936 resultados para 380109 Psychological Methodology, Design and Analysis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes a multilayer localized surface plasmon resonance (LSPR) graphene biosensor that includes a layer of graphene sheet on top of the gold layer, and the use of different coupled configuration of a laser beam. The study also investigates the enhancement of the sensitivity and detection accuracy of the biosensor through monitoring biomolecular interactions of biotin-streptavidin with the graphene layer on the gold thin film. Additionally, the role of thin films of gold, silver, copper and aluminum in the performance of the biosensor is separately investigated for monitoring the binding of streptavidin to the biotin groups. The performance of the LSPR graphene biosensor is theoretically and numerically assessed in terms of sensitivity, adsorption efficiency, and detection accuracy under varying conditions, including the thickness of biomolecule layer, number of graphene layers and operating wavelength. Enhanced sensitivity and improved adsorption efficiency are obtained for the LSPR graphene biosensor in comparison with its conventional counterpart; however, detection accuracy under the same resonance condition is reduced by 5.2% with a single graphene sheet. This reduction in detection accuracy (signal to noise ratio) can be compensated for by introducing an additional layer of silica doped B2O3 (sdB2O3) placed under the graphene layer. The role of prism configuration, prism angle and the interface medium (air and water) is also analyzed and it is found that the LSPR graphene biosensor has better sensitivity with triangular prism, higher prism angle, lower operating wavelength and larger number of graphene layers. The approach involves a plot of a reflectivity curve as a function of the incidence angle. The outcomes of this investigation highlight the ideal functioning condition corresponding to the best design parameters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Designed a multilayer SPR biosensor to improve the detection sensitivity and accuracy simultaneously. Developed a design procedure to identify optimum design parameters for SPR biosensing. Devised a new detection measurement technique based on S-parameters for SPR biosensing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents design and simulation of a circular meander dipole antenna at the industrial, scientific, and medical band of 915 MHz for energy scavenging in a passive head-mountable deep brain stimulation device. The interaction of the proposed antenna with a rat body is modeled and discussed. In the antenna, the radiating layer is meandered, and a FR-4 substrate is used to limit the radius and height of the antenna to 14 mm and 1.60 mm, respectively. The resonance frequency of the designed antenna is 915 MHz and the bandwidth of 15 MHz at a return loss of -10 dB in free space. To model the interaction of the antenna with a rat body, two aspects including functional and biological are considered. The functional aspect includes input impedance, resonance frequency, gain pattern, radiation efficiency of the antenna, and the biological aspect involves electric field distribution, and SAR value. A complete rat model is used in the finite difference time domain based EM simulation software XFdtd. The simulated results demonstrate that the specific absorption rate distributions occur within the skull in the rat model, and their values are higher than the standard regulated values for the antenna receiving power of 1W.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents an analysis of optimum rectifier circuits for wireless energy harvesting in deep brain stimulation (DBS) devices. Since DBS demands compact and low power consumption devices, small, high conversion efficient, and high output voltage rectifiers need to be developed. The investigation that is presented in this paper is analytical and simulated based. Analysis on a variety of circuit configurations brings more evidence to improve the performance of rectifiers. Analytical parameters influencing the output DC voltage and the efficiency of the rectifiers are described. The operating frequency of the 915 MHz industrial, scientific and medical (ISM) radio band is used in this study. The maximum conversion efficiency of the LC matched half wave rectifier, the Greinacher voltage doubler, the Delon doubler, and the 2-stage voltage multiplier is obtained as 56.34%, 74.45%, 71.48%, and 31.44%, respectively, at the 30 dBm input power level. The corresponding maximum output DC voltages are 6.27 V, 16.83 V, 13.36 V, and 9.20 V. Thus the Greinacher voltage doubler is deemed as the best configuration according to the conversion efficiency and the output voltage measurements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents an Electrowetting-on-Dielectric (EWOD) device with optimized insulating layers operated by low actuation voltage. The device consists of an electrode array on a silicon substrate, covered by a dielectric layer and a hydrophobic layer. To characterize the performance of the device, simulations are performed for the dielectric layer of Sio2 and the hydrophobic layer of Sio2, Su-8 and Parylene C at different voltages. The volume finite difference approach of the Coventorware software was used to carry out the simulations. Two different molar of di-ionized water droplet were considered in the simulations. It was observed that the device having the Sio2 dielectric layer and the Parylene C hydrophobic layer moved the 1M KCL (potassium chloride) droplet at the actuation voltage of 25V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study is to design a low-cost planar Archimedean dipole antenna for batteryless transcranial direct current stimulation devices. The antenna parameters including resonance frequency, radiation efficiency, radiation pattern, and gain are simulated using finite difference time domain based electromagnetic simulation software XFdtd. The proposed antenna is simulated with low-cost FR4 PCB substrate of thickness of 1.6 mm. The antenna is designed with half wavelength of resonant frequency and fed with a matching line. The target frequency band is the industrial, scientific and medical (ISM) band of 915 MHz which