927 resultados para Archael_amoA, standard deviation
Empirical vehicle-to-vehicle pathloss modeling in highway, suburban and urban environments at 5.8GHz
Resumo:
In this paper, we present a pathloss characterization for vehicle-to-vehicle (V2V) communications based on empirical data collected from extensive measurement campaign performed under line-of-sight (LOS), non-line-of-sight (NLOS) and varying traffic densities. The experiment was conducted in three different V2V propagation environments: highway, suburban and urban at 5.8GHz. We developed pathloss models for each of the three different V2V environments considered. Based on a log-distance power law model, the values for the pathloss exponent and the standard deviation of shadowing were reported. The average pathloss exponent ranges from 1.77 for highway, 1.68 for the urban to 1.53 for the suburban environment. The reported results can contribute to vehicular network (VANET) simulators and can be used by system designers to develop, evaluate and validate new protocols and system designs under realistic propagation conditions.
Resumo:
Objectives: To develop a new measure of dysfunctional thoughts for family caregivers of people living with dementia. These thoughts can contribute to negative outcomes, but they may be modifiable. Method: A stepwise process was used to develop the Thoughts Questionnaire, commencing with item generation, concept mapping, and pilot testing in a sample of professional and nonprofessional caregivers of people with dementia (n = 18). Next, an independent sample of 35 family caregivers of people with dementia (30 female; M age = 64.30, standard deviation = 10.65) completed: (a) the Thoughts Questionnaire; (b) an existing measure of dysfunctional thoughts, the Dementia Thoughts Caregivers Questionnaire; and (c) separate validated measures of depressive symptoms, caregiver stress, and coping, respectively. Results: The level of agreement with dysfunctional thought statements from the Dementia Thoughts Caregivers Questionnaire and Thoughts Questionnaire was low. However, a small number of Thoughts Questionnaire statements were strongly endorsed by over 85% of the sample. Both dysfunctional thought measures had adequate reliability, but total scores were not significantly intercorrelated (r = .287, p = .095). Only the Thoughts Questionnaire was significantly, positively correlated with most caregiver stress measures. Thoughts Questionnaire items required a much lower reading level than the Dementia Thoughts Caregivers Questionnaire items. Discussion: This study provides preliminary data on a tool for assessing the negative role-related thoughts that family caregivers of people with dementia may experience. Given that these thoughts are implicated in depression but they may be modified, the capacity to identify dysfunctional thoughts may prove useful in caregiver support programs.
Resumo:
The estimation of the critical gap has been an issue since the 1970s, when gap acceptance was introduced to evaluate the capacity of unsignalized intersections. The critical gap is the shortest gap that a driver is assumed to accept. A driver’s critical gap cannot be measured directly and a number of techniques have been developed to estimate the mean critical gaps of a sample of drivers. This paper reviews the ability of the Maximum Likelihood technique and the Probability Equilibrium Method to predict the mean and standard deviation of the critical gap with a simulation of 100 drivers, repeated 100 times for each flow condition. The Maximum Likelihood method gave consistent and unbiased estimates of the mean critical gap. Whereas the probability equilibrium method had a significant bias that was dependent on the flow in the priority stream. Both methods were reasonably consistent, although the Maximum Likelihood Method was slightly better. If drivers are inconsistent, then again the Maximum Likelihood method is superior. A criticism levelled at the Maximum Likelihood method is that a distribution of the critical gap has to be assumed. It was shown that this does not significantly affect its ability to predict the mean and standard deviation of the critical gaps. Finally, the Maximum Likelihood method can predict reasonable estimates with observations for 25 to 30 drivers. A spreadsheet procedure for using the Maximum Likelihood method is provided in this paper. The PEM can be improved if the maximum rejected gap is used.
