997 resultados para nutrient cycle
Resumo:
A weekly programme of water quality monitoring has been conducted by Slapton Ley Field Centre since 1970. Samples have been collected for the four main streams draining into Slapton Ley, from the Ley itself and from other sites within the catchment. On occasions, more frequent sampling has been undertaken during short-term research projects, usually in relation to nutrient export from the catchment. These water quality data, unparalleled in length for a series of small drainage basins in the British Isles, provide a unique resource for analysis of spatial and temporal variations in stream water quality within an agricultural area. Not surprisingly, given the eutrophic status of the Ley, most attention has focused on the nutrients nitrate and phosphate. A number of approaches to modelling nutrient loss have been attempted, including time series analysis and the application of nutrient export and physically-based models.
Resumo:
Asset allocation is concerned with the development of multi--‐asset portfolio strategies that are likely to meet an investor’s objectives based on the interaction of expected returns, risk, correlation and implementation from a range of distinct asset classes or beta sources. Challenges associated with the discipline are often particularly significant in private markets. Specifically, composition differences between the ‘index’ or ‘benchmark’ universe and the investible universe mean that there can often be substantial and meaningful deviations between the investment characteristics implied in asset allocation decisions and those delivered by investment teams. For example, while allocation decisions are often based on relatively low--‐risk diversified real estate ‘equity’ exposure, implementation decisions frequently include exposure to higher risk forms of the asset class as well as investments in debt based instruments. These differences can have a meaningful impact on the contribution of the asset class to the overall portfolio and, therefore, lead to a potential misalignment between asset allocation decisions and implementation. Despite this, the key conclusion from this paper is not that real estate investors should become slaves to a narrowly defined mandate based on IPD / NCREIF or other forms of benchmark replication. The discussion suggests that such an approach would likely lead to the underutilization of real estate in multi--‐asset portfolio strategies. Instead, it is that to achieve asset allocation alignment, real estate exposure should be divided into multiple pools representing distinct forms of the asset class. In addition, the paper suggests that associated investment guidelines and processes should be collaborative and reflect the portfolio wide asset allocation objectives of each pool. Further, where appropriate they should specifically target potential for ‘additional’ beta or, more marginally, ‘alpha’.
Resumo:
In this paper, numerical analyses of the thermal performance of an indirect evaporative air cooler incorporating a M-cycle cross-flow heat exchanger has been carried out. The numerical model was established from solving the coupled governing equations for heat and mass transfer between the product and working air, using the finite-element method. The model was developed using the EES (Engineering Equation Solver) environment and validated by published experimental data. Correlation between the cooling (wet-bulb) effectiveness, system COP and a number of air flow/exchanger parameters was developed. It is found that lower channel air velocity, lower inlet air relative humidity, and higher working-to-product air ratio yielded higher cooling effectiveness. The recommended average air velocities in dry and wet channels should not be greater than 1.77 m/s and 0.7 m/s, respectively. The optimum flow ratio of working-to-product air for this cooler is 50%. The channel geometric sizes, i.e. channel length and height, also impose significant impact to system performance. Longer channel length and smaller channel height contribute to increase of the system cooling effectiveness but lead to reduced system COP. The recommend channel height is 4 mm and the dimensionless channel length, i.e., ratio of the channel length to height, should be in the range 100 to 300. Numerical study results indicated that this new type of M-cycle heat and mass exchanger can achieve 16.7% higher cooling effectiveness compared with the conventional cross-flow heat and mass exchanger for the indirect evaporative cooler. The model of this kind is new and not yet reported in literatures. The results of the study help with design and performance analyses of such a new type of indirect evaporative air cooler, and in further, help increasing market rating of the technology within building air conditioning sector, which is currently dominated by the conventional compression refrigeration technology.
Resumo:
This paper provides a comparative study of the performance of cross-flow and counter-flow M-cycle heat exchangers for dew point cooling. It is recognised that evaporative cooling systems offer a low energy alternative to conventional air conditioning units. Recently emerged dew point cooling, as the renovated evaporative cooling configuration, is claimed to have much higher cooling output over the conventional evaporative modes owing to use of the M-cycle heat exchangers. Cross-flow and counter-flow heat exchangers, as the available structures for M-cycle dew point cooling processing, were theoretically and experimentally investigated to identify the difference in cooling effectiveness of both under the parallel structural/operational conditions, optimise the geometrical sizes of the exchangers and suggest their favourite operational conditions. Through development of a dedicated computer model and case-by-case experimental testing and validation, a parametric study of the cooling performance of the counter-flow and cross-flow heat exchangers was carried out. The results showed the counter-flow exchanger offered greater (around 20% higher) cooling capacity, as well as greater (15%–23% higher) dew-point and wet-bulb effectiveness when equal in physical size and under the same operating conditions. The cross-flow system, however, had a greater (10% higher) Energy Efficiency (COP). As the increased cooling effectiveness will lead to reduced air volume flow rate, smaller system size and lower cost, whilst the size and cost are the inherent barriers for use of dew point cooling as the alternation of the conventional cooling systems, the counter-flow system is considered to offer practical advantages over the cross-flow system that would aid the uptake of this low energy cooling alternative. In line with increased global demand for energy in cooling of building, largely by economic booming of emerging developing nations and recognised global warming, the research results will be of significant importance in terms of promoting deployment of the low energy dew point cooling system, helping reduction of energy use in cooling of buildings and cut of the associated carbon emission.
Resumo:
The authors estimate climate warming–related twenty-first-century changes of moisture transports from the descending into the ascending regions in the tropics. Unlike previous studies that employ time and space averaging, here homogeneous high horizontal and vertical resolution data from an Intergovernmental Panel on Climate Change Fourth Assessment Report (IPCC AR4) climate model are used. This allows for estimating changes in much greater detail (e.g., the estimation of the distribution of ascending and descending regions, changes in the vertical profile, and separating changes of the inward and outward transports). Low-level inward and midlevel outward moisture transports of the convective regions in the tropics are found to increase in a simulated anthropogenically warmed climate as compared to a simulated twentieth-century atmosphere, indicating an intensification of the hydrological cycle. Since an increase of absolute inward transport exceeds the absolute increase of outward transport, the resulting budget is positive, meaning that more water is projected to converge in the moist tropics. The intensification is found mainly to be due to the higher amount of water in the atmosphere, while the contribution of weakening wind counteracts this response marginally. In addition the changing statistical properties of the vertical profile of the moisture transport are investigated and the importance of the substantial outflow of moisture from the moist tropics at midlevels is demonstrated.