965 resultados para Balloon catheter
Resumo:
Acute cardiovascular dysfunction occurs perioperatively in more than 20% of cardiosurgical patients, yet current acute heart failure (HF) classification is not applicable to this period. Indicators of major perioperative risk include unstable coronary syndromes, decompensated HF, significant arrhythmias and valvular disease. Clinical risk factors include history of heart disease, compensated HF, cerebrovascular disease, presence of diabetes mellitus, renal insufficiency and high-risk surgery. EuroSCORE reliably predicts perioperative cardiovascular alteration in patients aged less than 80 years. Preoperative B-type natriuretic peptide level is an additional risk stratification factor. Aggressively preserving heart function during cardiosurgery is a major goal. Volatile anaesthetics and levosimendan seem to be promising cardioprotective agents, but large trials are still needed to assess the best cardioprotective agent(s) and optimal protocol(s). The aim of monitoring is early detection and assessment of mechanisms of perioperative cardiovascular dysfunction. Ideally, volume status should be assessed by 'dynamic' measurement of haemodynamic parameters. Assess heart function first by echocardiography, then using a pulmonary artery catheter (especially in right heart dysfunction). If volaemia and heart function are in the normal range, cardiovascular dysfunction is very likely related to vascular dysfunction. In treating myocardial dysfunction, consider the following options, either alone or in combination: low-to-moderate doses of dobutamine and epinephrine, milrinone or levosimendan. In vasoplegia-induced hypotension, use norepinephrine to maintain adequate perfusion pressure. Exclude hypovolaemia in patients under vasopressors, through repeated volume assessments. Optimal perioperative use of inotropes/vasopressors in cardiosurgery remains controversial, and further large multinational studies are needed. Cardiosurgical perioperative classification of cardiac impairment should be based on time of occurrence (precardiotomy, failure to wean, postcardiotomy) and haemodynamic severity of the patient's condition (crash and burn, deteriorating fast, stable but inotrope dependent). In heart dysfunction with suspected coronary hypoperfusion, an intra-aortic balloon pump is highly recommended. A ventricular assist device should be considered before end organ dysfunction becomes evident. Extra-corporeal membrane oxygenation is an elegant solution as a bridge to recovery and/or decision making. This paper offers practical recommendations for management of perioperative HF in cardiosurgery based on European experts' opinion. It also emphasizes the need for large surveys and studies to assess the optimal way to manage perioperative HF in cardiac surgery.
Resumo:
Our experience with the Sapien trans-apical aortic valve (Edwards Lifesciences Inc., Irvine, CA, USA) has been straightforward without per-procedural mortality except in 1/16 consecutive cases who developed non-apical haemorrhage early after valve implantation. We describe the case of an 84-year-old female carrying a very high operative risk (logistic EuroScore of 44%), who underwent a trans-apical stent-valve implantation for severe and symptomatic aortic valve stenosis (23 mm). Due to massive blood loss, an emergency sternotomy and cannulation for cardiopulmonary bypass resuscitation were necessary to treat (without success) an unusual and unexpected subaortic left ventricular free-wall rupture that occurred few minutes after the stent-valve positioning and implantation. To the best of our knowledge, this is the first described case of a left ventricular free-wall rupture occurring after an otherwise non-complicated standard catheter-based aortic valve replacement.
Resumo:
Background: The RCP is a 14 French collapsable percutaneous cardiovascular support device positioned in the descending part of the thoracic aorta via the femoral artery. A 10 patient first in man study demonstrated device safety and significant improvement in renal function among high risk PCI patients. We now report haemodynamic and renal efficacy in patients with ADHF.Methods: Prospective non randomised study seeking to recruit 20 patients with ADHF with a need for inotropic or mechanical circulatory support with: i) EF < 30% ii)Cardiac index(CI) < 2.2 L / min / m2 Outcome measures included: 1) Cardiac index (CI) 2) Pulmonary Capillary Wedge Pressure (PCWP) 3) Urine output / serum creatinine 4) Vascular / device complications 5) 30 day mortalityResults: INTERIM ANALYSIS (n=12) The mean age of the study group was 64 years, with a mean baseline creatinine of 193 umol/L, eGFR 38 ml/min. The intended RCP treatment period was 24 hours. During RCP treatment there was a significant mean reduction of PCWP at 4 hours of 17% (25 to 21 mmHg p=0.04). Mean CI increased at 12 hours by 11%, though not reaching significance (1.78 to 1.96 L/min/m2 p=0.08). RCP insertion prompted substantial diuresis. Urine output tripled over the first 12 hours compared to baseline (55 ml/hr vs 213 ml/hr p=0.03). This was associated with significantly improved renal function, a 28% reduction in serum creatinine at 12 hours (193 to 151 umol/L p=0.003), and a increase in eGFR from 38 ml/min to 50 ml/min (p=0.0007). 2 patients previously refused cardiac transplantation were reassessed and successfully transplanted within 9 months of RCP treatment on the basis of demonstrable renal reversibility. There were no vascular or device complications. There were 2 deaths at 30 days, one from multi-organ failure and sepsis, and one from intractable heart failure - neither were device related.Conclusion: RCP support in ADHF patients was associated with improved haemodynamics, and an improvement in renal function. The Reitan Catheter Pump may have a role in providing percutaneous cardiovascular and renal support in the acutely decompensated cardiac patient, and may have a role in suggesting renal reversibility in potential cardiac transplant patients. Further data will be reported at recruitment completion.
