994 resultados para controlled atmosphere storage


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Direct torque control (DTC) is a new control method for rotating field electrical machines. DTC controls directly the motor stator flux linkage with the stator voltage, and no stator current controllers are used. With the DTC method very good torque dynamics can be achieved. Until now, DTC has been applied to asynchronous motor drives. The purpose of this work is to analyse the applicability of DTC to electrically excited synchronous motor drives. Compared with asynchronous motor drives, electrically excited synchronous motor drives require an additional control for the rotor field current. The field current control is called excitation control in this study. The dependence of the static and dynamic performance of DTC synchronous motor drives on the excitation control has been analysed and a straightforward excitation control method has been developed and tested. In the field weakening range the stator flux linkage modulus must be reduced in order to keep the electro motive force of the synchronous motor smaller than the stator voltage and in order to maintain a sufficient voltage reserve. The dynamic performance of the DTC synchronous motor drive depends on the stator flux linkage modulus. Another important factor for the dynamic performance in the field weakening range is the excitation control. The field weakening analysis considers both dependencies. A modified excitation control method, which maximises the dynamic performance in the field weakening range, has been developed. In synchronous motor drives the load angle must be kept in a stabile working area in order to avoid loss of synchronism. The traditional vector control methods allow to adjust the load angle of the synchronous motor directly by the stator current control. In the DTC synchronous motor drive the load angle is not a directly controllable variable, but it is formed freely according to the motor’s electromagnetic state and load. The load angle can be limited indirectly by limiting the torque reference. This method is however parameter sensitive and requires a safety margin between the theoretical torque maximum and the actual torque limit. The DTC modulation principle allows however a direct load angle adjustment without any current control. In this work a direct load angle control method has been developed. The method keeps the drive stabile and allows the maximal utilisation of the drive without a safety margin in the torque limitation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In experiments conducted in laboratory, the effect of fungicides, seed dresser adjuvants and storage time in the control of Drechslera teres in seeds of barley cultivar BRS Elis, with 58% incidence, was quantified. Fungicides indicated by barley research (carboxin + thiram, difenoconazole and triadimenol) compared with the mixture carbendazim + iprodione were tested. As seed dresser adjuvants, water (500m mL/100 Kg) and a polymer (150 mL/100 Kg) were used. Treated seeds were stored in paper bags and kept in the refrigerator at 5ºC. At 30-day intervals during six months, seeds were plated on semi-selective Reis's medium (1983). The best control was obtained by the mixtures carboxin + thiram and carbendazim + iprodione and the polymer as seed dresser. The control efficiency was improved by the storage time without negatively affecting seed germination. Due to the transmission efficiency, the fungus eradication in seeds should be pursued.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The rice grain is frequently infected by a series of pathogens (fungi) during its storage, producing damages to the economy and health of humans. The aim of this study was to identify the fungal genera present in different rice genotypes and to quantify their variation during storage. Paddy, brown and milled rice fractions of Nutriar, (N) H329-5(H329) and Don Ignacio genotypes were analyzed at 4, 8 and 12 months of storage. Fungi were identified based on their micromorphological characteristics and colonies. The observed genera according to their frequency were: Alternaria, Nigrospora, Epicoccum, Bipolaris, Curvularia, Cladosporium and Fusarium (field fungi) and Penicillium and Aspergillus (storage fungi). The mycobiota composition was different depending on the grain fraction and the period of storage: field fungi were located in the hulls and bran layers, while storage fungi were mainly in the endosperm. The different genotypes showed different susceptibility to contamination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this experiment was to evaluate the effect of storage temperature on the viability and vigour of A. peregrina seeds. Seeds of A. peregrina harvested in Viçosa-MG, in September 2005 were used. The seeds were stored in the Laboratory of Forest Seeds Analysis (LASF) of the Universidade Federal de Viçosa (UFV), in a cold chamber, under approximately 5ºC over150 days. The seeds were stored under 20ºC for 150 days more. Seed moisture was determined after oven-drying at 105 ± 3ºC for 24 hours. The seeds were analyzed monthly using germination, tetrazolium and electrical conductivity tests and Osmopriming during 300 days, with four repetitions of 25 seeds. A. peregrina seeds kept a constant percentage of germination and viable seeds under the tetrazolium test for five months of storage, under either 5ºC and 20ºC. The electrical conductivity test showed significant differences in relation to the storage period, proving to be more sensitive than the standard germination test. Seed priming in PEG -0,4 MPa solution was not efficient in recovering the viability and vigor of the stored seeds at 5ºC and 20ºC.