984 resultados para Anesthesia, inhalation
Resumo:
University of Iowa Department of Anesthesia newsletter.
Resumo:
University of Iowa Department of Anesthesia newsletter.
Resumo:
University of Iowa Department of Anesthesia newsletter.
Resumo:
University of Iowa Department of Anesthesia newsletter.
Resumo:
University of Iowa Department of Anesthesia newsletter.
Resumo:
University of Iowa Department of Anesthesia newsletter.
Resumo:
University of Iowa Department of Anesthesia newsletter.
Resumo:
Loss-of-function mutations in the gene SCN5A can cause Brugada syndrome (BrS), which is an inherited form of idiopathic ventricular fibrillation. We report the case of a 46-year-old patient, with no previous medical history, who had ventricular fibrillation after accidental inhalation of gasoline vapors. His electrocardiogram (ECG) showed a typical type-1 BrS pattern that persisted after the acute event. Genetic investigations allowed the identification of a novel SCN5A mutation leading to a frame-shift and early termination of the channel protein. Biochemical and cellular electrophysiology experiments confirmed the loss-of-function of the mutant allele. The patient was implanted with a cardioverter/defibrillator.
Resumo:
INTRODUCTION: Inhalation injury is an important determinant of outcome in patients with major burns. However the diagnostic criteria remain imprecise, preventing objective comparisons of published data. The aims were to evaluate the utility of an inhalation score based on mucosal injury, while assessing separately the oro-pharyngeal sphere (ENT) and tracheobronchial tree (TB) in patients admitted to the ICU with a suspicion of inhalation injury. METHODS: Prospective observational study in 100 patients admitted with suspicion of inhalation injury among 168 consecutive burn admissions to the ICU of a university hospital. Inclusion criteria, endoscopic airway assessment during the first hours. ENT/TB lesion grading was 1: oedema, hyperemia, hypersecretion, 2: bullous mucosal detachment, erosion, exudates, 3: profound ulcers, necrosis. RESULTS: Of the 100 patients (age 42±17 years, burns 23±19%BSA), 79 presented an ENT inhalation injury ≥ENT1 (soot present in 24%): 36 had a tracheobronchial extension, 33 having a grade ≥TB1. Burned vibrissae: 10 patients "without" suffered ENT injury, while 6 patients "with" had no further lesions. Length of mechanical ventilation was strongly associated with the first 24 hrs' fluid resuscitation volume (p<0.0001) and the presence of inhalation injury (p=0.03), while the ICU length of stay was correlated with the %BSA. Soot was associated with prolonged mechanical ventilation (p=0.0115). There was no extubation failure. CONCLUSIONS: The developed inhalation score was simple to use, providing a unified language, and drawing attention to upper airway involvement. Burned vibrissae and suspected history proved to be insufficient diagnostic criteria. Further studies are required to validate the score in a larger population.
Resumo:
BACKGROUND: An auditory perceptual learning paradigm was used to investigate whether implicit memories are formed during general anesthesia. METHODS: Eighty-seven patients who had an American Society of Anesthesiologists physical status of I-III and were scheduled to undergo an elective surgery with general anesthesia were randomly assigned to one of two groups. One group received auditory stimulation during surgery, whereas the other did not. The auditory stimulation consisted of pure tones presented via headphones. The Bispectral Index level was maintained between 40 and 50 during surgery. To assess learning, patients performed an auditory frequency discrimination task after surgery, and comparisons were made between the groups. General anesthesia was induced with thiopental and maintained with a mixture of fentanyl and sevoflurane. RESULTS: There was no difference in the amount of learning between the two groups (mean +/- SD improvement: stimulated patients 9.2 +/- 11.3 Hz, controls 9.4 +/- 14.1 Hz). There was also no difference in initial thresholds (mean +/- SD initial thresholds: stimulated patients 31.1 +/- 33.4 Hz, controls 28.4 +/- 34.2 Hz). These results suggest that perceptual learning was not induced during anesthesia. No correlation between the bispectral index and the initial level of performance was found (Pearson r = -0.09, P = 0.59). CONCLUSION: Perceptual learning was not induced by repetitive auditory stimulation during anesthesia. This result may indicate that perceptual learning requires top-down processing, which is suppressed by the anesthetic.