Resumo:
iii. Catheter-related bloodstream infection (CR-BSI) diagnosis usually involves catheter withdrawal. An alternative method for CR-BSI diagnosis is the differential time to positivity (DTP) between peripheral and catheter hub blood cultures. This study aims to validate the DTP method in short-term catheters. The results show a low prevalence of CR-BSI in the sample (8.4%). The DTP method is a valid alternative for CR-BSI diagnosis in those cases with monomicrobial cultures (80% sensitivity, 99% specificity, 92% positive predictive value, and 98% negative predictive value) and a cut-off point of 17.7 hours for positivity of hub blood culture may assess in CR-BSI diagnosis.
Resumo:
Els catéters venosos centrals són necessaris per al maneig del pacient crític però poden ser l´origen d´una bacteriemia. Aquest estudi prospectiu de cohort té com a objectiu determinar la utilitat de l´aplicació d´unes mesures bàsiques de prevenció per disminuir la incidència de bacteriemia associada a catéter. Els resultats de l´estudi confirmen que l´aplicació d´aquest sistema d´intervenció múltiple basat en l´evidencia redueix de forma significativa les bacteriemies associades a catéter a la nostra UCI.
Resumo:
La sospita de bacterièmia relacionada a catèter (BRC) necessita la retirada d’aquest, confirmant-se a posteriori només en un 15-25%. La diferencia en el temps de positivització d´ hemocultius (DTP) ha demostrat ser un mètode fiable per el diagnòstic de BRC evitant la retirada del catèter. Amb la intenció de comprovar la utilitat clínica de la DTP, l’hem comparada amb un mètode diagnòstic estàndard. Hem inclòs 133 pacients ingressats a una unitat de cures intensives portadors de catèters venosos centrals. 56 pacients s’han aleatoritzats. No hem trobat diferències significatives en quant a morbi-mortalitat en els 2 grups havent evitat 70% de retirada innecessària de catèters en el grup de DTP.
Resumo:
Objective: The aim of this study was to investigate the feasibility of transventricular-transseptal approach (TVSA) for extrapleural transcatheter aortic valved stent implantation via a subxyphoidian access. Methods: In five porcine experiments (52.3 +/- 10.9 kg) the right ventricle was exposed via subxyphoidian access. Under the guidance of intracardiac echocardiography (ICE) and fluoroscopy, the transseptal access from right ventricle to left ventricle was created progressively by puncture and dilation with dilators (8F-26F). Valved stents built in-house from commercial tanned pericardium and self-expandable Nitinol stents were loaded into a cartridge. A delivery sheath was then introduced from the right ventricle into the left ventricle and then into the ascending aorta. The cartridge was connected and the valved stent was deployed in the aortic position. Then, the ventricular septal access was sealed with an Amplatzer septal occluder device and the right ventricular access was closed by tying prepared purse-string suture directly. Thirty minutes after the whole procedure, the animals were sacrificed for macroscopic evaluation of the position of valved stent and septal closure device. Result: Procedural success of TVSA was 100% at the first attempt. Mean procedure time was 49 +/- 4 min. Progressive dilatation of the transseptal access resulted in a measurable ventricular septal defect (VSD) after dilator sizes 18F and more. All valved stents were delivered at the target site over the native aortic valve with good acute valve function and no paravalvular leaks. During the procedure, premature beats (5/5) and supraventriclar tachycardias (5/5) were observed, but no atrial-ventricular block (0/5) occurred. Heart rate before (after) was 90 +/- 3 beats min(-1) (100 +/- 2 beats min(-1): p < 0.05), whereas blood pressure was 60 + 1 mm Hg (55 + 2 mm Hg (p < 0.05)). Total blood loss was 280 + 10 ml. The Amplatzer septal occluder devices were fully deployed and the ventricular septal accesses were sealed successfully, without detectable residual shunt. Conclusion: Trans-catheter implantation of aortic valved stent via extrapleural transventricular-transseptal access is technically feasible and has the potential for a simplified procedure under local anaesthesia. (C) 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B. V. All rights reserved.
