999 resultados para Blind Detection
Resumo:
A simple and easy approach to produce polymeric microchips with integrated copper electrodes for capacitively coupled contactless conductivity detection (CD) is described. Copper electrodes were fabricated using a printed circuit board (PCB) as an inexpensive thin-layer of metal. The electrode layout was first drawn and laser printed on a wax paper sheet. The toner layer deposited on the paper sheet was thermally transferred to the PCB surface working as a mask for wet chemical etching of the copper layer. After the etching step, the toner was removed with an acetonitrile-dampened cotton. A poly(ethylene terephthalate) (PET) film coated with a thin thermo-sensitive adhesive layer was used to laminate the PCB plate providing an insulator layer of the electrodes to perform CID measurements. Electrophoresis microchannels were fabricated in poly(dimethylsiloxane) (PDMS) by soft lithography and reversibly sealed against the PET film. These hybrid PDMS/PET chips exhibited a stable electroosmotic mobility of 4.25 +/- 0.04 x 10(-4) V cm(-2) s(-1), at pH 6.1, over fifty runs. Efficiencies ranging from 1127 to 1690 theoretical plates were obtained for inorganic cations.
Resumo:
Introduction: The purpose of this study was to compare the frequency and severity of perineal trauma during spontaneous birth with or without perineal injections of hyaluronidase (HAase). Methods: A randomized, placebo-controlled, double-blind clinical trial was conducted in a midwife-led, in-hospital birth center in Sao Paulo, Brazil. Primiparous women (N = 160) were randomly assigned to an experimental (n = 80) or control (n = 80) group. During the second stage of labor, women in the experimental group received an injection of 20.000 turbidity-reducing units of HAase in the posterior region of the perineum, and those in the control group received a placebo injection. The assessment of perineal outcome was performed by 2 independent nurse-midwives. A 1-tailed Fisher exact test was performed, and a P value < .025 was considered statistically significant. Results: Perineal integrity occurred in 34.2% of the experimental group and in 32.5% of the control group, which was not a statistically significant difference (P = .477). First-degree laceration was the most common trauma in the posterior region of the perineum in women in both groups (experimental = 56%, control = 42.6%). Severe perineal trauma occurred in 28.9% of the experimental group and 38.8% of the control group, which also was not a statistically significant difference (P =. 131). The depth of second-degree perineal lacerations in the experimental and control groups, measured by the Peri-Rule, was 1.9 cm and 2.3 cm, respectively. An episiotomy was performed in 11 women (experimental group = 3, control group = 8), and 4 (all in control group) had third-degree lacerations. Discussion: The use of injectable HAase did not increase the proportion of intact perineum and did not reduce the proportion of severe perineal trauma in our sample. J Midwifery Womens Health 2011; 56: 436-445 (C) 2011 by the American College of Nurse-Midwives.
Resumo:
Objective: to investigate the use of local anaesthetics, in the presence or absence of vasoconstrictors, for perineal repair during spontaneous delivery. Design: double-blind, randomised-controlled trial. Setting: a birth centre, in the city of Sao Paulo, Brazil. Participants: from June to December 2004, a total of 96 women were allocated into three groups (first-degree perineal lacerations, second-degree perineal lacerations or episiotomy), and treated with local anaesthesia (1% lidocaine or 1% lidocaine with epinephrine) (n = 16 per treatment per group). Interventions: an initial local infiltration of the anaesthetic solution was given so that episiotomy could be carried out (5 ml) and to suture spontaneous lacerations (1 ml), followed by repeated