966 resultados para Analytical results


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A multivariate calibration method to determine chemical compositions of systems with severely overlapped bands is proposed. Q mode factors are determined from the spectral data and subsequently rotated using the varimax and oblique transformation of Imbrie. The method is applied to two sets of simulated data to test the sensitivity of analytical results to random experimental error. The chemical concentrations of alanine and threonine mixture are determined from spectral data of the 302,5 - 548,5 nm region.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Electron transport in a self-consistent potential along a ballistic two-terminal conductor has been investigated. We have derived general formulas which describe the nonlinear current-voltage characteristics, differential conductance, and low-frequency current and voltage noise assuming an arbitrary distribution function and correlation properties of injected electrons. The analytical results have been obtained for a wide range of biases: from equilibrium to high values beyond the linear-response regime. The particular case of a three-dimensional Fermi-Dirac injection has been analyzed. We show that the Coulomb correlations are manifested in the negative excess voltage noise, i.e., the voltage fluctuations under high-field transport conditions can be less than in equilibrium.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Interlaboratorial programs are conducted for a number of purposes: to identify problems related to the calibration of instruments, to assess the degree of equivalence of analytical results among several laboratories, to attribute quantity values and its uncertainties in the development of a certified reference material and to verify the performance of laboratories as in proficiency testing, a key quality assurance technique, which is sometimes used in conjunction with accreditation. Several statistics tools are employed to assess the analytical results of laboratories participating in an intercomparison program. Among them are the z-score technique, the elypse of confidence and the Grubbs and Cochran test. This work presents the experience in coordinating an intercomparison exercise in order to determine Ca, Al, Fe, Ti and Mn, as impurities in samples of silicon metal of chemical grade prepared as a candidate for reference material.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The use of an internal standard (IS) in ET AAS can be considered a new trend after the commercial introduction of a simultaneous spectrometer. The evaluation of experimental data to choose the most appropriate IS can be done by comparing correlation graphs. They were used to verify the resemblance among the simultaneous measurements obtained for the analyte(s) and the IS by inductively coupled plasma optical emission spectrometry (ICPOES). The judicious selection of IS by using correlation graphs for determinations by ET AAS can be exploited to improve the precision and accuracy of the analytical results. Therefore, a new approach for studying the use of IS in ET AAS is presented.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A proficiency assay of the determination of dithiocarbamate pesticide residues in banana was carried out. Fourteen laboratories participated in this study. Homogeneity and stability testing were performed by INCQS on the samples sent to the laboratories. Analytical results supplied by the pesticide residues laboratory of the VWA/KvW, Amsterdam, Holland, were used to define the designated value for the thiram concentration in the study samples. RESULTS: Fifty percent of the participating laboratories had satisfactory results. Efforts are needed to improve the precision of the analytical results and to decrease the number of false negative results observed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The first computational implementation that automates the procedures involved in the calculation of infrared intensities using the charge-charge flux-dipole flux model is presented. The atomic charges and dipoles from the Quantum Theory of Atoms in Molecules (QTAIM) model was programmed for Morphy98, Gaussian98 and Gaussian03 programs outputs, but for the ChelpG parameters only the Gaussian programs are supported. Results of illustrative but new calculations for the water, ammonia and methane molecules at the MP2/6-311++G(3d,3p) theoretical level, using the ChelpG and QTAIM/Morphy charges and dipoles are presented. These results showed excellent agreement with analytical results obtained directly at the MP2/6-311++G(3d,3p) level of theory.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Eight trace elements were determined in 20 Brazilian brands of grape juice, distributed over the country. Highest measured concentrations (As: 0.016; Cd: 0.010; Cr: 0.060; Cu: 1.28; Ni: 0.032; Pb: 0.016; Sb: 0.0040 and Zn: 1.44 mg L-1) comply with Brazilian maximal tolerance levels for inorganic contaminants (As: 0.5; Cd: 0.5; Cr: 0.1; Cu: 30; Ni: 3; Pb: 0.4; Sb: 1 and Zn: 25 mg L-1). Determination of arsenic species has shown inorganic As(V) as predominant in most samples. Sodium concentrations, nowadays a major public health concern, were also measured, showing an average of 149 mg L-1. Analytical results for this element were much higher than label concentrations, showing the need for better quality control.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper describes a homemade autosampler for flow injection analysis (FIA), constructed with two step motors from old floppy disk drives (5¼-inch). The autosampler was connected to a computer through the parallel port and the sampling process was controlled by software in Quick Basic. The performance of the system was assessed by the determination of ammonium, based on the gaseous diffusion into a bromocresol purple solution, following the spectrophotometric determination of change in absorbance. The easy and simple construction is the main characteristics of this equipment and analytical results with RSD lower than 1% were obtained.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The measurement uncertainty is useful to estimate the confidence of analytical results. Nowadays, a result without the uncertainty statement cannot be considered reliable, but the scientific literature still lacks examples of the estimate of the measurement uncertainty. This paper presents a practical and reliable description of the measurement uncertainty estimation of the analytical determination of ethyl carbamate in cachaça by GC-IDMS. The isotope dilution technique (ID) associated with GC-MS was used to improve the accuracy. The uncertainty estimated corresponds to 10% of the mass fraction of ethyl carbamate (115 ± 11) ng/g, which is in agreement with ppb level.