1000 resultados para Wavefront testing
Resumo:
The purpose of this study was to apply and compare two time-domain analysis procedures in the determination of oxygen uptake (VO2) kinetics in response to a pseudorandom binary sequence (PRBS) exercise test. PRBS exercise tests have typically been analysed in the frequency domain. However, the complex interpretation of frequency responses may have limited the application of this procedure in both sporting and clinical contexts, where a single time measurement would facilitate subject comparison. The relative potential of both a mean response time (MRT) and a peak cross-correlation time (PCCT) was investigated. This study was divided into two parts: a test-retest reliability study (part A), in which 10 healthy male subjects completed two identical PRBS exercise tests, and a comparison of the VO2 kinetics of 12 elite endurance runners (ER) and 12 elite sprinters (SR; part B). In part A, 95% limits of agreement were calculated for comparison between MRT and PCCT. The results of part A showed no significant difference between test and retest as assessed by MRT [mean (SD) 42.2 (4.2) s and 43.8 (6.9) s] or by PCCT [21.8 (3.7) s and 22.7 (4.5) s]. Measurement error (%) was lower for MRT in comparison with PCCT (16% and 25%, respectively). In part B of the study, the VO2 kinetics of ER were significantly faster than those of SR, as assessed by MRT [33.4 (3.4) s and 39.9 (7.1) s, respectively; P<0.01] and PCCT [20.9 (3.8) s and 24.8 (4.5) s; P < 0.05]. It is possible that either analysis procedure could provide a single test measurement Of VO2 kinetics; however, the greater reliability of the MRT data suggests that this method has more potential for development in the assessment Of VO2 kinetics by PRBS exercise testing.
Resumo:
Lactoperoxidase (LP) exerts antimicrobial effects in combination with H2O2 and either thiocyanate (SCN-) or a halide (e. g., I-). Garlic extract in the presence of ethanol has also been used to activate the LP system. This study aimed to determine the effects of 3 LP activation systems (LP+SCN-+H2O2; LP+I-+H2O2; LP + garlic extract + ethanol) on the growth and activity of 3 test organisms (Staphylococcus aureus, Pseudomonas aeruginosa, and Bacillus cereus). Sterilized milk was used as the reaction medium, and the growth pattern of the organisms and a range of keeping quality (KQ) indicators (pH, titratable acidity, ethanol stability, clot on boiling) were monitored during storage at the respective optimum growth temperature for each organism. The LP+I-+H2O2 system reduced bacterial counts below the detection limit shortly after treatment for all 3 organisms, and no bacteria could be detected for the duration of the experiment (35 to 55 h). The KQ data confirmed that the milk remained unspoiled at the end of the experiments. The LP + garlic extract + ethanol system, on the other hand, had no effect on the growth or KQ with P. aeruginosa, but showed a small retardation of growth of the other 2 organisms, accompanied by small increases (5 to 10 h) in KQ. The effects of the LP+SCN-+H2O2 system were intermediate between those of the other 2 systems and differed between organisms. With P. aeruginosa, the system exerted total inhibition within 10 h of incubation, but the bacteria regained viability after a further 5 h, following a logarithmic growth curve. This was reflected in the KQ indicators, which implied an extension of 15 h. With the other 2 bacterial species, LP+SCN-+H2O2 exerted an obvious inhibitory effect, giving a lag phase in the growth curve of 5 to 10 h and KQ extension of 10 to 15 h. When used in combination, I- and SCN- displayed negative synergy.
Resumo:
The mathematical models that describe the immersion-frying period and the post-frying cooling period of an infinite slab or an infinite cylinder were solved and tested. Results were successfully compared with those found in the literature or obtained experimentally, and were discussed in terms of the hypotheses and simplifications made. The models were used as the basis of a sensitivity analysis. Simulations showed that a decrease in slab thickness and core heat capacity resulted in faster crust development. On the other hand, an increase in oil temperature and boiling heat transfer coefficient between the oil and the surface of the food accelerated crust formation. The model for oil absorption during cooling was analysed using the tested post-frying cooling equation to determine the moment in which a positive pressure driving force, allowing oil suction within the pore, originated. It was found that as crust layer thickness, pore radius and ambient temperature decreased so did the time needed to start the absorption. On the other hand, as the effective convective heat transfer coefficient between the air and the surface of the slab increased the required cooling time decreased. In addition, it was found that the time needed to allow oil absorption during cooling was extremely sensitive to pore radius, indicating the importance of an accurate pore size determination in future studies.
Resumo:
Older adults often demonstrate higher levels of false recognition than do younger adults. However, in experiments using novel shapes without preexisting semantic representations, this age-related elevation in false recognition was found to be greatly attenuated. Two experiments tested a semantic categorization account of these findings, examining whether older adults show especially heightened false recognition if the stimuli have preexisting semantic representations, such that semantic category information attenuates or truncates the encoding or retrieval of item-specific perceptual information. In Experiment 1, ambiguous shapes were presented with or without disambiguating semantic labels. Older adults showed higher false recognition when labels were present but not when labels were never presented. In Experiment 2, older adults showed higher false recognition for concrete but not abstract objects. The semantic categorization account was supported.
Resumo:
This paper deals with the key issues encountered in testing during the development of high-speed networking hardware systems by documenting a practical method for "real-life like" testing. The proposed method is empowered by modern and commonly available Field Programmable Gate Array (FPGA) technology. Innovative application of standard FPGA blocks in combination with reconfigurability are used as a back-bone of the method. A detailed elaboration of the method is given so as to serve as a general reference. The method is fully characterised and compared to alternatives through a case study proving it to be the most efficient and effective one at a reasonable cost.