doses (1 ml) until pain was completely inhibited. Measurements and findings: the main outcome measurement was the volume of anaesthetic used during episiotomy and perineal suture. Our data suggest that the concomitant use of the vasoconstrictor resulted in a significantly lower average volume used in the treatment of first-degree (1 ml, 95% confidence interval (0) 0.4-1.6) and second-degree (3.7 ml, 95% CI 1.6-5.8) lacerations (p = 0.002 and 0.001, respectively). A 0.3 ml (95% CI 1.5-2.1) average decrease in anaesthetic volume was observed with episiotomy (p = 0.724). The maximum volume of anaesthetic used with and without vasoconstrictor was 1-2 ml in 95% and 3-4 ml in 50% of first-degree lacerations, respectively, and 1-6 ml in 88% and 7-15 ml in 81% of second-degree lacerations, respectively. For episiotomy, the maximum dose was 15 ml, regardless of anaesthetic solution used. Key conclusions: our data confirm the hypothesis that the use of anaesthetics in conjunction with vasoconstrictors is more effective than anaesthetics alone in the repair of perineal lacerations, but not for episiotomy. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
Background: Prevalence rates of smoking are rising in developing countries. Previous trials evaluating the efficacy and tolerability of the smoking-cessation medication varenicline have used largely participants of Caucasian origin. Objective: This study was conducted to evaluate the efficacy and tolerability of varenicline in populations of participants from Latin America, Africa, and the Middle East to investigate potential differences in the therapeutic response to varenicline. Methods: This multinational, randomized, double-blind, placebo-controlled trial was conducted at 42 centers in 11 countries (Latin America: Brazil, Colombia, Costa Rica, Mexico, and Venezuela; Africa: Egypt and South Africa; Middle East: Jordan, Lebanon, Saudi Arabia, and the United Arab Emirates). Participants were male and female smokers aged 18 to 75 years who were motivated to stop smoking; smoked >= 10 cigarettes/d, with no cumulative period of abstinence >3 months in the previous year; and who had no serious or unstable disease within the previous 6 months. Subjects were randomized in a 2:1 ratio to receive varenicline 1 mg or placebo, BID for 12 weeks, with a 12-week nontreatment follow-up. Brief smoking-cessation counseling was provided. The main outcome measures were carbon monoxide confirmed continuous abstinence rate (CAR) at weeks 9 to 12 and weeks 9 to 24. Adverse events (AEs) were recorded for tolerability assessment. Results: Overall, 588 subjects (varenicline, 390; placebo, 198) were randomized and treated. The mean (SD) ages of subjects in the varenicline and placebo groups were 43.1 (10.8) and 43.9 (10.8) years, respectively; 57.7% and 65.7% were male; and the mean (SD) weights were 75.0 (16.0) and 76.7 (16.3) kg (range, 40.0-130.0 and 45.6-126.0 kg). CAR at weeks 9 to 12 was significantly higher with varenicline than with placebo (53.59% vs 18.69%; odds ratio [OR] = 5.76; 95% CI, 3.74-8.88; P < 0.0001), and this rate was maintained during weeks 9 to 24 (39.74% vs 13.13%; OR = 4.78; 95% CI, 2.97-7.68; P < 0.0001). Nausea, headache, and insomnia were the most commonly reported AEs with varenicline and were reported numerically more frequently in the varenicline group compared with the placebo group. Serious AEs (SAEs) were reported in 2.8% of varenicline recipients compared with 1.0% in the placebo group, with 6 subjects reporting psychiatric SAEs compared with none in the placebo group. Conclusion: Based on these data, varenicline was apparently efficacious and generally well tolerated as a smoking-cessation aid in smokers from selected sites in Latin America, Africa, and the Middle East. ClinicalTrials. gov identifier: NCT00594204. (Clin Ther. 2011;33:465-477) (C) 2011 Published by Elsevier HS Journals, Inc.
