944 resultados para Abdominal aortic aneurysm (AAA)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To elucidate the association of impaired pulmonary status (IPS) and diabetes mellitus (DM) with clinical outcome and the incidences of aortic neck dilatation and type I endoleak after elective endovascular infrarenal aortic aneurysm repair (EVAR). METHODS: In 164 European institutions participating in the EUROSTAR registry, 6383 patients (5985 men; mean age 72.4+/-7.6 years) underwent EVAR. Patients were divided into patients without versus with IPS or with/without DM. Clinical assessment and contrast-enhanced computed tomography (CT) were performed at 1, 3, 6, 12, 18, and 24 months and annually thereafter. Cumulative endpoint analysis comprised death, aortic rupture, type I endoleak, endovascular reintervention, and surgical conversion. RESULTS: Prevalence of IPS was 2733/6383 (43%) and prevalence of DM was 810/6383 (13%). Mean follow-up was 21.1+/-18.4 months. Thirty-day mortality, AAA rupture, and conversion rates did not differ between patients with versus without IPS and between patients with versus without DM. All-cause and AAA-related mortality, respectively, were significantly higher in patients with IPS compared to patients with normal pulmonary status (31.0% versus 19.0%, p<0.0001 and 6.8% versus 3.3%, p = 0.0057) throughout follow-up. In multivariate analysis adjusted for smoking, age, gender, comorbidities, fitness for open repair, co-existing common iliac aneurysm, neck and aneurysm size, arterial angulations, aneurysm classification, endograft oversizing >or=15%, and type of stent-graft, the presence of IPS was not associated with significantly higher rates of aortic neck dilatation (30.6% versus 38.0%, p>0.05) and did not influence cumulative rates of type I endoleak, endovascular reintervention, or conversion to open surgery (p>0.05). Similarly, the presence of DM did not influence the above-mentioned study endpoints. CONCLUSION: In contrast to observations regarding the natural course of AAAs, impaired pulmonary status does not negatively influence aortic neck dilatation, while the presence of diabetes does not protect from these dismal events after EVAR.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To compare clinical outcomes of endovascular and open aortic repair of abdominal aortic aneurysms (AAAs) in young patients at low risk. It was hypothesized that endovascular aneurysm repair (EVAR) compares favorably with open aneurysm repair (OAR) in these patients. MATERIALS AND METHODS: Twenty-five patients aged 65 years or younger with a low perioperative surgical risk profile underwent EVAR at a single institution between April 1994 and May 2007 (23 men; mean age, 62 years+/-2.8). A sex- and risk-matched control group of 25 consecutive patients aged 65 years or younger who underwent OAR was used as a control group (23 men; mean age, 59 years+/-3.9). Patient outcomes and complications were classified according to Society of Vascular Surgery/International Society for Cardiovascular Surgery reporting standards. RESULTS: Mean follow-up times were 7.1 years+/-3.2 after EVAR and 5.9 years+/-1.8 after OAR (P=.1020). Total complication rates were 20% after EVAR and 52% after OAR (P=.0378), and all complications were mild or moderate. Mean intensive care unit times were 0.2 days+/-0.4 after EVAR and 1.1 days+/-0.4 after OAR (P<.0001) and mean lengths of hospital stay were 2.3 days+/-1.0 after EVAR and 5.0 days+/-2.1 after OAR (P<.0001). Cumulative rates of long-term patient survival did not differ between EVAR and OAR (P=.144). No AAA-related deaths or aortoiliac ruptures occurred during follow-up for EVAR and OAR. In addition, no surgical conversions were necessary in EVAR recipients. Cumulative rates of freedom from secondary procedures were not significantly different between the EVAR and OAR groups (P=.418). Within a multivariable Cox proportional-hazards analysis adjusted for patient age, maximum AAA diameter, and cardiac risk score, all-cause mortality rates (odds ratio [OR], 0.125; 95% CI, 0.010-1.493; P=.100) and need for secondary procedures (OR, 5.014; 95% CI, 0.325-77.410; P=.537) were not different between EVAR and OAR. CONCLUSIONS: Results from this observational study indicate that EVAR offers a favorable alternative to OAR in young patients at low risk.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel method for generating patient-specific high quality conforming hexahedral meshes is presented. The meshes are directly obtained from the segmentation of patient magnetic resonance (MR) images of abdominal aortic aneu-rysms (AAA). The MRI permits distinguishing between struc-tures of interest in soft tissue. Being so, the contours of the lumen, the aortic wall and the intraluminal thrombus (ILT) are available and thus the meshes represent the actual anato-my of the patient?s aneurysm, including the layered morpholo-gies of these structures. Most AAAs are located in the lower part of the aorta and the upper section of the iliac arteries, where the inherent tortuosity of the anatomy and the presence of the ILT makes the generation of high-quality elements at