302 resultados para Autogenous
Resumo:
The aim of this study is to evaluate the efficacy of the application of allogenous bone at the maxillo-mandibular reconstructions for future rehabilitation with dental implants. The patients were submitted to reconstruction of maxilla, using allogeneic bone grafts, in 3 different techniques: onlay grafts for lateral ridge augmentation, onlay and particulate bone for sinus lift grafting, and particulate alone for sinus lift grafts. Clinical and radiographic control was done at the postoperative phase for at least 8 months, until the patient could be submitted to the installation of dental implants. The results showed success in the majority of the cases, and dental implants could be installed. This can be considered an excellent alternative when compared with the use of autogenous grafts; because handling is easier, there is a great amount of material available and a possibility of using local anesthesia, and consequently there is a reduction of patient morbidity. (C) 2008 American Association of Oral and Maxillofacial Surgeons
Resumo:
Our goal was to evaluate bone neoformation promoted by a bovine xenograft composite (XC) compared with autogenous graft for maxillary sinus augmentation in a rabbit model. The left maxillary sinus of 18 male rabbits was filled with 200 mg of cortical and cancellous autogenous bone and the right sinus was filled with 200 mg of a composite comprised organic and inorganic bovine matrices, pool of bBMPs and collagen. Postoperative implant intervals of 2, 4, and 8 weeks were analyzed. Differences in the bone optical density among the groups and experimental periods were evaluated by computed tomography analysis. The tissue response was evaluated by histomorphometric analysis of the newly formed bone, connective tissue and/or granulation tissue, residual material, and bone marrow. The tomographic analyses showed a maximum optical density in the 4-week period for both groups. Histologically, an inflammatory infiltrate was observed at 2 weeks in the XC group but exclusively around the organic particles of the biomaterial. Regarding to the amount of newly formed bone, no statistical differences (p > 0.05) were observed among the two treatments throughout the implant intervals. However, by the end of the 8 weeks, the quantity of bone marrow was two times greater (p < 0.05) in the control group than in the XC group. In conclusion, the xenograft composite promotes formation of new bone in a similar fashion to autogenous bone and could therefore be considered a biomaterial with potential applications as a bone substitute in maxillary sinus floor augmentation. (C) 2007 Wiley Periodicals, Inc.
Resumo:
Objectives: This study evaluated key parameters of the in vitro osteogenesis induced by osteoblastic cells obtained from sites submitted to sinus grafting with anorganic bovine bone (ABB) in comparison with cells derived from bone sites of the same patients. Materials and methods: In three patients, the augmentation of maxillary sinus was carried out using ABB (Bio-Oss (R)). After at least 6 months, during the surgical intervention for titanium implants placement, biopsies were taken from these areas using trephine burs (grafted group). Bone fragments, of the same patients, from sites that had not received graft were also obtained with trephine burs and used as a control group. Osteoblastic cells were obtained from grafted and control groups by enzymatic digestion and cultured under standard osteogenic condition until subconfluence. First passaged cells were cultured in 24-well culture plates. Cell adhesion was evaluated at 24 h. For proliferation and viability assay, cells were cultured for 1, 3, 7, and 10 days. Total protein content and alkaline phosphatase (ALP) activity were measured at 3, 7, 10, 14, 17, and 21 days. Cultures were stained with Alizarin red S at 21 days, for detection of mineralized matrix. Data were compared by Student`s t-test. Results: Cell adhesion and viability were not affected by cell source (P>0.05). Total protein content was greater (P<0.05) for grafted group. Cell proliferation, ALP activity, and bone-like nodule formation were all greater (P<0.05) for the control group. Conclusions: Taken together, these results indicate that the in vivo long-term contact of cells with ABB downregulates the expression of osteoblast phenotype and consequently the in vitro osteogenesis.
