938 resultados para 3-dimensional ultrasonography


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To estimate the response in lung growth and vascularity after fetal endoscopic tracheal occlusion for severe congenital diaphragmatic hernia in the prediction of neonatal survival. METHODS: Between January 2006 and December 2010, fetal lung parameters (observed-to-expected lung-to-head ratio; observed-to-expected lung volume; and contralateral lung vascularization index) were evaluated before fetal tracheal occlusion and were evaluated longitudinally every 2 weeks in 72 fetuses with severe isolated congenital diaphragmatic hernia. Thirty-five fetuses underwent fetal endoscopic tracheal occlusion and 37 cases did not. RESULTS: Survival rate was significantly higher in the fetal endoscopic tracheal occlusion group (54.3%) than in the no fetal endoscopic tracheal occlusion group (5.4%, P<.01). Fetal endoscopic tracheal occlusion resulted in a significant improvement in fetal lung size and pulmonary vascularity when compared with fetuses that did not go to the fetal intervention (increase of the observed-to-expected lung-to-head ratio, observed-to-expected total lung volume, and contralateral pulmonary vascularization index 56.2% compared with 0.3%, 37.9% compared with 0.1%, and 98.6% compared with 0.0%, respectively; P<.01). Receiver operating characteristic curves indicated that the observed-to-expected total fetal lung volume was the single best predictor of neonatal survival before fetal endoscopic tracheal occlusion (cutoff 0.23, area under the curve [AUC] 0.88, relative risk 5.3, 95% confidence interval [CI] 1.4-19.7). However, the contralateral lung vascularization index at 4 weeks after fetal endoscopic tracheal occlusion was more accurate in the prediction of neonatal outcome (cutoff 24.0%, AUC 0.98, relative risk 9.9, 95% CI 1.5-66.9) with the combination of observed-to-expected lung volumes and contralateral lung vascularization index at 4 weeks being the best predictor of outcome (AUC 0.98, relative risk 16.6, 95% CI 2.5-112.3). CONCLUSION: Fetal endoscopic tracheal occlusion improves survival rate by increasing the lung size and pulmonary vascularity in fetuses with severe congenital diaphragmatic hernia. The pulmonary response after fetal endoscopic tracheal occlusion can be used to predict neonatal survival. (Obstet Gynecol 2012; 119: 93-101) DOI: 10.1097/AOG.0b013e31823d3aea

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives To evaluate the accuracy and probabilities of different fetal ultrasound parameters to predict neonatal outcome in isolated congenital diaphragmatic hernia (CDH). Methods Between January 2004 and December 2010, we evaluated prospectively 108 fetuses with isolated CDH (82 left-sided and 26 right-sided). The following parameters were evaluated: gestational age at diagnosis, side of the diaphragmatic defect, presence of polyhydramnios, presence of liver herniated into the fetal thorax (liver-up), lung-to-head ratio (LHR) and observed/expected LHR (o/e-LHR), observed/expected contralateral and total fetal lung volume (o/e-ContFLV and o/e-TotFLV) ratios, ultrasonographic fetal lung volume/fetal weight ratio (US-FLW), observed/expected contralateral and main pulmonary artery diameter (o/e-ContPA and o/eMPA) ratios and the contralateral vascularization index (Cont-VI). The outcomes were neonatal death and severe postnatal pulmonary arterial hypertension (PAH). Results Neonatal mortality was 64.8% (70/108). Severe PAH was diagnosed in 68 (63.0%) cases, of which 63 died neonatally (92.6%) (P < 0.001). Gestational age at diagnosis, side of the defect and polyhydramnios were not associated with poor outcome (P > 0.05). LHR, o/eLHR, liver-up, o/e-ContFLV, o/e-TotFLV, US-FLW, o/eContPA, o/e-MPA and Cont-VI were associated with both neonatal death and severe postnatal PAH (P < 0.001). Receiver-operating characteristics curves indicated that measuring total lung volumes (o/e-TotFLV and US-FLW) was more accurate than was considering only the contralateral lung sizes (LHR, o/e-LHR and o/e-ContFLV; P < 0.05), and Cont-VI was the most accurate ultrasound parameter to predict neonatal death and severe PAH (P < 0.001). Conclusions Evaluating total lung volumes is more accurate than is measuring only the contralateral lung size. Evaluating pulmonary vascularization (Cont-VI) is the most accurate predictor of neonatal outcome. Estimating the probability of survival and severe PAH allows classification of cases according to prognosis. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To compare the agreement of multiplanar and rendering modes in the assessment fetal atrioventricular valves (mitral and tricuspid) areas by three-dimensional (3D) ultrasonography using the software spatio-temporal image correlation (STIC). Methods: We conducted a prospective cross-sectional study with normal pregnant women, with single fetuses, between 18-33 weeks. To measure the areas, we used the plan of four-chamber view. In the case of multiplanar, the plane was rotated on the axis "Z" form the heart to position at 9h. For rendering, the green line (region of interest - ROI) was placed from the atria of the heart perpendicular to the crux. The agreement was assessed by a Bland-Altman (limits of agreement) using the relative difference between the measures: ((rendering mode) - (multiplanar mode)) / (average). Results: 328 fetuses were evaluated. We have not identified the occurrence of systematic error between methods: the average relative difference was 1.62% (-2.07% to 5.32%, confidence interval 95%) in the mitral and 1.77% (- 1.08% to 4.62%) in the tricuspid valve. The limits of agreement between methods were -65.26% to 68.51% for the mitral and -49.91% to 53.45% for the tricuspid. Conclusions: There was no systematic error between modes and thus the observed values for the area of fetal atrioventricular valves can be used for comparisons needs to be corrected. However, relatively large variations may be observed when repeating the measurement area by different modes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Cartilage defects are common pathologies and surgical cartilage repair shows promising results. In its postoperative evaluation, the magnetic resonance observation of cartilage repair tissue (MOCART) score, using different variables to describe the constitution of the cartilage repair tissue and the surrounding structures, is widely used. High-field magnetic resonance imaging (MRI) and 3-dimensional (3D) isotropic sequences may combine ideal preconditions to enhance the diagnostic performance of cartilage imaging.Aim of this study was to introduce an improved 3D MOCART score using the possibilities of an isotropic 3D true fast imaging with steady-state precession (True-FISP) sequence in the postoperative evaluation of patients after matrix-associated autologous chondrocyte transplantation (MACT) as well as to compare the results to the conventional 2D MOCART score using standard MR sequences. MATERIAL AND METHODS: The study had approval by the local ethics commission. One hundred consecutive MR scans in 60 patients at standard follow-up intervals of 1, 3, 6, 12, 24, and 60 months after MACT of the knee joint were prospectively included. The mean follow-up interval of this cross-sectional evaluation was 21.4 +/- 20.6 months; the mean age of the patients was 35.8 +/- 9.4 years. MRI was performed at a 3.0 Tesla unit. All variables of the standard 2D MOCART score where part of the new 3D MOCART score. Furthermore, additional variables and options were included with the aims to use the capabilities of isotropic MRI, to include the results of recent studies, and to adapt to the needs of patients and physician in a clinical routine examination. A proton-density turbo spin-echo sequence, a T2-weighted dual fast spin-echo (dual-FSE) sequence, and a T1-weighted turbo inversion recovery magnitude (TIRM) sequence were used to assess the standard 2D MOCART score; an isotropic 3D-TrueFISP sequence was prepared to evaluate the new 3D MOCART score. All 9 variables of the 2D MOCART score were compared with the corresponding variables obtained by the 3D MOCART score using the Pearson correlation coefficient; additionally the subjective quality and possible artifacts of the MR sequences were analyzed. RESULTS: The correlation between the standard 2D MOCART score and the new 3D MOCART showed for the 8 variables "defect fill," "cartilage interface," "surface," "adhesions," "structure," "signal intensity," "subchondral lamina," and "effusion"-a highly significant (P < 0.001) correlation with a Pearson coefficient between 0.566 and 0.932. The variable "bone marrow edema" correlated significantly (P < 0.05; Pearson coefficient: 0.257). The subjective quality of the 3 standard MR sequences was comparable to the isotropic 3D-TrueFISP sequence. Artifacts were more frequently visible within the 3D-TrueFISP sequence. CONCLUSION: In the clinical routine follow-up after cartilage repair, the 3D MOCART score, assessed by only 1 high-resolution isotropic MR sequence, provides comparable information than the standard 2D MOCART score. Hence, the new 3D MOCART score has the potential to combine the information of the standard 2D MOCART score with the possible advantages of isotropic 3D MRI at high-field. A clear limitation of the 3D-TrueFISP sequence was the high number of artifacts. Future studies have to prove the clinical benefits of a 3D MOCART score.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