Resumo:
Purpose Musculoskeletal conditions can impair people’s ability to undertake physical activity as they age. The purpose of this qualitative study was to investigate perceived barriers and facilitators to undertaking physical activity reported by patients accessing ambulatory hospital clinics for musculoskeletal disorders. Patients and methods A questionnaire with open-ended items was administered to patients (n=217, 73.3% of 296 eligible) from three clinics providing ambulatory services for nonsurgical treatment of musculoskeletal disorders. The survey included questions to capture the clinical and demographic characteristics of the sample. It also comprised two open-ended questions requiring qualitative responses. The first asked the participant to describe factors that made physical activity more difficult, and the second asked which factors made it easier for them to be physically active. Participants’ responses to the two open-ended questions were read, coded, and thematically analyzed independently by two researchers, with a third researcher available to arbitrate any unresolved disagreement. Results The mean (standard deviation) age of participants was 53 (15) years; n=113 (52.1%) were male. A total of 112 (51.6%) participants reported having three or more health conditions; n=140 (64.5%) were classified as overweight or obese. Five overarching themes describing perceived barriers for undertaking physical activity were "health conditions", "time restrictions", "poor physical condition", "emotional, social, and psychological barriers", and "access to exercise opportunities". Perceived physical activity facilitators were also aligned under five themes, namely "improved health state", "social, emotional, and behavioral supports", "access to exercise environment", "opportunities for physical activities", and "time availability". Conclusion It was clear from the breadth of the data that meaningful supports and interventions must be multidimensional. They should have the capacity to address a variety of physical, functional, social, psychological, motivational, environmental, lifestyle, and other perceived barriers. It would appear that for such interventions to be effective, they should be flexible enough to address a variety of specific concerns.
Resumo:
Objectives Shift workers are prone to obesity and associated co-morbidities such as diabetes and cardiovascular disease. Sleep restriction associated with shift work results in dramatic endocrine and metabolic effects that predispose shift workers to these adverse health consequences. While sleep restriction has been associated with increased caloric intake, food preference may also play a key role in weight gain associated with shift work. This study examined the impact of an overnight simulated night shift on food preference. Methods Sixteen participants [mean 20.1, standard deviation (SD) 1.4 years; 8 women] underwent a simulated night shift and control condition in a counterbalanced order. On the following morning, participants were provided an opportunity for breakfast that included high- and low-fat food options (mean 64.8% and 6.4% fat, respectively). Results Participants ate significantly more high-fat breakfast items after the simulated night shift than after the control condition [167.3, standard error of the mean (SEM 28.7) g versus 211.4 (SEM 35.6) g; P=0.012]. The preference for high-fat food was apparent among the majority of individuals following the simulated night shift (81%), but not for the control condition (31%). Shift work and control conditions did not differ, however, in the total amount of food or calories consumed. Conclusions A simulated night shift leads to preference for high-fat food during a subsequent breakfast opportunity. These results suggest that food choice may contribute to weight-related chronic health problems commonly seen among night shift workers.
Resumo:
This paper presents an efficient noniterative method for distribution state estimation using conditional multivariate complex Gaussian distribution (CMCGD). In the proposed method, the mean and standard deviation (SD) of the state variables is obtained in one step considering load uncertainties, measurement errors, and load correlations. In this method, first the bus voltages, branch currents, and injection currents are represented by MCGD using direct load flow and a linear transformation. Then, the mean and SD of bus voltages, or other states, are calculated using CMCGD and estimation of variance method. The mean and SD of pseudo measurements, as well as spatial correlations between pseudo measurements, are modeled based on the historical data for different levels of load duration curve. The proposed method can handle load uncertainties without using time-consuming approaches such as Monte Carlo. Simulation results of two case studies, six-bus, and a realistic 747-bus distribution network show the effectiveness of the proposed method in terms of speed, accuracy, and quality against the conventional approach.
