983 resultados para “Horizontal ridge augmentation” AND “dental implants”
Resumo:
Purpose: This study compared the biomechanical behavior of tilted long implant and vertical short implants to support fixed prosthesis in an atrophic maxilla. Materials and Methods: The maxilla model was built based on a tomographic image of the patient. Implant models were based on micro-computer tomography imaging of implants. The different configurations considered were M4S, four vertical anterior implants; M4T, two mesial vertical implants and two distal tilted (45°) implants in the anterior region of the maxilla; and M6S, four vertical anterior implants and two vertical posterior implants. Numerical simulation was carried out under bilateral 150N loads applied in the cantilever region in axial (L1) and oblique (45°) (L2) direction. Bone was analyzed using the maximum and minimum principal stress (σmax and σmin), and von Mises stress (σvM) assessments. Implants were analyzed using the σvM. Results: The higher σmax was observed at: M4T, followed by M6S/L1, M6S/L2, M4S/L2, and M4S/L1 and the higher σvM: M4T/L1, M4T/L2 and M4S/L2, M6S/L2, M4S/L1, and M6S/L1. Conclusions: The presence of distal tilted (all-on-four) and distal short implants (all-on-six) resulted in higher stresses in both situations in the maxillary bone in comparison to the presence of vertical implants (all-on-four). © 2013 Wiley Periodicals, Inc.
Resumo:
Tribocorrosion plays an important role in the lifetime of metallic implants. Once implanted, biomaterials are subjected to micro-movements in aggressive biological fluids. Titanium is widely used as an implant material because it spontaneously forms a compact and protective nanometric thick oxide layer, mainly TiO2, in ambient air. That layer provides good corrosion resistance, and very low toxicity, but its low wear resistance is a concern. In this work, an anodizing treatment was performed on commercial pure titanium to form a homogeneous thick oxide surface layer in order to provide bioactivity and improve the biological, chemical and mechanical properties. Anodizing was performed in an electrolyte containing β-glycerophosphate and calcium acetate. The influence of the calcium acetate content on the tribocorrosion behaviour of the anodized material was studied. The concentration of calcium acetate in the electrolyte was found to largely affect the crystallographic structure of the resulting oxide layer. Better tribocorrosion behaviour was noticed on increasing the calcium acetate concentration. © 2013 IOP Publishing Ltd.
Stress analysis in oral obturator prostheses over parallel and tilted implants: photoelastic imaging
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Statement of problem. In dental rehabilitations that involve implants, the number of implants is sometimes smaller than the number of lost teeth. This fact can affect the biomechanical behavior and success of the implants.Purpose. The purpose of this study was to investigate the mechanical behavior of different implant positions in the rehabilitation of the anterior maxilla.Material and methods. Three-dimensional models of the maxilla were created based on computed tomography images for 3 different anterior prosthetic rehabilitations. In group IL, the implants were placed in the lateral incisor positions with pontics in the central incisor positions; in group IC, the implants were in the central incisor positions with cantilevers in the lateral incisor positions; and, in group ILIC, one implant was in a lateral incisor position and one was in a central incisor position, with a pontic and a cantilever in the remaining positions. A 150 N load was distributed and applied at the center of the palatal surface of each tooth at a 45-degree angle to the long axis of the tooth. The resulting stress-strain distribution was analyzed for each group.Results. The lowest displacement of the prosthetic structure was observed in group IC, although the same group exhibited the largest displacement of the bone tissue. In the bone tissue, the von Mises stress was mainly observed in the cortical bone in all groups. The maximum value of the von Mises stress shown in the cortical tissue was 35 MPa in the implant that neighbors the cantilever in group ILIC. The maximum von Mises stress in the trabecular bone was 3.5 MPa.Conclusion. The prosthetic configuration of group IC limited the displacement of the prosthetic structure but led to greater displacement of the bone structure. The use of a cantilever increased the stress concentration in the implant and in the bone structure adjacent to the cantilever under the conditions studied here.
Resumo:
Bone quality and quantity are important factors with regard to the survival rate of dental implants. The aim of this study was to conduct a systematic review of dental implants inserted in low-density bone and to determine the survival rate of dental implants with surface treatments over time. A systematic review of the literature was undertaken by two independent individuals; the Medline/PubMed database was searched for the period July 1975 to March 2013. Relevant reports on bone quality and osseointegration of dental implants were selected. The search retrieved 1018 references, and after inclusion and exclusion criteria were applied, 19 studies were selected for review. A total of 3937 patients, who had received a total of 12,465 dental implants, were analyzed. The survival rates of dental implants according to the bone density were: type I, 97.6%; type II, 96.2%; type III, 96.5%; and type IV, 88.8%. The survival rate of treated surface implants inserted in low-density bone was higher (97.1%) than that of machined surface implants (91.6%). Surface-treated dental implants inserted in low-density bone have a high survival rate and may be indicated for oral rehabilitation. However, more randomized studies are required to better evaluate this issue.