Seeding Osteoblastic Cells into a Macroporous Biodegradable CaP/PLGA Scaffold by a Centrifugal Force
Resumo:
This study aims to construct a hybrid biomaterial by seeding osteoblastic cells into a CaP/PLGA scaffold by a centrifugal force. Constructs are evaluated with respect to potential application in bone tissue engineering. Cells adher, spread, and form a layer of tissue lining the scaffold and are capable of migrating, proliferating, and producing mineralized matrix. We have demonstrated that the centrifugal force is highly efficient for constructing a hybrid biomaterial, which acts similarly to bone explants in a cell culture environment. In this way, these constructs could mimic an autogenous bone graft in clinical circumstances. Such a strategy may be useful for bone tissue engineering.
Resumo:
Bond's method for ball mill scale-up only gives the mill power draw for a given duty. This method is incompatible with computer modelling and simulation techniques. It might not be applicable for the design of fine grinding ball mills and ball mills preceded by autogenous and semi-autogenous grinding mills. Model-based ball mill scale-up methods have not been validated using a wide range of full-scale circuit data. Their accuracy is therefore questionable. Some of these methods also need expensive pilot testing. A new ball mill scale-up procedure is developed which does not have these limitations. This procedure uses data from two laboratory tests to determine the parameters of a ball mill model. A set of scale-up criteria then scales-up these parameters. The procedure uses the scaled-up parameters to simulate the steady state performance of full-scale mill circuits. At the end of the simulation, the scale-up procedure gives the size distribution, the volumetric flowrate and the mass flowrate of all the streams in the circuit, and the mill power draw.
Model-based procedure for scale-up of wet, overflow ball mills - Part III: Validation and discussion
Resumo:
A new ball mill scale-up procedure is developed. This procedure has been validated using seven sets of Ml-scale ball mil data. The largest ball mills in these data have diameters (inside liners) of 6.58m. The procedure can predict the 80% passing size of the circuit product to within +/-6% of the measured value, with a precision of +/-11% (one standard deviation); the re-circulating load to within +/-33% of the mass-balanced value (this error margin is within the uncertainty associated with the determination of the re-circulating load); and the mill power to within +/-5% of the measured value. This procedure is applicable for the design of ball mills which are preceded by autogenous (AG) mills, semi-autogenous (SAG) mills, crushers and flotation circuits. The new procedure is more precise and more accurate than Bond's method for ball mill scale-up. This procedure contains no efficiency correction which relates to the mill diameter. This suggests that, within the range of mill diameter studied, milling efficiency does not vary with mill diameter. This is in contrast with Bond's equation-Bond claimed that milling efficiency increases with mill diameter. (C) 2001 Elsevier Science Ltd. All rights reserved.
Resumo:
Pulp lifters, also known, as pan lifters are an integral part of the majority of autogenous (AG), semi-autogenous (SAG) and grate discharge ball mills. The performance of the pulp lifters in conjunction with grate design determines the ultimate flow capacity of these mills. Although the function of the pulp lifters is simply to transport the slurry passed through the discharge grate into the discharge trunnion, their performance depends on their design as well as that of the grate and operating conditions such as mill speed and charge level. However, little or no work has been reported on the performance of grate-pulp lifter assemblies and in particular the influence of pulp lifter design on slurry transport. Ideally, the discharge rate through a grate-pulp lifter assembly should be equal to the discharge rate through at a given mill hold-up. However, the results obtained have shown that conventional pulp lifter designs cause considerable restrictions to flow resulting in reduced flow capacity. In this second of a two-part series of papers the performance of conventional pulp lifters (radial and spiral designs) is described and is based on extensive test work carried out in a I m diameter pilot SAG mill. (C) 2003 Elsevier Science Ltd. All rights reserved.
