987 resultados para CLEAN AIR ACTS
Resumo:
Wollongong, Australia is an urban site at the intersection of anthropogenic, biomass burning, biogenic and marine sources of atmospheric trace gases. The location offers a valuable opportunity to study drivers of atmospheric composition in the Southern Hemisphere. Here, a record of surface carbon monoxide (CO), methane (CH4) and carbon dioxide (CO2) was measured with an in situ Fourier transform infrared trace gas analyser between April 2011 and August 2014. Clean air was found to arrive at Wollongong in approximately 10% of air masses. Biomass burning influence was evident in the average annual cycle of clean air CO during austral spring. A significant negative short-term trend was found in clean air CO (-1.5 nmol/mol/a), driven by a reduction in northern Australian biomass burning. Significant short-term positive trends in clean air CH4 (5.4 nmol/mol/a) and CO2 (1.9 ?mol/mol/a) were consistent with the long-term global average trends. Polluted Wollongong air was investigated using wind-direction/wind-speed clustering, which revealed major influence from local urban and industrial sources from the south. High values of CH4, with anthropogenic DCH4/DCO2 enhancement ratio signatures, originated from the northwest, in the direction of local coal mining. A pollution climatology was developed for the region using back trajectory analysis and DO3/DCO enhancement ratios. Ozone production environments in austral spring and summer were associated with anticyclonic meteorology on the east coast of Australia, while ozone depletion environments in autumn and winter were associated with continental transport, or fast moving trajectories from southern latitudes. This implies the need to consider meteorological conditions when developing policies for controlling air quality.
Resumo:
Ozone (O3) phytotoxicity has been reported on a wide range of plant species. However, scarce information has been provided regarding the sensitivity of semi-natural grassland species, especially those from dehesa Mediterranean grasslands, in spite of their great biological diversity and the high O3 levels recorded in the region. A screening study was carried out in open-top chambers (OTCs) to assess the O3-sensitivity of representative therophytes of these ecosystems based on the response of selected growth-related parameters. Three O3 treatments and 3 OTCs per treatment were used. Legume species were very sensitive to O3, because 78% of the tested species showed detrimental effects on their total biomass relative growth rate (RGR) following their exposure to O3. The Trifolium genus was particularly sensitive showing O3-induced adverse effects on most of the assessed parameters. Gramineae plants were less sensitive than Leguminosae species because detrimental effects on total biomass RGR were only observed in 14% of the assessed species. No relationship was found between relative growth rates when growing in clean air and O3 susceptibility. The implications of these effects on the performance of dehesa acidic grasslands and on the definition of ozone critical levels for the protection of semi-natural vegetation are discussed.
Resumo:
La edificación residencial existente en España y en Europa se encuentra abocada a una rehabilitación profunda para cumplir los objetivos marcados en la estrategia europea para el año 2050. Estos, para el sector de la edificación, se proponen una reducción del 90% de emisiones de gases de efecto invernadero (GEI) respecto a niveles del año 1990. Este plan a largo plazo establece hitos intermedios de control, con objetivos parciales para el año 2020 y 2030. El objetivo último es aprovechar el potencial de reducción de demanda energética del sector de la edificación, del cual la edificación residencial supone el 85% en España. Dentro de estos requerimientos, de reducción de demanda energética en la edificación, la ventilación en la edificación residencial se convierte en uno de los retos a resolver por su vinculación directa a la salud y el confort de los ocupantes de la misma, y al mismo tiempo su relación proporcional con la demanda energética que presenta el edificio asociada al acondicionamiento térmico. Gran parte de las pérdidas térmicas de la edificación residencial se producen por el aire de renovación y la infiltración de aire a través de la envolvente. La directiva europea de eficiencia energética de la edificación (EPBD), que establece las directrices necesarias para alcanzar los objetivos de este sector en cuanto a emisiones de CO2 y gases de efecto invernadero (GEI), contempla la ventilación con aire limpio como un requisito