is in the simulated band width of 31 MHz (903-934MHz). Moreover, since the bio-effect of specific absorption rate by radio frequency electromagnetic wave for power harvesting is an important concern, we try to find out the safety limit. Thus a quantitative analysis of distributions of electric field and power absorption in anatomical human head model by the far field radio frequency energy received by our designed antenna has been presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Today’s power system network has become more complex and it has more responsibilities and challenges to provide secure, reliable and quality energysupply to the communities. A small entity of electrical network known as Microgrid (MG) is more popular nowadays to enhance reliablity and secure level of energy supply, in case of any energy crisis in the utility network. The MG can also provide clean energy supply by integrating renewable energy sources effectively. TheMG with small scale solar photovoltaic (PV) power system is more suitable to provide reliable and clean energy supply for remote or urban communities in residential level. This paper presents the basic analysis study of stand-alone solar photovoltaic (PV) MG power system which has been developed with the aid of Matlab - Simulink software, on the basis of residential load profile and solar exposure level in a particular area of Geelong, Victoria State. The simulation result depicts the control behavior of MG power system with optimum sizing of PV (4.385 kW)and battery storage (480Ah/48V) facility, fulfills daily energy needs in residential load level. This study provides a good platform to develop an effective and reliable stand-alone MG power system for the remote communities in the near future.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work shows the design, simulation, and analysis of two optical interconnection networks for a Dataflow parallel computer architecture. To verify the optical interconnection network performance on the Dataflow architecture, we have analyzed the load balancing among the processors during the parallel programs executions. The load balancing is a very important parameter because it is directly associated to the dataflow parallelism degree. This article proves that optical interconnection networks designed with simple optical devices can provide efficiently the dataflow requirements of a high performance communication system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents an efficient approach based on a recurrent neural network for solving constrained nonlinear optimization. More specifically, a modified Hopfield network is developed, and its internal parameters are computed using the valid-subspace technique. These parameters guarantee the convergence of the network to the equilibrium points that represent an optimal feasible solution. The main advantage of the developed network is that it handles optimization and constraint terms in different stages with no interference from each other. Moreover, the proposed approach does not require specification for penalty and weighting parameters for its initialization. A study of the modified Hopfield model is also developed to analyse its stability and convergence. Simulation results are provided to demonstrate the performance of the proposed neural network.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

1. Distance sampling is a widely used technique for estimating the size or density of biological populations. Many distance sampling designs and most analyses use the software Distance. 2. We briefly review distance sampling and its assumptions, outline the history, structure and capabilities of Distance, and provide hints on its use. 3. Good survey design is a crucial prerequisite for obtaining reliable results. Distance has a survey design engine, with a built-in geographic information system, that allows properties of different proposed designs to be examined via simulation, and survey plans to be generated. 4. A first step in analysis of distance sampling data is modeling the probability of detection. Distance contains three increasingly sophisticated analysis engines for this: conventional distance sampling, which models detection probability as a function of distance from the transect and assumes all objects at zero distance are detected; multiple-covariate distance sampling, which allows covariates in addition to distance; and mark–recapture distance sampling, which relaxes the assumption of certain detection at zero distance. 5. All three engines allow estimation of density or abundance, stratified if required, with associated measures of precision calculated either analytically or via the bootstrap. 6. Advanced analysis topics covered include the use of multipliers to allow analysis of indirect surveys (such as dung or nest surveys), the density surface modeling analysis engine for spatial and habitat-modeling, and information about accessing the analysis engines directly from other software. 7. Synthesis and applications. Distance sampling is a key method for producing abundance and density estimates in challenging field conditions. The theory underlying the methods continues to expand to cope with realistic estimation situations. In step with theoretical developments, state-of- the-art software that implements these methods is described that makes the methods accessible to practicing ecologists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The elimination of all external incisions is an important step in reducing the invasiveness of surgical procedures. Natural Orifice Translumenal Endoscopic Surgery (NOTES) is an incision-less surgery and provides explicit benefits such as reducing patient trauma and shortening recovery time. However, technological difficulties impede the widespread utilization of the NOTES method. A novel robotic tool has been developed, which makes NOTES procedures feasible by using multiple interchangeable tool tips. The robotic tool has the capability of entering the body cavity through an orifice or a single incision using a flexible articulated positioning mechanism and once inserted is not constrained by incisions, allowing for visualization and manipulations throughout the cavity. Multiple interchangeable tool tips of