhm- 3 in 40mAcm-2 and 40 C (data estimated by the volume of treated effluent). These results clearly indicate the applicability of electrochemical treatment for removing dyes from synthetic solutions and real industrial effluents
Resumo:
Rubrivivax gelatinosus was grown in Pfennig's synthetic medium (PM) and in treated wastewater from poultry slaughterhouse (TW) to assess growth profiles for biomass production. Cultures inoculated at 1% (v/v) were grown under anaerobiosis at 30 +/- 2 degrees C and 1400 200 lux for 12 days. Regular absorbance curves for R. gelatinosus were found both on PM and TW. on PM, the highest dry weight of biomass, 0.39 g L-1. was achieved in the 216-h culture and the highest specific growth rate of 0.2960 h(-1) occurred in the 24-h culture. on TW, the highest biomass of 0.57 g L-1 was also obtained in the 216-h culture and the highest specific growth rate, 0.1970 h(-1), was achieved in the 48-h culture. For productivity and chemical oxygen demand investigations, the cultivation was accomplished in the TW under anaerobiosis at 32 +/- 2 degrees C and 4000 +/- 500 lux, for 10 days. Productivity was 0.085 g biomass (d.w.) L-1 day(-1), with a COD decrease of 91%. (c) 2007 Elsevier Ltd. All rights reserved.
Resumo:
Propõe-se metodologia analítica para a determinação da demanda química de oxigênio(DQO) em águas e efluentes pouco poluídos, pela espectrofotometria simultânea dos íons crômio(III) e dicromato, após a clássica oxidação sulfocrômica das amostras, à quente e catalisada por íons Ag+. Demonstra-se que a inter-relação entre as concentrações de DQO, de crômio(III) formado e de dicromato residual permite simplificar a resolução numérica do sistema - de multicomponente, envolvendo as concentrações desses dois íons, e medidas de absorbância em pelo menos dois comprimentos de onda para monocomponente, envolvendo diretamente a concentração em DQO, e medida de absorbância num único comprimento de onda.
Resumo:
Physico-chemical and microbiological parameters were evaluated before and after applying an electrolytic process to effluents of a stabilization lagoon, in the presence or absence of salt. Chlorine generation and bactericidal properties of the treatments were studied following two experiments. Effluent pH increased with electrolysis time. In the absence of salt, 20 min electrolysis resulted in a COD (Chemical Oxygen Demand) reduction of 44%, along with ca. 99.9% (3 log10 cfu/mL) reduction in total coliforms, heterotrophic bacteria and Escherichia coli. These results indicated that the electrolytic process is a promising complementary technology to improve effluent quality for stabilization lagoons.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Estudou-se o reuso de água de um sistema composto por estação de tratamento de esgoto (ETE) com aeração prolongada e lodo ativado, e em uma estação compacta de tratamento de água (ECTA) de uma indústria metalúrgica. Os processos para obtenção da água de reuso foram: microbiológico e físico-químico. O esgoto doméstico foi bombeado para a ETE, onde houve formação de flocos biológicos e água clarificada. Avaliou-se a eficiência do processo microbiológico da ETE mediante a remoção de demanda bioquímica de oxigênio (DBO), demanda química de oxigênio (DQO) e sólidos sedimentáveis (SS). A eficiência do processo físico-químico de clarificação e desinfecção foi avaliada mediante análises de pH, turbidez, cor, contagem de bactérias heterotróficas aeróbias, cloro livre, dureza, alcalinidade, cloretos, sulfatos, sólidos totais dissolvidos (STD). Na água de reuso além desses parâmetros avaliou-se a toxicidade aguda ao microcrustáceo Daphnia similis.