fundamental a tener en cuenta de cara a las nuevas construcciones y a la rehabilitación energética de los edificios existentes. El síndrome del edificio enfermo, un conjunto de molestias y síntomas asociados a la baja calidad del aire de edificios no residenciales que surgió a raíz de la crisis del petróleo de 1973, tuvo su origen en una ventilación deficiente y una renovación del aire interior insuficiente de estos edificios, producto del intento de ahorro en la factura energética. Teniendo en cuenta que, de media, pasamos un 58% de nuestro tiempo en las viviendas, es fundamental cuidar la calidad del aire interior y no empeorarla aplicando medidas de “eficiencia energética” con efectos no esperados. Para conseguir esto es fundamental conocer en profundidad cómo se produce la ventilación en la edificación en bloque en España en sus aspectos de calidad del aire interior y demanda energética asociada a la ventilación. El objetivo de esta tesis es establecer una metodología de caracterización y de optimización de las necesidades de ventilación para los espacios residenciales existentes en España que aúne el doble objetivo de garantizar la calidad ambiental y reducir la demanda energética de los mismos. La caracterización del parque edificatorio residencial español en cuanto a ventilación es concluyente: La vivienda en España se distribuye principalmente en tres periodos en los que se encuentran más del 80% del total de las viviendas construidas. El periodo anterior a las normas básicas de la edificación (NBE), de 1960 a 1980, el periodo desde 1980 al año 2005, con el mayor número total de viviendas construidas, guiado por la NTE ISV 75, y el periodo correspondiente a la edificación construida a partir del Código Técnico de la Edificación, en 2006, cuyo documento básico de condiciones de salubridad (DB HS3) es la primera norma de obligado cumplimiento en diseño y dimensionamiento de ventilación residencial en España. La selección de un modelo de bloque de viviendas de referencia, un valor medio y representativo, seleccionado de entre estos periodos, pero con cualidades que se extienden más allá de uno de ellos, nos permite realizar un intensivo análisis comparativo de las condiciones de calidad de aire interior y la demanda energética del mismo, aplicando las distintas configuraciones que presenta la ventilación en viviendas dependiendo del escenario o época constructiva (o normativa) en que esta fuera construida. Este análisis se lleva a cabo apoyándose en un doble enfoque: el modelado numérico de simulaciones y el análisis de datos experimentales, para comprobar y afinar los modelos y observar la situación real de las viviendas en estos dos aspectos. Gracias a las conclusiones del análisis previo, se define una estrategia de optimización de la ventilación basada fundamentalmente en dos medidas: 1) La introducción de un sistema de extracción mecánica y recuperación de calor que permita reducir la demanda energética debida a la renovación del aire y a la vez diluir los contaminantes interiores más eficazmente para mejorar, de esta forma, la calidad del ambiente interior. 2) La racionalización del horario de utilización de estos sistemas, no malgastando la energía en periodos de no ocupación, permitiendo una leve ventilación de fondo, debida a la infiltración, que no incida en pérdidas energéticas cuantiosas. A esta optimización, además de aplicar la metodología de análisis previo, en cuanto a demanda energética y calidad del aire, se aplica una valoración económica integradora y comparativa basada en el reglamento delegado EU244/2012 de coste óptimo (Cost Optimal Methodology). Los resultados principales de esta tesis son: • Un diagnóstico de la calidad del aire interior de la edificación residencial en España y su demanda energética asociada, imprescindible para lograr una rehabilitación energética profunda garantizando la calidad del aire interior. • Un indicador de la relación directa entre calidad de aire y demanda energética, para evaluar la adecuación de los sistemas de ventilación, respecto de las nuevas normativas de eficiencia energética y ventilación. • Una estrategia de optimización, que ofrece una alternativa de intervención, y la aplicación de un método de valoración que permite evaluar la amortización comparada de la instalación de los sistemas. ABSTRACT The housing building stock already built in Spain and Europe faces a deep renovation in the present and near future to accomplish with the objectives agreed in the European strategy for 2050. These objectives, for the building sector, are set in a 90% of Green House Gases (GHG) reduction compared to levels