950 resultados para CADMIUM TELLURIDE DETECTORS
Resumo:
We quickly form first impressions about newly encountered people guiding our subsequent behaviour (approach, avoidance). Such instant judgments might be innate and automatic, being performed unconsciously and independently to other cognitive processes. Lying detection might be subject to such a modular process. Unfortunately, numerous studies highlighted problems with lying detection paradigms such as high error rates and learning effects. Additionally, humans should be motivated doing both detecting others' lies and dis- guising own lies. Disguising own lies might even be more challenging than detecting other people's lies. Thus, when trying to disguise cheating behaviour, liars might display a mixture of disguising (fake) trust cues and uncontrolled lying cues making the interpretation of the expression difficult (perceivers are guessing). In two consecutive online studies, we tested whether seeing an increasing amount (range 0-4) of lying cues (LC) and non-lying cues (NLC) on a standard face results in enhanced guessing behaviour (studies 1 and 2) and that enhanced guessing is accompanied by slower responding (study 2). Results showed that pronounced guessing and slowest responding occurred for faces with an intermediate number and not with the highest number of LC and NLC. In particular, LC were more impor- tant than NLC to uncertain lying decisions. Thus, only a few LC may interfere with automatic processing of lying detection (irrespective of NLC), probably because too little lying cue information is yet available.
Resumo:
Experiments were conducted with adult male rats to investigate the effects of dietary calcium (Ca) restriction upon intake and tissue distribution of cadmium (Cd), and Cd-metallothionein (Mt) synthesis. Four groups of animals were fed either a low-Ca, semisynthetic diet (0.1% Ca) or the same diet supplemented with 0.8% Ca (normal diet). The caloric intake was similar in all groups. Two groups (low-Ca and normal diet) were used as controls, and two groups (low-Ca and normal diet) received 100 mg/l Cd (as CdCl2) in drinking water. Cd levels in liver, kidney, spleen and red cells were measured in all animals after 8 weeks of treatment. Concomitantly, Mt levels in plasma, liver and kidney were evaluated by radioimmunoassay. Ca deficiency entailed marked and significant increases in accumulation of Cd and synthesis of Mt in all assayed tissues. It is concluded that dietary Ca restriction, independent of caloric intake, enhances Cd intestinal absorption and tissue accumulation, which is followed by increased tissue Mt synthesis.
Cadmium uptake and induction of metallothionein synthesis in a renal epithelial cell line (LLC-PK1).
Resumo:
LLC-PK1 cells, an established cell line from pig kidney with proximal tubule properties, were cultivated in vitro at confluence on plastic dishes. They were then exposed (apical side) to inorganic cadmium (CdCl2, 5 microM) for periods ranging between 1 to 24 h. Analysis of the cell supernatant after homogenisation and ultracentrifugation indicated that Cd taken up in the first 3 h was bound to cytosolic high molecular weight proteins, but was redistributed to low molecular weight proteins at later stages. Induction of Cd-metallothionein (Cd-Mt) synthesis, as judged from Cd-Mt binding to a specific anti-Cd-Mt antibody and from the rate of 35S-cys incorporation into a specific protein fraction, was apparent 3-6 h after the addition of Cd to the incubation medium.
Resumo:
Free-flow micropuncture was carried out in superficial nephrons of Munich-Wistar type rats infused acutely with Cd acetate (CdA) or Cd-DTPA (141 microM Cd). Fluid obtained from Bowman's space (BS) or end-proximal tubule sites was analyzed for Cd and inulin. The fluid/plasma Cd concentration ratio in BS averaged 0.2 and 1.0 during CdA and Cd-DTPA infusions, respectively. End-proximal tubule fractional excretion of Cd during CdA infusion averaged 0.34. Previous administration of CdA (1.0 mg/kg, 48 hr before micropuncture) increased the level of circulating Cd-metallothioneins, as measured by radioimmunoassay, but did not affect the luminal tubular uptake of Cd during CdA infusion. No net transepithelial movement of Cd-DTPA was measured. It is concluded that Cd ultrafiltered during inorganic Cd administration is taken up to a large extent by the convoluted part of proximal tubules.