Resumo:
A method for hemodialysis catheter placement in patients with central thoracic venous stenosis or occlusion is described and initial results are analyzed. Twelve patients, with a mean age of 63.2 years (42-80 years), with central venous stenosis or occlusion, and who required a hemodialysis catheter were reviewed. All lesions were confirmed by helical CT or phlebography. Five patients had stenosis while seven patients were diagnosed with an occlusion of thoracic central veins. All patients were asymptomatic, without sign of superior vena cava syndrome. After percutaneous transstenotic catheterization or guidewire-based recannalization in occlusions, a balloon dilatation was performed and a stent was placed, when necessary, prior to catheter placement. Technical success was 92%. Three patients had angioplasty alone and nine patients had angioplasty with stent placement. Dialysis catheters were successfully inserted through all recannalized accesses. No immediate complication occurred, nor did any patient develop superior vena cava syndrome after the procedure. The mean follow-up was 21.8 months (range, 8-48 months). Three patients developed a catheter dysfunction with fibrin sheath formation (at 7, 11, and 12 months after catheter placement, respectively). Two were successfully managed by percutaneous endovascular approach and one catheter was removed. In conclusion, for patients with central venous stenosis or occlusion and those who need a hemodialysis catheter, catheter insertion can be reliably achieved immediately after endovascular recannalization with acceptable technical and long-term success rates. This technique should be considered as an alternative procedure for placing a new hemodialysis catheter through a patent vein.
Resumo:
The diagnosis of infections involving internal or external neurosurgical drainage devices is challenging, and to our knowledge no single reliable microbiological test exists. We used sonication to study bacterial colonization in 14 explanted external ventricular drains (EVD) and 13 ventriculo-peritoneal shunt (VPS) devices. This technique dislodges biofilm bacteria from the surface of implanted materials before culture. Removed devices were sonicated in saline (40 kHz, 1 minute, 0.25 W/cm(2)), the resulting fluid was cultured aerobically and anaerobically at 37°C, and bacterial growth was counted. Ventricular cerebrospinal fluid (CSF) was cultured separately. In the EVD group, sonication cultures grew significantly more bacteria (64%, 9/14) than cultures of aspirated ventricular CSF (14%, 2/14). In the VPS group the difference was not significant. Positive sonication cultures of EVD catheters yielded a median of >100 colony forming units (CFU) (range, 60-800). For positive sonication cultures of VPS, the median was 1000 CFU (range, 20-100,000). All patients with bacteria in their CSF also had positive sonication cultures from the removed device. Of the five patients with sterile or presumably contaminated CSF cultures but positive sonication cultures of removed shunts, one became afebrile after removal of the EVD, two developed meningitis and two remained asymptomatic. Sonication culture of EVD appears to improve the microbiological assessment of device-related infection and it corroborates with CSF cultures of revision surgery for VPS. Sonication of the removed EVD tip may raise awareness for the onset of meningitis.
Resumo:
A low arousal threshold is believed to predispose to breathing instability during sleep. The present authors hypothesised that trazodone, a nonmyorelaxant sleep-promoting agent, would increase the effort-related arousal threshold in obstructive sleep apnoea (OSA) patients. In total, nine OSA patients, mean+/-sd age 49+/-9 yrs, apnoea/hypopnoea index 52+/-32 events.h(-1), were studied on 2 nights, one with trazodone at 100 mg and one with a placebo, in a double blind randomised fashion. While receiving continuous positive airway pressure (CPAP), repeated arousals were induced: 1) by increasing inspired CO(2) and 2) by stepwise decreases in CPAP level. Respiratory effort was measured with an oesophageal balloon. End-tidal CO(2 )tension (P(ET,CO(2))) was monitored with a nasal catheter. During trazodone nights, compared with placebo nights, the arousals occurred at a higher P(ET,CO(2)) level (mean+/-sd 7.30+/-0.57 versus 6.62+/-0.64 kPa (54.9+/-4.3 versus 49.8+/-4.8 mmHg), respectively). When arousals were triggered by increasing inspired CO(2) level, the maximal oesophageal pressure swing was greater (19.4+/-4.0 versus 13.1+/-4.9 cm H(2)O) and the oesophageal pressure nadir before the arousals was lower (-5.1+/-4.7 versus -0.38+/-4.2 cm H(2)O) with trazodone. When arousals were induced by stepwise CPAP drops, the maximal oesophageal pressure swings before the arousals did not differ. Trazodone at 100 mg increased the effort-related arousal threshold in response to hypercapnia in obstructive sleep apnoea patients and allowed them to tolerate higher CO(2) levels.