Resumo:
Discharge grates play an important role in determining the performance of autogenous, semi-autogenous and grate discharge ball mills. The flow capacity (grinding capacity) of these mills is strongly influenced by the discharge grate design-open area and position of apertures, as well as the performance of the pulp lifters. As mill sizes have progressively increased and closed-circuiting has become more popular the importance of grate and pulp lifter design has grown. Unfortunately very few studies have concentrated on this aspect of mill performance. To remedy this a series of laboratory and pilot-scale tests were undertaken to study both the performance of grates on their own and in conjunction with pulp lifters. In this first paper of a two-part series the results from the grate-only experiments are presented and discussed, whilst the performance of the grate-pulp-lifter system is covered in the second paper. The results from the grate-only experiments have shown that the build-up of slurry (hold-up) inside the mill starts from the shoulder of the charge, while the toe position of the slurry progressively moves towards the toe of the charge with increasing flowrate. Besides grate design (open area and position of apertures), charge volume and mill speed were also found to have a strong influence on mill hold-up and interact with grate design variables. (C) 2003 Elsevier Science Ltd. All rights reserved.
Resumo:
Although several tendon sources are available for reconstructive surgical procedures, all have one or more shortcomings. The aim of this work was to evaluate if the extensor tendons of the hallux showed anatomical characteristics that could make them an additional source for tendon grafting procedures.The authors performed a detailed morphometric analysis of the extensor tendons of the hallux in 26 lower limbs in order to evaluate the putative association of anatomical variants with hallux valgus, and to attempt to assess the feasibility of using part of the extensor apparatus of the hallux as a source of tendon for grafting procedures.An accessory extensor hallucis longus ten-don was found in 92.3% of cases. The extensor hallucis brevis tendon length was 10.5 ± 0.6 cm; its width was 0.5 ± 0.1 cm, and its thickness varied between 1-2 mm, making it a potentially good candidate as a source of ten-don grafts. Several anatomical variations were observed, namely the fusion of the tendons of the extensor hallucis brevis and the accessory extensor hallucis longus muscles in the distal part of the foot.This new therapeutic option, if implemented, would possibly increase the supply of autogenous donor tissue for reconstructive procedures, thereby enhancing the reconstructive surgeon’s armamentarium.
Coronary bilateral ostial enlargement using the saphenous vein in a patient with syphilitic aortitis
Resumo:
A patient with tertiary syphilis presenting with bilateral coronary ostial lesions and aortic regurgitation underwent surgical reconstruction of the coronary ostia by the anterior approach with autogenous saphenous vein grafting and substitution of the aortic valve with a bovine bioprosthesis. The procedure was easily performed and had good outcomes both early and late. The rarity of the association of a lesion in both coronary ostia with aortic regurgitation in syphilis and the surgical technique employed are discussed.
Resumo:
BACKGROUND: For over 50 years, radiocephalic wrist arteriovenous fistulae (RCAVF) have been the primary and best vascular access for haemodialysis. Nevertheless, early failure due to thrombosis or non-maturation is a major complication resulting in their abandonment. This prospective study was designed to investigate the predictive value of intra-operative blood flow on early failure of primary RCAVF before the first effective dialysis. METHODS: We enrolled patients undergoing creation of primary RCAVF for haemodialysis based on the pre-operative ultrasound vascular mapping discussed in a multidisciplinary approach. Intra-operative blood flow measurement was systematically performed once the anastomosis had been completed using a transit-time ultrasonic flowmeter. During the follow-up, blood flow was estimated by colour flow ultrasound at various intervals. Any events related to the RCAVF were recorded. RESULTS: Autogenous RCAVFs (n = 58) in 58 patients were constructed and followed up for an average of 30 days. Thrombosis and non-maturation occurred in eight (14%) and four (7%) patients, respectively. The intra-operative blood flow in functioning RCAVFs was significantly higher compared to non-functioning RCAVFs (230 vs 98 mL/min; P = 0.007), as well as 1 week (753 vs 228 mL/min; P = 0.0008) and 4 weeks (915 vs 245 mL/min, P < 0.0001) later. Blood flow volume measurements with a cut-off value of 120 mL/min had a sensitivity of 67%, specificity of 75% and positive predictive value of 91%. CONCLUSIONS: Blood flow <120 mL has a good predictive value for early failure in RCAVF. During the procedure, this cut-off value may be used to select appropriately which RCAVF should be investigated in the operation theatre in order to correct in real time any abnormality.