Resumo:
The production of chlorine was investigated in the photoelectrocatalytic oxidation of a chloride-containing solution using a TiO(2) thin-film electrode biased at current density from 5 to 50 mA cm(-2) and illuminated by UV light. Such parameters as chloride concentrations from 0.001 to 0.10 mol L(-1), pH 2-12, and interfering salts were varied in this study in order to determine their effect on this oxidation process. At an optimum condition this photoelectrocatalytic method can produce active chlorine at levels compatible to water disinfections processes using a chloride concentration higher than 0.010 mol L(-1) at a pH of 4 and a current density of 30 mA cm(-2). The method was successfully applied to treat surface water collected from a Brazilian river. After 150 min of photoelectrocatalytic oxidation, we obtained a 90% reduction in total organic carbon removal, a 100% removal of turbidity, a 93% decrease in colour and a chemical oxygen demand (COD) removal of around 96% (N=3). The proposed technology based on photoelectrocatalytic oxidation was also tested in treating 250 mL of a solution containing 0.05 mol L(-1) NaCl and 50 mu g L(-1) of Microcystin aeruginosa. The bacteria is completely removed after 5 min of photoelectrocatalysis following an initial rate constant removal of -0.260 min(-1), suggesting that the present method could be considered as a promising alternative to chlorine-based disinfections. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
As concentrações de nutrientes (fósforo e nitrogênio) na nascente, cidade e foz do ribeirão Lavapés/ Botucatu-SP foram avaliadas e comparadas com as do rio Capivara. O rio Capivara como o ribeirão Lavapés, possui nascente no alto da cuesta e desemboca suas águas na represa de Barra Bonita/ rio Tietê (Figura 1). O rio Capivara possui uma das nascentes próxima a uma do ribeirão Lavapés e, ambos possuem a foz próxima uma da outra na represa de Barra Bonita. O uso e tipo de solo nas margens de ambos cursos d´águas são bastante parecidos, o que implica em uma poluição rural semelhante, assim a grande diferença que afeta a qualidade da água, entre os dois cursos d´águas é a poluição urbana, na cidade de Botucatu (ribeirão Lavapés). Deste modo procurou-se avaliar a contribuição de nutrientes (fósforo e nitrogênio) do ribeirão Lavapés e rio Capivara na represa de Barra Bonita , e estimar a carga retida no lodo do ribeirão Lavapés e a despejada na represa em função dos lançamentos de esgotos sanitários no mesmo, na cidade de Botucatu. O trabalho foi realizado em um período de seca, sem alagamentos, o que permitiu medir as vazões próximas da foz e avaliar a carga diária, no período, de nutrientes lançados na represa. Foram avaliados também, oxigênio dissolvido, demanda química do oxigênio e condutividade Elétrica. Embora os resultados sejam estimativos e variáveis no tempo, podemos concluir que a poluição na cidade de Botucatu por esgoto sanitário além de inviabilizar o uso da água no seu percurso, e causar outros prejuízos, contribui para agravar a eutrofização na represa de Barra Bonita.
Resumo:
Oxigênio dissolvido (OD), demanda bioquímica do oxigênio (DBO) e demanda química do oxigênio (DQO) foram utilizados como parâmetros para se avaliar o grau e capacidade de autodepuração do ribeirão Lavapés, que atravessa a cidade de Botucatu - SP. Avaliou-se o perfil de poluição orgânica e identificadas as zonas de autodepuração, e pontualmente foi realizado uma coleta de 24 horas, de hora em hora, onde foi possível correlacionar a poluição orgânica com as atividades domésticas. A DQO mostrou-se como a melhor técnica para avaliar o perfil de poluição orgânica, identificar as zonas de depuração, e para avaliar a poluição orgânica, neste curso d água. A relação DQO/DBO foi em média 3,4 caracterizando um esgoto biodegradável, indicando que praticamente não existe adição de efluentes industriais, permitindo assim estimar a DBO através da DQO. Nos trechos de água limpa, nascente e foz, em que a DQO estava abaixo de 5 mg L-1 O2, foram utilizados os valores de oxigênio consumido (método do permanganato), o que não invalidou a identificação das zonas de depuração. No entanto pesquisas para desenvolver o método de DQO (dicromato) para baixas concentrações, abaixo de 5 mg L-1 são necessárias para uma melhor avaliação da recuperação do curso d água.
Resumo:
Foi obtido o balanço de massa, a partir dos valores médios das determinações de demanda química de oxigênio (DQO) e produção de metano (CH4), em dois reatores UASB de bancada com volume de 10,5 L tratando águas residuárias de suinocultura, submetidos a condições operacionais distintas no que diz respeito às concentrações de sólidos suspensos totais do afluente (SST de 500; 1.000; 1.500 e 2.000 mg L-1), tempo de detenção hidráulica (TDH de 30; 20; 12 e 8 h), taxas de carregamento orgânico volumétrico (TCOV de 0,8 a 8,0 kg DQO total (m³ d)-1) e temperatura (ambiente e controlada a 25º e 30ºC). Verificou-se que a DQO total removida convertida em CH4 variou de 28 a 51% e a relação DQO-CH4 por DQO dissolvida removida de 0,94 a 2,07; indicando alta participação da remoção física dos sólidos do afluente, de 49 a 72%, na remoção de DQO total nos reatores, a qual variou de 75 a 92%. A concentração de SST do afluente, a temperatura, o TDH e a TCOV influenciaram nesse desempenho dos reatores UASB.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)