the bifurcation is a challenging task. In this work we propose a novel approach for building quadrilateral meshes for each surface of the sectioned geometry, and generating conforming hexahedral meshes by combining the quadrilateral meshes. Conforming hexahedral meshes are created for the wall and the ILT. The resulting elements are evaluated on four patients? datasets using the Scaled Jacobian metric. Hexahedral meshes of 25,000 elements with 94.8% of elements well-suited for FE analysis are generated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Aortic aneurysm and dissection are important causes of death in older people. Ruptured aneurysms show catastrophic fatality rates reaching near 80%. Few population-based mortality studies have been published in the world and none in Brazil. The objective of the present study was to use multiple-cause-of-death methodology in the analysis of mortality trends related to aortic aneurysm and dissection in the state of Sao Paulo, between 1985 and 2009. Methods: We analyzed mortality data from the Sao Paulo State Data Analysis System, selecting all death certificates on which aortic aneurysm and dissection were listed as a cause-of-death. The variables sex, age, season of the year, and underlying, associated or total mentions of causes of death were studied using standardized mortality rates, proportions and historical trends. Statistical analyses were performed by chi-square goodness-of-fit and H Kruskal-Wallis tests, and variance analysis. The joinpoint regression model was used to evaluate changes in age-standardized rates trends. A p value less than 0.05 was regarded as significant. Results: Over a 25-year period, there were 42,615 deaths related to aortic aneurysm and dissection, of which 36,088 (84.7%) were identified as underlying cause and 6,527 (15.3%) as an associated cause-of-death. Dissection and ruptured aneurysms were considered as an underlying cause of death in 93% of the deaths. For the entire period, a significant increased trend of age-standardized death rates was observed in men and women, while certain non-significant decreases occurred from 1996/2004 until 2009. Abdominal aortic aneurysms and aortic dissections prevailed among men and aortic dissections and aortic aneurysms of unspecified site among women. In 1985 and 2009 death rates ratios of men to women were respectively 2.86 and 2.19, corresponding to a difference decrease between rates of 23.4%. For aortic dissection, ruptured and non-ruptured aneurysms, the overall mean ages at death were, respectively, 63.2, 68.4 and 71.6 years; while, as the underlying cause, the main associated causes of death were as follows: hemorrhages (in 43.8%/40.5%/13.9%); hypertensive diseases (in 49.2%/22.43%/24.5%) and atherosclerosis (in 14.8%/25.5%/15.3%); and, as associated causes, their principal overall underlying causes of death were diseases of the circulatory (55.7%), and respiratory (13.8%) systems and neoplasms (7.8%). A significant seasonal variation, with highest frequency in winter, occurred in deaths identified as underlying cause for aortic dissection, ruptured and non-ruptured aneurysms. Conclusions: This study introduces the methodology of multiple-causes-of-death to enhance epidemiologic knowledge of aortic aneurysm and dissection in Sao Paulo, Brazil. The results presented confer light to the importance of mortality statistics and the need for epidemiologic studies to understand unique trends in our own population.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Aortic aneurysm and dissection are important causes of death in older people. Ruptured aneurysms show catastrophic fatality rates reaching near 80%. Few population-based mortality studies have been published in the world and none in Brazil. The objective of the present study was to use multiple-cause-of-death methodology in the analysis of mortality trends related to aortic aneurysm and dissection in the state of Sao Paulo, between 1985 and 2009. Methods: We analyzed mortality data from the Sao Paulo State Data Analysis System, selecting all death certificates on which aortic aneurysm and dissection were listed as a cause-of-death. The variables sex, age, season of the year, and underlying, associated or total mentions of causes of death were studied using standardized mortality rates, proportions and historical trends. Statistical analyses were performed by chi-square goodness-of-fit and H Kruskal-Wallis tests, and variance analysis. The joinpoint regression model was used to evaluate changes in age-standardized rates trends. A p value less than 0.05 was regarded as significant. Results: Over a 25-year period, there were 42,615 deaths related to aortic aneurysm and dissection, of which 36,088 (84.7%) were identified as underlying cause and 6,527 (15.3%) as an associated cause-of-death. Dissection and ruptured aneurysms were considered as an underlying cause of death in 93% of the deaths. For the entire period, a significant increased trend of age-standardized death rates was observed in men and women, while certain non-significant decreases occurred from 1996/2004 until 2009. Abdominal aortic aneurysms and