999 resultados para Bolus Volume


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. The purpose of this study was to investigate the effect of light-curing protocol on degree of conversion (DC), volume contraction (C), elastic modulus (E), and glass transition temperature (T(g)) as measured on a model polymer. It was a further aim to correlate the measured values with each other. Methods. Different light-curing protocols were used in order to investigate the influence of energy density (ED), power density (PD), and mode of cure on the properties. The modes of cure were continuous, pulse-delay, and stepped irradiation. DC was measured by Raman micro-spectroscopy. C was determined by pycnometry and a density column. E was measured by a dynamic mechanical analyzer (DMA), and T(g) was measured by differential scanning calorimetry (DSC). Data were submitted to two-and three-way ANOVA, and linear regression analyses. Results. ED, PD, and mode of cure influenced DC, C, E, and T(g) of the polymer. A significant positive correlation was found between ED and DC (r = 0.58), ED and E (r = 0.51), and ED and T(g) (r = 0.44). Taken together, ED and PD were significantly related to DC and E. The regression coefficient was positive for ED and negative for PD. Significant positive correlations were detected between DC and C (r = 0.54), DC and E (r = 0.61), and DC and T(g) (r = 0.53). Comparisons between continuous and pulse-delay modes of cure showed significant influence of mode of cure: pulse-delay curing resulted in decreased DC, decreased C, and decreased T(g). Influence of mode of cure, when comparing continuous and step modes of cure, was more ambiguous. A complex relationship exists between curing protocol, microstructure of the resin and the investigated properties. The overall performance of a composite is thus indirectly affected by the curing protocol adopted, and the desired reduction of C may be in fact a consequence of the decrease in DC. (C) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The diffusion model for percutaneous absorption is developed for the specific case of delivery to the skin being limited by the application of a finite amount of solute. Two cases are considered; in the first, there is an application of a finite donor (vehicle) volume, and in the second, there are solvent-deposited solids and a thin vehicle with a high partition coefficient. In both cases, the potential effect of an interfacial resistance at the stratum corneum surface is also considered. As in the previous paper, which was concerned with the application of a constant donor concentration, clearance limitations due to the viable eqidermis, the in vitro sampling rate, or perfusion rate in vivo are included. Numerical inversion of the Laplace domain solutions was used for simulations of solute flux and cumulative amount absorbed and to model specific examples of percutaneous absorption of solvent-deposited solids. It was concluded that numerical inversions of the Laplace domain solutions for a diffusion model of the percutaneous absorption, using standard scientific software (such as SCIENTIST, MicroMath Scientific software) on modern personal computers, is a practical alternative to computation of infinite series solutions. Limits of the Laplace domain solutions were used to define the moments of the flux-time profiles for finite donor volumes and the slope of the terminal log flux-time profile. The mean transit time could be related to the diffusion time through stratum corneum, viable epidermal, and donor diffusion layer resistances and clearance from the receptor phase. Approximate expressions for the time to reach maximum flux (peak time) and maximum flux were also derived. The model was then validated using reported amount-time and flux-time profiles for finite doses applied to the skin. It was concluded that for very small donor phase volume or for very large stratum corneum-vehicle partitioning coefficients (e.g., for solvent deposited solids), the flux and amount of solute absorbed are affected by receptor conditions to a lesser extent than is obvious for a constant donor constant donor concentrations. (C) 2001 Wiley-Liss, Inc. and the American Pharmaceutical Association J Pharm Sci 90:504-520, 2001.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to determine the pharmacokinetic profile of the normal recommended dose of ceftriaxone in critically ill patients and to establish whether the current daily dosing recommendation maintains plasma concentrations adequate for antibacterial efficacy. Ceftriaxone at a recommended dose of 2 g iv was administered od to 12 critically ill patients with severe sepsis and normal serum creatinine concentrations. Blood samples were taken at predetermined intervals over the first 24 h and on day 3 for measurement of ceftriaxone concentrations. There was wide variability in drug disposition, explained by the presence of variable renal function and identified by the measurement of creatinine clearance. In nine patients with normal renal function, there was a high level of creatinine clearance(mean +/- S.D., 41 +/- 12 mL/min) and volume of distribution (20 +/- 3.3 L), which resulted in an elimination half-life of 6.4 +/- 1.1 h. In comparison with normal subjects, ceftriaxone clearance was increased 100%, volume of distribution increased 