Resumo:
109Cd was injected into the lumen of superficial proximal or distal tubules of rat kidneys, and recovery in the pelvic urine from the ipsilateral kidney was measured. Fractional recovery of labeled inulin always exceeded 90%. About 70% of injected inorganic Cd (CdCl2) was taken up by the epithelium of proximal tubules, while more than 90% of the injected amount was recovered after distal microinjection. The proximal fractional Cd uptake of a 1:1 (molar) Cd-L-cysteine complex was 82%, but was below 60% for a 5-10:1 molar ratio of cysteine:Cd. The chelate Cd-pentetic acid was recovered in final urine nearly quantitatively after proximal or distal microinjection. Fractional uptake of 109Cd from a Cd-metallothionein (Mt) complex, following proximal microinjection, ranged between 17 (Cd-Mt 0.19 mM) and 8% (Cd-Mt 1.5 mM). It is concluded that luminal Cd uptake by the tubular epithelium depends markedly on the chemical form of Cd and, when present, occurs mostly or exclusively in proximal tubules.
Resumo:
When the compounds are heated in an inert atmosphere it can be verified the consecutive partial sublimation, fusion, partial volatilization and partial thermal decomposition of the anhydrous complexes. When in an oxidating atmosphere the above process is only verified to Cu(II) chelates. Anhydrous copper(II) complexes present a monoclinic structure in the b form and the volatilized compound in a a form. Zinc(II) and cadmium(II) hydrated complexes are isomorphous and they present different cell dimensions from those reported previously.
Resumo:
Large Hadron Collider (LHC) is the main particle accelerator at CERN. LHC is created with main goal to search elementary particles and help science investigate our universe. Radiation in LHC is caused by charged particles circular acceleration, therefore detectors tracing particles in existed severe conditions during the experiments must be radiation tolerant. Moreover, further upgrade of luminosity (up to 1035 cm-2s-1) requires development of particle detector’s structure. This work is dedicated to show the new type 3D stripixel detector with serious structural improvement. The new type of radiation-hard detector has a three-dimensional (3D) array of the p+ and n+ electrodes that penetrate into the detector bulk. The electrons and holes are then collected at oppositely biased electrodes. Proposed 3D stripixel detector demonstrates that full depletion voltage is lower that that for planar detectors. Low depletion voltage is one of the main advantages because only depleted part of the device is active are. Because of small spacing between electrodes, charge collection distances are smaller which results in high speed of the detector’s response. In this work is also briefly discussed dual-column type detectors, meaning consisting both n+ and p+ type columnar electrodes in its structure, and was declared that dual-column detectors show better electric filed distribution then single sided radiation detectors. The dead space or in other words low electric field region in significantly suppressed. Simulations were carried out by using Atlas device simulation software. As a simulation results in this work are represented the electric field distribution under different bias voltages.
Resumo:
The spectrophotometric determination of Cd(II) using a flow injection system provided with a solid-phase reactor for cadmium preconcentration and on-line reagent preparation, is described. It is based on the formation of a dithizone-Cd complex in basic medium. The calibration curve is linear between 6 and 300 µg L-1 Cd(II), with a detection limit of 5.4 µg L-1, an RSD of 3.7% (10 replicates in duplicate) and a sample frequency of 11.4 h-1. The proposed method was satisfactorily applied to the determination of Cd(II) in surface, well and drinking waters.
Resumo:
The high sensitivity and excellent timing accuracy of Geiger mode avalanche photodiodes makes them ideal sensors as pixel detectors for particle tracking in high energy physics experiments to be performed in future linear colliders. Nevertheless, it is well known that these sensors suffer from dark counts and afterpulsing noise, which induce false hits (indistinguishable from event detection) as well as an increase of the necessary area of the readout system. In this work, we present a comparison between APDs fabricated in a high voltage 0.35 µm and a high integration 0.13 µm commercially available CMOS technologies that has been performed to determine which of them best fits the particle collider requirements. In addition, a readout circuit that allows low noise operation is introduced. Experimental characterization of the proposed pixel is also presented in this work.