Resumo:
Aims: To investigate the effects of a 6-month supplementation with calcium and cholecalciferol on biochemical parameters and muscle strength of institutionalized elderly. Methods: This prospective, double-blind, placebo-controlled, randomized trial included Brazilian institutionalized people 6 60 years of age receiving a 6-month supplementation ( December to May) of daily calcium plus monthly placebo (calcium/placebo group) or daily calcium plus oral cholecalciferol (150,000 IU once a month during the first 2 months, followed by 90,000 IU once a month for the last 4 months; calcium/vitamin D group). Fasting blood samples for 25-(OH) D, PTH and calcium determination were collected (n = 56) and muscle tests were performed ( n = 46) to measure the strength of hip flexors (SHF) and knee extensors (SKE) before ( baseline) and after the 6-month intervention ( 6 months). Results: Due to seasonal variations, serum 25( OH) D significantly enhanced in both groups after treatment, but the calcium/vitamin D group had significantly higher 25-(OH) D levels than the calcium/placebo group (84 vs. 33%, respectively; p < 0.0001). No cases of hypercalcemia were observed. While the calcium/placebo group showed no improvement in SHF and SKE at 6 months (p = 0.93 and p = 0.61, respectively), SHF was increased in the calcium/vitamin D group by 16.4% (p = 0.0001) and SKE by 24.6% (p = 0.0007). Conclusions: The suggested cholecalciferol supplementation was safe and efficient in enhancing 25(OH)D levels and lower limb muscle strength in the elderly, in the absence of any regular physical exercise practice. Copyright (C) 2009 S. Karger AG, Basel
Resumo:
Creatine (CR) supplementation is commonly used by athletes. However, its effects on renal function remain controversial. The aim of this study was to evaluate the effects of creatine supplementation on renal function in healthy sedentary males (18-35 years old) submitted to exercise training. A randomized, double-blind, placebo-controlled trial was performed. Subjects (n = 18) were randomly allocated to receive treatment with either creatine (CR) (similar to 10 g day(-1) over 3 months) or placebo (PL) (dextrose). All subjects undertook moderate intensity aerobic training, in three 40-min sessions per week, during 3 months. Serum creatinine, serum and urinary sodium and potassium were determined at baseline and at the end of the study. Cystatin C was assessed prior to training (PRE), after 4 (POST 4) and 12 weeks (POST 12). Cystatin C levels (mg L-1) (PRE CR: 0.82 +/- 0.09; PL: 0.88 +/- 0.07 vs. POST 12 CR: 0.71 +/- 0.06; PL: 0.75 +/- 0.09, P = 0.0001) were decreased over time, suggesting an increase in glomerular filtration rate. Serum creatinine decreased with training in PL but was unchanged with training in CR. No significant differences were observed within or between groups in other parameters investigated. The decrease in cystatin C indicates that high-dose creatine supplementation over 3 months does not provoke any renal dysfunction in healthy males undergoing aerobic training. In addition, the results suggest that moderate aerobic training per se may improve renal function.
Resumo:
This paper proposes a three-stage offline approach to detect, identify, and correct series and shunt branch parameter errors. In Stage 1 the branches suspected of having parameter errors are identified through an Identification Index (II). The II of a branch is the ratio between the number of measurements adjacent to that branch, whose normalized residuals are higher than a specified threshold value, and the total number of measurements adjacent to that branch. Using several measurement snapshots, in Stage 2 the suspicious parameters are estimated, in a simultaneous multiple-state-and-parameter estimation, via an augmented state and parameter estimator which increases the V - theta state vector for the inclusion of suspicious parameters. Stage 3 enables the validation of the estimation obtained in Stage 2, and is performed via a conventional weighted least squares estimator. Several simulation results (with IEEE bus systems) have demonstrated the reliability of the proposed approach to deal with single and multiple parameter errors in adjacent and non-adjacent branches, as well as in parallel transmission lines with series compensation. Finally the proposed approach is confirmed on tests performed on the Hydro-Quebec TransEnergie network.
Resumo:
The main purpose of this paper is to present architecture of automated system that allows monitoring and tracking in real time (online) the possible occurrence of faults and electromagnetic transients observed in primary power distribution networks. Through the interconnection of this automated system to the utility operation center, it will be possible to provide an efficient tool that will assist in decisionmaking by the Operation Center. In short, the desired purpose aims to have all tools necessary to identify, almost instantaneously, the occurrence of faults and transient disturbances in the primary power distribution system, as well as to determine its respective origin and probable location. The compilations of results from the application of this automated system show that the developed techniques provide accurate results, identifying and locating several occurrences of faults observed in the distribution system.
Resumo:
In this study, the innovation approach is used to estimate the measurement total error associated with power system state estimation. This is required because the power system equations are very much correlated with each other and as a consequence part of the measurements errors is masked. For that purpose an index, innovation index (II), which provides the quantity of new information a measurement contains is proposed. A critical measurement is the limit case of a measurement with low II, it has a zero II index and its error is totally masked. In other words, that measurement does not bring any innovation for the gross error test. Using the II of a measurement, the masked gross error by the state estimation is recovered; then the total gross error of that measurement is composed. Instead of the classical normalised measurement residual amplitude, the corresponding normalised composed measurement residual amplitude is used in the gross error detection and identification test, but with m degrees of freedom. The gross error processing turns out to be very simple to implement, requiring only few adaptations to the existing state estimation software. The IEEE-14 bus system is used to validate the proposed gross error detection and identification test.
