Object  In a companion study, the authors describe the development of a new instrument named the Wireless Instantaneous Neurotransmitter Concentration System (WINCS), which couples digital telemetry with fast-scan cyclic voltammetry (FSCV) to measure extracellular concentrations of dopamine. In the present study, the authors describe the extended capability of the WINCS to use fixed potential amperometry (FPA) to measure extracellular concentrations of dopamine, as well as glutamate and adenosine. Compared with other electrochemical techniques such as FSCV or high-speed chronoamperometry, FPA offers superior temporal resolution and, in combination with enzyme-linked biosensors, the potential to monitor nonelectroactive analytes in real time.

Methods  The WINCS design incorporated a transimpedance amplifier with associated analog circuitry for FPA; a microprocessor; a Bluetooth transceiver; and a single, battery-powered, multilayer, printed circuit board. The WINCS was tested with 3 distinct recording electrodes: 1) a carbon-fiber microelectrode (CFM) to measure dopamine; 2) a glutamate oxidase enzyme–linked electrode to measure glutamate; and 3) a multiple enzyme–linked electrode (adenosine deaminase, nucleoside phosphorylase, and xanthine oxidase) to measure adenosine. Proof-of-principle analyses included noise assessments and in vitro and in vivo measurements that were compared with similar analyses by using a commercial hardwired electrochemical system (EA161 Picostat, eDAQ; Pty Ltd). In urethane-anesthetized rats, dopamine release was monitored in the striatum following deep brain stimulation (DBS) of ascending dopaminergic fibers in the medial forebrain bundle (MFB). In separate rat experiments, DBS-evoked adenosine release was monitored in the ventrolateral thalamus. To test the WINCS in an operating room setting resembling human neurosurgery, cortical glutamate release in response to motor cortex stimulation (MCS) was monitored using a large-mammal animal model, the pig.

Results   The WINCS, which is designed in compliance with FDA-recognized consensus standards for medical electrical device safety, successfully measured dopamine, glutamate, and adenosine, both in vitro and in vivo. The WINCS detected striatal dopamine release at the implanted CFM during DBS of the MFB. The DBS-evoked adenosine release in the rat thalamus and MCS-evoked glutamate release in the pig cortex were also successfully measured. Overall, in vitro and in vivo testing demonstrated signals comparable to a commercial hardwired electrochemical system for FPA.