Resumo:
PURPOSE To review records of 330 patients who underwent surgery for femoral neck fractures with or without preoperative anticoagulation therapy. METHODS Medical records of 235 women and 95 men aged 48 to 103 years (mean, 81.6; standard deviation [SD], 13.1) who underwent surgery for femoral neck fractures with or without preoperative anticoagulation therapy were reviewed. 30 patients were on warfarin, 105 on aspirin, 28 on clopidogrel, and 167 were controls. The latter 3 groups were combined as the non-warfarin group and compared with the warfarin group. Hospital mortality, time from admission to surgery, length of hospital stay, return to theatre, and postoperative complications (wound infection, deep vein thrombosis, and pulmonary embolism) were assessed. RESULTS The warfarin and control groups were significantly younger than the clopidogrel and aspirin groups (80.8 vs. 80.0 vs. 84.2 vs. 83.7 years, respectively, p<0.05). 81% of the patients underwent surgery within 48 hours of admission. The overall mean time from admission to surgery was 1.8 days; it was longer in the warfarin than the aspirin, clopidogrel, and control groups (3.3 vs. 1.8 vs. 1.6 vs. 1.6 days, respectively, p<0.001). The mean length of hospital stay was 17.5 (SD, 9.6; range, 3-54) days. The overall hospital mortality was 3.9%; it was 6.7% in the warfarin group, 3.8% in the aspirin group, 3.6% in the clopidogrel group, and 3.6% in the control group (p=0.80). Four patients returned to theatre for surgery: one in the warfarin group for washout of a haematoma, 2 in the aspirin group for repositioning of a mal-fixation and for debridement of wound infection, and one in the control group for debridement of wound infection. The warfarin group did not differ significantly from non-warfarin group in terms of postoperative complication rate (6.7% vs. 2.7%, p=0.228) and the rate of return to theatre (3.3% vs. 1%, p=0.318). CONCLUSION It is safe to continue aspirin and clopidogrel prior to surgical treatment for femoral neck fracture. The risk of delaying surgery outweighs the peri-operative bleeding risk.
Resumo:
A facile and sensitive surface-enhanced Raman scattering substrate was prepared by controlled potentiostatic deposition of a closely packed single layer of gold nanostructures (AuNS) over a flat gold (pAu) platform. The nanometer scale inter-particle distance between the particles resulted in high population of ‘hot spots’ which enormously enhanced the scattered Raman photons. A renewed methodology was followed to precisely quantify the SERS substrate enhancement factor (SSEF) and it was estimated to be (2.2 ± 0.17) × 105. The reproducibility of the SERS signal acquired by the developed substrate was tested by establishing the relative standard deviation (RSD) of 150 repeated measurements from various locations on the substrate surface. A low RSD of 4.37 confirmed the homogeneity of the developed substrate. The sensitivity of pAu/AuNS was proven by determining 100 fM 2,4,6-trinitrotoluene (TNT) comfortably. As a proof of concept on the potential of the new pAu/AuNS substrate in field analysis, TNT in soil and water matrices was selectively detected after forming a Meisenheimer complex with cysteamine.
Resumo:
Objective To identify the prevalence of and risk factors for inadvertent hypothermia after procedures performed with procedural sedation and analgesia in a cardiac catheterisation laboratory. Design Single-centre, prospective observational study. Setting Tertiary care private hospital in Australia. Participants A convenience sample of 399 patients undergoing elective procedures with procedural sedation and analgesia were included. Propofol infusions were used when an anaesthetist was present. Otherwise, bolus doses of either midazolam or fentanyl or a combination of these medications was used. Interventions None Measurements and main results Hypothermia was defined as a temperature <36.0° Celsius. Multivariate logistic regression was used to identify risk factors. Hypothermia was present after 23.3% (n=93; 95% confidence interval [CI] 19.2%-27.4%) of 399 procedures. Sedative regimens with the highest prevalence of hypothermia were any regimen that included propofol (n=35; 40.2%; 95% CI 29.9%-50.5%) and the use of fentanyl combined with midazolam (n=23; 20.3%; 95% CI 12.9%-27.7%). Difference in mean temperature from pre to post-procedure was -0.27°C (Standard deviation [SD] 0.45). Receiving propofol (odds ratio [OR] OR 4.6 95% CI 2.5-8.6), percutaneous coronary intervention (OR 3.2 95% CI 1.7-5.9), body mass index <25 (OR 2.5 95% CI 1.4-4.4) and being hypothermic prior to the procedure (OR 4.9; 95% CI 2.3-10.8) were independent predictors of post-procedural hypothermia. Conclusions A moderate prevalence of hypothermia was observed. The small absolute change in temperature observed may not be a clinically important amount. More research is needed to increase confidence in our estimates of hypothermia in sedated patients and its impact on clinical outcomes.