the robotic device initially consist of three end effectors: a grasper, scissors, and an atraumatic Babcock clamp. The tool changer is capable of selecting and switching between the three tools depending on the surgical task using a miniature mechanism driven by micro-motors. The robotic tool is remotely controlled through a joystick and computer interface. In this thesis, the following aspects of this robotic tool will be detailed. The first-generation robot is designed as a conceptual model for implementing a novel mechanism of switching, advancing, and controlling the tool tips using two micro-motors. It is believed that this mechanism achieves a reduction in cumbersome instrument exchanges and can reduce overall procedure time and the risk of inadvertent tissue trauma during exchanges with a natural orifice approach. Also, placing actuators directly at the surgical site enables the robot to generate sufficient force to operate effectively. Mounting the multifunctional robot on the distal end of an articulating tube provides freedom from restriction on the robot kinematics and helps solve some of the difficulties otherwise faced during surgery using NOTES or related approaches. The second-generation multifunctional robot is then introduced in which the overall size is reduced and two arms provide 2 additional degrees of freedom, resulting in feasibility of insertion through the esophagus and increased dexterity. Improvements are necessary in future iterations of the multifunctional robot; however, the work presented is a proof of concept for NOTES robots capable of abdominal surgical interventions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Acute respiratory distress syndrome (ARDS) is associated with high in-hospital mortality. Alveolar recruitment followed by ventilation at optimal titrated PEEP may reduce ventilator-induced lung injury and improve oxygenation in patients with ARDS, but the effects on mortality and other clinical outcomes remain unknown. This article reports the rationale, study design, and analysis plan of the Alveolar Recruitment for ARDS Trial (ART). Methods/Design: ART is a pragmatic, multicenter, randomized (concealed), controlled trial, which aims to determine if maximum stepwise alveolar recruitment associated with PEEP titration is able to increase 28-day survival in patients with ARDS compared to conventional treatment (ARDSNet strategy). We will enroll adult patients with ARDS of less than 72 h duration. The intervention group will receive an alveolar recruitment maneuver, with stepwise increases of PEEP achieving 45 cmH(2)O and peak pressure of 60 cmH2O, followed by ventilation with optimal PEEP titrated according to the static compliance of the respiratory system. In the control group, mechanical ventilation will follow a conventional protocol (ARDSNet). In both groups, we will use controlled volume mode with low tidal volumes (4 to 6 mL/kg of predicted body weight) and targeting plateau pressure <= 30 cmH2O. The primary outcome is 28-day survival, and the secondary outcomes are: length of ICU stay; length of hospital stay; pneumothorax requiring chest tube during first 7 days; barotrauma during first 7 days; mechanical ventilation-free days from days 1 to 28; ICU, in-hospital, and 6-month survival. ART is an event-guided trial planned to last until 520 events (deaths within 28 days) are observed. These events allow detection of a hazard ratio of 0.75, with 90% power and two-tailed type I error of 5%. All analysis will follow the intention-to-treat principle. Discussion: If the ART strategy with maximum recruitment and PEEP titration improves 28-day survival, this will represent a notable advance to the care of ARDS patients. Conversely, if the ART strategy is similar or inferior to the current evidence-based strategy (ARDSNet), this should also change current practice as many institutions routinely employ recruitment maneuvers and set PEEP levels according to some titration method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Common goals in epidemiologic studies of infectious diseases include identification of the infectious agent, description of the modes of transmission and characterization of factors that influence the probability of transmission from infected to uninfected individuals. In the case of AIDS, the agent has been identified as the Human Immunodeficiency Virus (HIV), and transmission is known to occur through a variety of contact mechanisms including unprotected sexual intercourse, transfusion of infected blood products and sharing of needles in intravenous drug use. Relatively little is known about the probability of IV transmission associated with the various modes of contact, or the role that other cofactors play in promoting or suppressing transmission. Here, transmission probability refers to the probability that the virus is transmitted to a susceptible individual following exposure consisting of a series of potentially infectious contacts. The infectivity of HIV for a given route of transmission is defined to be the per contact probability of infection. Knowledge of infectivity and its relationship to other factors is important in understanding the dynamics of the AIDS epidemic and in suggesting appropriate measures to control its spread. The primary source of empirical data about infectivity comes from sexual partners of infected individuals. Partner studies consist of a series of such partnerships, usually heterosexual and monogamous, each composed of an initially infected "index case" and a partner who may or may not be infected by the time of data collection. However, because the infection times of both partners may be unknown and the history of contacts uncertain, any quantitative characterization of infectivity is extremely difficult. Thus, most statistical analyses of partner study data involve the simplifying assumption that infectivity is a constant common to all partnerships. The major objectives of this work are to describe and discuss the design and analysis of partner studies, providing a general statistical framework for investigations of infectivity and risk factors for HIV transmission. The development is largely based on three papers: Jewell and Shiboski (1990), Kim and Lagakos (1990), and Shiboski and Jewell (1992).