Resumo:
Background and objective: Asthma is one of the most frequent chronic diseases affecting children and adolescents. Good compliance is indispensable for effective treatment since a suboptimal use of inhalation devices can result in decreased therapeutic efficacy and increased morbidity. The objective of this work was to evaluate the inhalation technique of paediatric patients visiting a specialized consultation clinic of a university hospital. Design: Observational prospective study during a 3-month period. Setting Specialized consultation clinic of a university hospital. Main outcome measures: This study involved 40 outpatient infants, children and adolescents visiting alone or with their parent(s). Patients' data (age, sex, weight, diagnostic, reason for consulting, previous consultations) and their medicines were compiled using an ad hoc form. Filmed sequences of the inhalation procedure used by each child were reviewed independently by members of an interdisciplinary team consisting in a physician, a pharmacist, a nurse and a physiotherapist. A score of 1 was assigned to each correct step in the procedure, and a score of 0 to an incorrect step. A perfect procedure implied 12 correct steps. Results: Thirty patients were treated with a metered-dose inhaler and an inhalation chamber (Babyhaler or AeroChamber Plus); ten other patients were treated with a dry powder inhaler (Diskus or Turbuhaler). The agreement between the members of the interdisciplinary team was considered satisfactory. Nine patients (22.5%) reached an average score lower than 7, 18 patients (45%) a score between 7 and 10 and 13 (32.5%) a score equal to or better than 10. No patient reached the maximum score of 12. Users of the metered-dose inhalers (average score = 9.2) showed a better technique than users of the dry powder inhalers (average score = 7.4). Disappointingly, the score was not improved during a second consultation or following regular consultations. Conclusions: Video recording is a simple method to evaluate the degree of mastery of an inhalation procedure in paediatric patients. The method allows a convenient and efficient identification of suboptimal procedure steps by the hospital staff, and opens the way to patient-specific teaching. In two-thirds of juvenile patients, their inhalation technique was suboptimal despite initial training. This study shows conclusively that the inhalation technique in paediatric patients must be monitored during each examination, and teaching measures taken to improve it when necessary.
Resumo:
In the past decade, many studies have been conducted to determine the health effects induced by exposure to engineered nanomaterials (NMs). Specifically for exposure via inhalation, numerous in vitro and animal in vivo inhalation toxicity studies on several types of NMs have been published. However, these results are not easily extrapolated to judge the effects of inhaling NMs in humans, and few published studies on the human response to inhalation of NMs exist. Given the emergence of more industries utilizing iron oxide nanoparticles as well as more nanomedicine applications of superparamagnetic iron oxide nanoparticles (SPIONs), this review presents an overview of the inhalation studies that have been conducted in humans on iron oxides. Both occupational exposure studies on complex iron oxide dusts and fumes, as well as human clinical studies on aerosolized, micron-size iron oxide particles are discussed. Iron oxide particles have not been described to elicit acute inhalation response nor promote lung disease after chronic exposure. The few human clinical studies comparing inhalation of fine and ultrafine metal oxide particles report no acute changes in the health parameters measured. Taken together existing evidence suggests that controlled human exposure to iron oxide nanoparticles, such as SPIONs, could be conducted safely.
Resumo:
Waterproofing agents are widely used to protect leather and textiles in both domestic and occupational activities. An outbreak of acute respiratory syndrome following exposure to waterproofing sprays occurred during the winter 2002-2003 in Switzerland. About 180 cases were reported by the Swiss Toxicological Information Centre between October 2002 and March 2003, whereas fewer than 10 cases per year had been recorded previously. The reported cases involved three brands of sprays containing a common waterproofing mixture, that had undergone a formulation change in the months preceding the outbreak. A retrospective analysis was undertaken in collaboration with the Swiss Toxicological Information Centre and the Swiss Registries for Interstitial and Orphan Lung Diseases to clarify the circumstances and possible causes of the observed health effects. Individual exposure data were generated with questionnaires and experimental emission measurements. The collected data was used to conduct numeric simulation for 102 cases of exposure. A classical two-zone model was used to assess the aerosol dispersion in the near- and far-field during spraying. The resulting assessed dose and exposure levels obtained were spread on large scales, of several orders of magnitude. No dose-response relationship was found between exposure indicators and health effects indicators (perceived severity and clinical indicators). Weak relationships were found between unspecific inflammatory response indicators (leukocytes, C-reactive protein) and the maximal exposure concentration. The results obtained disclose a high interindividual response variability and suggest that some indirect mechanism(s) predominates in the respiratory disease occurrence. Furthermore, no threshold could be found to define a safe level of exposure. These findings suggest that the improvement of environmental exposure conditions during spraying alone does not constitute a sufficient measure to prevent future outbreaks of waterproofing spray toxicity. More efficient preventive measures are needed prior to the marketing and distribution of new waterproofing agents.