It has previously been found that complexes comprised of vitronectin and growth factors (VN:GF) enhance keratinocyte protein synthesis and migration. More specifically, these complexes have been shown to significantly enhance the migration of dermal keratinocytes derived from human skin. In view of this, it was thought that these complexes may hold potential as a novel therapy for healing chronic wounds. However, there was no evidence indicating that the VN:GF complexes would retain their effect on keratinocytes in the presence of chronic wound fluid. The studies in this thesis demonstrate for the first time that the VN:GF complexes not only stimulate proliferation and migration of keratinocytes, but also these effects are maintained in the presence of chronic wound fluid in a 2-dimensional (2-D) cell culture model. Whilst the 2-D culture system provided insights into how the cells might respond to the VN:GF complexes, this investigative approach is not ideal as skin is a 3-dimensional (3-D) tissue. In view of this, a 3-D human skin equivalent (HSE) model, which reflects more closely the in vivo environment, was used to test the VN:GF complexes on epidermopoiesis. These studies revealed that the VN:GF complexes enable keratinocytes to migrate, proliferate and differentiate on a de-epidermalised dermis (DED), ultimately forming a fully stratified epidermis. In addition, fibroblasts were seeded on DED and shown to migrate into the DED in the presence of the VN:GF complexes and hyaluronic acid, another important biological factor in the wound healing cascade. This HSE model was then further developed to enable studies examining the potential of the VN:GF complexes in epidermal wound healing. Specifically, a reproducible partial-thickness HSE wound model was created in fully-defined media and monitored as it healed. In this situation, the VN:GF complexes were shown to significantly enhance keratinocyte migration and proliferation, as well as differentiation. This model was also subsequently utilized to assess the wound healing potential of a synthetic fibrin-like gel that had previously been demonstrated to bind growth factors. Of note, keratinocyte re-epitheliasation was shown to be markedly improved in the presence of this 3-D matrix, highlighting its future potential for use as a delivery vehicle for the VN:GF complexes. Furthermore, this synthetic fibrin-like gel was injected into a 4 mm diameter full-thickness wound created in the HSE, both keratinocytes and fibroblasts were shown to migrate into this gel, as revealed by immunofluorescence. Interestingly, keratinocyte migration into this matrix was found to be dependent upon the presence of the fibroblasts. Taken together, these data indicate that reproducible wounds, as created in the HSEs, provide a relevant ex vivo tool to assess potential wound healing therapies. Moreover, the models will decrease our reliance on animals for scientific experimentation. Additionally, it is clear that these models will significantly assist in the development of novel treatments, such as the VN:GF complexes and the synthetic fibrin-like gel described herein, ultimately facilitating their clinical trial in the treatment of chronic wounds.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: To determine i) the reliability of two-dimensional ultrasonography for the assessment of biceps femoris long head (BFlh) architectural characteristics; ii) if limbs with a history of strain injury in the BFlh display different architecture and eccentric strength compared to uninjured limbs. Methods: This case-control study (control [n=20], injured group [n=16], males) assessed the BFlh architecture at rest and during graded isometric contractions using two-dimensional ultrasonography. The control group were assessed three times (>24hrs apart) to determine reliability. Previously injured individuals were evaluated once. Results The assessment of BFlh architecture was highly reliable (intraclass correlations >0.90). Fascicle length (p<0.001; d range: 0.67 to 1.34) and fascicle length relative to muscle thickness (p<0.001; d range: 0.58 to 0.85) of the previously injured BFlh were significantly less than the contralateral uninjured BFlh at all intensities. Pennation angle of the previously injured BFlh was significantly greater (p<0.001; d range: 0.62 to 0.88) than the contralateral uninjured BFlh at all intensities. Eccentric strength in the previously injured limb was significantly lower than the contralateral limb (-15.4%; -52.5N; 95% CI=-28.45 to -76.23; p<0.001, d=0.56). Conclusion These data indicate that two-dimensional ultrasonography is reliable for assessing BFlh architecture at rest and during graded isometric contractions. Fascicle length, fascicle length relative to muscle thickness and pennation angle are significantly different in previously injured BFlh compared to an uninjured contralateral BFlh. Eccentric strength of the previously injured limb is also significantly lower than the uninjured contralateral limb. These findings have implications for rehabilitation and injury prevention practices which should consider altered architectural characteristics.