996 resultados para 321402 Biomechanics


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In absence of basic canine hip biomechanics, a specific, consequent three dimensional concept to evaluate the coxofemoral joint was developed for the dog. With the help of a new method to radiologically demonstrate the hip in a physiological standing position several new clinically relevant aspects could be further investigated. For example the breed specific anatomical differences in the hip, and dynamics and the background on "iatrogenic luxations" in HD diagnostics could be shown. The caudal luxation and the growth abnormalities of the hip and their consequences on the whole leg (antetorsion syndrome) as a consequence of inadequate breeding could be demonstrated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In attempts to elucidate the underlying mechanisms of spinal injuries and spinal deformities, several experimental and numerical studies have been conducted to understand the biomechanical behavior of the spine. However, numerical biomechanical studies suffer from uncertainties associated with hard- and soft-tissue anatomies. Currently, these parameters are identified manually on each mesh model prior to simulations. The determination of soft connective tissues on finite element meshes can be a tedious procedure, which limits the number of models used in the numerical studies to a few instances. In order to address these limitations, an image-based method for automatic morphing of soft connective tissues has been proposed. Results showed that the proposed method is capable to accurately determine the spatial locations of predetermined bony landmarks. The present method can be used to automatically generate patient-specific models, which may be helpful in designing studies involving a large number of instances and to understand the mechanical behavior of biomechanical structures across a given population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Finite element (FE) analysis is an important computational tool in biomechanics. However, its adoption into clinical practice has been hampered by its computational complexity and required high technical competences for clinicians. In this paper we propose a supervised learning approach to predict the outcome of the FE analysis. We demonstrate our approach on clinical CT and X-ray femur images for FE predictions ( FEP), with features extracted, respectively, from a statistical shape model and from 2D-based morphometric and density information. Using leave-one-out experiments and sensitivity analysis, comprising a database of 89 clinical cases, our method is capable of predicting the distribution of stress values for a walking loading condition with an average correlation coefficient of 0.984 and 0.976, for CT and X-ray images, respectively. These findings suggest that supervised learning approaches have the potential to leverage the clinical integration of mechanical simulations for the treatment of musculoskeletal conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rebound-associated vertebral fractures may follow treatment discontinuation of highly potent reversible bone antiresorptives, resulting from the synergy of rapid bone resorption and accelerated microdamage accumulation in trabecular bone. INTRODUCTION The purposes of this study are to characterize rebound-associated vertebral fractures following the discontinuation of a highly potent reversible antiresorptive therapy based on clinical observation and propose a pathophysiological rationale. METHODS This study is a case report of multiple vertebral fractures early after discontinuation of denosumab therapy in a patient with hormone receptor-positive non-metastatic breast cancer treated with an aromatase inhibitor. RESULTS Discontinuation of highly potent reversible bone antiresorptives such as denosumab may expose patients to an increased fracture risk due to the joined effects of absent microdamage repair during therapy followed by synchronous excess activation of multiple bone remodelling units at the time of loss-of-effect. We suggest the term rebound-associated vertebral fractures (RVF) for this phenomenon characterized by the presence of multiple new clinical vertebral fractures, associated with either no or low trauma, in a context consistent with the presence of high bone turnover and rapid loss of lumbar spine bone mineral density (BMD) occurring within 3 to 12 months after discontinuation (loss-of-effect) of a reversible antiresorptive therapy in the absence of secondary causes of bone loss or fractures. Unlike atypical femoral fractures that emerge from failure of microdamage repair in cortical bone with long-term antiresorptive treatment, RVF originate from the synergy of rapid bone resorption and accelerated microdamage accumulation in trabecular bone triggered by the discontinuation of highly potent reversible antiresorptives. CONCLUSIONS Studies are urgently needed to i) prove the underlying pathophysiological processes suggested above, ii) establish the predictive criteria exposing patients to an increased risk of RVF, and iii) determine appropriate treatment regimens to be applied in such patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Keel fractures in the laying hen are the most critical animal welfare issue facing the egg production industry, particularly with the increased use of extensive systems in response to the 2012 EU directive banning conventional battery cages. The current study is aimed at assessing the effects of 2 omega-3 (n3) enhanced diets on bone health, production endpoints, and behavior in free-range laying hens. Data was collected from 2 experiments over 2 laying cycles, each of which compared a (n3) supplemented diet with a control diet. Experiment 1 employed a diet supplemented with a 60:40 fish oil-linseed mixture (n3:n6 to 1.35) compared with a control diet (n3:n6 to 0.11), whereas the n3 diet in Experiment 2 was supplemented with a 40:60 fish oil-linseed (n3:n6 to 0.77) compared to the control diet (n3:n6 