993 resultados para electric variables measurement
Resumo:
GOJANOVIC, B., J. WELKER, K. IGLESIAS, C. DAUCOURT, and G. GREMION. Electric Bicycles as a New Active Transportation Modality to Promote Health. Med. Sci. Sports Exerc., Vol. 43, No. 11, pp. 2204-2210, 2011. Electrically assisted bicycles (EAB) are an emerging transportation modality favored for environmental reasons. Some physical effort is required to activate the supporting engine, making it a potential active commuting option. Purpose: We hypothesized that using an EAB in a hilly city allows sedentary subjects to commute comfortably, while providing a sufficient effort for health-enhancing purposes. Methods: Sedentary subjects performed four different trips at a self-selected pace: walking 1.7 km uphill from the train station to the hospital (WALK), biking 5.1 km from the lower part of town to the hospital with a regular bike (BIKE), or EAB at two different power assistance settings (EAB(high), EAB(std)). HR, oxygen consumption, and need to shower were recorded. Results: Eighteen sedentary subjects (12 female, 6 male) age 36 +/- 10 yr were included, with (V) over dotO(2max) of 39.4 +/- 5.4 mL.min(-1).kg(-1). Time to complete the course was 22 (WALK), 19 (EAB(high)), 21 (EAB(std)), and 30 (BIKE) min. Mean %(V) over dotO(2max) was 59.0%, 54.9%, 65.7%, and 72.8%. Mean%HR(max) was 71.5%, 74.5%, 80.3%, and 84.0%. There was no significant difference between WALK and EAB(high), but all other comparisons were different (P < 0.05). Two subjects needed to shower after EAB(high), 3 needed to shower after WALK, 8 needed to shower after EAB(std), and all 18 needed to shower after BIKE. WALK and EAB(high) elicited 6.5 and 6.1 METs (no difference), whereas it was 7.3 and 8.2 for EAB(std) and BIKE. Conclusions: EAB is a comfortable and ecological transportation modality, helping sedentary people commute to work and meet physical activity guidelines. Subjects appreciated ease of use and mild effort needed to activate the engine support climbing hills, without the need to shower at work. EAB can be promoted in a challenging urban environment to promote physical activity and mitigate pollution issues.
Resumo:
This work had two primary objectives: 1) to produce a working prototype for automated printability assessment and 2) to perform a study of available machine vision and other necessary hardware solutions. The three printability testing methods, IGT Picking,He¬liotest, and mottling, considered in this work have several different requirements and the task was to produce a single automated testing system suitable for all methods. A system was designed and built and its performance was tested using the Heliotest. Working proto¬types are important tools for implementing theoretical methods into practical systems and testing and demonstrating the methodsin real life conditions. The system was found to be sufficient for the Heliotest method. Further testing and possible modifications related to other two test methods were left for future works. A short study of available systems and solutions concerning image acquisition of machine vision was performed. The theoretical part of this study includes lighting systems, optical systems and image acquisition tools, mainly cameras and the underlying physical aspects for each portion.
Resumo:
To compare the prediction of hip fracture risk of several bone ultrasounds (QUS), 7062 Swiss women > or =70 years of age were measured with three QUSs (two of the heel, one of the phalanges). Heel QUSs were both predictive of hip fracture risk, whereas the phalanges QUS was not. INTRODUCTION: As the number of hip fracture is expected to increase during these next decades, it is important to develop strategies to detect subjects at risk. Quantitative bone ultrasound (QUS), an ionizing radiation-free method, which is transportable, could be interesting for this purpose. MATERIALS AND METHODS: The Swiss Evaluation of the Methods of Measurement of Osteoporotic Fracture Risk (SEMOF) study is a multicenter cohort study, which compared three QUSs for the assessment of hip fracture risk in a sample of 7609 elderly ambulatory women > or =70 years of age. Two QUSs measured the heel (Achilles+; GE-Lunar and Sahara; Hologic), and one measured the heel (DBM Sonic 1200; IGEA). The Cox proportional hazards regression was used to estimate the hazard of the first hip fracture, adjusted for age, BMI, and center, and the area under the ROC curves were calculated to compare the devices and their parameters. RESULTS: From the 7609 women who were included in the study, 7062 women 75.2 +/- 3.1 (SD) years of age were prospectively followed for 2.9 +/- 0.8 years. Eighty women reported a hip fracture. A decrease by 1 SD of the QUS variables corresponded to an increase of the hip fracture risk from 2.3 (95% CI, 1.7, 3.1) to 2.6 (95% CI, 1.9, 3.4) for the three variables of Achilles+ and from 2.2 (95% CI, 1.7, 3.0) to 2.4 (95% CI, 1.8, 3.2) for the three variables of Sahara. Risk gradients did not differ significantly among the variables of the two heel QUS devices. On the other hand, the phalanges QUS (DBM Sonic 1200) was not predictive of hip fracture risk, with an adjusted hazard risk of 1.2 (95% CI, 0.9, 1.5), even after reanalysis of the digitalized data and using different cut-off levels (1700 or 1570 m/s). CONCLUSIONS: In this elderly women population, heel QUS devices were both predictive of hip fracture risk, whereas the phalanges QUS device was not.