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: To determine the extent to which the accuracy of magnetic resonance imaging (MRI) based virtual 3-dimensional (3D) models of the intact orbit can approach that of the gold standard, computed tomography (CT) based models. The goal was to determine whether MRI is a viable alternative to CT scans in patients with isolated orbital fractures and penetrating eye injuries, pediatric patients, and patients requiring multiple scans in whom radiation exposure is ideally limited. Materials and Methods: Patients who presented with unilateral orbital fractures to the Royal Brisbane and Women’s Hospital from March 2011 to March 2012 were recruited to participate in this cross-sectional study. The primary predictor variable was the imaging technique (MRI vs CT). The outcome measurements were orbital volume (primary outcome) and geometric intraorbital surface deviations (secondary outcome)between the MRI- and CT-based 3D models. Results: Eleven subjects (9 male) were enrolled. The patients’ mean age was 30 years. On average, the MRI models underestimated the orbital volume of the CT models by 0.50 0.19 cm3 . The average intraorbital surface deviation between the MRI and CT models was 0.34 0.32 mm, with 78 2.7% of the surface within a tolerance of 0.5 mm. Conclusions: The volumetric differences of the MRI models are comparable to reported results from CT models. The intraorbital MRI surface deviations are smaller than the accepted tolerance for orbital surgical reconstructions. Therefore, the authors believe that MRI is an accurate radiation-free alternative to CT for the primary imaging and 3D reconstruction of the bony orbit. �

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose To determine i) the architectural adaptations of the biceps femoris long head (BFlf) following concentric or eccentric strength training interventions; ii) the time course of adaptation during training and detraining. Methods Participants in this randomized controlled trial (control [n=28], concentric training group [n=14], eccentric training group [n=14], males) completed a 4-week control period, followed by 6 weeks of either concentric- or eccentric-only knee flexor training on an isokinetic dynamometer and finished with 28 days of detraining. Architectural characteristics of BFlf were assessed at rest and during graded isometric contractions utilizing two-dimensional ultrasonography at 28 days pre-baseline, baseline, days 14, 21 and 42 of the intervention and then again following 28 days of detraining. Results BFlf fascicle length was significantly longer in the eccentric training group (p<0.05, d range: 2.65 to 2.98) and shorter in the concentric training group (p<0.05, d range: -1.62 to -0.96) after 42 days of training compared to baseline at all isometric contraction intensities. Following the 28-day detraining period, BFlf fascicle length was significantly reduced in the eccentric training group at all contraction intensities compared to the end of the intervention (p<0.05, d range: -1.73 to -1.55). There was no significant change in fascicle length of the concentric training group following the detraining period. Conclusions These results provide evidence that short term resistance training can lead to architectural alterations in the BFlf. In addition, the eccentric training-induced lengthening of BFlf fascicle length was reversed and returned to baseline values following 28 days of detraining. The contraction mode specific adaptations in this study may have implications for injury prevention and rehabilitation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose To determine if limbs with a history of anterior cruciate ligament (ACL) injury reconstructed from the semitendinosus (ST) display different biceps femoris long head (BFlh) architecture and eccentric strength, assessed during the Nordic hamstring exercise, compared to the contralateral uninjured limb. Methods The architectural characteristics of the BFlh were assessed at rest and at 25% of a maximal voluntary isometric contraction (MVIC) in the control (n=52) and previous ACL injury group (n=15) using two-dimensional ultrasonography. Eccentric knee-flexor strength was assessed during the Nordic hamstring exercise. Results Fascicle length was shorter (p=0.001; d range: 0.90 to 1.31) and pennation angle (p range: 0.001 to 0.006: d range: 0.87 to 0.93) was greater in the BFlh of the ACL injured limb when compared to the contralateral uninjured limb at rest and during 25% of MVIC. Eccentric strength was significantly lower in the ACL injured limb than the contralateral uninjured limb (-13.7%; -42.9N; 95% CI = -78.7 to -7.2; p=0.021; d=0.51). Fascicle length, MVIC and eccentric strength were not different between the left and right limb in the control group. Conclusions Limbs with a history of ACL injury reconstructed from the ST have shorter fascicles and greater pennation angles in the BFlh compared to the contralateral uninjured side. Eccentric strength during the Nordic hamstring exercise of the ACL injured limb is significantly lower than the contralateral side. These findings have implications for ACL rehabilitation and hamstring injury prevention practices which should consider altered architectural characteristics.