Resumo:
On-line leak detection is a main concern for the safe operation of pipelines. Acoustic and mass balance are the most important and extensively applied technologies in field problems. The objective of this work is to compare these leak detection methods with respect to a given reference situation, i.e., the same pipeline and monitoring signals acquired at the inlet and outlet ends. Experimental tests were conducted in a 749 m long laboratory pipeline transporting water as the working fluid. The instrumentation included pressure transducers and electromagnetic flowmeters. Leaks were simulated by opening solenoid valves placed at known positions and previously calibrated to produce known average leak flow rates. Results have clearly shown the limitations and advantages of each method. It is also quite clear that acoustics and mass balance technologies are, in fact, complementary. In general, an acoustic leak detection system sends out an alarm more rapidly and locates the leak more precisely, provided that the rupture of the pipeline occurs abruptly enough. On the other hand, a mass balance leak detection method is capable of quantifying the leak flow rate very accurately and of detecting progressive leaks.
Resumo:
Leakage reduction in water supply systems and distribution networks has been an increasingly important issue in the water industry since leaks and ruptures result in major physical and economic losses. Hydraulic transient solvers can be used in the system operational diagnosis, namely for leak detection purposes, due to their capability to describe the dynamic behaviour of the systems and to provide substantial amounts of data. In this research work, the association of hydraulic transient analysis with an optimisation model, through inverse transient analysis (ITA), has been used for leak detection and its location in an experimental facility containing PVC pipes. Observed transient pressure data have been used for testing ITA. A key factor for the success of the leak detection technique used is the accurate calibration of the transient solver, namely adequate boundary conditions and the description of energy dissipation effects since PVC pipes are characterised by a viscoelastic mechanical response. Results have shown that leaks were located with an accuracy between 4-15% of the total length of the pipeline, depending on the discretisation of the system model.
Resumo:
In this paper, a framework for detection of human skin in digital images is proposed. This framework is composed of a training phase and a detection phase. A skin class model is learned during the training phase by processing several training images in a hybrid and incremental fuzzy learning scheme. This scheme combines unsupervised-and supervised-learning: unsupervised, by fuzzy clustering, to obtain clusters of color groups from training images; and supervised to select groups that represent skin color. At the end of the training phase, aggregation operators are used to provide combinations of selected groups into a skin model. In the detection phase, the learned skin model is used to detect human skin in an efficient way. Experimental results show robust and accurate human skin detection performed by the proposed framework.
Resumo:
Acoustic resonances are observed in high-pressure discharge lamps operated with ac input modulated power frequencies in the kilohertz range. This paper describes an optical resonance detection method for high-intensity discharge lamps using computer-controlled cameras and image processing software. Experimental results showing acoustic resonances in high-pressure sodium lamps are presented.
Resumo:
Sigma phase is a deleterious one which can be formed in duplex stainless steels during heat treatment or welding. Aiming to accompany this transformation, ferrite and sigma percentage and hardness were measured on samples of a UNS S31803 duplex stainless steel submitted to heat treatment. These results were compared to measurements obtained from ultrasound and eddy current techniques, i.e., velocity and impedance, respectively. Additionally, backscattered signals produced by wave propagation were acquired during ultrasonic inspection as well as magnetic Barkhausen noise during magnetic inspection. Both signal types were processed via a combination of detrended-fluctuation analysis (DFA) and principal component analysis (PCA). The techniques used were proven to be sensitive to changes in samples related to sigma phase formation due to heat treatment. Furthermore, there is an advantage using these methods since they are nondestructive. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
This paper reports the use of a non-destructive, continuous magnetic Barkhausen noise (CMBN) technique to investigate the size and thickness of volumetric defects, in a 1070 steel. The magnetic behavior of the used probe was analyzed by numerical simulation, using the finite element method (FEM). Results indicated that the presence of a ferrite coil core in the probe favors MBN emissions. The samples were scanned with different speeds and probe configurations to determine the effect of the flaw on the CMBN signal amplitude. A moving smooth window, based on a second-order statistical moment, was used for analyzing the time signal. The results show the technique`s good repeatability, and high capacity for detection of this type of defect. (C) 2009 Elsevier Ltd. All rights reserved.