996 resultados para Aparelho lacrimal
Resumo:
PURPOSE: Describe hearing aid use by the elderly population in the city of São Paulo and identify associated factors. METHODS: A cross-sectional, descriptive, quantitative study integrated with the SABE (health, well-being and aging) project developed in 2006. A total of 1.115 individuals aged 65 or over were interviewed. Sample selection occurred in two stages, with replacement and probabilities proportional to the population to complement those aged 75 or over. Structured questionnaires and validated instruments were used. The data were weighted, the Rao-Scott test was used for univariate analysis and backward stepwise logistic regression was used for multivariate analysis, performed on Stata 10® software. RESULTS: Three hundred and seventy-seven subjects (30.4%) were classified as hearing impaired and 10.1% of these reported using hearing aids. To acquire the devices, 78.8% used their own resources and 16.9% acquired them through the Brazilian public health system (SUS). Among non-users of hearing aids, 16.6% reported prior indication; however, 8.6% were unable to adapt to the device and 8.0% could not afford to acquire one. Hearing aid use was associated with lower prevalence of probable dementia. CONCLUSION: The low number of hearing aid users indicates the difficulties elderly people face in acquiring them and/or that the health services face in effectively helping them to adapt. These findings may influence the quality of life of elderly with hearing impairment, given the association with probable dementia revealed by this study.
Resumo:
Pós-graduação em Agronomia (Entomologia Agrícola) - FCAV
Resumo:
Pós-graduação em Ciências Odontológicas - FOAR
Resumo:
Pós-graduação em Ciências Odontológicas - FOAR
Resumo:
This study compared the effect of the treatment protocol for correcting Class Il malocclusion using the Herbst appliance followed by full fixed Straigh-wire mechanics, in two populations, one Brazilian and one of North American origin As a untreated control sample the data from the University of Michigan Elementary and Secondary School Growth Study (UMGS) was used. Our sample was composed of 12 males and 12 females, with initial mean age of 12 years 7 months and final mean ages of 15 years and 3 months. The Michigan patients comprised 21 females and 7 males, with an initial mean age of 11 years and 9 months and final mean age of 14 years and 4 months. The control sample was paired in number, sex and age to the treated Michigan sample. ln both treated groups, lateral cephalometric radiographs were obtained before the Herbst appliance was cemented and at the end of the fixed appliance phase, The first comparison involved the Brazil group and the untreated controls, which demonstrated that the association of the Herbst appliance followed by fixed Straight-wire appliances provoked positive effects on the dentofacial complex, improving pre-existing maxillo-mandibular relationships, besides increasing dentoalveolar compensations which contributed to correct the malocclusion. The second comparison, involved the Brazl1ian and North-American patients treated with the same protocol. Although the pre-treatment comparison showed that the two groups were not similar in all aspects, they presented almost identical therapeutic modifications, which indicate that the effect of' treatment was very similar. These results point out that, in Class ll treatment, the combination of Herbst/Straight-wire mechanics produce consistent and systematic effects, correcting or minimizing possible skeletal imbalances
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The study and selection of an equipment of air conditioner for any type of environment, should be made without overestimate or undersizing the project. The undersizing does not provide an adequate comfort temperature if the environment is too hot because the air conditioner does not remove all the heat necessary in the environment. But if the project is oversized, energy consumption is higher and there is an unnecessary cost. To prevent these failures is necessary to make a calculation of the thermal load on the environment and choose the equipment that has a higher cooling capacity than the calculated heat load and closer to the calculated heat load. In this graduate work will be chosen an air-conditioned equipment for bus, showing the calculations made for the thermal load for various types of heat gain in this type of vehicle. The thermal load on vehicles is more complicated to calculate than in areas because there are several factors that vary with the movement of the vehicle. It will also explain the compression refrigeration cycle, which is the cooling system used in vehicles because it is weightless, compact and lower cost. From the calculated heat load, it will be chosen an air conditioner that best suits the project and, finally, a brief presentation of the selected equipment will be made
Resumo:
Along with the advance of technology, in terms of the expansion of medical exams that uses the ionizing radiation for diagnosis, there is also the concern about quality control for maintaining quality in radiographic imaging and for delivering low dose to the patient. Based on the Federal Order 453 of the Secretariat of Health Surveillance, which takes account of the practical and justification of individual medical exposures, the optimization of radiological protection, limitation of individual dose, and the prevention of accidents, were done through this paper radiodiagnostic tests on medical equipment in order to accept it or not, according to SVS-453. Along with the help and support of P&R Consulting and Medical Physics Marilia, SP, were made Quality Control and Radiometric Control in equipment from various cities across the state of São Paulo. The equipment discussed in this work is classified as conventional X-ray. According to the Federal Order SVS-453, the quality control in the program of quality assurance should include the following minimum set of constancy tests, with following minimum frequency: biennial tests for representative values of dose given to the patients of radiography and CT performed in the service; annual tests for accuracy of the indicator tube voltage (kVp), accuracy of exposure time, half-value layer, aligning the central axis of the beam of x-ray tube, performance (mGy / mA.min.m²), linearity of the rate of kerma on air with the mAs, reproducibility of the kerma on air rates, reproducibility of the automatic exposure, focal spot size, integrity of accessories and clothing for individual protection; semiannually for collimation system accuracy; weekly for temperature processing system and sensitometry processing system. For the room Radiometric Survey it was done a sketch...(Complete abstract click electronic access below)
Resumo:
Objectives: natural dentofacial changes and that induced by the Thurow modified extra oral appliance (TMEOA) were evaluated in this prospective study. Methodology: the data consisted of fifteen Class II division 1 children 7 to 10 years old, with anterior open bite and hiperdivergent facial pattern treated with the Thurow appliance and of fifteen Class II division 1 children followed longitudinally from 6 to 12 years of age without treatment (Burlington Growth Centre, Toronto University, Canada). The analyses were based in traditional measurements obtained in lateral cephalometric radiographs scanned with the aid of the software Radiocef Studio®. Radiographs were taken in the beginning and after 1 year of treatment for the treated group and at the 6, 9 and 12 years of age for the control group. Results: the data analysis showed that the TMEOA significantly reduced the SNA, ANB, AOBO, SNPOc SNPM, SGO/NMe, OJ e OB. On the other hand the appliance did not interfere with the SNB e SNPP. The natural growth promoted significant change in the ANB, AOBO, SNPOc, OJ e OB from 6 to 9 years and in the SNB, SNPOc e SGo/NMe from 9 to 12 years. The restriction of the maxillary growth (SNA), reduction of the skeletal discrepancy (ANB) and the reduction of the overjet (OJ) were significant with the treatment considering the natural growth as verified in the control group. Conclusion: the TMEOA corrected the skeletal Class II malocclusion by maxillary restriction, reducing the overjet, closing the anterior open bite and decreasing both the hyper divergent facial pattern and mandible plane inclination.