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background Aneurysm expansion rate is an important indicator of the potential risk of abdominal aortic aneurysm (AAA) rupture. Stress within the AAA wall is also thought to be a trigger for its rupture. However, the association between aneurysm wall stresses and expansion of AAA is unclear. Methods and Results Forty-four patients with AAAs were included in this longitudinal follow-up study. They were assessed by serial abdominal ultrasonography and computed tomography scans if a critical size was reached or a rapid expansion occurred. Patient-specific 3-dimensional AAA geometries were reconstructed from the follow-up computed tomography images. Structural analysis was performed to calculate the wall stresses of the AAA models at both baseline and final visit. A nonlinear large-strain finite element method was used to compute the wall-stress distribution. The relationship between wall stresses and expansion rate was investigated. Slowly and rapidly expanding aneurysms had comparable baseline maximum diameters (median, 4.35 cm [interquartile range, 4.12 to 5.0 cm] versus 4.6 cm [interquartile range, 4.2 to 5.0 cm]; P=0.32). Rapidly expanding AAAs had significantly higher shoulder stresses than slowly expanding AAAs (median, 300 kPa [interquartile range, 280 to 320 kPa] versus 225 kPa [interquartile range, 211 to 249 kPa]; P=0.0001). A good correlation between shoulder stress at baseline and expansion rate was found (r=0.71; P=0.0001). Conclusion A higher shoulder stress was found to have an association with a rapidly expanding AAA. Therefore, it may be useful for estimating the expansion of AAAs and improve risk stratification of patients with AAAs.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Growth rate of abdominal aortic aneurysm (AAA) is thought to be an important indicator of the potential risk of rupture. Wall stress is also thought to be a trigger for its rupture. However, stress change during the expansion of an AAA is unclear. Forty-four patients with AAAs were included in this longitudinal follow-up study. They were assessed by serial abdominal ultrasonography and computerized tomography (CT) scans if a critical size was reached or a rapid expansion occurred. Patient-specific 3-dimensional AAA geometries were reconstructed from the follow-up CT images. Structural analysis was performed to calculate the wall stresses of the AAA models at both baseline and final visit. A non-linear large-strain finite element method was used to compute the wall stress distribution. The average growth rate was 0.66cm/year (range 0-1.32 cm/year). A significantly positive correlation between shoulder tress at baseline and growth rate was found (r=0.342; p=0.02). A higher shoulder stress is associated with a rapidly expanding AAA. Therefore, it may be useful for estimating the growth expansion of AAAs and further risk stratification of patients with AAAs.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

All the second-order boundary-layer effects have been studied for the steady laminar compressible 3-dimensional stagnation-point flows with variable properties and mass transfer for both saddle and nodal point regions. The governing equations have been solved numerically using an implicit finite-difference scheme. Results for the heat transfer and skin friction have been obtained for several values of the mass-transfer rate, wall temperature, and also for several values of parameters characterizing the nature of stagnation point and variable gas properties. The second-order effects on the heat transfer and skin friction at the wall are found to be significant and at large injection rates, they dominate over the results of the first-order boundary layer, but the effect of large suction is just the opposite. In general, the second-order effects are more pronounced in the saddle-point region than in the nodal-point region. The overall heat-transfer rate for the 3-dimensional flows is found to be more than that of the 2-dimensional flows.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Electrical and magnetic properties of La3Ni2O7 and La4Ni3O10 have been investigated in comparison with those of La2NiO4, LaNiO3, and LaSrNiO4. The results suggest an increasing 3-dimensional character across the homologous series Lan+1NinO3n+1 with increase in n. Accordingly, the electrical resistivity decreases in the order La3Ni2O7, La4Ni3O10, and LaNiO3 and this trend is suggested to be related to the percolation threshold. Magnetic properties of these oxides also show some interesting trends across the series.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A method of analysing a 3-dimensional corner reflector antenna of arbitrary apex angle is given. Expressions have been obtained for the far field of the 3-dimensional corner reflector fed by a dipole. The radiation resistance and the directive gain of the antenna have been calculated. The method described is applicable even when the feed dipole is arbitrarily oriented. It is found that the radiation along a prescribed direction can be circularly polarised (right or left) by suitably orienting the feed dipole.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A method of analysing a 3-dimensional corner reflector antenna of arbitrary apex angle is given. Expressions have been obtained for the far field of the 3-dimensional corner reflector fed by a dipole. The radiation resistance and the directive gain of the antenna have been calculated. The method described is applicable even when the feed dipole is arbitrarily oriented. It is found that the radiation along a prescribed direction can be circularly polarised (right or left) by suitably orienting the feed dipole.