aortic dissections prevailed among men and aortic dissections and aortic aneurysms of unspecified site among women. In 1985 and 2009 death rates ratios of men to women were respectively 2.86 and 2.19, corresponding to a difference decrease between rates of 23.4%. For aortic dissection, ruptured and non-ruptured aneurysms, the overall mean ages at death were, respectively, 63.2, 68.4 and 71.6 years; while, as the underlying cause, the main associated causes of death were as follows: hemorrhages (in 43.8%/40.5%/13.9%); hypertensive diseases (in 49.2%/22.43%/24.5%) and atherosclerosis (in 14.8%/25.5%/15.3%); and, as associated causes, their principal overall underlying causes of death were diseases of the circulatory (55.7%), and respiratory (13.8%) systems and neoplasms (7.8%). A significant seasonal variation, with highest frequency in winter, occurred in deaths identified as underlying cause for aortic dissection, ruptured and non-ruptured aneurysms. Conclusions: This study introduces the methodology of multiple-causes-of-death to enhance epidemiologic knowledge of aortic aneurysm and dissection in São Paulo, Brazil. The results presented confer light to the importance of mortality statistics and the need for epidemiologic studies to understand unique trends in our own population.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Transcatheter aortic valve replacement (TAVR) as well as thoracic and abdominal endovascular aortic repair (TEVAR and EVAR) rely on accurate pre- and postprocedural imaging. This review article discusses the application of imaging, including preprocedural assessment and measurements as well as postprocedural imaging of complications. Furthermore, the exciting perspective of computational fluid dynamics (CFD) based on cross-sectional imaging is presented. TAVR is a minimally invasive alternative for treatment of aortic valve stenosis in patients with high age and multiple comorbidities who cannot undergo traditional open surgical repair. Given the lack of direct visualization during the procedure, pre- and peri-procedural imaging forms an essential part of the intervention. Computed tomography angiography (CTA) is the imaging modality of choice for preprocedural planning. Routine postprocedural follow-up is performed by echocardiography to confirm treatment success and detect complications. EVAR and TEVAR are minimally invasive alternatives to open surgical repair of aortic pathologies. CTA constitutes the preferred imaging modality for both preoperative planning and postoperative follow-up including detection of endoleaks. Magnetic resonance imaging is an excellent alternative to CT for postoperative follow-up, and is especially beneficial for younger patients given the lack of radiation. Ultrasound is applied in screening and postoperative follow-up of abdominal aortic aneurysms, but cross-sectional imaging is required once abnormalities are detected. Contrast-enhanced ultrasound may be as sensitive as CTA in detecting endoleaks.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Accurate measurement of abdominal aortic aneurysms is necessary to predict rupture risk and, more recently, to follow aneurysm sac behavior following endovascular repair. Up until this point, aneurysm diameter has been the most common measurement utilized for these purposes. Although aneurysm diameter is predictive of rupture, accurate measurement is hindered by such factors as aortic tortuosity and interobserver variability, and it does not account for variations in morphology such as saccular aneurysms. Additionally, decreases in aneurysm diameter do not completely describe the somewhat complex remodeling seen following endovascular repair of aortic aneurysms. Measurement of aneurysm volume has the advantage of describing aneurysm morphology in a multidimensional fashion, but it has not been readily available or easily measured until recently. This has changed with the introduction of commercially available software tools that permit quicker and easier to perform volume measurements. Whether it is time for volume to replace, or compliment, diameter is the subject of the current debate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ruptured abdominal aortic aneurysm (rAAA) with an arterio-venous fistula is a rare phenomenon. We report a case where the coincidence of significant coronary stenosis was masking the main problem of an infra-renal aortic aneurysm rupture.