to 0.11). The n3 enhanced diet of Experiment 1 had a higher n3:n6 ratio, and a greater proportion of n3 in the long chain (C20/22) form (0.41 LC:SC) than that of Experiment 2 (0.12 LC:SC). Although dietary treatment was successful in reducing the frequency of fractures by approximately 27% in Experiment 2, data from Experiment 1 indicated the diet actually induced a greater likelihood of fracture (odds ratio: 1.2) and had substantial production detriment. Reduced keel breakage during Experiment 2 could be related to changes in bone health as n3-supplemented birds demonstrated greater load at failure of the keel, and tibiae and humeri that were more flexible. These results support previous findings that n3-supplemented diets can reduce fracture likely by increasing bone strength, and that this can be achieved without detriment to production. However, our findings suggest diets with excessive quantities of n3, or very high levels of C20/22, may experience health and production detriments. Further research is needed to optimize the quantity and type of n3 in terms of bone health and production variables and investigate the potential associated mechanisms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The penalty corner is one of the most important game situations in field hockey with one third of all goals resulting from this tactical situation. The aim of this study was to develop and apply a training method, based on previous studies, to improve the drag- flick skill on a young top-class field hockey player. A young top-class player exercised three times per week using specific drills over a four week period. A VICON optoelectronic system (Oxford Metrics, Oxford, UK) was employed to capture twenty drag-flicks, with six cameras sampling at 250 Hz, prior and after the training period. In order to analyze pre- and post-test differences a dependent t-test was carried out. Angular velocities and the kinematic sequence were similar to previous studies. The player improved (albeit not significantly) the angular velocity of the stick. The player increased front foot to the ball at T1 (p < 0.01) and the drag-flick distances. The range of motion from the front leg decreased from T1 to T6 after the training period (p < 0.01). The specific training sessions conducted with the player improved some features of this particular skill. This article shows how technical knowledge can help with the design of training programs and whether some drills are more effective than others.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the design of a bat-like micro aerial vehicle with actuated morphing wings. NiTi shape memory alloys (SMAs) acting as artificial biceps and triceps muscles are used for mimicking the morphing wing mechanism of the bat flight apparatus. Our objective is twofold. Firstly, we have implemented a control architecture that allows an accurate and fast SMA actuation. This control makes use of the electrical resistance measurements of SMAs to adjust morphing wing motions. Secondly, the feasibility of using SMA actuation technology is evaluated for the application at hand. To this purpose, experiments are conducted to analyze the control performance in terms of nominal and overloaded operation modes of the SMAs. This analysis includes: (i) inertial forces regarding the stretchable wing membrane and aerodynamic loads, and (ii) uncertainties due to impact of airflow conditions over the resistance–motion relationship of SMAs. With the proposed control, morphing actuation speed can be increased up to 2.5 Hz, being sufficient to generate lift forces at a cruising speed of 5ms−1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neurological Diseases (ND) are affecting larger segments of aging population every year. Treatment is dependent on expensive accurate and frequent monitoring. It is well known that ND leave correlates in speech and phonation. The present work shows a method to detect alterations in vocal fold tension during phonation. These may appear either as hypertension or as cyclical tremor. Estimations of tremor may be produced by auto-regressive modeling of the vocal fold tension series in sustained phonation. The correlates obtained are a set of cyclicality coefficients, the frequency and the root mean square amplitude of the tremor. Statistical distributions of these correlates obtained from a set of male and female subjects are presented. Results from five study cases of female voice are also given.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hymenoptera attach to smooth surfaces with a flexible pad, the arolium, between the claws. Here we investigate its movement in Asian weaver ants (Oecophylla smaragdina) and honeybees (Apis mellifera).  When ants run upside down on a smooth surface, the arolium is unfolded and folded back with each step. Its extension is strictly coupled with the retraction of the claws. Experimental pull on the claw-flexor tendon revealed that the claw-flexor muscle not only retracts the claws, but also moves the arolium. The elicited arolium movement comprises (i) about a 90° rotation (extension) mediated by the interaction of the two rigid pretarsal sclerites arcus and manubrium and (ii) a lateral expansion and increase in volume. In severed legs of O. smaragdina ants, an increase in hemolymph pressure of 15 kPa was sufficient to inflate the arolium to its full size. Apart from being actively extended, an arolium in contact also can unfold passively when the leg is subject to a pull toward the body.  