Resumo:
In order to detect seasonal trends in the age structure of adult mosquitoes from Buenos Aires province, Argentina, female populations were sampled with CDC traps during 1989-1991 in Punta Lara and La Plata. The mosquitoes were dissected and age-grouped according to ovarian tracheation and ovariolar stages. All Runchomyia paranensis females were parous, suggesting that this species could be autogenous. Aedes albifasciatus showed parous peaks following population peaks, with shorter delays in spring-summmer and longer in fall-winter. Ae. crinifer and Culex dolosus showed wide fluctuations in age structure due to adult emergences during all months. Psorophora ferox showed high population replacement rates. Mansonia indubitans and Ma. titillans have few generations per year during their activity period. This is the first report on age-grading of adults of field mosquito populations from Argentina
Resumo:
In the present paper we describe the diversity of phlebotomine sandflies collected in three sandstone caves in the municipality of Presidente Figueiredo, state of Amazonas, Brazil. The phlebotomines were captured during 2006 with CDC light traps. Guano samples from inside the Gruta Refúgio do Maruaga were collected to investigate the presence of immature specimens. A total of 2,160 adult phlebotomines representing 15 species were captured. Pintomyia pacae was the dominant species in Gruta dos Animais (1,723 specimens) and Gruta dos Lages (50 specimens) and Deanemyia maruaga new comb (280 specimens) was the dominant species in Gruta Refúgio do Maruaga. A total of 18 guano samples were collected and seven of these samples included immature specimens. A total of 507 immature specimens were captured; 495 of these specimens were larvae and 12 were pupae. The presence of paca (Agouti paca) footprints near Gruta dos Animais and Gruta dos Lages suggests the association of Pi. pacae with this rodent. This finding may explain the abundance of Pi. pacae in these locations, while the species is relatively rare in the forest. Deanemyia maruaga is a cave species that uses guano to breed during its immature stages. Adult specimens of this species are apparently parthenogenetic and autogenous and represent the second record of parthenogenesis for the subfamily Phlebotominae.
Resumo:
Summary: Questionnaire survey concerning the experience of veterinarians about the efficacy and safety of the autogenous inactivated staphylococcal toxoid vaccine used against mastitis in cattle in Finland
Resumo:
High-performance concrete (HPC) overlays have been used increasingly as an effective and economical method for bridge decks in Iowa and other states. However, due to its high cementitious material content, HPC often displays high shrinkage cracking potential. This study investigated the shrinkage behavior and cracking potential of the HPC overlay mixes commonly used in Iowa. In the study, 11 HPC overlay mixes were studied. These mixes consisted of three types of cements (Type I, I/II, and IP) and various supplementary cementitious materials (Class C fly ash, slag and metakaolin). Limestone with two different gradations was used as coarse aggregates in 10 mixes and quartzite was used in one mix. Chemical shrinkage of pastes, free drying shrinkage, autogenous shrinkage of mortar and concrete, and restrained ring shrinkage of concrete were monitored over time. Mechanical properties (such as elastic modulus and compressive and splitting tensile strength) of these concrete mixes were measured at different ages. Creep coefficients of these concrete mixes were estimated using the RILEM B3 and NCHRP Report 496 models. Cracking potential of the concrete mixes was assessed based on both ASTM C 1581 and simple stress-to-strength ratio methods. The results indicate that among the 11 mixes studied, three mixes (4, 5, and 6) cracked at the age of 15, 11, and 17 days, respectively. Autogenous shrinkage of the HPC mixes ranges from 150 to 250 microstrain and free dying shrinkage of the concrete ranges from 700 to 1,200 microstrain at 56 days. Different concrete materials (cementitious type and admixtures) and mix proportions (cementitious material content) affect concrete shrinkage in different ways. Not all mixes having a high shrinkage value cracked first. The stresses in the concrete are associated primarily with the concrete shrinkage, elastic modulus, tensile strength, and creep. However, a good relationship is found between cementitious material content and total (autogenous and free drying) shrinkage of concrete.