Resumo:
The aim of this study was to develop a new method for quantifying intersegmental motion of the spine in an instrumented motion segment L4–L5 model using ultrasound image post-processing combined with an electromagnetic device. A prospective test–retest design was employed, combined with an evaluation of stability and within- and between-day intra-tester reliability during forward bending by 15 healthy male patients. The accuracy of the measurement system using the model was calculated to be ± 0.9° (standard deviation = 0.43) over a 40° range and ± 0.4 cm (standard deviation = 0.28) over 1.5 cm. The mean composite range of forward bending was 15.5 ± 2.04° during a single trial (standard error of the mean = 0.54, coefficient of variation = 4.18). Reliability (intra-class correlation coefficient = 2.1) was found to be excellent for both within-day measures (0.995–0.999) and between-day measures (0.996–0.999). Further work is necessary to explore the use of this approach in the evaluation of biomechanics, clinical assessments and interventions.
Resumo:
This study aimed to take existing anatomical models of pregnant women, currently used for radiation pro-tection and nuclear medicine dose calculations, and adapt them for use in the calculation of fetal dose from external beam radiotherapy (EBRT). The models investigated were ‘KATJA’, which was provided as an MCNPX geometry file, and ‘RPI-P6’, which was provided in a simple, voxelized bina-ry format. In-house code was developed, to convert both mod-els into an `egsphant’ format, suitable for use with DOSXYZnrc. The geometries and densities of the resulting phantoms were evaluated and found to accurately represent the source data. As an example of the use of the phantoms, the delivery of a cranial EBRT treatment was simulated using the BEAMnrc and DOSXYZnrc Monte Carlo codes and the likely out-of-field doses to the fetus in each model was calculated. The results of these calculations showed good agreement (with-in one standard deviation) between the doses calculated in KATJA and PRI-P6, despite substantial anatomical differ-ences between the two models. For a 36 Gy prescription dose to a 233.2 cm3 target in the right brain, the mean doses calcu-lated in a region of interest covering the entire uterus were 1.0 +/- 0.6 mSv for KATJA and 1.3 +/- 0.9 mSv for RPI-P6. This work is expected to lead to more comprehensive studies of EBRT treatment plan design and its effects on fetal dose in the future.
Resumo:
The size and arrangement of stromal collagen fibrils (CFs) influence the optical properties of the cornea and hence its function. The spatial arrangement of the collagen is still questionable in relation to the diameter of collagen fibril. In the present study, we introduce a new parameter, edge-fibrillar distance (EFD) to measure how two collagen fibrils are spaced with respect to their closest edges and their spatial distribution through normalized standard deviation of EFD (NSDEFD) accessed through the application of two commercially available multipurpose solutions (MPS): ReNu and Hippia. The corneal buttons were soaked separately in ReNu and Hippia MPS for five hours, fixed overnight in 2.5% glutaraldehyde containing cuprolinic blue and processed for transmission electron microscopy. The electron micrographs were processed using ImageJ user-coded plugin. Statistical analysis was performed to compare the image processed equivalent diameter (ED), inter-fibrillar distance (IFD), and EFD of the CFs of treated versus normal corneas. The ReNu-soaked cornea resulted in partly degenerated epithelium with loose hemidesmosomes and Bowman’s collagen. In contrast, the epithelium of the cornea soaked in Hippia was degenerated or lost but showed closely packed Bowman’s collagen. Soaking the corneas in both MPS caused a statistically significant decrease in the anterior collagen fibril, ED and a significant change in IFD, and EFD than those of the untreated corneas (p < 0.05, for all comparisons). The introduction of EFD measurement in the study directly provided a sense of gap between periphery of the collagen bundles, their spatial distribution; and in combination with ED, they showed how the corneal collagen bundles are spaced in relation to their diameters. The spatial distribution parameter NSDEFD indicated that ReNu treated cornea fibrils were uniformly distributed spatially, followed by normal and Hippia. The EFD measurement with relatively lower standard deviation and NSDEFD, a characteristic of uniform CFs distribution, can be an additional parameter used in evaluating collagen organization and accessing the effects of various treatments on corneal health and transparency.
