984 resultados para B-mode ultrasound
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The effects of body biometrics on cardiac measurements and description of cardiac anatomy were performed in red-tailed boas (Boa constrictor constrictor) (n = 29) using real-time B-mode ultrasonography. Statistical comparison of measured cardiac metrics according to sex and body measurements demonstrated no significant difference between sexes but a highly significant linear increase between body length and mass and all cardiac metrics.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Biotecnologia Animal - FMVZ
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In veterinary medicine, the same clinician usually follows an animal from birth to old age, whereas in human medicine different specialists are required. It is therefore essential that veterinarians know the normal imaging, biochemical, hematological and physical exam values for younglings, which differ significantly from those of adults of the same species. Abdominal radiographies of young animals are poorly defined due to differences in tissue constitution in relation to adults. These same factors, however, substantially improve sonographic images of the region. Nonetheless, the interpretation of B-mode sonographic findings in puppies is difficult due to the lack of information about the normal parameters in this phase of life. The objective of this study was to compile information about peculiarities of abdominal B-mode ultrasonography in puppies and kittens.
Resumo:
BACKGROUND: Ilioinguinal and iliohypogastric nerve blocks may be used in the diagnosis of chronic groin pain or for analgesia for hernia repair. This study describes a new ultrasound-guided approach to these nerves and determines its accuracy using anatomical dissection control. METHODS: After having tested the new method in a pilot cadaver, 10 additional embalmed cadavers were used to perform 37 ultrasound-guided blocks of the ilioinguinal and iliohypogastric nerve. After injection of 0.1 ml of dye the cadavers were dissected to evaluate needle position and colouring of the nerves. RESULTS: Thirty-three of the thirty-seven needle tips were located at the exact target point, in or directly at the ilioinguinal or iliohypogastric nerve. In all these cases the targeted nerve was coloured entirely. In two of the remaining four cases parts of the nerves were coloured. This corresponds to a simulated block success rate of 95%. In contrast to the standard 'blind' techniques of inguinal nerve blocks we visualized and targeted the nerves 5 cm cranial and posterior to the anterior superior iliac spine. The median diameters of the nerves measured by ultrasound were: ilioinguinal 3.0x1.6 mm, and iliohypogastric 2.9x1.6 mm. The median distance of the ilioinguinal nerve to the iliac bone was 6.0 mm and the distance between the two nerves was 10.4 mm. CONCLUSIONS: The anatomical dissections confirmed that our new ultrasound-guided approach to the ilioinguinal and iliohypogastric nerve is accurate. Ultrasound could become an attractive alternative to the 'blind' standard techniques of ilioinguinal and iliohypogastric nerve block in pain medicine and anaesthetic practice.
Resumo:
BACKGROUND: During paravertebral block, the anterolateral limit of the paravertebral space, which consists of the pleura, should preferably not be perforated. Also it is possible that, during the block, the constant superior costotransverse ligament can be missed in the loss-of-resistance technique. We therefore aimed to develop a new technique for an ultrasound-guided puncture of the paravertebral space. METHODS: We performed 20 punctures and catheter placements in 10 human cadavers. A sonographic view showing the pleura and the superior costotransverse ligament was obtained with a slightly oblique scan using a curved array transducer. After inline approach, injection of 10 ml normal saline confirmed the correct position of the needle tip, distended the space, and enabled catheter insertion. The spread of contrast dye injected through the catheters was assessed by CT scans. RESULTS: The superior costotransverse ligament and the paravertebral space were easy to identify. The needle tip reached the paravertebral space without problems under visualization. In contrast, the introduction of the catheter was difficult. The CT scan revealed a correct paravertebral spread of contrast in 11 cases. Out of the remaining, one catheter was found in the pleural space, in six cases there was an epidural, and in two cases there was a prevertebral spread of contrast dye. CONCLUSIONS: We successfully developed a technique for an accurate ultrasound-guided puncture of the paravertebral space. We also showed that when a catheter is introduced through the needle with the tip lying in the paravertebral space, there is a high probability of catheter misplacement into the epidural, mediastinal, or pleural spaces.
Resumo:
OBJECTIVE: (1) To describe the ultrasonographic appearance of multiple congenital ocular anomalies (MCOA) in the eyes of horses with the PMEL17 (Silver) mutant gene. (2) To compare the accuracy of B-mode ocular ultrasound to conventional direct ophthalmoscopy. ANIMALS STUDIED: Sixty-seven Comtois and 18 Rocky Mountain horses were included in the study. PROCEDURES: Horses were classified as being carriers or noncarriers of the PMEL17 mutant allele based on coat color or genetic testing. Direct ophthalmoscopy followed by standardized ultrasonographic examination was performed in all horses. RESULTS: Seventy-five of 85 horses (88.24%) carried at least one copy of the Silver mutant allele. Cornea globosa, severe iridal hypoplasia, uveal cysts, cataracts, and retinal detachment could be appreciated with ultrasound. Carrier horses had statistically significantly increased anterior chamber depth and decreased thickness of anterior uvea compared with noncarriers (P < 0.05). Uveal cysts had a wide range of location and ultrasonographic appearances. In 51/73 (69.86%) carrier horses, ultrasound detected ciliary cysts that were missed with direct ophthalmoscopy. CONCLUSIONS: In this study, ultrasonography was useful to identify uveal cysts in PMEL17 mutant carriers and to assess anterior chamber depth.
Resumo:
An abridgment of Ibn al-Athīr's al-Lubāb, itself an abridgment of al-Samʻāni's Kitāb al-ansāb.
Resumo:
At head of title: ... U.S. Bureau of Public Roads' class B.
Resumo:
Reproduced from typewritten copy.
Resumo:
Includes index.
Resumo:
The inherent analogue nature of medical ultrasound signals in conjunction with the abundant merits provided by digital image acquisition, together with the increasing use of relatively simple front-end circuitries, have created considerable demand for single-bit beamformers in digital ultrasound imaging systems. Furthermore, the increasing need to design lightweight ultrasound systems with low power consumption and low noise, provide ample justification for development and innovation in the use of single-bit beamformers in ultrasound imaging systems. The overall aim of this research program is to investigate, establish, develop and confirm through a combination of theoretical analysis and detailed simulations, that utilize raw phantom data sets, suitable techniques for the design of simple-to-implement hardware efficient digital ultrasound beamformers to address the requirements for 3D scanners with large channel counts, as well as portable and lightweight ultrasound scanners for point-of-care applications and intravascular imaging systems. In addition, the stability boundaries of higher-order High-Pass (HP) and Band-Pass (BP) Σ−Δ modulators for single- and dual- sinusoidal inputs are determined using quasi-linear modeling together with the describing-function method, to more accurately model the modulator quantizer. The theoretical results are shown to be in good agreement with the simulation results for a variety of input amplitudes, bandwidths, and modulator orders. The proposed mathematical models of the quantizer will immensely help speed up the design of higher order HP and BP Σ−Δ modulators to be applicable for digital ultrasound beamformers. Finally, a user friendly design and performance evaluation tool for LP, BP and HP modulators is developed. This toolbox, which uses various design methodologies and covers an assortment of modulators topologies, is intended to accelerate the design process and evaluation of modulators. This design tool is further developed to enable the design, analysis and evaluation of beamformer structures including the noise analyses of the final B-scan images. Thus, this tool will allow researchers and practitioners to design and verify different reconstruction filters and analyze the results directly on the B-scan ultrasound images thereby saving considerable time and effort.