90% and the elimination half-life was similar. Three patients had substantially suboptimal plasma ceftriaxone concentrations. We confirm previous findings that ceftriaxone clearance in critically ill patients correlates with renal clearance by glomerular filtration. The elimination half-life is prolonged (21.4 +/- 9.8 h) in critically ill patients with renal failure when compared with previously published data in non-critically ill patients with renal failure. We conclude that in critically ill patients with normal renal function, inadequate plasma concentrations may result following od bolus dosing of ceftriaxone. Drug accumulation may occur in critically ill patients with renal failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study we present a novel automated strategy for predicting infarct evolution, based on MR diffusion and perfusion images acquired in the acute stage of stroke. The validity of this methodology was tested on novel patient data including data acquired from an independent stroke clinic. Regions-of-interest (ROIs) defining the initial diffusion lesion and tissue with abnormal hemodynamic function as defined by the mean transit time (MTT) abnormality were automatically extracted from DWI/PI maps. Quantitative measures of cerebral blood flow (CBF) and volume (CBV) along with ratio measures defined relative to the contralateral hemisphere (r(a)CBF and r(a)CBV) were calculated for the MTT ROIs. A parametric normal classifier algorithm incorporating these measures was used to predict infarct growth. The mean r(a)CBF and r(a)CBV values for eventually infarcted MTT tissue were 0.70 +/-0.19 and 1.20 +/-0.36. For recovered tissue the mean values were 0.99 +/-0.25 and 1.87 +/-0.71, respectively. There was a significant difference between these two regions for both measures (P

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lateral ventricular volumes based on segmented brain MR images can be significantly underestimated if partial volume effects are not considered. This is because a group of voxels in the neighborhood of lateral ventricles is often mis-classified as gray matter voxels due to partial volume effects. This group of voxels is actually a mixture of ventricular cerebro-spinal fluid and the white matter and therefore, a portion of it should be included as part of the lateral ventricular structure. In this note, we describe an automated method for the measurement of lateral ventricular volumes on segmented brain MR images. Image segmentation was carried in combination of intensity correction and thresholding. The method is featured with a procedure for addressing mis-classified voxels in the surrounding of lateral ventricles. A detailed analysis showed that lateral ventricular volumes could be underestimated by 10 to 30% depending upon the size of the lateral ventricular structure, if mis-classified voxels were not included. Validation of the method was done through comparison with the averaged manually traced volumes. Finally, the merit of the method is demonstrated in the evaluation of the rate of lateral ventricular enlargement. (C) 2001 Elsevier Science Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A model for binary mixture adsorption accounting for energetic heterogeneity and intermolecular interactions is proposed in this paper. The model is based on statistical thermodynamics, and it is able to describe molecular rearrangement of a mixture in a nonuniform adsorption field inside a cavity. The Helmholtz free energy obtained in the framework of this approach has upper and lower limits, which define a permissible range in which all possible solutions will be found. One limit corresponds to a completely chaotic distribution of molecules within a cavity, while the other corresponds to a maximum ordered molecular structure. Comparison of the nearly ideal O-2-N-2-zeolite NaX system at ambient temperature with the system Of O-2-N-2-zeolite CaX at 144 K has shown that a decrease of temperature leads to a molecular rearrangement in the cavity volume, which results from the difference in the fluid-solid interactions. The model is able to describe this behavior and therefore allows predicting mixture adsorption more accurately compared to those assuming energetic uniformity of the adsorption volume. Another feature of the model is its ability to correctly describe the negative deviations from Raoult's law exhibited by the O-2-N-2-CaX system at 144 K. Analysis of the highly nonideal CO2-C2H6-zeolite NaX system has shown that the spatial molecular rearrangement in separate cavities is induced by not only the ion-quadrupole interaction of the CO2 molecule but also the significant difference in molecular size and the difference between the intermolecular interactions of molecules of the same species and those of molecules of different species. This leads to the highly ordered structure of this system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 4-cycle trade of volume t corresponds to a simple graph G without isolated vertices, where the edge set can be partitioned into t 4-cycles in at least two different ways such that the two collections of 4-cycles have no 4-cycles in common. The foundation of the trade is v = \V(G)\. This paper determines for which values oft and a there exists a 4-cycle trade of volume t and foundation v.