in 1990. This long‐term plan has set milestones to control the correct advance of achievement in 2020 and 2030. The main objective is to take advantage of the great potential to reduce energy demand from the building sector, in which housing represents 85% share in Spain. Among this reduction on building energy demand requirements, ventilation of dwellings becomes one of the challenges to solve as it’s directly connected to the indoor air quality (IAQ) and comfort conditions for the users, as well as proportional to the building energy demand on thermal conditioning. A big share of thermal losses in housing is caused by air renovation and infiltration through the envelope leaks. The European Directive on Building energy performance (EPBD), establishes the roots needed to reach the building sector objectives in terms of CO2 and GHG emissions. This directive sets the ventilation and renovation with clean air of the new and existing buildings as a fundamental requirement. The Sick Building Syndrome (SBS), an aggregation of symptoms and annoys associated to low air quality in non residential buildings, appeared as common after the 1973 oil crisis. It is originated in defective ventilation systems and deficient air renovation rates, as a consequence of trying to lower the energy bill. Accounting that we spend 58% of our time in dwellings, it becomes crucial to look after the indoor air quality and focus in not worsening it by applying “energy efficient” measures, with not expected side effects. To do so, it is primary to research in deep how the ventilation takes place in the housing blocks in Spain, in the aspects related to IAQ and ventilation energy demand. This thesis main objective is to establish a characterization and optimization methodology regarding the ventilation needs for existing housing in Spain, considering the twofold objective of guaranteeing the air quality as reducing the energy demand. The characterization of the existing housing building stock in Spain regarding ventilation is conclusive. More of 80% of the housing stock is distributed in 3 main periods: before the implementation of the firsts regulations on building comfort conditions (Normas Básicas de la Edificación), from 1960 to 1980; the period after the first recommendations on ventilation (NTE ISV 75) for housing were set, around 1980 until 2005 and; the period corresponding to the housing built after the existing mandatory regulation in terms of indoor sanity conditions and ventilation (Spanish Building Code, DB HS3) was set, in 2006. Selecting a representative blueprint of a housing block in Spain, which has medium characteristics not just within the 3 periods mention, but which qualities extent beyond the 3 of them, allows the next step, analyzing. This comparative and intense analyzing phase is focused on the air indoor conditions and the related energy demand, applying different configurations to the ventilation systems according to the different constructive or regulation period in which the building is built. This analysis is also twofold: 1) Numerical modeling with computer simulations and 2) experimental data collection from existing housing in real conditions to check and refine the models to be tested. Thanks to the analyzing phase conclusions, an optimization strategy on the ventilation of the housing stock is set, based on two actions to take: 1) To introduce a mechanical exhaust and intake ventilation system with heat recovery that allows reducing energy demand, as improves the capacity of the system to dilute the pollutant load. This way, the environmental quality is improved. 2) To optimize the schedule of the system use, avoids waste of energy in no occupancy periods, relying ventilation during this time in a light infiltration ventilation, intended not to become large and not causing extra energy losses. Apart from applying the previous analyzing methodology to the optimization strategy, regarding energy demand and air quality, a ROI valorization is performed, based on the cost optimal methodology (delegated regulation EU244/2012). The main results from the thesis are: • To obtain a through diagnose regarding air quality and energy demand for the existing housing stock in Spain, unavoidable to reach a energy deep retrofitting scheme with no air quality worsening. • To obtain a marker to relate air quality and energy demand and evaluate adequateness of ventilation systems, for the new regulations to come. • To establish an optimization strategy to improve both air quality and energy demand, applying a compared valorization methodology to obtain the Return On Investment (ROI).
