998 resultados para Taylor made


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compared pressure and thermal thresholds after administration of three opioids in eight cats. Pressure stimulation was performed via a bracelet taped around the forearm. Three ball-bearings were advanced against the forearm by inflation of a modified blood pressure bladder. Pressure in the cuff was recorded at the end point (leg shake and head turn). Thermal threshold was tested as previously reported using a heated probe held against the thorax [Dixon et al. (2002) Research in Veterinary Science, 72, 205]. After baseline recordings, each cat received subcutaneous methadone 0.2 mg/kg, morphine 0.2 mg/kg, buprenorphine 0.02 mg/kg or saline 0.3 mL in a four period cross-over study. Measurements were made at 15, 30, 45 min and 1, 2, 3, 4, 8, 12 and 24 h after the injection. Data were analysed by ANOVA (P < 0.05). There were no significant changes in thresholds after saline. Thermal threshold increased at 45 min after buprenorphine (maximum 2.8 +/- 3 degrees C), 1-3 h after methadone (maximum 3.4 +/- 1.9 degrees C) and 45 min to 1 h (maximum 3.4 +/- 2 degrees C) after morphine. Pressure threshold increased 30-45 min (maximum 238 +/- 206 mmHg) after buprenorphine, 45-60 min after methadone (maximum 255 +/- 232 mmHg) and 45-60 min and 3-6 h (maximum 255 +/- 232 mmHg) after morphine. Morphine provided the best analgesia, and methadone appears a promising alternative. Buprenorphines limited effect was probably related to the subcutaneous route of administration. Previously, buprenorphine has produced much greater effects when given by other routes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate a prototype pressure stimulus device for use in the cat and to compare with a known thermal threshold device.Eight healthy adult cats weighing between 3.0 and 4.9 kg.Pressure stimulation was given via a plastic bracelet taped around the forearm. Three 2.4 mm diameter ball bearings, in a 10-mm triangle, were advanced against the craniolateral surface of the antebrachium by manual inflation of a modified blood pressure bladder. Pressure in the cuff was recorded at the end point (leg shake and head turn). Thermal threshold was also tested. Stimuli were stopped if they reached 55 degrees C or 450 mmHg without response. After four pressure and thermal threshold baselines, each cat received SC buprenorphine 0.01 mg kg(-1), carprofen 4 mg kg(-1) or saline 0.3 mL in a three period cross-over study with a 1-week interval. The investigator was blinded to the treatment. Measurements were made at 0.25. 0.5, 0.75, 1, 2, 3, 4, 6, 8, and 24 hours after injection. Data were analyzed by using ANOVA.There were no significant changes in thermal or pressure threshold after administration of saline or carprofen, but thermal threshold increased from 60 minutes until 8 hours after administration of buprenorphine (p < 0.05). The maximum increase in threshold from baseline (Delta T-max) was 3.5 +/- 3.1 degrees C at 2 hours. Pressure threshold increased 2 hours after administration of buprenorphine (p < 0.05) when the increase in threshold above baseline (Delta P-max) was 162 +/- 189 mmHg.This pressure device resulted in thresholds that were affected by analgesic treatment in a similar manner but to a lesser degree than the thermal method. Pressure stimulation may be a useful additional method for analgesic studies in cats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Veterinary surgery for treatment of wild animals is becoming an increasingly demanding task because it involves animals of different anatomy, many of them are already stressed and treatment must be performed to the highest standard in the minimum period of time. Craniofacial alterations may occur for three main reasons: genetic, functional or a combination of both. It is possible to modify the functional cause using intraoral devices like inclined plane. The treatment planning can be made based on virtual 3D models and rapid prototyping. An approximately 9 months old, 3.7 kg male Brazilian fox (Lycalopex vetulus) was referred to the Veterinary Hospital. Physical examination showed malocclusion with a deviation of the mandible to the right side. The virtual 3D model of the head was generated based on CT image data. The 3D models and rapid prototyping opened up new possibilities for the surgical planning and treatment of wild animals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A mandioca, apesar de ser nativa do Brasil, ainda é sub-utilizada principalmente quando a questão é o aproveitamento da sua parte aérea. Com o objetivo de estudar o potencial da mandioca para alimentação animal, o presente trabalho avaliou as características da parte aérea da planta quando submetida os processos de ensilagem e fenação. Os tratamentos consistiram de: parte aérea ensilada sem emurchecimento (PAS); parte aérea ensilada após 24 horas de emurchecimento (PAE) e parte aérea fenada (PAF). As análises químicas foram realizadas a fim de avaliar os parâmetros que determinam o valor nutritivo da silagem e do feno. O emurchecimento elevou o teor de matéria seca de 25% no material in natura para 27.7%, sem alterar o teor de carboidratos solúveis (33.3 e 35.5% de MS na PAS e PAE respectivamente), bem como o poder tampão (204 mmol kg-1 MS na PAS e 195 mmol kg-1 MS na PAE). Nem o pH (3.57 na silagem in natura e 3.60 na PAE) nem os teores de NIDA (11.32% do nitrogênio total na MS na PAS e 9.99% do nitrogênio total na MS na PAE) diferiram entre as silagens, mas o NIDA foi maior na forragem fenada (15.39%). Contudo, o emurchecimento provocou aumento no nitrogênio amoniacal (de 6.5% do nitrogênio total na MS da PAS para 13.0 do nitrogênio total na MS da PAE). Os teores de ácidos graxos voláteis não sofreram alterações com o emurchecimento. O processo de ensilagem reduziu os teores de ácido cianídrico livre (HCN), sem, contudo, alterar a cianidrina.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. An increase in occlusal vertical dimension (OVD) may occur after processing complete dentures. Although many factors that generate this change are known, no information is available in the dental literature regarding the effect that the occlusal scheme may have on the change in OVD.Purpose. This in vitro study compared the increase in OVD, after processing, between complete dentures with teeth arranged in lingualized balanced occlusion and conventional balanced occlusion.Material and methods. Thirty sets of complete dentures were evaluated as follows: 15 sets of complete dentures were arranged in conventional balanced occlusion (control) and 15 sets of complete dentures were arranged in lingualized balanced occlusion. All dentures were compression molded with a long polymerization cycle. The occlusal vertical dimension was measured with a micrometer (mm) before and after processing each set of dentures. Data were analyzed using an independent t test (alpha=.05).Results. The mean increase in the OVD, after processing, was 0.87 +/- 0.21 mm for the control group and 0.90 +/- 0.27 mm for the experimental group. There was no significant difference between the groups.Conclusion. After processing, dentures set in lingualized balanced occlusion showed an increase in OVD similar to those set in conventional balanced occlusion.