Resumo:
This study implemented linear and nonlinear methods of measuring variability to determine differences in stability of two groups of skilled (n = 10) and unskilled (n = 10) participants performing 3m forward/backward shuttle agility drill. We also determined whether stability measures differed between the forward and backward segments of the drill. Finally, we sought to investigate whether local dynamic stability, measured using largest finite-time Lyapunov exponents, changed from distal to proximal lower extremity segments. Three-dimensional coordinates of five lower extremity markers data were recorded. Results revealed that the Lyapunov exponents were lower (P < 0.05) for skilled participants at all joint markers indicative of higher levels of local dynamic stability. Additionally, stability of motion did not differ between forward and backward segments of the drill (P > 0.05), signifying that almost the same control strategy was used in forward and backward directions by all participants, regardless of skill level. Furthermore, local dynamic stability increased from distal to proximal joints (P < 0.05) indicating that stability of proximal segments are prioritized by the neuromuscular control system. Finally, skilled participants displayed greater foot placement standard deviation values (P < 0.05), indicative of adaptation to task constraints. The results of this study provide new methods for sport scientists, coaches to characterize stability in agility drill performance.
Resumo:
It is difficult to determine sulfur-containing volatile organic compounds in the atmosphere because of their reactivity. Primary off-line techniques may suffer losses of analytes during the transportation from field to laboratory and sample preparation. In this study, a novel method was developed to directly measure dimethyl sulfide at parts-per-billion concentration levels in the atmosphere using vacuum ultraviolet single photon ionization time-of-flight mass spectrometry. This technique offers continuous sampling at a response rate of one measurement per second, or cumulative measurements over longer time periods. Laboratory prepared samples of different concentrations of dimethyl sulfide in pure nitrogen gas were analyzed at several sampling frequencies. Good precision was achieved using sampling periods of at least 60 seconds with a relative standard deviation of less than 25%. The detection limit for dimethyl sulfide was below the 3 ppb olfactory threshold. These results demonstrate that single photon ionization time-of-flight mass spectrometry is a valuable tool for rapid, real-time measurements of sulfur-containing organic compounds in the air.
Resumo:
Introduction The Skin Self-Examination Attitude Scale (SSEAS) is a brief measure that allows for the assessment of attitudes in relation to skin self-examination. This study evaluated the psychometric properties of the SSEAS using Item Response Theory (IRT) methods in a large sample of men ≥ 50 years in Queensland, Australia. Methods A sample of 831 men (420 intervention and 411 control) completed a telephone assessment at the 13-month follow-up of a randomized-controlled trial of a video-based intervention to improve skin self-examination (SSE) behaviour. Descriptive statistics (mean, standard deviation, item–total correlations, and Cronbach’s alpha) were compiled and difficulty parameters were computed with Winsteps using the polytomous Rasch Rating Scale Model (RRSM). An item person (Wright) map of the SSEAS was examined for content coverage and item targeting. Results The SSEAS have good psychometric properties including good internal consistency (Cronbach’s alpha = 0.80), fit with the model and no evidence for differential item functioning (DIF) due to experimental trial grouping was detected. Conclusions The present study confirms the SSEA scale as a brief, useful and reliable tool for assessing attitudes towards skin self-examination in a population of men 50 years or older in Queensland, Australia. The 8-item scale shows unidimensionality, allowing levels of SSE attitude, and the item difficulties, to be ranked on a single continuous scale. In terms of clinical practice, it is very important to assess skin cancer self-examination attitude to identify people who may need a more extensive intervention to allow early detection of skin cancer.