Conclusions  By incorporating FPA, the chemical repertoire of WINCS-measurable neurotransmitters is expanded to include glutamate and other nonelectroactive species for which the evolving field of enzyme-linked biosensors exists. Because many neurotransmitters are not electrochemically active, FPA in combination with enzyme-linked microelectrodes represents a powerful intraoperative tool for rapid and selective neurochemical sampling in important anatomical targets during functional neurosurgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Voltammetric behavior at gold electrodes in aqueous media is known to be strongly dependent on electrode polishing and history. In this study, an electrode array consisting of 100 nominally identical and individually addressable gold disks electrodes, each with a radius of 127 µm, has been fabricated. The ability to analyze both individual electrode and total array performance enables microscopic aspects of the overall voltammetric response arising from variable levels of inhomogeneity in each electrode to be identified. The array configuration was initially employed with the reversible and hence relatively surface insensitive [Ru(NH3)6]3+/2+ reaction and then with the more highly surface sensitive quasi-reversible [Fe(CN)6]3−/4− process. In both these cases, the reactants and products are solution soluble and, at a scan rate of 50 mV s−1, each electrode in the array is assumed to behave independently, since no evidence of overlapping of the diffusion layers was detected. As would be expected, the variability of the individual electrodesʼ responses was significantly larger than found for the summed electrode behavior. In the case of cytochrome c voltammetry at a 4,4′-dipyridyl disulfide modified electrode, a far greater dependence on electrode history and electrode heterogeneity was detected. In this case, voltammograms derived from individual electrodes in the gold array electrode exhibit shape variations ranging from peak to sigmoidal. However, again the total response was always found to be well-defined. This voltammetry is consistent with a microscopic model of heterogeneity where some parts of each chemically modified electrode surface are electroactive while other parts are less active. The findings are consistent with the common existence of electrode heterogeneity in cyclic voltammetric responses at gold electrodes, that are normally difficult to detect, but fundamentally important, as electrode nonuniformity can give rise to subtle forms of kinetic and other forms of dispersion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study examined the influence of triethyl and tributyl phosphite (TEP and TBP) additives on the electrochemical performance of lithium-ion cells. The cell performance of the TEP- and TBP-containing electrolytes was evaluated by cyclic voltammetry, thermogravimetric analysis, electrochemical impedance spectroscopy, Fourier transform infrared spectroscopy and scanning electron microscopy. The flammability of the electrolytes was also investigated by measuring the self-extinguishing time of the electrolytes. The results showed that the TEP and TBP additives suppressed the flammability of the electrolyte, with a significant improvement in cell performance observed for the TEP additive. In addition, TEP and TBP additives improved the thermal stability of the battery and its electrochemical cell performance. Overall, 5 wt% TEP and TBP can be used as a flame-retarding additive to improve the cell performance of Li-ion batteries due to the decrease in cell impedance and SEI formation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A series of new metal (M) dithiolene complexes bearing terthiophene (3, 12, M = Ni; 4, M = Pd; 5, 6, M = Au) and 2,5-bis(para-methoxyphenyl)thiophene units (14, M = Ni; 15, 16, M = Au; 17, M = Pd) have been synthesised in 38–99% yield. The electrochemical properties of the materials have been characterised by cyclic voltammetry and UV-vis spectroelectrochemistry. The nickel complexes possess low oxidation potentials (−0.12 to −0.25 V vs Ag/AgCl) due to the electron-rich dithiolene centres and all complexes display ligand-based redox activity. The terthiophene derivatives have been polymerised by electrochemical oxidation to give stable films with, in the case of poly(3), broad absorption characteristics. Charge transfer materials have been isolated from 14 and 16 with conductivities in the range 9 × 10−6 to 7 × 10−8 S cm−1.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A highly sensitive and selective dopamine sensor was fabricated with the unique 3D carbon nanotube nanoweb (CNT-N) electrode. The as-synthesised CNT-N was modified by oxygen plasma to graft functional groups in order to increase selective electroactive sites at the CNT sidewalls. This electrode was characterized physically and electrochemically using HRSEM, Raman, FT-IR, and cyclic voltammetry (CV). Our investigations indicated that the O2-plasma treated CNT-N electrode could serve as a highly sensitive biosensor for the selective sensing of dopamine (DA, 1 μM to 20 μM) in the presence of ascorbic acid (AA, 1000 μM).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The potential of a quasi-reference electrode can be determined by introducing an internal reference redox system (IRRS) which comprises either the oxidizable or reducible form of a reversible (and, ideally, outer-sphere) redox couple and then observing the cyclic voltammetric responses. The objective is to choose the IRRS so that the cyclic voltammetric response for the simultaneously present electroactive analyte system (ANS) can be observed independently of the IRRS response. We identify three fundamental paradigms describing the relative positioning of the IRRS and ANS on the potential scale, the operative redox components for the IRRS and ANS, and the starting potential (E start), reversing potential (E rev), and ending potential (E end) for the cyclic voltammetric scan as follows: paradigm A, an optimal paradigm which can produce completely independent cyclic voltammetric responses for the IRRS or for ANS; paradigm B, a less-than-optimal paradigm which can produce an independent cyclic voltammetry (CV) response for the ANS or a mixed response for the IRRS with that response on top of the ANS response; paradigm C, a problematic paradigm that can produce an independent CV response for the IRRS or a mixed response for the ANS with that response on top of the IRRS response; and any mixed response produces a thermodynamically favored redox cross-reaction which couples the IRRS and ANS systems and which can complicate the analysis of the ANS and IRRS responses. The conclusion is that paradigm C is to be avoided.