Resumo:
When well indicated, the orthodontic surgical approach is the ideal treatment mean for Skeletal Class III adult patients. To improve facial esthetic results from orthognatic surgery, the leveling and alignment of maxillary dental arch must be achieved with minimal inclination and projection or even retro-inclination of anterior upper teeth. During a pre-surgical phase of 12 months, headgear bilateral force of 150 g/F was applied to the upper molars of a 22 years old male compliant patient with Class III skeletal malocclusion, to provide an upper teeth control of mesial tipping and projection during alignment and leveling. The ideal occlusal parameters required for surgical procedure were achieved without dental extractions permitting a total treatment period of 37 months. The outcomes remained stable over 3 years follow up after the removal of the appliance. The results indicate that, although headgear use depends greatly on patient compliance, when well indicated it is an interesting alternativetopromote dentaldecompensationon pre-surgical period, in order to allow surgical correction of skeletal Class III malocclusion.
Resumo:
Two treatment options are available for adult patients with skeletal Class II malocclusion caused by mandibular deficiency: combined mandibular advancement surgery and orthodontic treatment or mandibular advancement appliance. This study aimed to analyze the effects of two therapeutic modalities of Class II malocclusion treatment with mandibular deficiency. Two distinct individuals with Class II malocclusion division 1 and mandibular deficiency were treated after growth spurt. The first individual used the Herbst appliance as a therapeutic option and the second individual was treated with bilateral sagittal osteotomy. The cephalometric, occlusion and face results were evaluated for both individuals. Correction of Class II malocclusion was observed on both Herbst and surgery patients resulting on a normal occlusal relationship with normal overjet and overbite. Therefore it was concluded that Herbst appliance can be used to treat borderline skeletal Class II in adult patients.
Resumo:
The study aimed to assess the degree of dental crowding correction on the lower anterior region of patients treated with T4k functional appliance using Little’s irregularity index. Twenty caucasian patients of both gender (10 female and 10 male) were selected. They featured malocclusion Class I and II in mixed dentition, with chronological age between 5.7 and 11 years. The treatment lasted from 1 year and 11 months up to 3 years and 11 months. Lower anterior crowding was measured using Little’s irregularity index. Measurements were obtained on study models achieved before and after functional orthopedic therapy, using a digital caliper in millimeters and placed parallel to the occlusal plane. Overjet and overbite measurements were also performed using a caliper. Results demonstrated that the therapy provided significant decrease in overjet (average = 1.55 mm) and also in the irregularity index (average = 1.23 mm). There was a nonsignificant raise in overbite. There was no relation between the studied variables and the treatment period or even with the patient’s age in the beginning of the therapy. The treatment with T4k resulted on reduction and improvement of dental crowding.
Resumo:
Due to its high prevalence in general population, Angle Class II malocclusion has been widely studied by several authors, as well as the methods for its treatment. Among the possible treatment methods stands out the Herbst appliance. Reintroduced more than three decades ago in the orthodontics community, it became the most utilized appliance because it does not require patient compliance, and provides continued action through bilateral telescopic tubes. The objective of the present article was to demonstrate the early treatment of Class II Division 1 malocclusion with mandibular retrusion using Herbst appliance.
Resumo:
The current reports the case of a young patient with malocclusion Class II division 1 on permanent dentition treated in two stages, rthopedics and orthodontics, respectively. At first, the banded Herbst appliance was used duringa 7 months period, followed by a T4K appliance, Trainer for Kids used as retention, and on the second stage the corrective Orthodontics was performed. The results showed the acquirement of a Class I dental relationship, which was kept stable, with excellent intercuspation, even after 5 years of the removal of the Herbst appliance, as well as the correction of the overjet and the reduction of the facial profile convexity. It can be concluded that the Herbst appliance was very efficient in correcting the Class II malocclusion, long term, also providing a very favorable effect on the facial profile.
Resumo:
The aim of this retrospective study was to evaluate mandibular and maxillary changes induced by the use of Herbst applianceand by natural growth through oblique cephalometric radiographs in children with Class II division 1 malocclusion with mandibular retrusion. A sample of 49 individuals with age ranging from 8 to 10 years old (before growth peak) with Class II division 1, were into two groups: Herbst treated group (n=24) and control group (n=25). Both groups were paired for gender and chronological age. Statistical analysis was performed through Student’s t test. The Herbst appliance promoted the Class II correction in a 7 months period by mesialization of lower permanent first molars and distalization of upper permanent first molars. The Herbst appliance had no influence over the mandibular structure or the mandibular length. It was concluded that early treatment with Herbst appliance corrected the Class II malocclusion by means of dentoalveolar changes.