Resumo:
Introduction: In clinical situations where severe bone resorption has occurred following tooth loss, implant treatment options may comprise either a previous bone reconstruction or only the use of short implants. Objective: This non-systematic review summarizes and discusses some aspects of the use of short implants, such as: biomechanical aspects, success rate, longevity and surgical-prosthetic planning. Literature review: Current and relevant references were selected in order to compare short dental implants to conventional ones. Several studies have highlighted the great importance of wide-diameter implants. Dental short implants have shown high predictability and success rates when some biomechanical aspects are taken into consideration. Conclusion: Placement of short dental implants is a viable treatment method for patients with decreased bone height.
Resumo:
The aim of this study was to review the literature on the systems used to decontaminate the implant's surface. Different instruments have been proposed, but there is no agreement in the literature about which methods would be more efficient with no damage to the implant surface. It was reported the use of plastic, carbon fiber, stainless-steel and titanium curettes and also the use of other systems such as ultrasonic points with different tips, rubber cups and air abrasion. Literature review: In most of the studies, the injury caused on the titanium surface at the time of instrumentation was examined. In others, the cell adhesion on the titanium dental implants following instrumentation of the implant surface was observed. Moreover, to enhance cleaning around implants, ultrasonic systems were recently tested. Conclusion: Metal instruments can lead to major damage to implant surface, therefore, they are not indicated for decontamination of dental implants surfaces. Furthermore, non-metallic instruments, such as plastic curettes, rubber cups, air abrasion and some ultrasonic systems seem to be better choices to remove calculus and plaque of the sub- and supra-gingival peri-implant area. It is noteworthy that more studies evaluating the effects of these systems are required to establish best practices to be used in the treatment of patients with dental implants.
Resumo:
The aim of this systematic review was to identify clinical studies on implants placed in the tuberosity region to determine the survival rate of these implants when compared to implants placed in other regions of the maxilla. A search for data published up until March 2014 was undertaken using the PubMed, Cochrane Library, Embase, and ScienceDirect databases. Eligible studies were selected according to inclusion and exclusion criteria. The first database search revealed 310 titles. After inclusion and exclusion criteria were applied, five studies remained for the detailed analysis. A total of 113 patients were followed for a period of 6-144 months; 289 implants were placed in the patients evaluated. There were eight failures/losses of dental implants in the tuberosity region; the overall survival rate was 94.63% for these implants. In controlled studies, the cumulative survival rates for implants placed in the maxillary tuberosity and other maxillary regions were 96.1% and 95%, respectively. In conclusion, implants placed into the maxillary tuberosity are a predictable alternative for the treatment of patients with insufficient bone volume in the maxillary region. However, randomized trials are needed to assess the effectiveness of this treatment.
Resumo:
ObjectiveTo study the buccal dimensional tissue changes at oral implants following free gingival grafting, with or without including the keratin layer, performed at the time of implant installation into alveolar mucosa.Material and methodsThe mandibular premolars and first molars were extracted bilaterally in six Beagle dogs. In the right side of the mandible (Test), flaps were first elevated, and the buccal as well as part of the lingual masticatory mucosa was removed. An incision of the periosteum at the buccal aspect was performed to allow the flap to be coronally repositioned. Primary wound closure was obtained. In the left side, the masticatory (keratinized) mucosa was left in situ, and no sutures were applied (Control). After 3months of healing, absence of keratinized mucosa was confirmed at the test sites. Two recipient sites were prepared at each side of the mandible in the region of the third and fourth premolars. All implants were installed with the shoulder placed flush with the buccal alveolar bony crest, and abutments were connected to allow a non-submerged healing. Two free gingival mucosal grafts were harvested from the buccal region of the maxillary canines. One graft was left intact (gingival mucosal graft), while for the second, the epithelial layer was removed (gingival connective tissue graft). Subsequently, the grafts were fixed around the test implants in position of the third and fourth premolars, respectively. After 3months, the animals were euthanized and ground sections obtained.ResultsSimilar bony crest resorption and coronal extension of osseointegration were found at test and control sites. Moreover, similar dimensions of the peri-implant soft tissues were obtained at test and control sites.ConclusionsThe increase in the alveolar mucosal thickness by means of a gingival graft affected the peri-implant marginal bone resorption and soft tissue recession around implants. This resulted in outcomes that were similar to those at implants surrounded by masticatory mucosa, indicating that gingival grafting in the absence of keratinized mucosa around implants may reduce the resorption of the marginal crest and soft tissue recession.