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Biogenic silica is used to describe compounds of hydrated silica (SiO2.nH2O), with specific shapes and sizes, deposited in plants. The chemical composition of biogenic silica and its stability in Jaraguá grass was studied in increasing concentration of NaOH. The analytical results demonstrated high concentration of Si, Al, Fe, Mg, P and low of Cu, Cd and Zn in the phytoliths composition. The silica bodies stability in NaOH solution with increasing concentration was different among the shapes and sizes. Silicified stomata and silicified plant tissues were dissolved along with the dumbbells because they are the less stable forms of biogenic silica.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents a quality assurance and quality control protocol in order to ensure the reliability of analytical results for the determination of acid volatile sulfides in environmental samples by potentiometry. The monitoring of the ion selective sensor readings must be realized continually and particularly in this situation where the analyte is susceptible to transformation and volatilization. Potentiometry with the standard addition was presented as a rapid, accurate, precise, feasible as well as a low cost technique. Concentrations of the analyte in the range of 0.49 to 1.02 mg L-1 were tested with percentage recoveries varying from 89 to 113%.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A simple, precise, rapid and low-cost potentiometric method for captopril determination in pure form and in pharmaceutical preparations is proposed. Captopril present in tablets containing known quantity of drug was potentiometrically titrated in aqueous solution with NaOH using a glass pH electrode, coupled to an autotitrator. No interferences were observed in the presence of common components of the tablets as lactose, microcrystalline cellulose, croscarmellose sodium, starch and magnesium stearate. The analytical results obtained by applying the proposed method compared very favorably with those obtained by the United States Pharmacopoeia Standard procedure. Recovery of captopril from various tablet dosage formulations range from 98.0 to 102.0%.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work, an effective and low-cost method for the determination of sodium or potassium diclofenac is proposed in its pure form and in their pharmaceutical preparations. The method is based on the reaction between diclofenac and tetrachloro-p-benzoquinone (p-chloranil), in methanol medium. This reaction was accelerated by irradiating of reactional mixture with microwave energy (1100 W) during 27 seconds, producing a charge transfer complex with a maximum absorption at 535 nm. The optimal reaction conditions values such as reagent concentration, heating time and stability of the reaction product were determined. Beer's law is obeyed in a concentration range from of 1.25x10-4 to 2.00x10-3 mol l-1 with a correlation coefficient of 0.9993 and molar absorptivity of 0.49 x10³ l mol-1 cm-1. The limit of detection (LOD) was 1.35x10-5 mol l-1 and the limit of quantification (LOQ) was 4.49x10-5 mol l-1. In the presence of the common excipients, such as glucose, lactose, talc, starch, magnesium stearate, sodium sulphite, titanium dioxide, polyethyleneglycol, polyvinylpirrolidone, mannitol and benzilic alcohol no interferences were observed. The analytical results obtained by applying the proposed method compare very favorably with those given by the United States Pharmacopeia standard procedure. Recoveries of diclofenac from various pharmaceutical preparations were within 95.9% to 103.3%, with standard deviations ranging from 0.2% to 1.8%.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A new, simple, precise, rapid and low-cost spectrophotometric method for methyldopa determination in pharmaceutical preparations is described. This method is based on the complexation reaction of methyldopa with molybdate. Absorbance of the resulting yellow coloured product is measured at 410 nm. Beer's Law is obeyed in a concentration range of 50 - 200 µg ml-1 methyldopa with an excellent correlation coefficient (r = 0.9999). No interference was observed from common excipients in formulations. The results show a simple, accurate, fast and readily applied method to the determination of methyldopa in pharmaceutical products. The analytical results obtained for these products by the proposed method are in agreement with those of the Brazilian Pharmacopoeia procedure at 95% confidence level.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Käytetyn voiteluöljyn regeneroinnissa muodostuu prosessivettä useista lähteistä. Tehokas päästöjenhallinta on yksi tärkeimmistä tavoitteista regenerointilaitoksen operoinnissa ja sen takia sitä tulee kehittää jatkuvasti entistä paremmaksi. Tavoitteisiin pääsemiseksi on oleellista tunnistaa vesienkäsittelyprosessin laadullinen massatase ja laadunvaihtelut ajotilanteiden mukaan. Työssä tutkitaan ja analysoidaan veden sisältämiä epäpuhtauksia sekä kirjallisuuslähteiden perusteella, että standardimenetelmillä ja modifioiduilla menetelmillä, joilla on akkreditointi. Analyysituloksista muodostetaan laadullinen massatase, josta nähdään epäpuhtauksien ja niitä kuvaavien parametrien kuormitukset kussakin prosessivesivirrassa. Tulosten perusteella arvioidaan nykyisen vesienkäsittelyn tehokkuutta, sen säätömahdollisuuksia ja kehitystarvetta. Tarkastelun ulkopuolelle kuitenkin jätetään vesienkäsittelystä ulosjohdettavan prosessiveden puhdistuslaitos. Tutkimusten perusteella regenerointilaitoksessa muodostuvien prosessivesien epäpuhtaudet koostuvat öljystä, BTEX-yhdisteistä, fenoliyhdisteistä, liuottimista, polttoaineiden ja voiteluöljyjen lisäaineista, typpi- ja rikkiyhdisteistä, metalliyhdisteistä sekä kiintoaineesta. Öljy jakautuu kevyisiin (C5-C10), keskiraskaisiin (C10-21) ja raskaisiin (C21-40) jakeisiin. Vesienkäsittelyssä suurin osa öljystä ja epäpuhtauksista saadaan erottumaan vedestä, jolloin puhdistuslaitokselle päätyy jäämäpitoisuudet öljyä, haihtuvia yhdisteitä sekä muita epäpuhtauksia. Puhdistuslaitosta kuormittavat eniten liuenneet orgaaniset yhdisteet sekä korkeaa kemiallista hapenkulutusta aiheuttavat epäorgaaniset yhdisteet (suolat), joiden erottamista prosessivesistä on syytä tulevaisuudessa kehittää.