We propose a combined mechanical–hydraulic model for arolium movement: (i) the arolium is engaged by the action of the unguitractor, which mechanically extends the arolium; (ii) compression of the arolium gland reservoir pumps liquid into the arolium; (iii) arolia partly in contact with the surface are unfolded passively when the legs are pulled toward the body; and (iv) the arolium deflates and moves back to its default position by elastic recoil of the cuticle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interest in corneal biomechanics has increased with the development of new refractive surgery techniques aimed at modifying corneal properties and a variety of surgical options for corneal ectasia management. The human cornea behaves as soft biological material. It is a viscoelastic tissue and its response to a force applied to it depends not only on the magnitude of the force, but also on the velocity of the application. There are concerns about the limitations to measuring corneal biomechanical properties in vivo. To date, 2 systems are available for clinical use: the Ocular Response Analyzer, a dynamic bidirectional applanation device, and the Corvis ST, a dynamic Scheimpflug analyzer device. These devices are useful in clinical practice, especially for planning some surgical procedures and earlier detection of ectatic conditions, but further research is needed to connect the clinical measurements obtained with these devices to the standard mechanical properties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biomechanics is often defined as ‘mechanics applied to biology’. Due to the variety and complexity of the behaviour of biological structures and materials, biomechanics is better defined as the development, extension and application of mechanics for a better understanding of physiology and physiopathology and consequently for a better diagnosis and treatment of disease and injury. Different methods for the characterisation of corneal biomechanics are reviewed in detail, including those that are currently commercially available (Ocular Response Analyzer and CorVis ST). The clinical applicability of the parameters provided by these devices are discussed, especially in the fields of glaucoma, detection of ectatic disorders and orthokeratology. Likewise, other methods are also reviewed, such as Brillouin microscopy or dynamic optical coherence tomography and others with potential application to clinical practice but not validated for in vivo measurements, such as ultrasonic elastography. Advantages and disadvantages of all these techniques are described. Finally, the concept of biomechanical modelling is revised as well as the requirements for developing biomechanical models, with special emphasis on finite element modelling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the possible associations between corneal biomechanical parameters, optic disc morphology, and retinal nerve fiber layer (RNFL) thickness in healthy white Spanish children. Methods: This cross-sectional study included 100 myopic children and 99 emmetropic children as a control group, ranging in age from 6 to 17 years. The Ocular Response Analyzer was used to measure corneal hysteresis (CH) and corneal resistance factor. The optic disc morphology and RNFL thickness were assessed using posterior segment optical coherence tomography (Cirrus HD-OCT). The axial length was measured using an IOLMaster, whereas the central corneal thickness was measured by anterior segment optical coherence tomography (Visante OCT). Results: The mean (±SD) age and spherical equivalent were 12.11 (±2.76) years and −3.32 (±2.32) diopters for the myopic group and 11.88 (±2.97) years and +0.34 (±0.41) diopters for the emmetropic group. In a multivariable mixed-model analysis in myopic children, the average RNFL thickness and rim area correlated positively with CH (p = 0.007 and p = 0.001, respectively), whereas the average cup-to-disc area ratio correlated negatively with CH (p = 0.01). We did not observe correlation between RNFL thickness and axial length (p = 0.05). Corneal resistance factor was only positively correlated with the rim area (p = 0.001). The central corneal thickness did not correlate with the optic nerve parameters or with RNFL thickness. These associations were not found in the emmetropic group (p > 0.05 for all). Conclusions: The corneal biomechanics characterized with the Ocular Response Analyzer system are correlated with the optic disc profile and RNFL thickness in myopic children. Low CH values may indicate a reduction in the viscous dampening properties of the cornea and the sclera, especially in myopic children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the relationship between different ocular and corneal biomechanical parameters in emmetropic and ametropic healthy white children. Methods: This study included 293 eyes of 293 healthy Spanish children (135 boys and 158 girls), ranging in age from 6 to 17 years. Subjects were divided according to the refractive error: control (emmetropia, 99 children), myopia (100 children), and hyperopia (94 children) groups. In all cases, corneal hysteresis (CH) and corneal resistance factor (CRF) were evaluated with the Ocular Response Analyzer system. Axial length (AL) and mean corneal power were also measured by partial coherence interferometry (IOLMaster), and central corneal thickness (CCT) and anterior chamber depth were measured by anterior segment optical coherence tomography (Visante). Results: Mean (±SD) CH and CRF were 12.12 (±1.71) and 12.30 (±1.89) mm Hg, respectively. Mean (±SD) CCT was 542.68 (±37.20) μm and mean (±SD) spherical equivalent was +0.14 (±3.41) diopters. A positive correlation was found between CH and CRF (p < 0.001), and both correlated as well with CCT (p < 0.0001). Corneal resistance factor was found to decrease with increasing age (p = 0.01). Lower levels of CH were associated with longer AL and more myopia (p < 0.001 and p = 0.001, respectively). Higher values of CH were associated with increasing hyperopia. Significant differences in CH were found between emmetropic and myopic groups (p < 0.001) and between myopic and hyperopic groups (p = 0.011). There were also significant differences in CRF between emmetropic and myopic groups (p = 0.02). Multiple linear regression analysis showed that lower CH and CRF significantly associated with thinner CCT, longer AL, and flatter corneal curvature. Conclusions: The Ocular Response Analyzer corneal biomechanical properties seem to be compromised in myopia from an early age, especially in high myopia.