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The purpose of this study was to evaluate skeletal and dental stability in patients who had temporomandibular joint (TMJ) reconstruction and mandibular counterclockwise advancement using TMJ Concepts total join, prostheses (TMJ Concepts Inc. Ventura, CA) with maxillary osteotomies being performed at the same operation. All patients were operated at Baylor University Medical Center, Dallas TX, USA, by one surgeon (Wolford). Forty-seven females were studied; the average post-surgical follow-up was 40.6 months. Lateral cephalograms were analyzed to estimate surgical and post-surgical changes. During surgery, the occlusal plane angle decreased 14.9 +/- 8.0 degrees. The maxilla moved forward and upward. The posterior nasal spine moved downward and forward. The mandible advanced 7.9 +/- 3.5 mm at the lower incisor tips, 12.4 +/- 5.4 mm at Point B, 17.3 +/- 7.0 mm at menton, 18.4 +/- 8.5 mm at pogonion, and 11.0 +/- 5.3 mm at gonion. Vertically, the lower incisors moved upward -2.9 +/- 4.0 mm. At the longest follow-up post surgery, the maxilla showed minor horizontal changes while all mandibular measurements remained stable. TMJ reconstruction and mandibular advancement with TMJ Concepts total joint prosthesis in conjunction with maxillary osteotomies for counter-clockwise rotation of the rnaxillo-mandibular complex was a stable procedure for these patients at the longest follow-up.
Resumo:
Maintaining the volume of the alveolar process after extraction can be achieved by immediate implant placement and guided bone regeneration, with or without the use of biomaterials. The authors present a case report with a 10 years follow-up, rehabilitation using osseointegrated implants in the extraction area and maintenance of the volume of the alveolar process with autogenous cortical bone shavings.
Resumo:
Background. Although the long-term success of implant treatment has been well- established, failures can still occur and the smoking habit has been reported as a risk factor for implant loss. A literature review on the effects of smoking on the survival of dental implants was undertaken. Methods and Results. Medline database was used to carry out the review with the keywords “osseointegration”, “smoking” and “bone healing”. The cigarette has more than 4,000 bioactive chemical components with potential toxic effects to human tissues including bone. Nicotine is the main component of the cigarette and it is frequently associated with bone healing failures. Since smoking negatively affects the osseointegration of dental implants, the main target is to quit the consumption of cigarettes. Conclusion. Nevertheless, the smoking habit should not be an absolute contraindication for implant treatment, but, patients should be advised that they are at a greater risk of implant failure.
Resumo:
Purpose: The aim of this study was to evaluate the accuracy of cone-beam computed tomography (CBCT) for measuring the buccal bone volume around dental implants. Materials and methods: Three to six implants were inserted into the anterior maxilla of eight skulls, depending on the availability of bone, and after this, the CBCT was performed. By means of CBCT image, measurements of the bone wall at three points of the implant were obtained, analyzed and compared with those obtained in the plaster skull casting. Results: The results showed that for the three points of the implants, no statistically significant difference in the measurements was obtained from the plaster model and CBCT images. Conclusions: CBCT can be a useful tool for assessing buccal bone volume along the implant. To cite this article:?Shiratori LN, Marotti J, Yamanouchi J, Chilvarquer I, Contin I, Tortamano-Neto P. Measurement of buccal bone volume of dental implants by means of cone-beam computed tomography.?Clin. Oral Impl. Res. 23, 2012; 797804.?doi: 10.1111/j.1600-0501.2011.02207.x
Resumo:
Background: Accelerating bone healing around dental implants can reduce the long-term period between the insertion of implants and functional rehabilitation. Objective: This in vivo study evaluated the effect of a constant electromagnetic field (CEF) on bone healing around dental implants in dogs. Materials and methods: Eight dental implants were placed immediately after extraction of the first premolar and molar teeth on the mandible of two male dogs and divided into experimental (CEF) and control groups. A CEF at magnetic intensity of 0.8 mT with a pulse width of 25 mu s and frequency of 1.5 MHz was applied on the implants for 20 min per day for 2 weeks. Result and conclusion: After qualitative histological analysis, a small quantity of newly formed bone was observed in the gap between the implant surface and alveolar bone in both groups.