Resumo:
Introdução A poluição do ar é um fator de risco associado com descompensação e mortalidade em pacientes com insuficiência cardíaca (IC). Objetivo Avaliar o impacto de um filtro de polipropileno sobre desfechos cardiovasculares em pacientes com IC e voluntários saudáveis durante exposição controlada à poluição. Métodos Ensaio clínico duplocego, controlado e cruzado, incluindo 26 pacientes com IC e 15 voluntários saudáveis, expostos a três protocolos diferentes de inalação randomizados por ordem: Ar Limpo; Exposição à Partículas de Exaustão do Diesel (ED); e ED filtrada. Os desfechos estudados foram função endotelial por índice de hiperemia reativa (RHi) e índice de aumento (Aix), biomarcadores séricos, variáveis de teste cardiopulmonar submáximo (caminhada de seis-minutos [tc6m]; consumo de oxigênio [VO2]; equivalente ventilatório de gás carbônico [VE/VCO2 slope]; consumo de O2 por batida [PulsoO2]) e variabilidade da frequência cardíaca (VFC). Resultados No grupo IC, a ED piorou o RHi [de 2,17 (IQR: 1,8-2,5) para 1,72 (IQR: 1,5-2,2); p=0,002], reduziu o VO2 [de 11.0 ± 3.9 para 8.4±2.8ml/Kg/min; p < 0.001], o tc6m [de 243,3±13 para 220,8 ± 14m; p=0,030] e o PulsoO2 [de 8.9 ± 1.0 para 7.8±0.7ml/bpm; p < 0.001]; e aumentou o BNP [de 47,0pg/ml (IQR: 17,3-118,0) para 66,5pg/ml (IQR: 26,5-155,5); p=0,004]. O filtro foi capaz de reduzir a concentração de poluição de 325±31 para 25±6?g/m3 (p < 0,001 vs. ED). No grupo IC, o filtro foi associado com melhora no RHi [2,06 (IQR: 1,5-2,6); p=0,019 vs. ED); aumento no VO2 (10.4 ± 3.8ml/Kg/min; p < 0.001 vs. ED) e PulsoO2 (9.7±1.1ml/bpm; p < 0.001 vs. ED); e redução no BNP [44,0pg/ml (IQR: 20,0-110,0); p=0,015 vs. ED]. Em ambos os grupos, a ED reduziu o Aix, sem efeito do filtro. O uso do filtro foi associado com maior ventilação e reinalação de CO2. Outras variáveis pesquisadas como VE/VCO2 slope e VFC não sofreram influências entre os protocolos. Conclusão A poluição do ar afetou adversamente o desempenho cardiovascular de pacientes com IC. Este é o primeiro ensaio clínico demonstrando que um simples filtrorespiratório pode prevenir a disfunção endotelial, a intolerância ao exercício e o aumento do BNP associados à poluição em pacientes com IC. O uso de máscaras com filtro tem o potencial de reduzir a morbidade associada à IC. Identificador ClinicalTrials.gov: NCT01960920
Resumo:
In 2009, President Obama pledged that, by 2020, the United States would achieve reductions in greenhouse gas emissions of 17% from 2005 levels. With the failure of Congress to adopt comprehensive climate legislation in 2010, the feasibility of the pledge was put in doubt. However, we find that the United States is near to reaching this goal: the country is currently on course to achieve reductions of 16.3% from 2005 levels in 2020. Three factors contribute to this outcome: greenhouse gas regulations under the Clean Air Act, secular trends including changes in relative fuel prices and energy efficiency and sub-national efforts. Perhaps even more surprising, domestic emissions are probably lower than would have been the case if the Waxman-Markey cap-and-trade proposal had become law in 2010. At this point, however, the United States is expected to fail to meet its financing commitments under the Copenhagen Accord for 2020.
Resumo:
"PB93-145837."
Resumo:
"November 24, 1981"--Pt. 3.
