997 resultados para Thickness dependence
Resumo:
The dielectric properties of pharmaceutical powder-(paracetamol, aspirin, lactose, maize starch, adipic acid) solvent (water) mixtures were measured at 2,450 MHz at a range of moisture contents (0-1.0 kg kg(-1), dry basis) and temperatures (20-70 A degrees C). The dielectric constant (epsilon'), loss factor (epsilon aEuro(3)) and penetration depth (d (p)) were found to be dependent on frequency, moisture content, temperature and powder type. For powder-water mixtures, a linear increase in the dielectric properties with moisture content was observed, whilst the temperature dependence was of quadratic form. The penetration depth was also significantly affected by temperature and moisture content. Although, epsilon aEuro(3) also increased with increasing temperature, variation with moisture content was temperature dependent. This information on dielectric properties is essential for mathematical description of the pharmaceutical product temperature history during microwave heating and for the design of microwave drying equipment.
Resumo:
Background: A full-thickness macular hole (FTMH) is a common retinal condition associated with impaired vision. Randomised controlled trials (RCTs) have demonstrated that surgery, by means of pars plana vitrectomy and post-operative intraocular tamponade with gas, is effective for stage 2, 3 and 4 FTMH. Internal limiting membrane (ILM) peeling has been introduced as an additional surgical manoeuvre to increase the success of the surgery; i.e. increase rates of hole closure and visual improvement. However, little robust evidence exists supporting the superiority of ILM peeling compared with no-peeling techniques. The purpose of FILMS (Full-thickness macular hole and Internal Limiting Membrane peeling Study) is to determine whether ILM peeling improves the visual function, the anatomical closure of FTMH, and the quality of life of patients affected by this disorder, and the cost-effectiveness of the surgery. Methods/Design: Patients with stage 2-3 idiopathic FTMH of less or equal than 18 months duration (based on symptoms reported by the participant) and with a visual acuity = 20/40 in the study eye will be enrolled in this FILMS from eight sites across the UK and Ireland. Participants will be randomised to receive combined cataract surgery (phacoemulsification and intraocular lens implantation) and pars plana vitrectomy with postoperative intraocular tamponade with gas, with or without ILM peeling. The primary outcome is distance visual acuity at 6 months. Secondary outcomes include distance visual acuity at 3 and 24 months, near visual acuity at 3, 6, and 24 months, contrast sensitivity at 6 months, reading speed at 6 months, anatomical closure of the macular hole at each time point (1, 3, 6, and 24 months), health related quality of life (HRQOL) at six months, costs to the health service and the participant, incremental costs per quality adjusted life year (QALY) and adverse events. Discussion: FILMS will provide high quality evidence onthe role of ILM peeling in FTMH surgery. © 2008 Lois et al; licensee BioMed Central Ltd.
Resumo:
PURPOSE. To determine whether internal limiting membrane (ILM) peeling is effective and cost effective compared with no peeling in patients with idiopathic stage 2 or 3 full-thickness maculay hole (FTMH). METHODS. This was a pragmatic multicenter randomized controlled trial. Eligible participants from nine centers were randomized to ILM peeling or no peeling (1:1 ratio) in addition to phacovitrectomy, including detachment and removal of the posterior hyaloid and gas tamponade. The primary outcome was distance visual acuity (VA) at 6 months after surgery. Secondary outcomes included hole closure, distance VA at other time points, near VA, contrast sensitivity, reading speed, reoperations, complications, resource use, and participant-reported health status, visual function, and costs. RESULTS. Of 141 participants randomized in nine centers, 127 (90%) completed the 6-month follow-up. Nonstatistically significant differences in distance visual acuity at 6 months were found between groups (mean difference, 4.8; 95% confidence interval [CI], -0.3 to 9.8; P = 0.063). There was a significantly higher rate of hole closure in the ILM-peel group (56 [84%] vs. 31 [48%]) at 1 month (odds ratio [OR], 6.23; 95% CI, 2.64-14.73; P <0.001) with fewer reoperations (8 [12%] vs. 31 [48%]) performed by 6 months (OR, 0.14; 95% CI, 0.05- 0.34; P <0.001). Peeling the ILM is likely to be cost effective. CONCLUSIONS. There was no evidence of a difference in distance VA after the ILM peeling and no-ILM peeling techniques. An important benefit in favor of no ILM peeling was ruled out. Given the higher anatomic closure and lower reoperation rates in the ILM-peel group, ILM peeling seems to be the treatment of choice for idiopathic stage 2 to 3 FTMH. © 2011 The Association for Research in Vision and Ophthalmology, Inc.
Resumo:
Aim: To determine whether internal limiting membrane (ILM) peeling is cost-effective compared with no peeling for patients with an idiopathic stage 2 or 3 full-thickness macular hole. Methods: A cost-effectiveness analysis was performed alongside a randomised controlled trial. 141 participants were randomly allocated to receive macular-hole surgery, with either ILM peeling or no peeling. Health-service resource use, costs and quality of life were calculated for each participant. The incremental cost per quality-adjusted life year (QALY) gained was calculated at 6 months. Results: At 6 months, the total costs were on average higher (£424, 95% CI -182 to 1045) in the No Peel arm, primarily owing to the higher reoperation rate in the No Peel arm. The mean additional QALYs from ILM peel at 6 months were 0.002 (95% CI 0.01 to 0.013), adjusting for baseline EQ-5D and other minimisation factors. A mean incremental cost per QALY was not computed, as Peeling was on average less costly and slightly more effective. A stochastic analysis suggested that there was more than a 90% probability that Peeling would be cost-effective at a willingness-to-pay threshold of £20 000 per QALY. Conclusion: Although there is no evidence of a statistically significant difference in either costs or QALYs between macular hole surgery with or without ILM peeling, the balance of probabilities is that ILM Peeling is likely to be a cost-effective option for the treatment of macular holes. Further long-term follow-up data are needed to confirm these findings.
Resumo:
We report on a temperature dependence of the frequency of all the major peaks in the Raman spectra of carbon nanotubes, using different excitation laser powers at the sample. The frequency decreases with increasing temperature for all peaks, and the shifts in Raman frequencies are linear in the temperature of the sample. In comparison, a similar dependence is found in active carbon, but no shift is observed for the highly ordered pyrolytic graphite within the same range of variation in laser power. A lowering of frequency at higher temperature implies an increase in the carbon-carbon distance at higher temperature. The relatively strong temperature dependence in carbon nanotubes and active carbon may be due to the enhanced increase in carbon-carbon distance. This enhancement may originate from the heavy defects and disorder in these materials. (C) 1998 American Institute of Physics. [S0021-8979(98)05219-0].