Resumo:
The effects of pre-incubation with mercury (Hg2+) and cadmium (Cd2+) on the activities of individual glycolytic enzymes, on the flux and on internal metabolite concentrations of the upper part of glycolysis were investigated in mouse muscle extracts. In the range of metal concentrations analysed we found that only hexokinase and phosphofructokinase, the enzymes that shared the control of the flux, were inhibited by Hg2+ and Cd2+. The concentrations of the internal metabolites glucose-6-phosphate and fructose-6-phosphate did not change significantly when Hg2+ and Cd2+ were added. A mathematical model was constructed to explore the mechanisms of inhibition of Hg2+ and Cd2+ on hexokinase and phosphofructokinase. Equations derived from detailed mechanistic models for each inhibition were fitted to the experimental data. In a concentration-dependent manner these equations describe the observed inhibition of enzyme activity. Under the conditions analysed, the integral model showed that the simultaneous inhibition of hexokinase and phosphofructokinase explains the observation that the concentrations of glucose-6-phosphate and fructose-6-phosphate did not change as the heavy metals decreased the glycolytic flux.
Resumo:
In the proposed method, carbon tetrachloride and ethanol were used as extraction and dispersive solvents. Several factors that may be affected on the extraction process, such as extraction solvent, disperser solvent, the volume of extraction and disperser solvent, pH of the aqueous solution and extraction time were optimized. Under the optimal conditions, linearity was maintained between 1.0 ng mL-1 to 1.5 mg mL-1 for zinc and 1.0 ng mL-1 to 0.4 mg mL-1 for cadmium. The proposed method has been applied for determination of trace amount of zinc and cadmium in standard and water samples with satisfactory results.
Resumo:
A simple, sensitive and selective cloud point extraction procedure is described for the preconcentration and atomic absorption spectrometric determination of Zn2+ and Cd2+ ions in water and biological samples, after complexation with 3,3',3",3'"-tetraindolyl (terephthaloyl) dimethane (TTDM) in basic medium, using Triton X-114 as nonionic surfactant. Detection limits of 3.0 and 2.0 µg L-1 and quantification limits 10.0 and 7.0 µg L-1were obtained for Zn2+ and Cd2+ ions, respectively. Relative standard deviation was 2.9 and 3.3, and enrichment factors 23.9 and 25.6, for Zn2+ and Cd2+ ions, respectively. The method enabled determination of low levels of Zn2+ and Cd2+ ions in urine, blood serum and water samples.
Resumo:
Solid-state silicon detectors have replaced conventional ones in almost all recent high-energy physics experiments. Pixel silicon sensors don't have any alternative in the area near the interaction point because of their high resolution and fast operation speed. However, present detectors hardly withstand high radiation doses. Forthcoming upgrade of the LHC in 2014 requires development of a new generation of pixel detectors which will be able to operate under ten times increased luminosity. A planar fabrication technique has some physical limitations; an improvement of the radiation hardness will reduce sensitivity of a detector. In that case a 3D pixel detector seems to be the most promising device which can overcome these difficulties. The objective of this work was to model a structure of the 3D stripixel detector and to simulate electrical characteristics of the device. Silvaco Atlas software has been used for these purposes. The structures of single and double sided dual column detectors with active edges were described using special command language. Simulations of these detectors have shown that electric field inside an active area has more uniform distribution in comparison to the planar structure. A smaller interelectrode space leads to a stronger field and also decreases the collection time. This makes the new type of detectors more radiation resistant. Other discovered advantages are the lower full depletion voltage and increased charge collection efficiency. So the 3D stripixel detectors have demonstrated improved characteristics and will be a suitable replacement for the planar ones.