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In order to perform finite element (FE) analyses of patient-specific abdominal aortic aneurysms, geometries derived from medical images must be meshed with suitable elements. We propose a semi-automatic method for generating conforming hexahedral meshes directly from contours segmented from medical images. Magnetic resonance images are generated using a protocol developed to give the abdominal aorta high contrast against the surrounding soft tissue. These data allow us to distinguish between the different structures of interest. We build novel quadrilateral meshes for each surface of the sectioned geometry and generate conforming hexahedral meshes by combining the quadrilateral meshes. The three-layered morphology of both the arterial wall and thrombus is incorporated using parameters determined from experiments. We demonstrate the quality of our patient-specific meshes using the element Scaled Jacobian. The method efficiently generates high-quality elements suitable for FE analysis, even in the bifurcation region of the aorta into the iliac arteries. For example, hexahedral meshes of up to 125,000 elements are generated in less than 130 s, with 94.8 % of elements well suited for FE analysis. We provide novel input for simulations by independently meshing both the arterial wall and intraluminal thrombus of the aneurysm, and their respective layered morphologies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Lifelong surveillance after endovascular repair (EVAR) of abdominal aortic aneurysms (AAA) is considered mandatory to detect potentially life-threatening endograft complications. A minority of patients require reintervention but cannot be predictively identified by existing methods. This study aimed to improve the prediction of endograft complications and mortality, through the application of machine-learning techniques. Methods Patients undergoing EVAR at 2 centres were studied from 2004-2010. Pre-operative aneurysm morphology was quantified and endograft complications were recorded up to 5 years following surgery. An artificial neural networks (ANN) approach was used to predict whether patients would be at low- or high-risk of endograft complications (aortic/limb) or mortality. Centre 1 data were used for training and centre 2 data for validation. ANN performance was assessed by Kaplan-Meier analysis to compare the incidence of aortic complications, limb complications, and mortality; in patients predicted to be low-risk, versus those predicted to be high-risk. Results 761 patients aged 75 +/- 7 years underwent EVAR. Mean follow-up was 36+/- 20 months. An ANN was created from morphological features including angulation/length/areas/diameters/ volume/tortuosity of the aneurysm neck/sac/iliac segments. ANN models predicted endograft complications and mortality with excellent discrimination between a low-risk and high-risk group. In external validation, the 5-year rates of freedom from aortic complications, limb complications and mortality were 95.9% vs 67.9%; 99.3% vs 92.0%; and 87.9% vs 79.3% respectively (p0.001) Conclusion This study presents ANN models that stratify the 5-year risk of endograft complications or mortality using routinely available pre-operative data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introdução: A correção cirúrgica do aneurisma da aorta abdominal (AAA), por Endovascular Aneurysm Repair (EVAR) ou cirurgia convencional (CC), pode agravar a função renal a curto prazo. Esta complicação, mais frequente nos doentes com insuficiência renal crónica (IRC), associa-se a pior prognóstico a longo prazo. O objetivo deste trabalho foi quantificar o agravamento da função renal após reparação do AAA em doentes com IRC prévia e demonstrar o consequente aumento da morbimortalidade. Métodos: Estudo retrospetivo em doentes com IRC estádios Chronic Kidney Disease 3-4 (TFGe 15-59ml/min), submetidos a correção eletiva de AAA entre fevereiro/2011 e fevereiro/2015 numa instituição terciária. Variáveis estudadas: idade, sexo, tipo de intervenção (convencional/EVAR) e estádio CKD. Endpoints: variação da creatinina e taxa de filtração glomerular com a cirurgia, complicações renais pós-operatórias, necessidade de reintervenção cirúrgica e mortalidade. A análise estatística foi realizada em SPSS. Resultados: Foram incluídos 71doentes. Quinze doentes (21%) foram operados por CC e 56 (78%) por EVAR. À data da intervenção, os doentes encontravam-se nos seguintes estádios da DRC: CKD 3 --- 65 (91%) e CKD 4 --- 6 (9%). A variac¸ão da TFG com a cirurgia foi −1,08±18,01mg/dl. Verificou-se IRC agudizada pós-operatória em 22 (31%) doentes e necessidade de diálise em 5 (7%). A mortalidade global foi 8,5%. Os doentes operados por EVAR tinham DRC mais avançada pré-operatoriamente, mas apresentaram menor agravamento da função renal. Variação TFG: EVAR 1,14±16,26ml/min vs. CC 9,40±22,11ml/min (p=0,022); variação creatinina: EVAR 0,17±1,03mg/dl vs. CC 0,81±1,47mg/dl (p=0,02). A agudização da IRC pós-operatória foi superior no grupo CC (53,3 vs. 28,6%; p=0,072), assim como a necessidade de diálise (20 vs. 3,6%, p=0,06). Os 6 doentes que faleceram (EVAR: 3; CC: 3) apresentaram maior agravamento da função renal (variação da creatinina: 1,41±1,63mg/dl vs. 0,20±1,07mg/dl, p=0,001; variação da TFG: −19,0±16,55ml/min; 0,57±17,34ml/min, p=0,007) e necessidade de diálise (50 vs. 3,1%, p=0,003). Conclusão: Os resultados demonstraram uma tendência para uma menor probabilidade de IRA, menor necessidade de diálise pós-operatória e menor mortalidade nos doentes tratados por EVAR. Contudo, o impacto da administração de contraste a médio/longo prazo, decorrente dos programas de vigilância pós-EVAR, deve ser considerado. Julgamos ser possível considerar que a realização de EVAR para o tratamento de doentes com AAA e IRC é um procedimento pelo menos tão seguro como a CC.