941 resultados para 45-395A


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

采用真空熔炼法制备了Ti45Zr35Ni20合金,研究了合金在不同温度下的电化学贮氢性能。结果表明,Ti45Zr35-Ni20电极的电化学性能随着温度而变化,温度从323 K升高到343 K时,电极的活化次数从22次减少到8次,放电容量从86.1 mAh/g增到135.0 mAh/g,快速放电能力也有所提高,然而,高温使电极的循环稳定性显著下降,自放电率增大。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

研究了XPS诱导的CeM5N45N45俄歇峰,由于其终态空穴处于芯能级,故俄歇峰有较好的分辨率。从CeM5N45N45的俄歇峰可获得中心离子Ce的电子云密度等信息,发现其俄歇参数与配位体的极化变形程度有关,从而解释了双烯烃定向聚合必须有稀土卤氧键存在的原因。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The first thermodynamic dissociation constants of glycine in 5, 15 mass % glucose + water mixed solvents at five temperatures from 5 to 45-degrees-C have been determined from precise emf measurements of a cell without liquid junction using hydrogen and Ag-AgCl electrodes and a new method of polynomial approximation proposed on the basis of Pitzer's electrolytic solution theory in our previous paper. The results obtained from both methods agree within experimental error. The standard free energy of transfer for HCl from water to aqueous mixed solvent have been calculated and the results are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

以Fourier瞬态传热方程为基础,确定了强流脉冲离子束(HIPIB)热效应的基本传热方程,对靶材45钢进行不同能量参数的HIPIB辐照热效应的模拟计算.针对离子注入金属内部的情况,在模拟束流加载方式上分别采用体加载和面加载,比较了两种加载计算结果之间的差距.本算法的另一个改进就是在高能量辐照下,用单元死活法对蚀坑部分材料的消失进行模拟.结果表明,用单元死活法模拟单元的失效,更能符合HIPIB辐照金属表面热效应的蚀坑机制;单元死活法对靶材的升温过程没有明显影响,但对冷却阶段,可以显著提高模拟的精度.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Practice Links is a free e-publication for practitioners working in Irish social services, voluntary and nongovernmental sectors. Practice Links was created to enable practitioners to keep up-to-date with new publications, electronic resources and conference opportunities. Issue 45 unveils a new, regular section in the publication entitled Practice Signposts. This section aims to promote quality research- informed databases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on a study comparing absolute K-alpha yield from Ti foils measured with a calibrated system of an X-ray CCD coupled to a curved LiF Von-Hamos crystal spectrometer to the difference in the signals measured simultaneously with two similar photodiodes fitted with two different filters. Our data indicate that a combination of photodiodes with different filters could be developed into an alternative and inexpensive diagnostic for monitoring single shot pulsed emission in a narrow band of X-ray region.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is shown that a side-fed bifilar helix antenna with a single feed, can generate a slant 451 linearly polarized onmidirectional toroidal pattern. The antenna has a low profile and does not require a ground plane. The bifilar helix antenna provides slant 45 degrees polarization over a solid angle of almost 4 pi steradians as compared to a crossed dipole which generates a tilted 45 degrees linearly, polarized pattern only over a solid angle of 1.14 pi steradians. The computed results are validated by experimental data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the on-body performance of a range of wearable antennas was investigated by measuring vertical bar S-21 vertical bar path gain between two devices mounted on tissue-equivalent numerical and experimental phantoms, representative of human muscle tissue at 2.45 GHz. In particular, the study focused on the performance of a compact higher mode microstrip patch antenna (HMMPA) with a profile as low as lambda/20. The 5- and 10-mm-high HMMPA prototypes had an impedance bandwidth of 6.7% and 8.6%, respectively, sufficient for the operating requirements of the 2.45-GHz industrial, scientific, and medical (ISM) band and both antennas offered 11-dB higher path gain compared to a fundamental-mode microstrip patch antenna. It was also dernonstrated that a 7-dB improvement in path gain can be obtained for a fundamental-mode patch through the addition of a shortening wall. Notably, on-body HMMPA performance was comparable to a quarter wave monopole antenna on the same size of ground-plane, mounted normal to the tissue surface, indicating that the low-profile and physically more robust antenna is a promising solution for bodyworn antenna applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Modeling of on-body propagation channels is of paramount importance to those wishing to evaluate radio channel performance for wearable devices in body area networks (BANs). Difficulties in modeling arise due to the highly variable channel conditions related to changes in the user's state and local environment. This study characterizes these influences by using time-series analysis to examine and model signal characteristics for on-body radio channels in user stationary and mobile scenarios in four different locations: anechoic chamber, open office area, hallway, and outdoor environment. Autocorrelation and cross-correlation functions are reported and shown to be dependent on body state and surroundings. Autoregressive (AR) transfer functions are used to perform time-series analysis and develop models for fading in various on-body links. Due to the non-Gaussian nature of the logarithmically transformed observed signal envelope in the majority of mobile user states, a simple method for reproducing the failing based on lognormal and Nakagami statistics is proposed. The validity of the AR models is evaluated using hypothesis testing, which is based on the Ljung-Box statistic, and the estimated distributional parameters of the simulator output compared with those from experimental results.