Resumo:
O objetivo principal da pesquisa encetada foi o de ressaltar a importância do discurso de Ellen White, uma importante líder religiosa do século XIX, nos Estados Unidos da América, para a formação de um estilo e prática de vida, que ainda hoje caracteriza os adventistas do sétimo dia no que se refere a saúde. Outro, não menos importante objetivo, foi o de comparar os principais conceitos de Ellen White sobre saúde e estilo de vida com algumas preocupações científicas e acadêmicas contemporâneas. Para isso, este trabalho mostra como a lista de oito remédios naturais propostos por White sumarizam o ideal de uma vida saudável ainda praticada por milhões de adventistas, 100 anos após a morte de sua Profetiza: ar puro, água, alimentação adequada, luz solar, exercícios físicos, repouso, abstinência, e confiança em Deus. Os conselhos de White foram contrastados com várias práticas culturais que relacionam religião e saúde, levando-nos à conclusão que a cultura adventista tem se mostrado como a mais adequada na salvaguarda da saúde. Isto porque White apresentou uma síntese de elementos da cultura judaica, cristã e ocidental. Nesse sentido, as suas orientações garantem-lhe um lugar privilegiado no movimento de reforma da saúde nos Estados Unidos que ocorreu naquele País na segunda metade do século XIX. Muitos de seus conselhos estão sendo atualmente colocados em prática por todos aqueles que se preocupam com a saúde, longevidade, e a adequação do estilo de vida com as regras inspiradas na natureza e numa espiritualidade sadia.
Resumo:
Nanotechnologies have been called the "Next Industrial Revolution." At the same time, scientists are raising concerns about the potential health and environmental risks related to the nano-sized materials used in nanotechnologies. Analyses suggest that current U.S. federal regulatory structures are not likely to adequately address these risks in a proactive manner. Given these trends, the premise of this paper is that state and local-level agencies will likely deal with many "end-of-pipe" issues as nanomaterials enter environmental media without prior toxicity testing, federal standards, or emissions controls. In this paper we (1) briefly describe potential environmental risks and benefits related to emerging nanotechnologies; (2) outline the capacities of the Toxic Substances Control Act, the Clean Air Act, the Clean Water Act, and the Resources Conservation and Recovery Act to address potential nanotechnology risks, and how risk data gaps challenge these regulations; (3) outline some of the key data gaps that challenge state-level regulatory capacities to address nanotechnologies' potential risks, using Wisconsin as a case study; and (4) discuss advantages and disadvantages of state versus federal approaches to nanotechnology risk regulation. In summary, we suggest some ways government agencies can be better prepared to address nanotechnology risk knowledge gaps and risk management.
Resumo:
Objectionable odors remain at the top of air pollution complaints in urban areas such as Broward County that is subject to increasing residential and industrial developments. The odor complaints in Broward County escalated by 150 percent for the 2001 to 2004 period although the population increased by only 6 percent. It is estimated that in 2010 the population will increase to 2.5 million. Relying solely on enforcing the local odor ordinance is evidently not sufficient to manage the escalating odor complaint trends. An alternate approach similar to odor management plans (OMPs) that are successful in managing major malodor sources such as animal farms is required. ^ This study aims to develop and determine the feasibility of implementing a comprehensive odor management plan (COMP) for the entire Broward County. Unlike existing OMPs for single sources where the receptors (i.e. the complainants) are located beyond the boundary of the source, the COMP addresses a complex model of multiple sources and receptors coexisting within the boundary of the entire county. Each receptor is potentially subjected to malodor emissions from multiple sources within the county. Also, the quantity and quality of the source/receptor variables are continuously changing. ^ The results of this study show that it is feasible to develop a COMP that adopts a systematic procedure to: (1) Generate maps of existing odor complaint areas and malodor sources, (2) Identify potential odor sources (target sources) responsible for existing odor complaints, (3) Identify possible odor control strategies for target sources, (4) Determine the criteria for implementing odor control strategies, (5) Develop an odor complaint response protocol, and (6) Conduct odor impact analyses for new sources to prevent future odor related issues. Geographic Information System (GIS) is used to identify existing complaint areas. A COMP software that incorporates existing United States Environmental Protection Agency (EPA) air dispersion software is developed to determine the target sources, predict the likelihood of new complaints, and conduct odor impact analysis. The odor response protocol requires pre-planning field investigations and conducting surveys to optimize the local agency available resources while protecting the citizen's welfare, as required by the Clean Air Act. ^